CY54/74FCT646T
3
Maximum Ratings
[4, 5]
(Above which the useful life may be impaired. For user
guidelines, not tested.)
Storage Temperature .................................–65°C to +150°C
Ambient Temperature with
Power Applied.............................................–65°C to +135°C
Supply Voltage to Ground Potential............... –0.5V to +7.0V
DC Input Voltage............................................–0.5V to +7.0V
DC Output Voltage......................................... –0.5V to +7.0V
DC Output Current (Maximum Sink Current/Pin).......120 mA
Power Dissipation..........................................................0.5W
Static Discharge Voltage............................................>2001V
(per MIL-STD-883, Method 3015)
Operating Range
Range Range
Ambient
Temperature V
CC
Commercial All –40°C to +85°C 5V ± 5%
Military
[6]
All –55°C to +125°C 5V ± 10%
Electrical Characteristics Over the Operating Range
Parameter Description Test Conditions Min. Typ.
[7]
Max. Unit
V
OH
Output HIGH Voltage VCC=Min., IOH=–32 mA Com’l 2.0 V
VCC=Min., IOH=–15 mA Com’l 2.4 3.3 V
VCC=Min., IOH=–12 mA Mil 2.4 3.3 V
V
OL
Output LOW Voltage VCC=Min., IOL=64 mA Com’l 0.3 0.55 V
VCC=Min., IOL=48 mA Mil 0.3 0.55 V
V
IH
Input HIGH Voltage 2.0 V
V
IL
Input LOW Voltage 0.8 V
V
H
Hysteresis
[8]
All inputs 0.2 V
V
IK
Input Clamp Diode Voltage VCC=Min., IIN=–18 mA –0.7 –1.2 V
I
I
Input HIGH Current VCC=Max., VIN=V
CC
5 µA
I
IH
Input HIGH Current
[8]
VCC=Max., VIN=2.7V ±1 µA
I
IL
Input LOW Current
[8]
VCC=Max., VIN=0.5V ±1 µA
I
OS
Output Short Circuit Current
[9]
VCC=Max., V
OUT
=0.0V –60 –120 –225 mA
I
OFF
Power-Off Disable VCC=0V, V
OUT
=4.5V ±1 µA
Capacitance
[8]
Parameter Description Typ.
[7]
Max. Unit
C
IN
Input Capacitance 6 10 pF
C
OUT
Output Capacitance 8 12 pF
Notes:
4. Unless otherwise noted, these limits are over the operating free-air temperature range.
5. Unused inputs must always be connected to an appropriate logic voltage level, preferably either V
CC
or ground.
6. TA is the “instant on” case temperature.
7. Typical values are at VCC=5.0V, TA=+25˚C ambient.
8. This parameter is specified but not tested.
9. Not morethanone output should beshorted ata time. Duration ofshort should notexceed one second.The use of high-speed testapparatus and/or sample
and hold techniques are preferable in order to minimize internal chip heating and more accurately reflect operational values. Otherwise prolonged shorting
of ahigh output mayraise thechiptemperature wellabove normal andthereby cause invalidreadings inother parametric tests.Inany sequenceof parameter
tests, IOS tests should be performed last.