Triton T80 Easi-Fit Instruction manual

T80 Easi-Fit
electric shower
Installation and
operating
instructions
Installers p lease no te these Instruc tIons
are to b e left w Ith the user
The shower installation MUST be carried out by a suitably qualified person, in the sequence of this instruction book.
EC Registered Design No. 001902388-0005 to 0007
2180858I - Sept 2015
Patents Pending: GB 2489547 GB 2495343
Patent: GB 2481878
INTRODUCTION - PLEASE READ
PLEASE READ THIS IMPORTANT SAFETY INFORMATION
Products manufactured by Triton are safe and without risk provided they are installed, used and maintained in good working order in accordance with our instructions and recommendations.
WARNING: DO NOT operate shower if frozen, or suspected of being frozen. It must thaw out before using.
DO NOT operate the unit if the showerhead or spray hose becomes damaged. DO NOT restrict flow out of shower by placing showerhead in direct contact with your body. DO NOT operate the shower if water ceases to flow during use or if water has entered inside
the unit because of an incorrectly fitted cover.
WARNING: If restarting the shower immediately after stopping, be aware that a slug of hot water will be expelled for the first few seconds.
This book contains all the necessary fitting and operating instructions for your electric shower.
Care taken during the installation will provide a long, trouble-free life from your shower.
Triton recommend watching the short online *videos that cover electric shower basics before your installation - *(videos may not show the exact model purchased).
• What is an electric shower?
• Electrical requirements for electric showers
• Plumbing requirements for electric showers
• Kilowatt ratings explained
To view these videos visit: www.tritonshowers.co.uk/triton-products/product-videos.aspx
PLEASE USE THE FOLLOWING CHECK LIST TO AID YOUR INSTALLATION
Tick off as
SECTION
Check that the water supply will satisfy requirements .............................................. 1
1
SECTION
Check that water & cable entry points of the unit meet requirements ..................... 2
2
SECTION
Check that the electric supply will satisfy requirements ............................................ 3
3
SECTION
Siting of the shower .................................................................................................
4
SECTION
Plumbing installation ............................................................................................... 5
5
SECTION
Electrical installation ................................................................................................ 6
6
SECTION
Fit to the wall & connect the shower supplies .......................................................... 7
7
SECTION
Fitting the cover ...................................................................................................... 8
8
SECTION
ONLY Commission the shower in the way described ............................................ 9
9
SECTION
Familiarise yourself with the user operating instructions ........................................... 10
10
you complete
4
2
Products manufactured by Triton are safe and without risk provided they are installed, used and maintained in good working order in accordance with our instructions and recommendations.
WARNING: DO NOT operate shower if frozen, or suspected of being frozen. It must thaw out before using.
DO NOT operate the unit if the showerhead or spray hose becomes damaged. DO NOT restrict flow out of shower by placing showerhead in direct contact with your body. DO NOT operate the shower if water ceases to flow during use or if water has entered inside
the unit because of an incorrectly fitted cover.
WARNING: If restarting the shower immediately after stopping, be aware that a slug of hot water will be expelled for the first few seconds.
PLEASE READ THIS IMPORTANT SAFETY INFORMATION
IMPORTANT - GENERAL GUIDANCE NOTES
1 GENERAL
1.1 Isolate the electrical and water supplies before
removing the cover.
1.2 Read all of these instructions and retain them
for later use.
1.3 DO NOT take risks with plumbing or electrical
equipment.
1.4 Isolate electrical and water supplies before
proceeding with the installation.
1.5 The unit must be mounted onto the finished
wall surface (on top of the tiles). DO NOT tile up to or seal around ANY PART of the unit using silicone sealer after fixing to the wall. Special care must be taken NOT TO BLOCK OR SEAL ANY PRD VENTS ON THE UNIT.
1.6 Contact Customer Service (see back page), if
any of the following occur:
a) If it is intended to operate the shower at
pressures above the maximum or below the minimum stated.
b) If the unit shows a distinct change in performance. c) If the shower is frozen.
1.7 If it is intended to operate the shower in areas
of hard water (above 200 ppm temporary hardness), a scale inhibitor may have to be fitted. For advice on the Scale Inhibitor, contact Customer Service.
1.8 The showerhead must be cleaned regularly
with descalent to remove scale and debris, otherwise restrictions to the flow on the outlet of the unit will result in higher temperatures and could also cause the (PRD) Pressure Relief Device in the unit to operate.
1.9 This product is not suitable for mounting into
steam rooms or steam cubicles.
PLUMBING
2
2.1 The plumbing installation must comply with
Water Regulations, Building Regulations or any particular regulations as specified by Local Water Company or Water Undertakers and should be in accordance with BS EN 806.
2.2 The supply pipe must be flushed to clear debris before connecting to the shower unit.
2.3 DO NOT solder pipes or fittings within 300mm
of the shower unit, as heat can transfer along the pipework and damage components.
2.4 DO NOT fit any form of outlet flow control as
the outlet acts as a vent for the heater can.
2.5 DO NOT use excessive force when making
connections to the flexible hose or showerhead, finger tight is sufficient.
2.6 All plumbing connections must be completed before making the electrical connections.
2.7 This appliance MUST not be connected to the inlet supply by a hose-set.
3
ELECTRICAL
3.1 The installation must comply with BS 7671
‘Requirements for electrical installations’ (IEE wiring regulations), building regulations or any particular regulations as specified by the local Electrical Supply Company.
3.2 This appliance MUST be earthed.
3.3 In accordance with ‘The Plugs and Sockets etc.
(Safety) Regulations 1994’, this appliance is intended to be permanently connected to the fixed wiring of the electrical mains system.
3.4 Make sure all electrical connections are tight to prevent overheating.
3.5 A 30mA residual current device (RCD) MUST be installed in all UK electric and pumped shower circuits. This may be part of the consumer unit or a separate unit.
3.6 Switch off immediately at isolating switch if water ceases to flow during use.
3.7 Other electrical equipment i.e. extractor fans, pumps must not be connected to the circuits within the unit.
3.8 Switch off at isolating switch when not in use. This is a safety procedure recommended with all electrical appliances.
3.9 As with all electrical appliances it is recommended to have the shower and installation checked at least every two years by a competent electrician to ensure there is no deterioration due to age and usage.
WARNING
This appliance can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental
capabilities or lack of experience or knowledge if they have been
given supervision or instruction concerning use of the appliance
in a safe way and understand the hazards involved. Children may
not play with the appliance. Cleaning and user maintenance shall
not be made by children without supervision.
3
.
GENERAL ADVICE TO USERS
The following points will help you understand how the shower operates:
a. The electric heating elements operate at a
constant rate at your chosen power setting. It is the rate of the water passing through the heater can which determines the water temperature. (The slower the flow, the hotter the water becomes; the faster the flow, the cooler the water).
b. During winter, the mains water supply will be
cooler than in the summer. The flow rate will vary between seasons at any one temperature setting. At different times of the year you may have to adjust the position of the temperature control to maintain your desired temperature setting.
c. The stabiliser valve minimises variations in
shower temperature during mains water pressure changes. If changes in shower temperature are experienced during normal use, it will most likely be caused by the water pressure falling near to or below the minimum level. The drop in pressure may be due to water being drawn off at other points in the house whilst the shower is in use. If pressure drops appreciably below the minimum, the heating elements will automatically cut out.
NOTE: If ever the water becomes too hot and you cannot obtain cooler water, first check that the sprayplate in the showerhead has not become blocked.
DO NOT place items such as soap or shampoo bottles on top of the unit. Liquid could seep through the joint between the cover and backplate.
IMPORTANT ADVICE TO USERS
COMISSIONING ADVICE
When first installed the unit will be empty.
It is essential the unit should contain water
before the elements are switched on. It is
vital that the commissioning procedure
is followed. Failure to carry out this
operation will result in damage to the unit
and will invalidate the guarantee.
ADVISORY - CLEANING
It is recommended that all products
are cleaned using warm, soapy water.
DO NOT use abrasive or aggressive
chemical cleaning products as this may
affect the product surface nish and
invalidate your guarantee.
4
CONTENTS Page
INTRODUCTION IMPORTANT SAFETY INFORMATION (please read) Installation check list (please follow & complete)
GENERAL GUIDANCE NOTES GENERAL ADVICE TO USERS - CLEANING ADVICE
SPECIFICATIONS ............................................................................. 2
DIMENSIONS & CABLE/WATER ENTRY POINTS .............................. 3
ELECTRICAL REQUIREMENTS ....................................................... 4 - 5
INSTALLING THE SHOWER ................................................. 6 - 14
Siting of the shower ................................................................ 6 - 7
Plumbing installation .................................................................. 8
Electrical installation ................................................................... 9
Fit to the wall & connect shower supplies .............................. 9 - 13
Fitting the cover .................................................................... 13 - 14
COMMISSIONING PROCEDURE .........................................15
USER OPERATING INSTRUCTIONS ..................................... 16 - 18
Operating functions ....................................................................... 18
Cleaning the filter - installers & service engineers only ................... 19
Fault finding/Troubleshooting .................................................... 20 - 21
Spare parts ................................................................................ 22 - 23
SHOWER CONTROLS - QUICK USER GUIDE ............... Inside rear cover
UK Service Policy/UK Guarantee .............................................. Rear cover
To check the product suitability for commercial and multiple installations, please contact Triton’s specication advisory service before installation.
Telephone:
Facsimile:
024 7637 2222
024 7632 4504
E mail:
technical@tritonshowers.co.uk
1
SECTION
check list
1
Nominal power - rating at 240V Nominal power - rating at 230V
8.5kW – (40A MCB rating) 7.8kW – (40A MCB rating)
9.5kW – (40A MCB rating) 8.7kW – (40A MCB rating)
10.5kW – (45A MCB rating) 9.6kW – (45A MCB rating)
PLUMBING (see page 6 & 7 for water regulations)
Supply Source Mains pressure cold water only
SPECIFICATIONS
ELECTRICAL
Minimum running pressure and flow to the inlet of the shower for full performance
Maximum static pressure 1000 kPa (10 bar)
Maximum inlet temperature 28°C
Minimum inlet temperature 2°C
Inlet connection 15mm diameter
Outlet connection ½” BSP male thread
ABS Backplate, cover, controls, showerhead
Acetal Sprayplate
Minerally insulated corrosion resistant metal sheathing
STANDARDS and APPROVALS
Splashproof rating IPX4
Safety Complies with the requirements of current
100kPa (1.0 bar) at 8 litres per minute for
8.5kW & 9.5kW
150kPa (1.5 bar) at 11 litres per minute for 10.5kW
MATERIALS
Elements
British and European safety standards for household and similar electrical appliances
BEAB Complies with requirements of the British
Electrotechnical Approvals Board (BEAB)
CE Meets with Compliance with European
Community Directives (CE)
2
DIMENSIONS & ENTRY POINTS
check list
SECTION
2
Fig.1
Fig.2
DIMENSIONS
225mm 101mm
333mm
ENTRY POINTS
WATER
Left: Bottom, Back, Top & Side.
Right: Bottom, Back, Top & Side.
CABLE
Left: Bottom, Back & Top.
Right: Bottom, Back & Top.
PLEASE NOTE: Deviation from the
approved entry points will invalidate product specifications and warranty.
= Back
= Back
3
= Others
= Others
SECTION
Meter
Incoming
supply
fuse
Meter
tails
Consumer
unit
Pull cord
isolating switch
Shower
unit
Fuse or
MCB
RCD
(can be part of
consumer unit)
80A or 100A
main switch
MCB
30/32A
32A
40A
40A
40A
40/45A
45A
cartridge
fuse
30A
35A
35A
45A
45A
45A
45A
unit
rating
7.0kW
7.5kW
8.0kW
8.5kW
9.0kW
9.5kW
10.5kW
CIRCUIT PROTECTION
Triton Showers,
Triton Road, Nuneaton,
Warwickshire, CV11 4NR
xxxx
3
check list
ELECTRICAL REQUIREMENTS
ELECTRICAL REQUIREMENTS
WARNING!
THIS APPLIANCE MUST BE EARTHED
The installation, supply cable and circuit protection must conform with BS 7671 (IEE wiring regulations) and be sufcient for the amperage required.
The following notes are for guidance only: 1 The shower must only be connected to a
230-240V ac supply. If you are installing a shower with a kilowatt rating above 9kW, it is advisable to contact the local electricity supply company.
1.1 The electrical rating of the shower is shown on the rating label (Fig.3) within the unit.
2 Before making any sort of electrical
connection within the installation make sure that no terminal is live. If in any doubt, switch off the whole installation at the mains supply and remove the correct fuse.
3 The shower must be connected to its own
independent electrical circuit. IT MUST NOT be connected to a ring main, spur, socket outlet, lighting circuit or cooker circuit.
3.1 The electrical supply must be adequate for the loading of the unit and existing circuits.
4 Check your consumer unit (main fuse box)
has a main switch rating of 80A or above and that it has a spare fuse way which will take the fuse or Miniature Circuit Breaker (MCB) necessary for the shower (Fig.4).
4.1 If your consumer unit has a rating below 80A or if there is no spare fuse way, then the installation will not be straightforward and may require a new consumer unit serving the house or just the shower.
4.2 You will need to contact the local electricity company. They will check the supply and carry out what is necessary.
5 For close circuit protection DO NOT use a
rewireable fuse. Instead use a suitably rated Miniature Circuit Breaker (MCB) or cartridge fuse (see Table A).
5.1 A 30mA residual current device (RCD) MUST be installed in all UK electric and
pumped shower circuits. This may be part of the consumer unit or a separate unit.
W-006-A
Fig.3
Fig.4 Schematic of installation circuit
Table A
4
Continued
Note: Cable selection is dependent on
deratin
g
factors
Twin and earth PVC insulated cable
Current carrying capacity
In conduit
trunking
6mm²
38A
10mm²
52A
16mm²
69A
Installed in an insulated wall
6mm²
32A
10mm²
43A
16mm²
57A
Clipped direct
or buried in a
non-insulated
wall
6mm²
46A
10mm²
63A
16mm²
85A
SECTION
3
6 A 45 amp double pole isolating switch with
a minimum contact gap of 3 mm in both poles must be incorporated in the circuit.
6.1 It must have a mechanical indicator showing
when the switch is in the OFF position, and the wiring must be connected to the switch without the use of a plug or socket outlet.
6.2 The switch must be accessible and clearly
able, but out of reach of a person u cord of a cord operated switch, and should be placed so that it is not possible to touch the switch body while standing in a bath or shower cubicle. It should be readily accessible to switch off after using the shower.
7 Where shower cubicles are located in any
rooms other than bathrooms, all socket outlets in those rooms must be protected by a 30mA RCD.
8 The current carrying capacity of the cable
must be at least that of the shower circuit protection (see Table B).
8.1 To obtain full advantage of the power
provided by the shower, use the shortest cable route possible from the consumer unit to the shower.
8.2 It is also necessary to satisfy the disconnection
time and thermal constraints which means that for any given combination of current demand, voltage drop and cable size, there is a maximum permissible circuit length.
9 The shower circuit should be separated from
other circuits by at least twice the diameter of the cable or conduit.
9.1 The current rating will be reduced if the
cabling is bunched with others, surrounded by thermal loft or wall insulation or placed in areas where the ambient temperature is above 30°C. Under these conditions, derating factors apply and it is necessary to select a larger cable size.
9.2 In the majority of installations (see Table B), the cable will unavoidably be
placed in one or more of the above conditions. This being so, it is strongly recommended to use a minimum of 10mm cabling throughout the shower installation.
xed bath or shower, except for the
9.3 In any event, it is essential that individual
site conditions are assessed by a competent electrician in order to determine the correct cable size and permissible circuit length.
Table B
*The method below may be used by
installers to determine the approximate
size of the incoming cable.
2
6mm
1. Measure the width of an individual strand,
and half that measurment to find (r), e.g: 1.34mm ÷ 2 = (r) 0.67mm
2. Multiply (r) x (r) x 3.14,
e.g: (r) 0.67 x (r) 0.67 x 3.14 = 1.41mm
3. Multiply this by the number of wire strands
(usually 7), e.g: 1.41mm2 x 7 = 9.87mm2.
4. The number obtained would suggest
10mm2 wiring.
*PLEASE NOTE: If unsure, consult a qualified Electrician.
10mm
2
16mm
2
2
5
Isolating
stopvalve
Mains water supply
Shower unit
Mains electric supply
(via double pole switch)
Double
pole
isolating
switch
Separate permanently
connected supply
from consumer unit
SECTION
4
check list
Installation - SITING OF THE SHOWER
SITING OF THE SHOWER
The installation must be in accordance with Water Regulations/Bylaws - see page 2 for
water specifications
• If it is intended to operate the shower at
pressures above the maximum or below the minimum stated, contact Customer Service for advice.
• If the stated flow rates are not available,
it may not be possible to achieve optimum performance from the unit throughout the year.
• During periods of high ambient temperatures
it may be necessary to select the economy power setting to achieve your preferred shower temperature.
Fig.5 shows a typical system layout.
NOTE: The control knobs are an integral part of
the cover. Do not attempt to remove them.
• Lift the cover from the backplate and remove
the trimplate.
• Refer to (fig.6) for the correct siting of
the shower. Position the unit where it will NOT be in direct contact with water from the showerhead. Position the shower unit vertically.
• Allow enough room between the ceiling and
the shower to access the cover top screws.
• Mark out entry points and routing of the
water and electric supplies into the shower.
Fig.5
Diagrammatic view (not to scale)
6