The amber cover,
Models include a control knob for
Power switch
UVP’s long life filt er s are 21x26cm and 20x40cm

Introduction

Introduction
Visi-Blue™ Transilluminators convert 365nm UV to 460-470nm blue light, emitting no harmful UV energy. Visi-Blue Transilluminators are designed for use with GelStar®, GFP, SYBR® green, Vistra Green, SYPRO® Orange and Ethidium Bromide stains. As compared to UV, the blue light can transmit through almost any transparent laboratory equipment (plastic, glass, acrylic, etc.). This is essential when monitoring and detecting DNA migration and protein expression in “real time.” When used in imaging applications, use the proper emission filter to eliminate/reduce the background.
The amber colored cover blocks blue light trans mi ss ion and allow s visu alization of all media above 500nm.
Visi-Blue Transilluminators feature:
included with the transilluminator, blocks blue light and allows visualization of all media above 500nm. The cover is hinged and adjustable to varying heights.
available in two sizes:
Specifications
variable intensity selection: High, Medium or Low
Visi-Blue Transilluminators are designed with variable intensity settings. Units are equipped with an electronic ballast. This manual covers the VB-26V and VB-40V models.
VB-26V Dimensions: 14”W x 11”D x 4.8”H (356 x 279 x 122mm) Height includes cover VB-40V Dimensions: 19.13” W x 13.25” D x 5.63” H (486 x 337 x 143mm) Height includes cover
Part Wave- No. of Intensity
Model Number length Volts/Hz Filter Size Tubes Style
VB-26V 95-0461-01 460-470nm 100-115V/60Hz 21 x 26cm 4 x 8W Variable VB-26V 95-0461-02 460-470nm 230V/60Hz 21 x 26cm 4 x 8W Variable
VB-40V 95-0433-01 460-470nm 100-115V/60Hz 20 x 40 cm 4 x 25W Variable VB-40V 95-0433-02 460-470nm 230V/60Hz 20 x 40 cm 4 x 25W Variable
81-0250-01 Rev C
Page 3
Visi-Blue Transilluminators Page 3
Transilluminator Operation
Set Up
Place the transillum inator on a level wor k surface. Be sure that a n air space exist s around
the bottom of the work surface. This space allows for proper air circulation through the unit.
Plug the female end of the power cord into the transilluminator. For 230 volt models, or
those requiring spec ial p o w er c or d conn ec tor s , ensur e that t he proper configuration of male connector or plug is properly connected to the power cord.
Plug the male end of the power cord into a properl y grounded electrica l outlet. The proper
voltage of the transilluminator is found on the product information label.
The transilluminator may be equipped with a UV Blocking Cover. Remove the brown
protective paper fr om the cover. Insert the bracket pin s on the cover into the holes on the front of the transil luminator. The cover is adj ust a ble t o var yin g a ng les f or ac ces s to the f ilter surface.
Using the Transilluminator
Place gel/sample on the filter area. It is recommended to place the gels on a Gel-Tray to protect the filter s urface from cuts and scratc hes. It is recommended that glov es be worn to prevent contact with gel and staining agents.
Press the ON/OFF switch to ON. The UV tubes within the unit wi l l g low beneath the filter. Use the variable intensity settings as follows:
High: Allows for UV excitation of fluorophores on gels for routine photography and for
excitation of gels with low sample concentration
Medium: Excellent for viewing and quick single-band exc ision Low: Allows for positio ning and preparation of gels, excising multiple bands and focusing
for photography
After viewing/photographing the sample, turn the transilluminator off.
Cleaning and Care of the Transilluminator
Clean unit surface with a damp soft cloth or sponge. Never use abrasive cleaners which can damage the filter surface.
To protect the filter glass and minimize moisture and liquids on the glass, it is recommended to use a UV transmitting Gel-Tray. Refer to the Replacement Parts for ordering information.
Replacing Tubes in the Transilluminator
1. Disconnect the transilluminator from the electrical supply.
2. Remove the filter cover: Use a Phillips head screwdriver to remove the four screws on the sides of the unit. Lift the filter cover off the unit.
NOTE: When powered on, the light tubes within the Visi-Blue transilluminators emit longwave UV (365nm). UV is a powerful source of UV radiation that will cause damage to unprotected eyes and skin. As a result, Visi-Blue transilluminators should NOT be operated when the filter cover is removed!
81-0250-01 Rev C
Page 4
Visi-Blue Transilluminators Page 4
Call (800) 452-6788 or (909) 946-
7:00 am and 5:00 pm, PST.
Call +44(0) 1223-420022, and ask for
5:30 pm.
3. Remove the reflectors on the left and right sides of the unit. Slide the reflectors up out of the unit.
4. Remove the tube: Carefully rotate the tube 90° and slide out of the socket. Replace with a new tube by sliding the tube into the socket and rotating 90° into place.
5. Insert the reflectors back into place and reattach the filter cover.
Maintenance/Repair/Technical Assistance
Replacement Parts/Accessories
For replacement parts or components not shown here, call UVP Customer Service or place of purchase. Have the transilluminator model number available when you call.
Replacement Part Description Part Number
Filter Assembly (VB-26V) 38-0313-06 Filter Assembly (VB-40V) 38-0215-01 Cover, Amber (VB-26V) 19-0170-04 Cover, Amber (VB-40V) 19-0171-02 Tube, 8 Watt, 365nm UV (VB-26V) 34-0031-01 (Qty. 4 Required) Tube, 25 Watt, 365nm UV (VB-40V) 34-0060-01 (Qty. 4 Required) Ballast, electronic, 8 watt (VB-26V) 42-0067-04 (115V) 42-0067-06 (230V) Ballast, electronic, 25 watt (VB-40V) 42-0067-02
Accessories Description Part Number
Gel-Ruler, UV Fluorescing 85-0003-01 Gel-Cutter 85-0002-01 Gel-Scooper 85-0006-01 Gel-Tray, UV Transmitting, Sm. 11.5”W x 9”D (29 x 23cm) 85-0007-01 Gel-Tray, UV Transmitting, Lg. 16.5”W x 10.5”D (42 x 27cm) 85-0005-01
Technical Support
Note: A Returned Goods Authorization (RGA) number must be obtained from UVP Customer Service
before returning any product. UVP offers free lifetime technical support on all of its products. Should you have any questions regarding the
product’s use, operation or repair, contact UVP’s offices at the locations below, or visit www.uvp.com.
If you are in North America, South
America, East Asia or Australia:
If you are in Europe, Africa, the
Middle East of Western Asia:
3197, and ask for Customer Service
during regular business days, between
Fax Customer Service, and send it to
Write to: UVP, LLC 2066 W. 11th
Street, Upland, CA 91786 USA
E-mail your message to:
info@uvp.com
(909) 946-3597
Customer Service during regular
business days between 9:00 am and
E-mail your message to: uvp@uvp.co.uk
Fax Customer Service, and send it to:
+44(0) 1223-420561
Write to: Ultra-Violet Products Ltd
Unit 1, Trinity Hall Farm Estate, Nuffield
Road, Cambridge CB4 1TG UK
81-0250-01 Rev C
Page 5
Visi-Blue Transilluminators Page 5
Warranty
UVP, LLC. warrants its Ultraviolet Transilluminators to be free of detects in materials and workmanship for a period of two (2) years from date of purchase. The foregoing warranty of UVP shall be of no force and effect if buyer has modified or damaged the product. Tubes and filters are warranted for 90 days.
All warranties or merchantability and fitness for any purpose and all other warranties, expressed or implied, except those expressly set forth herein, are deemed waived and excluded.
UVP’s duty under the warranty is limited to replacement and/or repair of the defective part at the option of UVP, LLC. UVP shall not be liable for any expenses or damages incurred by the purchaser except as expressly set forth herein, and in no event shall UVP be liable for any special, incidental or consequential damages of any kind. This warranty does not supersede any statutory rights that may be available in certain countries.