TP Link CPE610V2 User Manual

Installation Guide
5GHz 300Mbps 23dBi Outdoor CPE
CPE610
Contents
Overview
Package Contents
Hardware Overview
Hardware Connection
Application Example
Hardware Installation
Power Supply
Lightning & ESD Protection
Installer Compliance Responsibility
Software Configuration
Logging in to the PharOS
Configuration for a Typical Application
Antenna Alignment
Specifications
FAQ
4
17
20
21
22
Overview
TP-Link's Pharos series outdoor CPEs are dedicated to outdoor wireless network solutions. This guide is applicable to the product CPE610.
Package Contents
Pharos CPE
Rear Cover Mounting Bracket
Bolts with Nut and Lock
Washer Assemblies
(M6×110, Qty.2)
Power Cord Passive PoE Adapter
Mounting Bracket (For PoE Adapter)
Center Reflector Panel Side Reflector Panels
(For CPE)
Bolts with Nut and Lock
Washer Assemblies
(M6×70)
ST3×16 Self-tapping Screws
(Qty.2)
1
(Qty.2)
Protective Cap
Pole-mount Clamp
Installation Guide
Outdoor CPE
CPE610
Installation Guide
D3×28 Plastic Wall Anchors
(Qty.2)
Hardware Overview
Bottom View
Reflector Assembly
Securing Arms
Bubble Level
Rear Cover
Mounting Bracket
Pole-mount Clamp
2
Panel Layout
Passive PoE Adapter
On: The wireless function is enabled.
On: A device is connected to the ETHERNET port,
but there is no activity. Flashing: A device is connected to the
ETHERNET port and is active.
On: The CPE is powered on.
RESET
Press and hold for 5 seconds to reset the CPE to its factory defaults.
ETHERNET
The port is used to connect to the POE port of the provided PoE adapter for both data transmission and power supply through Ethernet cabling.
Remote Reset
Press and hold for 5 seconds to reset the CPE to its factory defaults.
Attention:The Adapter which works at 0-40 shall be installed and placed in an indoor environment.
3
Power LED
On: Power on. Off: Power off.
Hardware Connection
Site Consideration
Mounting Height
Ensure a clear line of sight between the wireless devices for optimum performance. An elevated location is recommended as obstacles like trees, buildings and large steel structures will weaken the wireless signal. See 'Q2' in 'FAQ' for details about how to calculate the minimum mounting height of the devices.
Line of Sight
Side View
4
Orientation
Install the CPE devices so that they point towards the devices that will receive the signal. You can orient the devices with the help of Google Maps, GPS and some landmarks. The horizontal bandwidth of CPE610 is 7°.
shenzhen
A
Line of Sight
Horizontal
Beamwidth
B
5
Application Example
The CPE device with the reflector installed provides outdoor network access over long distances for point-to-point applications.
The CPE device without the reflector installed provides outdoor
-to-indoor Wi-Fi coverage with the Feed only mode.
6
Hardware Installation
TERMS OF USE: Installers must abide by local rules and regulations in terms of legal frequency channels, output power, and Dynamic Frequency Selection (DFS) requirements.
1. Attach the Side Reflector Panels to the Center Reflector Panel as follows:
a. Insert the two mounting studs on the Center Reflector
Panel into the large opening of the slots on the Side Reflector Panel.
b. Slide the Side Reflector Panel until the mounting studs are
positioned over the narrow opening of the slots, and the top edges of the panels should be aligned when done.
7
c. Repeat step a and step b to attach the other Side Reflector
Panel.
d. (Optional) Attach the Side Reflector Panels to the Center
Reflector Panel more securely using four M2.5x8 bolts and nuts (not provided). This is recommended if the CPE device is exposed to extreme weather, such as strong winds.
2. Attach the Rear Cover to the reflector assembly as follows:
a. While holding the reflector assembly, align the raised edges
on the back with the Securing Arms of the Rear Cover, and align the Snap Hooks on the Rear Cover with the slots on the Center Reflector Panel.
8
b. Attach the Rear Cover to the reflector assembly. Press upon
the Rear Cover at the four positions marked in the diagram below in sequence until it locks into place.
1
2
3
4
WARNING: To avoid damage, do not place the panels on a flat
surface or push down on it.
9
3. Insert the Pharos CPE into the Rear Cover until the CPE locks into place.
4. Connect the Ethernet cable to the Pharos CPE.
a. Connect the Ethernet cable to the Ethernet port.
Note: The length of the Ethernet cable is up to 60m for steady power supply.
10
b. Attach the Protective Cap to the Rear Cover.
5. Attach the Mounting Bracket to the Rear Cover until the grooves on the Mounting Bracket are positioned over the pins on the Rear Cover.
11
6. Secure the Mounting Bracket to the Rear Cover using M6x70 Bolts with Nut and Lock Washer Assemblies.
7. Attach the CPE assembly to the pole using two Pole-mount Clamps and two M6x110 Bolts with Nut and Lock Washer Assemblies.
a. Insert the two Bolts into the Mounting Bracket.
12
b. Secure the Pole-mount Clamps with Nuts and Washers. Note: Suitable pole diameters range from 15mm to 70mm.
8. Adjust the azimuth and elevation angle of the CPE device to achieve maximum signal strength.
13
Power Supply
Connecting the PoE Adapter
Connect the devices as shown in the figure below.
PoE LAN
Ethernet cable
length up to 60m
Mounting the PoE Adapter (Optional)
Note: To ensure the passive PoE adapter is attached most securely, it is
recommended to install the adapter with the Ethernet port facing upward.
1. Drill two holes on the wall
and insert the plastic wall anchors into the the holes. Secure the mounting bracket to the wall.
2. Attach the passive PoE adapter to the mounting bracket by sliding the adapter in the direction of the arrows until it locks into place.
14
Lightning & ESD Protection
Proper grounding is extremely important for outdoor devices.
By using shielded CAT5e (or above) cable with ground wire and the provided PoE adapter, you can effectively eliminate ESD attacks.
CPE
Grounded 3-wire Power Outlet
Shielded CAT5e (or above) Cable with Ground Wire
PoE Adapter with Earth Ground
Sheath Twisted Pair
Ground Wire Cable Shield Secondary Cable Shield
15
Installer Compliance Responsibility
Devices must be professionally installed and it is the professional installer's responsibility to make sure the device is operated within local rules and regulations.
Since TP-Link’s Pharos outdoor CPE610 can be paired with a variety of antennas, the Antenna and Transmit Power fields are provided to the professional installer to assist in meeting regulatory requirements.
Refer to Antenna and Transmit Power elds to make sure the devices are operated within local rules and regulations.
16
Software Conguration
This chapter introduces the login to the PharOS Web Interface and the software configurations.
Logging in to the PharOS
1.
Before accessing the PharOS Web Interface, you need to assign a static IP address 192.168.0.X (X ranges between 2 and 253, e.g. 192.168.0.10) to your computer.
2.
Open a web browser, type http://192.168.0.254 into the address field and press Enter (Windows) or return (Mac). It is recommended to use the latest version of Google Chrome, Firefox or Safari.
192.168.0.254
3.
Enter admin for both User Name and Password, then select the Language from the drop-down list. Read and agree to the terms of use, then click Login.
17
4.
Change the default User Name and Password for security purposes. You can then start to configure your CPE.
For subsequent logins, use the new username and password.
For more configurations, please visit https://www.tp-link.com/support to download the User Guide of PharOS products in the download center.
Conguration for a Typical Application
The typical topology is as follows: Multiple wireless bridges are built among the access point and the clients. Follow the instructions below to configure the Access Point and the Client.
For simplicity, we will take one wireless bridge as an example.
Access Point
Client
Client
Client
Congure the Access Point (AP)
1. Log in to PharOS and go to the Quick Setup page.
2. Operation Mode: Select Access Point and click Next.
3. LAN Settings: Click Next.
4. Wireless AP Settings:
a. Create a new SSID (Network name) for your wireless
network.
b. Select WPA-PSK/WPA2-PSK for the Security method and
create a PSK Password to protect your AP.
18
c. Enter the distance between the Access Point and the
Client into the Distance Setting field.
d. Select the MAXtream checkbox (Refer to Q3 in FAQ for
details about MAXtream), and click Next.
5. Finish: Verify your settings and click Finish to complete the configuration.
Congure the Client
1. Log in to PharOS and go to the Quick Setup page.
2. Operation Mode: Select Client and click Next.
3. LAN Settings: Change the IP Address to 192.168.0.X (X
ranges between 2 and 253), the same subnet as the access point, and click Next.
4. Wireless Client Settings: a. Click Survey and select the SSID of the Access Point in
the AP list, then click Connect.
b.
Select WPA-PSK/WPA2-PSK from the Security option, enter the same PSK password and distance value of the Access Point, then click Next.
5. Finish: Verify your settings and click Finish to complete the configuration.
For more configurations, please visit https://www.tp-link.com/support to download the User Guide of PharOS products in the download center.
19
Antenna Alignment
In order to get the best performance, you can precisely align the direction of the CPE with the assistance of Wireless Signal Quality on the STATUS page of the PharOS Web Interface.
Adjust the direction of the CPE until the SNR reaches a maximum.
WBS+Antenna
20
WBS+Antenna
Specications
HARDWARE FEATURES
Interface
Button RESET: Restore the device to its factory
Power Supply
ESD Protection
Lightning Protection
Operating Temperature
Operating Humidity
Certication
WIRELESS FEATURES
802.11 Standards 11a/n
Note:
1. Estimation is based on shielded CAT5e(or above) cable with an
integrated grounding wire.
10/100Mbps Ethernet port
defaults
24V passive PoE adapter included
1
15KV
Up to 6KV
-40 to 70 (-40 to 158
10% to 90%
CE, FCC, RoHS, IP65
1
)
21
FAQ
How to restore the CPE to its factory default settings?
Q1.
Method 1:
With the CPE powered on, press and hold the RESET button on the CPE for about 5 seconds.
RESET Button:
Press & hold for about 5 seconds
Method 2:
With the CPE powered on, press and hold the Remote Reset button on the passive PoE adapter for about 5
seconds.
Remote Reset Button:
Press & hold for about 5 seconds
22
How to calculate the minimum mounting height
Q2.
of the devices?
In order to maximize the received signal strength of the devices, you need to minimize the effect of the out-of-phase signals, which is caused by obstacles in the path between the transmitter and the receiver. Fresnel Zone is a usual method to calculate this path, as shown in the formula and the figure below.
H h+r*(1 40%)
(H is the height of the CPE)
×
dd
=
r
21
+
dd
21
d2
where,
c
f
r = Fresnel zone radius in meters
c = 3x108 m/s, speed of light
f = operating frequency of the devices in Hz
d1 & d2 = the distances between the point and the devices in meters
d1
r
h = the height of obstacle at this point
For example, assume d1 is 2km, d2 is 8km, and f is 2.4GHz, then r would be 14.142m. Considering a toleration of 40%, allowable radius would be 8.485m. Assume h is 10m, then the result of the minimum mounting height based on this point would be 18.485m. Similarly, calculate the results based on all the points where there are obstacles, and the maximum value would be the final result.
For more information, please refer to:
http://en.wikipedia.org/wiki/Fresnel_zone
23
What is Pharos MAXtream?
Q3.
Pharos MAXtream is a proprietary protocol developed on the basis of Time Division Multiple Access (TDMA) by TP-Link.
The MAXtream technology has the following advantages:
Eliminates hidden node collisions & improves channel efficiency.
Lower latency, higher throughput, larger network capacity & more stability.
Improves the QoS for video, voice and sound data stream.
By dividing the timing of transmission into different time slots, MAXtream allows the Pharos devices to transmit in rapid succession, one after another, each stream using its own time slot to transmit and receive frames, which greatly reduces the chance of collision.
Pharos MAXtream is a non-standard Wi-Fi protocol that is only compatible with TP-Link’s Pharos series products. Please note that you will not be able to connect other Wi-Fi devices to an AP with MAXtream enabled.
Q4.
How can I use Spectrum Analysis to find the appropriate channel for the devices?
Log in to PharOS, click Spectrum Analysis in the tools
1.
drop-down list, wireless connections Click Yes to continue to the Spectrum Analysis page.
a window will pop up to remind you that all
will be lost during spectrum analysis.
24
2.
Click Start, PharOS will begin to analyze the power of frequency then click
. Observe the curves for a period of time, and
Stop
. Note that the relatively low and continuous part of the average curve indicates less radio noise. Here, we use the figure below as an example.
3.
When choosing channel/frequency, you should avoid the spectrum with large radio noise. In this example, the recommended channel/ frequency is 112/5560MHz.
25
FCC STATEMENT
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.
FCC RF Radiation Exposure Statement
This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. “To comply with FCC RF exposure compliance requirements, this grant is applicable to only Mobile Configurations. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.”
We, TP-Link USA Corporation, has determined that the equipment shown as above has been shown to comply with the applicable technical standards, FCC part 15. There is no unauthorized change is made in the equipment and the equipment is properly maintained and operated.
Issue Date: 2018/ 06/ 14
CE Mark Warning
RF Exposure Information
This device meets the EU requirements (2014/53/EU Article 3.1a) on the limitation of exposure of the general public to electromagnetic fields by way of health protection.
This is a class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.
EU declaration of conformity
TP-Link hereby declares that the device is in compliance with the essential requirements and other relevant provisions of directives 2014/53/EU, 2009/125/EC and 2011/65/EU. The original EU declaration of conformity may be found at http://ww­w.tp-link.com/en/ce
OPERATING FREQUENCY(the maxi­mum transmitted power)
5470 MHz -5725 MHz (30dBm)
RF Exposure Information
This device meets the EU requirements (2014/53/EU Article 3.1a) on the limitation of exposure of the general public to electromagnetic fields by way of health protection. The device complies with RF specifications when the device used at 20 cm from your body.
Продукт сертифіковано згідно с правилами системи УкрСЕПРО на відповідність вимогам нормативних документів та вимогам, що передбачені чинними законодавчими актами України.
Safety Information
Keep the device away from water, fire, humidity or hot environments.
Do not attempt to disassemble, repair, or modify the device. Do not use damaged charger or USB cable to charge the device.
Do not use any other chargers than those recommended.
Do not use the device where wireless devices are not allowed.
Adapter shall be installed near the equipment and shall be easily accessible.
Use only power supplies which are provided by manufacturer and in the
original packing of this product. If you have any questions, please don't hesitate to contact us.
For EU/EFTA, this product can be used in the following countries:
AT / BE / BG / CH / CY / CZ / DE / DK / EE / EL / EF / FI / FR / HR / HU / IE / IS / IT / LI / LT / LU / LV / MT / NL / NO / PL / PT / RO / SE / SI / SK / UK
Explanation of the symbols on the product label
Symbol Explanation
DC voltage
RECYCLING This product bears the selective sorting symbol for Waste
electrical and electronic equipment (WEEE). This means that this product must be handled pursuant to European directive 2012/19/EU in order to be recycled or dismantled to minimize its impact on the environment.
User has the choice to give his product to a competent recycling organization or to the retailer when he buys a new electrical or electronic equipment.
For technical support, User Guide and other information, please visit https://www.tp-link.com/support, or simply scan the QR code.
The products of TP-Link partly contain software code developed by third parties, including software code subject to the GNU General Public License (“GPL”). As applicable, the terms of the GPL and any information on obtaining access to the respective GPL Code used in TP-Link products are available to you in GPL-Code-Centre under (https://www.tp-link.com/en/support/g­pl/). The respective programs are distributed WITHOUT ANY WARRANTY and are subject to the copyrights of one or more authors. For details, see the GPL Code and other terms of the GPL.
© 2018 TP-Link
7106508090 REV1.0.2
Loading...