Texas Instruments CDC203DWR, CDC203DW Datasheet

CDC203
3.3-V HEX INVERTER/CLOCK DRIVER
SCAS324A – OCTOBER 1989 – REVISED NOVEMBER 1995
1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
D
Replaces 74AC11203
D
D
Operates at 3.3-V V
CC
D
Flow-Through Architecture Optimizes PCB Layout
D
Center-Pin VCC and GND Pin Configurations Minimize High-Speed Switching Noise
D
EPIC
(Enhanced-Performance Implanted
CMOS) 1-µm Process
D
500-mA Typical Latch-Up Immunity at 125°C
D
Packaged in Plastic Small-Outline Package
description
The CDC203 contains six independent inverters. The device performs the Boolean function Y = A. It is designed specifically for applications requiring low skew between switching outputs.
The CDC203 is characterized for operation from 25°C to 70°C.
FUNCTION TABLE
INPUT
A
OUTPUT
Y
H L L H
logic symbol
logic diagram (positive logic)
1A
20
20
1A 1Y
1
19
2A 2Y
2
18
3A 3Y
3
13
4A 4Y
8
12
5A 5Y
9
11
6A
6Y
10
1
1Y
1
2A
19
2Y
2
3A
18
3Y
3
4A
13
4Y
8
5A
12
5Y
9
6A
11
6Y
This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12.
10
Copyright 1995, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
EPIC is a trademark of Texas Instruments Incorporated.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
1 2 3 4 5 6 7 8 9 10
20 19 18 17 16 15 14 13 12 11
1Y 2Y
3Y GND GND GND GND
4Y
5Y
6Y
1A 2A 3A NC V
CC
V
CC
NC 4A 5A 6A
DW PACKAGE
(TOP VIEW)
NC – No internal connection
CDC203
3.3-V HEX INVERTER/CLOCK DRIVER
SCAS324A – OCTOBER 1989 – REVISED NOVEMBER 1995
2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, VCC –0.5 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage range, VI (see Note 1) –0.5 V to VCC + 0.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output voltage range, VO (see Note 1) –0.5 V to VCC + 0.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input clamp current, IIK (VI < 0 or VI > VCC) ±20 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output clamp current, IOK (VO < 0 or VO > VCC) ±50 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous output current, I
O
(VO = 0 to VCC) ±50 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous current through VCC or GND ±150 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maximum power dissipation at TA = 55°C (in still air) (see Note 2) 1.6 W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
–65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
2. The maximum package power dissipation is calculated using a junction temperature of 150°C and a board trace length of 750 mils. For more information, refer to the
Package Thermal Considerations
application note in the 1994
ABT Advanced BiCMOS T echnology
Data Book
, literature number SCBD002B.
recommended operating conditions
MIN NOM MAX UNIT
V
CC
Supply voltage 3 3.3 3.6 V
p
VCC = 3 V 2.1
VIHHigh-level input voltage
VCC = 3.6 V 2.5
V
p
VCC = 3 V 0.9
VILLow-level input voltage
VCC = 3.6 V 1.1
V
V
I
Input voltage 0 V
CC
V
V
O
Output voltage 0 V
CC
V
p
VCC = 3 V –12
IOHHigh-level output current
VCC = 3.6 V –12
mA
p
VCC = 3 V 12
IOLLow-level output current
VCC = 3.6 V 12
mA
t/v Input transition rise or fall rate 0 10 ns/V f
clock
Input clock frequency 40 MHz
T
A
Operating free-air temperature 25 70 °C