INF155/185/215 • IR Thermometers
Designed to offer technicians a clear choice
among a blurred array of options in today’s
market. With three instruments to choose from,
The Scout series has a solution best suited for any
application, whether it’s quick spot checks at close
range or sampling extreme temperature ranges
in environments too hazardous or too remote to
approach. All three are a reliable way to check,
locate, and monitor temperature variances and are
perfect for HVAC/R, electrical, industrial, facility,
residential, marine, or automotive diagnostics and
maintenance.
Equipment INF155 INF185 INF215
Distance to Spot Ratio 10:1 12:1 30:1
Temperature Range -58~750˚F -76~932˚F -76~1400˚F
Worklight - White UV
Contact Probe Input - √ √
MIN/MAX/Diff/AVG MAX only √ √
Adjustable Emissivity - √ √
Hi/Lo Alarm - √ √
Auto Off √ √ √
Carry Case √ √ √
Backlit Display √ √ √
Comfort Grip Handle √ √ √
3 year warranty √ √ √
Specifications
Measurement Non-Contact
INF155
Temperature -58˚ to 750˚F (-50˚ to 400˚C)
Accuracy ±2% of reading or 4˚F (2˚C) whichever is greater
Distance to Spot 10 : 1
Measurement Non-Contact K-type probe
INF185
Temperature -76˚ to 932˚F -83.2˚ to +1999˚F
(-60˚ to +500˚C) (-64˚ to 1400˚C)
Accuracy ±1.8˚F (1.0˚C) ±1% of reading or
1.8˚F (1.0˚C)
(Target temp = 59˚~95˚F) (Ambient temp = 77˚F) (Test ambient temp = 73±6˚F)
Accuracy ±2% of reading or 4˚F (2˚C) ±1% of reading or
1.8˚F (1.0˚C)
(Target temp = -28˚~58˚F/96˚~932˚F) (Ambient temp = 73±3˚F) (Test ambient temp = 73±6˚F)
Distance to Spot 12 : 1
INF215
Temperature -76˚ to 1400˚F -83.2˚ to +1999˚F
(-60˚ to +760˚C) (-64˚ to 1400˚C)
Accuracy ±1.8˚F (1.0˚C) ±1% of reading or
1.8˚F (1.0˚C)
(Target temp = 59˚~95˚F) (Ambient temp = 77˚F) (Test ambient temp = 73±6˚F)
Accuracy ±2% of reading or 4˚F (2˚C) ±1% of reading or
1.8˚F (1.0˚C)
(Target temp = -28˚~58˚F/96˚~1400˚F) (Ambient temp = 73±3˚F) (Test ambient temp = 73±6˚F)
Distance to Spot 30 : 1
Common
Resolution (-9.9~199.9˚F) 0.1˚F (0.1˚C)
Response Time (90%) 1 second
Operating Range 32˚ to 122˚F (0˚ to +50˚C)
Emissivity 0.95 fixed INF155 / Adjustable INF185/INF215
Battery 2 “AAA” Alkaline
Battery Life Typ. 18 hr/14 hrs continuos use
Dimensions 3.25” (w) x 7” (H) x 1.75” (D)
Weight INF155/INF185 7 oz./INF215 7.9 oz.
Auto Shut Off 15 second idle
Note: INF185 and INF215 only. Under the electromagnetic field of 3V/m from 200 to
600 MHz, the maximum error is 18°F or 10˚C.
Distributed By:
1-800-547-5740 • Fax: (503) 643-6322
www.ueitest.com • Email: info@ueitest.com
IN CANADA
Vancouver: Phone: 1-877-475-0648 • (604) 278-4511 • Fax: (604) 278-8299
Toronto: Phone: 1-877-475-0648 • Fax: (905) 238-5117
IN EUROPE
Phone: +44 1707 375550 • Fax: +44 1707 393277
Copyright © 2007 UEi Specifications are subject to change without notice. L670 CENV 5K 4/09
PLEASE
RECYCLE