This Installation Guide describes the hardware characteristics, installation methods and the points that should
be attended to during the installation. This Installation Guide is structured as follows:
Chapter 1 Introduction.
This chapter describes the external components of the switch.
Chapter 2 Installation.
This chapter illustrates how to install the switch.
Chapter 3 Lightning Protection.
This chapter illustrates how to prevent lightning damage.
Chapter 4 Connection.
This chapter illustrates how to do the physical connection of the switch.
Chapter 5 Configuration.
This chapter instructs you to configure the switch via Web Interface and CLI commands.
Appendix A Troubleshooting.
Appendix B Specifications.
Audience
This Installation Guide is for:
Network Engineer Network Administrator
Conventions
• The figures in Chapter 2 to Chapter 5 are for demonstration purposes only. Your switch may differ in
appearance from that depicted.
• This Guide uses the specific formats to highlight special messages. The following table lists the notice icons
that are used throughout this guide.
Remind to be careful. A caution indicates a potential which may result in device damage.
Remind to take notice. The note contains the helpful information for a better use of the product.
Related Document
The User Guide and CLI Reference Guide of the product are provided on the resource CD. To obtain the latest
product information, please visit the official website:
http://www.tp-link.com
5.1 Congure the Switch via GUI ..................................................... 25
5.2 Congure the Switch Using CLI ................................................ 26
IIContents
Appendix A Troubleshooting ——————————— 31
Appendix B Hardware Specications ———————— 32
Chapter 1 Introduction
1.1 Product Overview
T2700G-28TQ/T3700G-28TQ is TP-Link’s JetStream Stackable L2+/L3 Managed Switch, supporting
up to 4 SFP+ slots. T2700G-28TQ/T3700G-28TQ is ideal for large businesses, campuses or SMB
networks requiring an outstanding, reliable and affordable 10 Gigabit solution.
T2700G-28TQ/T3700G-28TQ supports stacking of up to 8 units, thus providing flexible scalability
and protective redundancy for your networks. Moreover, aiming to better protect your network,
T2700G-28TQ/T3700G-28TQ’s main power is removable. With the help of TP-Link’s RPS,
administrators can easily change its main power if it encounters some problems without shutting
down the switch, thus enabling your network to really enjoy the benefit of uninterrupted operation.
Supporting advanced features such as OSPF, VRRP, IGMP and PIM DM/SM, T3700G-28TQ can fully
implement resilient scalable networks, and T2700G-28TQ can be upgraded with the addition of a
layer 3 license to provide these layer 3 routing features as well.
Note:
Obtain the T2700G-28TQ Layer 3 License T2700G-28TQ-L1000 via the following steps
■
Buy a license key from a TP-Link authorized distributor.
■
Go to T2700G-28TQ page on TP-Link website, use the license key together with the switch S/N
and the MAC address for authentication to download the license T2700G-28TQ-L1000.
JetStream Stackable L2+/L3 Managed Switch
:
1.2 Appearance
■
Front Panel
The front panel of T2700G-28TQ/T3700G-28TQ is shown as the following figure.Here we take
T3700G-28TQ as an example.
Figure 1-1 Front Panel
Console Port
LEDs
10/100/1000Mbps
RJ45 Port
Console Port
Designed to connect with the serial port of a computer or terminal for monitoring and configuring
the switch.
SFP Port
SFP+ Port
Unit ID LED
01Introduction
JetStream Stackable L2+/L3 Managed Switch
LEDs
LEDStatusIndication
OnThe switch is powered on
Power
System
RPS
FAN
Master
Module
Link/Act
(Port 1-24)
21F-24F
OffThe switch is powered off or power supply is abnormal
FlashingPower supply is abnormal
FlashingThe switch works properly
On/OffThe switch works improperly
Green
On
Yel l ow
OffThe switch is not connected to any redundant power supply
GreenAll the fans work properly
Yel l owNot all the fans work properly
On
OffThe switch works as slave in the stack system
On(green)An Interface Card is connected to the switch and works properly
Flashing(yellow)An Interface Card is connected to the switch, but works improperly
OffNo Interface Card is connected to the switch
Green
Yel l ow
OffNo device is connected to the corresponding port
On
Flashing
On
Flashing Data is being transmitted or received
On
Flashing Data is being transmitted or received
Both the Power Supply Module and the redundant power supply
work properly
The
Power Supply Module
power supply works properly
The switch works as master in the stack system, or does not join
any stack system
A 1000Mbps device is connected to the corresponding port, but no
activity
A 10/100Mbps device is connected to the corresponding port, but
no activity
An SFP transceiver is connected to the corresponding port, and it is
connected to a device, but no activity
A 1000Mbps device is connected to the corresponding port and
transmitting data
works improperly, but the redundant
02
Introduction
25, 26
Off
On
Flashing
Off
An SFP transceiver is connected to the corresponding port, but it is
not connected to a device, or no SFP transceiver is connected
An SFP+ transceiver/cable is connected to the corresponding port,
and it is connected to a 10Gbps device, but no activity
A 10Gbps device is connected to the corresponding port and
transmitting data
An SFP+ transceiver/cable is connected to the corresponding port,
but it is not connected to a device, or no SFP+ transceiver/cable is
connected
LEDStatusIndication
An SFP+ transceiver/cable is connected to the corresponding port
On
Flashing
M1,M2
Off
of the Interface Card, and it is connected to a 10Gbps device, but no
activity
A 10Gbps device is connected to the corresponding port of the
Interface Card and transmitting data
No Interface Card is connected
No SFP+ transceiver/cable is connected to the installed Interface
Card
An SFP+ transceiver/cable is connected to the corresponding port
of the Interface Card, but it is not connected to a device
Port Feature
JetStream Stackable L2+/L3 Managed Switch
Model
T2700G-2 8TQ2414 (Combo)4 (2 fixed + 2 optional)
T3700G-28TQ2414 (Combo)4 (2 fixed + 2 optional)
10/10 0/1000M bps
RJ45 Port
Console
Port
1000Mbps
SFP Port
10Gbps SFP+ Port
10/100/1000Mbps Port
Port 1-24, designed to connect to the device with a bandwidth of 10Mbps, 100Mbps or
1000Mbps. Each has a corresponding Link/Act LED.
SFP Port
Port 21F-24F, designed to install the SFP transceiver. These four SFP transceiver slots are shared
with the associated RJ45 ports. The associated two ports are referred as a “Combo” port, which
means they cannot be used simultaneously, otherwise only RJ45 port works. The SFP ports
support 1000M SFP module connection only.
SFP+ Port
Port 25-26, designed to install the 10Gbps SFP+ transceiver or SFP+ cables. T3700G-28TQ also
provides an interface card slot on the rear panel to install the expansion card (TX432 of TP-Link
for example). If TX432 is installed, you get another two 10Gbps SFP+ ports.
Unit ID LED
Designed to display the stack Unit ID of the switch. For the switch that does not join any stack
system, it displays its default Unit ID. To modify the default unit number, please logon to the GUI
of the switch and go to Stack→Stack Management→Switch Renumber page.
03Introduction
JetStream Stackable L2+/L3 Managed Switch
■
Rear Panel
The rear panel of T2700G-28TQ/T3700G-28TQ is shown as the following figure.
Figure 1-1 Rear Panel (1)
Power
PS OK
Fault
Interface Card Slot
Grounding
Terminal
RPS Input
Connector
PSM150-AC
Power Suppl y
100-240V~ 50/60Hz 2.5A
Module
Note:
The Interface Card Slot and RPS Input Connector are shipped with protective covers.
Interface Card Slot
Designed to extend the interfaces. You can select a TP-Link Interface Card (TX432 for example)
for your switch if needed. For how to install an Interface Card, please refer to 3.4 Installing &
Removing the Interface Card.
Grounding Terminal
The switch already comes with lightning protection mechanism. You can also ground the switch
through the PE (Protecting Earth) cable of AC cord or with Ground Cable. For detailed information,
please refer to Chapter 4 Lightning Protection.
RPS Input Connector
Designed to connect the RPS (Redundant Power Supply). You can selected an RPS of TP-Link
(RPS150 for example) for your switch if needed. For how to install an RPS, please refer to 5.6 Power on via Redundant Power Supply.
04
Power Supply Module
The AC Power Supply Module PSM150-AC is installled in the switch. The malfunctioned PSM150AC can be replaced with a TP-Link power supply module of the same model. Its input voltage is
100-240V~ 50/60Hz.
The AC Power Supply Module is fully hot swappable, helping to ensure no system interruption
during installation or replacement. For how to install/remove the Power Supply Module, please
refer to 3.3 Installing & Removing the Power Supply Module.
Caution:
Please use the provided power cord.
With all the protective covers removed and the Interface Card (TX432 for example) inserted, the rear
panel of T2700G-28TQ/T3700G-28TQ is shown as the following figure.
Introduction
Figure 1-2 Rear Panel (2)
JetStream Stackable L2+/L3 Managed Switch
TX432
Module
M1
M2
SFP+
SFP+
CLASS 1 LASER PRODUCT
Power
PS OK
Fault
PSM150-AC
100-240V~ 50/60Hz 2.5A
05Introduction
JetStream Stackable L2+/L3 Managed Switch
40℃
Chapter 2 Installation
2.1 Package Contents
Make sure that the package contains the following items. If any of the listed items is damaged or
missing, please contact your distributor.
One Switch
One Resouce CD
One Power Cord and one Console
Cable
Two Mounting Brackets and the
This Installation Guide
Business Networking Solution
Installation Guide
Fittings
2.2 Safety Precautions
To avoid any device damage and bodily injury caused by improper use, please observe the following
rules.
■
Safety Precautions
■
Keep the power off during the installation.
■
Wear an ESD-preventive wrist strap, and make sure that the wrist strap has a good skin contact and
is well grounded.
■
Use only the power cord provided with the switch.
■
Make sure that the supply voltage matches the specifications indicated on the rear panel of the
switch.
■
Ensure the vent hole is well ventilated and unblocked.
■
Do not open or remove the cover of the switch.
■
Before cleaning the device, cut off the power supply. Do not clean it by the waterish cloth, and never
use any other liquid cleaning method.
06
■
Temperature/Humidity
Installation
Site Requirements
0℃
JetStream Stackable L2+/L3 Managed Switch
Please keep a proper temperature and humidity in the equipment room. Too high/low humidity may
lead to bad insulation, electricity leakage, mechanical property changes and corrosions. Too high
temperature may accelerate aging of the insulation materials and can thus significantly shorten
the ser vice life of the device. For normal temperature and humidity of the device, please check the
following table.
EnvironmentTemperatureHumidity
Operating0℃ to 40
℃
Storage-40℃ to 70
℃
10% to 90%RH Non-condensing
5% to 90%RH Non-condensing
Clearness
The dust accumulated on the switch can be absorbed by static electricity and result in poor contact
of metal contact points. Some measures have been taken for the device to prevent static electricity,
but too strong static electricity can cause deadly damage to the electronic elements on the internal
circuit board. To avoid the effect of static electricity on the operation of the Switch, please attach
much importance to the following items:
■
Dust the device regularly, and keep the indoor air clean.
■
Keep the device well grounded and ensure static electricity has been transferred.
Electromagnetic Interference
Electronic elements including capacitance and inductance on the device can be affected by
external interferences, such as conducted emission by capacitance coupling, inductance coupling,
and impedance coupling. To decrease the interferences, please make sure to take the following
measures:
■
Use the power supply that can effectively filter interference from the power grid.
■
Keep the device far from high-frequency, strong-current devices, such as radio transmitting station.
■
Use electromagnetic shielding when necessary.
Lightening Protection
Extremely high voltage currents can be produced instantly when lightning occurs and the air in the
electric discharge path can be instantly heated up to 20,000℃. As this instant current is strong
07Installation
JetStream Stackable L2+/L3 Managed Switch
enough to damage electronic devices, more effective lightning protection measures should be
taken.
■
Ensure the rack and device are well earthed.
■
Make sure the power socket has a good contact with the ground.
■
Keep a reasonable cabling system and avoid induced lightning.
■
Use the signal SPD (Surge Protective Device) when wiring outdoor.
Note:
For detailed lightning protection measures, please refer to Chapter 3 Lightning Protection.
Installation Site
When installing the device on a rack or a flat workbench, please note the following items:
■
The rack or workbench is flat and stable, and sturdy enough to support the weight of 5.5kg at least.
■
The rack or workbench has a good ventilation system. The equipment room is well ventilated.
■
The rack is well grounded. Keep the power socket less than 1.5 meters away from the device.
2.3 Installation Tools
■
Phillips screwdriver
■
ESD-preventive wrist wrap
■
Cables
Note:
These tools are not provided with our product. If needed, please self purchase them.
2.4 Installation & Connection Flow
The switch provides two interfaces to install the swappable Power Supply Module and Interface
Card, and one interface to connect to Redundant Power Supply. The switch has already been
installed with a Power Supply Module PSM150-AC, and you can also self-purchase the Interface
Card/Redundant Power Supply if needed.
The Installation & Connection flow is shown as the following figure.
08
Installation
Loading...
+ 28 hidden pages
You need points to download manuals.
1 point = 1 manual.