CY74FCT191T
2
Maximum Ratings
[3, 4]
(Above which the useful life may be impaired. For user guidelines, not tested.)
Storage Temperature .................................–65°C to +150°C
Ambient Temperature with
Power Applied.............................................–65°C to +135°C
Supply Voltage to Ground Potential............... –0.5V to +7.0V
DC Input Voltage ........................................... –0.5V to +7.0V
DC Output Voltage......................................... –0.5V to +7.0V
DC Output Current (Maximum Sink Current/Pin) ......120 mA
Power Dissipation..........................................................0.5W
Static Discharge Voltage............................................>2001V
(per MIL-STD-883, Method 3015)
Notes:
1. H = HIGH Voltage Level, L = LOW Voltage Level, X = Don‘t Care,
= LOW-to-HIGH clock transition. =Low Pulse.
2. TC is generated internally.
Mode Select
[1]
Inputs
PL CE U/D CP Mode
H
H
L
H
L
L
X
H
L
H
X
X
X
X
Count Up
Count Down
Preset (Asynchronous)
No Change (Hold)
RC Function Table
[1]
Inputs Outputs
CE CP T
[2]
RC
Operating Range
Range
Ambient
Temperature V
CC
Commercial –40°C to +85°C 5V ± 5%
Electrical Characteristics Over the Operating Range
Parameter Description Test Conditions Min. Typ.
[5]
Max. Unit
V
OH
Output HIGH Voltage VCC=Min., IOH=–32 mA 2.0 V
VCC=Min., IOH=–15 mA 2.4 3.3 V
V
OL
Output LOW Voltage VCC=Min., IOL=64 mA 0.3 0.55 V
V
IH
Input HIGH Voltage 2.0 V
V
IL
Input LOW Voltage 0.8 V
V
H
Hysteresis
[6]
All inputs 0.2 V
V
IK
Input Clamp Diode Voltage VCC=Min., IIN=–18 mA –0.7 –1.2 V
I
I
Input HIGH Current VCC=Max., VIN=V
CC
5 µA
I
IH
Input HIGH Current VCC=Max., VIN=2.7V ±1 µA
I
IL
Input LOW Current VCC=Max., VIN=0.5V ±1 µA
I
OS
Output Short Circuit Current
[7]
VCC=Max., V
OUT
=0.0V –60 –120 –225 mA
I
OFF
Power-Off Disable VCC=0V, V
OUT
=4.5V ±1 µA
Capacitance
[6]
Parameter Description Typ.
[5]
Max. Unit
C
IN
Input Capacitance 5 10 pF
C
OUT
Output Capacitance 9 12 pF
Notes:
3. Unless otherwise noted, these limits are over the operating free-air temperature range.
4. Unused inputs must always be connected to an appropriate logic voltage level, preferably either V
CC
or ground.
5. Typical values are at VCC=5.0V, TA=+25˚C ambient.
6. This parameter is specified but not tested.
7. Not more than one output should beshorted ata time. Duration ofshort should not exceed one second. The use of high-speedtest apparatus and/or sample
and hold techniques are preferable in order to minimize internal chipheating and more accurately reflect operational values. Otherwiseprolonged shorting of
a high output may raise the chip temperature well above normal and thereby cause invalid readings in other parametric tests. In any sequence of parameter
tests, IOS tests should be performed last.