TL714C
HIGH-SPEED DIFFERENTIAL COMPARATOR
SLCS015 – DECEMBER 1988 – REVISED JUNE 1989
D
Operates From a 5-V Supply
D
Self-Biasing Inputs
D
Hysteresis . . . 10 mV Typ
D
Response Time ...6 ns Typ
D
Maximum Operating Frequency
50 MHz Typ
description
The TL714C is a high-speed differential
comparator fabricated with bipolar Schottky
symbol
IN+
D OR P PACKAGE
(TOP VIEW)
NC
1
IN –
NC — No internal connection
IN+
NC
2
3
4
V
8
CC
NC
7
OUT
6
GND
5
process technology. The circuit has differential
inputs and a TTL-compatible logic output with
symmetrical switching characteristics.
IN –
The device operates from a single 5-V supply and is useful as a disk-memory read-chain data comparator.
The TL714C is characterized for operation from 0°C to 70°C.
schematic of inputs and outputs
EACH INPUT
V
CC
V
CC
OUTPUT
50 Ω
OUT
100 Ω
IN
GND
All resistor values shown are nominal.
9.6 kΩ
OUT
9.6 kΩ
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
Copyright 1989, Texas Instruments Incorporated
1

TL714C
HIGH-SPEED DIFFERENTIAL COMPARATOR
SLCS015 – DECEMBER 1988 – REVISED JUNE 1989
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
Differential input voltage, V
Input voltage range, V
Low-level output current, I
Continuous total power dissipation See Dissipation Rating Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
Storage temperature range – 65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature1,6 mm (1/16 inch) from case for 10 seconds 260°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
†
Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated in the recommended operating conditions section of this
specification is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values, except differential voltage, are with respect to the network ground.
2. Differential voltage values are at IN+ with respect to IN –.
PACKAGE
D
P
(see Note 1) 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CC
I
POWER RATING
(see Note 2) ± 5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ID
V
40 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OL
0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A
DISSIPATION RATING TABLE
TA ≤ 25°C
500 mW
500 mW
DERATING FACTOR
5.8 mW/°C
N/A
DERATE
ABOVE T
64°C
N/A
TA = 75°C
A
POWER RATING
464 mW
500 mW
CC
to GND. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
recommended operating conditions
MIN MAX UNIT
Supply voltage, V
Common-mode input voltage, V
High-level output current, I
Low-level output current, I
Operating free-air temperature, T
CC
OH
OL
IC
A
4.75 5.25 V
1.4
to
VCC – 1.4
– 1 mA
16 mA
0 70 °C
V
†
electrical characteristics over free-air operating temperature range, VCC = 5 V (unless otherwise
noted)
PARAMETER TEST CONDITIONS MIN TYP‡MAX UNIT
V
V
V
V
I
r
I
‡
§
Threshold voltage (VT+ – VT–) VIC = 1.4 V to 3.6 V –75
T
Hysteresis (VT+ – VT–) 2 10 30 mV
hys
High-level output voltage VID = 100 mV, IOH = – 1 mA 2.7 3.4 V
OH
Low-level output voltage VID = – 100 mV, IOL = 16 mA 0.4 0.5 V
OL
Short-circuit output current – 30 – 110 mA
OS
Differential input resistance 2.9 kΩ
i
Supply current VID = –100 mV, IO = 0 7 12 mA
CC
All typical values are at TA = 25°C.
The algebraic convention, where the more negative limit is designated as minimum, is used in this data sheet for input threshold voltage levels
only.
§
75 mV
2
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265

TL714C
HIGH-SPEED DIFFERENTIAL COMPARATOR
SLCS015 – DECEMBER 1988 – REVISED JUNE 1989
switching characteristics, V
PARAMETER TEST CONDITIONS MIN TYP†MAX UNIT
f
Maximum operating frequency
max
t
Propagation delay time, low-to-high-level output
PLH
t
Propagation delay time, high-to-low-level output
PHL
t
Rise time
r
t
Fall time
f
†
All typical values are at TA = 25°C.
PARAMETER MEASUREMENT INFORMATION
tr ≤ 4 ns
V
ID
V
O
Figure 1. Propagation Delay Time,
Low to High (t
50%
10%
90%
t
PLH
1.4 V
= 5 V, T
CC
PLH
100 mV
–100 mV
V
V
)
= 25°C
A
VID = ± 250 mV,
CL = 25 pF,
V
= ± 100 mV, C
See Figures 1 and 2
VID = ± 100 mV, CL = 25 pF,
See Figure 3
OH
OL
tr = tf = 4 ns,
Input duty cycle = 50%
= 25 pF,
tf ≤ 4 ns
V
V
90%
ID
O
t
PHL
50%
10%
1.4 V
Figure 2. Propagation Delay Time,
High to Low (t
PHL
)
50 MHz
6 12 ns
6 12 ns
4 8 ns
4 8 ns
100 mV
–100 mV
V
OH
V
OL
tr ≤ 4 ns
V
ID
V
O
10%
90%
0.5 V
t
2.4 V
r
90%
10%
2.4 V
0.5 V
tf ≤ 4 ns
100 mV
–100 mV
t
f
V
OH
V
OL
Figure 3. Rise and Fall Times (tr, tf)
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
3

IMPORTANT NOTICE
T exas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue
any product or service without notice, and advise customers to obtain the latest version of relevant information
to verify, before placing orders, that information being relied on is current and complete. All products are sold
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those
pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent
TI deems necessary to support this warranty . Specific testing of all parameters of each device is not necessarily
performed, except those mandated by government requirements.
CERT AIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL
APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER
CRITICAL APPLICA TIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERST OOD TO
BE FULLY AT THE CUSTOMER’S RISK.
In order to minimize risks associated with the customer’s applications, adequate design and operating
safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other
intellectual property right of TI covering or relating to any combination, machine, or process in which such
semiconductor products or services might be or are used. TI’s publication of information regarding any third
party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.
Copyright 1998, Texas Instruments Incorporated