Universal Enterprise CH2 User Manual

DL279KIT
Clamp-On Meter Kit
DL279 (PHOENIX II) Clamp-On Meter
• Detachable Clamp Head
• Worklight
• 40MΩ Resistance/Continuity
• 4000µF Capacitance
• -40 ~ 752°F Temperature (K type)
• µA for Flame Safeguard
• Non-Contact Voltage
• Diode & MIN/MAX
• Magnetic Mount
• Dual Backlight Display
• Test Lead Storage
• Test Lead Holder on Clamp Head
• Data hold
• Auto Off
• Three year limited warranty
CH2 (The HOOK) Extended Clamp Head
• Measures 100A AC
• Easily reaches into tight spaces
• Patent pending hook design shields readings from adjacent wires
• Features a worklight for dark work spaces
• Works exclusively with The Phoenix Clamp Meter Series
• Three year limited warranty
A
LL
Y
OU
N
EED
F
OR
HVAC/R A
PPLICATIONS
Copyright © 2007 UEi Specifications are subject to change without notice. L690 5/07
DL279KIT • Clamp-On Meter Kit
Distributed By:
1-800-547-5740 • Fax: (503) 643-6322 www.ueitest.com • Email: info@ueitest.com
IN CANADA
Vancouver: Phone: 1-877-475-0648 • (604) 278-4511 • Fax: (604) 278-8299 Toronto: Phone: 1-877-475-0648 • Fax: (905) 238-5117
IN EUROPE
Phone: +44 1707 375550 • Fax: +44 1707 393277
PLEASE
RECYCLE
DL279 Specifications
The DL279 – All you need for HVAC/R Applications. The Phoenix Series II offers the highest combination of function, features, and safety offered in a meter today. Combined with The Hook extended clamp head, no contractor will have to compromise their safety, efficiency, or comfort.
AC Amps Measurement - Jaw Input (45Hz to 400Hz)
DC Low Amps Measurement (test lead input)
AC Low Amps Measurement (test lead input)
DC Volts Measurement
AC Volts Measurement (45Hz to 400Hz)
Ohms Measurement
Diode Test
Capacitance Measurement
Temperature Measurement
Frequency Measurement
Minimum frequency: 0.5Hz, DC V offset should be zero
Sensitivity: > 1.0V rms
Duty (%) Cycle Measurement
0.5Hz to 100KHz (pulswidth > 2µ sec)
Continuity Measurement
Range Resolution Accuracy Overload Protection
40A 0.01A ±2.9% +15 dgts 600V 400A 0.1A ±1.9% +8 dgts
Range Resolution Accuracy Overload Protection
400µA 0.01µA ±1.2% +3 dgts 2000µA / 600V 2000µA 0.1µA
Range Resolution Accuracy Overload Protection
400µA 0.01µA ±2.0% +5 dgts 2000µA / 600V 2000µA 0.1µA ±1.5% +5 dgts
Range Resolution Accuracy Overload Protection
400mV 0.1mV ±0.5% +4 dgts 600V 4V 1mV 40V 10mV 400V 100mV 1000V 1V ±0.8% +10 dgts
Range Resolution Accuracy Overload Protection
4V 1mV ±2.0% +5 dgts 600V 40V 10mV 400V 100mV 750V 1V
Range Resolution Accuracy Overload Protection
400Ω 100mΩ ±1.0% +4 dgts 600V 4kΩ 1Ω 40kΩ 10Ω 400kΩ 100Ω 4MΩ 1kΩ 40MΩ 10kΩ ±2.0% +4 dgts
Range Open Circuit Voltage Test Current (typical) Overload Protection
2.0V < 3.0V DC 0.25mA 600V
Range Resolution Accuracy Overload Protection
40nF 0.01nF ±3.5% +6 dgts 600V 400nF 0.1nF 4µF 0.001µF 40µF 0.01µF 400µF 0.1µF 4000µF 1µF
Range Resolution Accuracy Overload Protection
-22˚ to 14˚F 0.1˚F ±5.4˚F 30V (-30˚ to -10˚C) (0.1˚C) (±3.0˚C) 15˚ to 752˚F 0.1˚F ±1.0% +3.6˚F (-9˚ to 400˚C) (0.1˚C) (±1.0% +2.0˚C)
Range Resolution Accuracy Overload Protection
9.999Hz 0.001Hz ±0.1% +4 dgts 600V
99.99Hz 0.01Hz
999.9Hz 0.1Hz
9.999kHz 1Hz
99.99kHz 10Hz
Range Accuracy Overload Protection
01. to 99.9% ±(0.2% per kHz +0.1%) +5 count 600V
Open Circuit voltage <2.7V Overload Protection
Threshold Approximately <20Ω 600V