2066 W. 11th Street Unit 1, Trinity Hall Farm Estate
Upland, CA 91786 Nuffield Road, Cambridge CB4 1TG UK
Phone: (800) 452-6788 Phone: +44(0)1223-420022
Fax: (909) 946-3597 Fax: +44(0)1223-420561
System Components ................................................................................................................................................... 4
Cameras and Lenses ................................................................................................................................................ 5
Connecting the Power Cables ................................................................................................................................... 9
Using the System ....................................................................................................................................................... 11
Powering Up the System ......................................................................................................................................... 11
Preparing the Transilluminator for Use .................................................................................................................... 11
Operating the TS2 Software Interface ..................................................................................................................... 12
Using the UV Gel Viewer Window ........................................................................................................................... 12
Setting User Preferences ........................................................................................................................................ 14
Changing Lighting and Filter Settings ...................................................................................................................... 16
Identifying the Touch Screen Buttons and Functions .............................................................................................. 17
Using Templates ..................................................................................................................................................... 25
Connecting to a Network ......................................................................................................................................... 26
Installing Drivers or Additional Software .................................................................................................................. 26
Service Procedures .................................................................................................................................................... 27
Replacement Parts and Accessories ....................................................................................................................... 27
Technical Support ................................................................................................................................................... 28
GelDoc-It
TS2
and ChemiDoc-It
Introduction
The GelDoc-It
fluorescent gel images.
In addition to gel documentation capabilities, the ChemiDoc-It
scientific-grade CCD camera allowing users to capture and document chemiluminesc ent bl ot image s,
including Western blots.
The TS2 Imagers are self-contained, light-tight imaging systems with a built-in 15.6” touch screen and
computer and TS2 Software for image acquisition.
The darkroom has a UV-blocking gel viewer window, built-in overhead epi white lighting, a UV
transilluminator and a five-position slide-out emission filter wheel with an ethidium bromide (EtBr) emission
filter included as standard. Save images to the internal hard drive, to an external USB storage device or to a
network drive for later quantitative analysis or enhancement for publication.
UVP’s VisionWorks
colony plates. VisionWorksLS requires an external computer and cannot be operated directly on the TS2’s
integrated computer.
*System/software configurations may vary by country. Contact UVP or authorized distributor for details.
TS2
Imagers 3
TS2
Imager is a high resolution imaging system capable of capturing and documenting
TS2
Imager is equipped with a cooled,
®
LS Analysis software is included* with all TS2 Imagers for analysis of gels, blots and
GelDoc-It
Camera and Lens
Hood
15.6” Touch Screen
Computer
Computer Power
Wide Access Door
USB Access Port
Built-In Overhead
White Lights
Five Position Slide-
Wheel
UV Gel Viewer
Window
Transilluminator on
Roll-Out Tray
UV Safety Interlock
Switch & Override
Black Chemi Tray
versions only)
BioLite™ Access Port
Power Indicator
Lights
Stylus with Adhesive
Holder (Not Shown)
TS2
and ChemiDoc-It
TS2
Imagers 4
System Components
Refer to the packing slip and pictured components for specific parts and components included with the
system.
Built Into Darkroom
Out Emission Filter
(ChemiDoc-It
TS2
GelDoc-It
TS2
and ChemiDoc-It
TS2
Imagers 5
Specifications
Power Requirements: 100/115V, 50/60Hz; 3.1 Amps at 120 Volts
230V, 50/60Hz; 1.55 Amps at 230 Volts
Mains supply voltage fluctuations are not to exceed 10 percent of the nominal
supply voltage
Pollution Degree: 2
Installation Category: II
Altitude: Up to 2000m
Ambient Temperature: 5°C to 40°C
Humidity: Maximum relative humidity of 80% for temperatures up to 31°C, decreasing
linearly to 50% maximum relative humidity at 40°C
Built-In Touch Screen Computer
Operating System: Windows® 7, 64-Bit
Connectivity Ports: 2 USB (side of system)
4 USB, VGA and Ethernet (rear of system)
Wireless Networking Capability: 802.11 b/g/n
USB Flash Drive Capacity: 2 GB (minimum)
Internal Hard Drive: 250 GB (minimum)
Software: TS2 (Touch Screen) Software
Cameras and Lenses
GelDoc-It
CCD camera with a resolution of 2.0MP (1600x1200). The GelCam 310 is equipped with a 12.5-75mm f/1.2
optical zoom lens.
ChemiDoc-It
scientific-grade monochrome CCD camera. Both cameras are Peltier cooled and offer full 16-bit file bit
depth:
All camera settings are fac tory pre-set for optimum performance when viewing gels, films or membranes
under low light level condi tions. Contact UVP Technical Support prior to making any adjustments to internal
camera settings.
TS2
: The GelDoc-It
TS2
: The ChemiDoc-It
The BioChemi 510 camera is a 2.1MP unit with Peltier cooling to 35°C below ambient. The
BioChemi 510 has a peak quantum efficiency of 50% and is capable of binning from 1x1 to 8x8.
This camera is equipped with a 12.5-75mm f/1.2 optical zoom lens.
The MegaCam 810 camera is an 8.1MP camera (3296x2472) with Peltier cooling to 35°C below
ambient. The MegaCam 810 has a peak quantum efficiency of 50% and is also capable of binning
from 1x1 to 8x8. This camera is equipped with either a 50mm f/1.2 lens or a 30mm f/1.4 lens, both
of which have a fixed focal length (non-optical zoom capable).
TS2
is equipped with the GelCam 310 camera, a scientific-grade monochrome
TS2
is equipped with either the MegaCam 810 or BioChemi™ 510
Ethidium Bromide (EtBr) Emission Filter
The ethidium bromide (50mm2) UV-blocking bandpass interference filter blocks UV and IR radiation emitted
from the transilluminator. The filter is placed in the slide-out filter wheel assembly on the side of the Imager.
The filter allows visuali zation of fluorophores from 580-630nm, targeting the ethidium bromide emission peak
of 605nm.
Additional filters are available for other specific fluorophores, including custom filters. Filters can also be
removed when imaging non-fluorescent media (inc luding chemiluminescent blots, protein gels, colony
plates, etc.) in order to produce brighter images. Contact UVP for ordering information.
GelDoc-It
Fluorescent Focus Target
TS2
and ChemiDoc-It
Darkroom
The darkroom is light tight to provide optimal imaging conditions. Darkroom features include:
• Epi (overhead) LED white light
• Roll-out transil luminato r tray
• UV-safe gel viewer window built into the darkroom door
• Five position emission filter wheel
• Brackets and built-in power ports for installing optional epi UV modules
• Brackets for installing optional high-intensity halogen or xenon BioLite™ epi light guides
• Built-in power jump er cable for transilluminator
• Power cord for optional LED White Light Plate
• UV safety interlock switch with manual override to disable UV transillumination and optional UV epi
illumination when darkroom door is opened
Transilluminator
The GelDoc-It
transilluminator models. UVP offers a variety of transilluminator configurations, including Benchtop models
with multiple wavelengths and variable intensities, as well as the highly uniform, pate nted Fi rstLi ght
transilluminator.
Note: For UV protection and to extend the life of the UV transilluminator, the system incorporates a
customizable transillum ina tor shut off timer built into the software. For additional information, refer to the
Lighting section of this manual.
TS2
and ChemiDoc-It
LCD Touch Screen
The GelDoc-It
computer. The touch screen allows the user to perform a variety of tasks, including previewing, capturing,
saving and printing images, as well as selecting preference options, without the use of an external mouse or
keyboard. The screen can be pressed by finger or with the included s tylus.
For users who prefer not to use the touch screen interface, an external keyboard and mouse are included as
standard. These components can be plugg ed into any avail a ble system USB ports.
TS2
TS2 Software
Image acquisition and hardware functions for the GelDoc-It
and ChemiDoc-It
Screen) Software interface. In addition to image preview, capture
and save functions, the TS2 Software controls camera and lens
functions (exposure, aperture, focus and zoom, where
applicable), image printing, lighting and filter selection, and other
user settings.
TS2
Imagers 6
TS2
Imagers can accommodate UVP’s Benchtop and FirstLight®
and ChemiDoc-It
TS2
Imagers are controlled by the TS2 (Touch
TS2
Imagers contain a fully integrated 15.6-inch color touch screen
TS2
TS2 Software Screen
Fluorescent Focus Target
The UVP Fluorescent Focus Target fluoresces when placed on a
UV transilluminator or when exposed to overhead UV. The Target
provides sharp fluorescent images to aid in adjusting the lens and
camera settings for ideal imaging results.
GelDoc-It
LED White Light Plate
BioLite MultiSpectral Light Source
TS2
and ChemiDoc-It
Optional Equipment
UVP offers a variety of optional equipment to support the needs of varying laboratory environments. Refer to
Replacement Parts and Accessories at the end of this manual for optional equipment part numbers.
BioLite MultiSpectral Light Source
The BioLite™ MultiSpectral Light Sour ce uti liz es high
intensity xenon or halogen lighting in conj unct io n wit h fiber
optic guides to a supply powerful, directed illumination to a
variety of fluorescent stained samples. A wide range of
excitation and emission filters enable a wide spectral range
of wavelengths, including red, green, blue and NIR.
Thermal Printer
The thermal printer provides archive quality, 256 grayscale
prints and five optional cost-effective print size s.
TS2
Imagers 7
Thermal Printer
UV Modules for Epi (Overhead) Lighting
A set of two 4-watt ultraviolet modules can be connected
inside the darkroom to provide epi UV illumination. These
modules can be switched on or off in t he Lighting menu
within the TS2 Software a nd c an also be remov ed fr om the
darkroom and used as standalone handheld lamps (as seen
in the image to the right).
LED White Light Plate
The LED White Light Plate emits high uniformity with less
than 5% coefficient of variance (CV). Plug the LED White
Light Plate directly into the power supply within the darkroom
and select “White Light Plate” under the Lighting menu
within the TS2 Software.
Epi UV Module
GelDoc-It
TS2
and ChemiDoc-It
TS2
Imagers 8
Converter Plates
An alternate to the LED White Light Plate, the UV/White
Converter Plate allows imaging of non-fluorescent sta ined
media with an ultraviolet transilluminator. The converter plate
is specially coated to convert 302nm UV to white light rather
than using a separate white light box.
The Visi-Blue™ Converter Plate (not shown) converts UV
to a safe 460-470nm wavelength desi gned for use with blue
excitation samples and SYBR Green, SYPRO Orange and
GFP stains.
UV/White Converter Plate
VisionWorks®LS Analysis Software
All TS2 systems include* a copy of VisionWorksLS Software for analysis of gels, plates and
membranes. The software features image enhancement, complete anal ysis tools and reporting
capabilities, and is ideal for users who require image analysis functions in addition to the standard
image acquisition capabilities of the TS2 software.
NOTE: Software must be installed and operated on an external computer.
*System/software configurations may vary by country. Contact UVP or authorized distributor for details.
GelDoc-It
TS2
and ChemiDoc-It
TS2
Imagers 9
Setup Instructions
Components
When unpacking the GelDoc-It
1. GelDoc-It
2. Ethidium bromide (EtBr) emission filter
3. Transilluminator
4. Power cable
5. USB flash drive (8 GB minimum)
6. Keyboard and mouse
7. VisionWorksLS Software (if included; varies by country)
8. Supporting documentation
When unpacking and setting up the darkroom, two people are required to move the darkroom.
Place the darkroom on a flat surface which can provide adequate support for up to 100 pounds.
WARNING: Do not attempt to perform any setup procedures while the system is plugged in or powered on
unless otherwise instructed.
CAUTION: Do not install the system in areas with high moisture, dust or high temperatures. Keep the
equipment away from motors or any other large magnetic equipment. This system is designed for indoor use
only.
TS2
or ChemiDoc-It
TS2
and ChemiDoc-It
TS2
system
TS2
, the following items will be included:
Connecting the Power Cables
1. Plug the main power cable into the back of the darkroom and the
other end into a surge-protected power outlet.
Note: It is recommended to leave the power swi tch on the back of
the system in the ON position except when the system will not be
used for an extended period of time (one day or longer).
Note: Do not position the system so that it is difficult to access the
power cable and operate the main power switch at the back of the unit.
2. Inside the darkroom, plac e the transilluminator on the roll-out tray. Connect the transilluminator to the
internal power jumper cable. Ensure that the green power switch on the front of the transilluminator unit
is in the ON position and that the desired wavelength or intensity is selected.
Note: For UV protection and to extend the life of the UV transilluminator, the s ystem incorporates a
customizable transilluminator shutoff timer built into the software. For additional information, refer to
Touch Screen Interface in this manua l.
3. If insta lling the LED White Light Plate, place the plate on top of the UV transilluminator and connect the
power cord coming from insi de the darkroom to the back of the Plate.
4. If insta lling epi UV modules, place the modules in the brackets located at the top of the darkroom. Plug
the modules into the outlets provided inside the darkroom. Place the power switches located on the
modules in the ON position.