Tektronix TDS200 Series Instructions User manual

Instructions
TDS 200-Series Extension Modules
070-9565-04
This document supports TDS 200-Series firmware version 1.06 and greater, TDS2HM firmware all versions, TDS2CM firmware version 1.04 and greater, and TDS2MM firmware version 1.00 and greater. Refer to Read Me First on page 1 for more information.
Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and
pending. Information in this publication supercedes that in all previously published material. Specifications and price change privileges reserved.
Printed in the U.S.A. Tektronix, Inc., P.O. Box 1000, Wilsonville, OR 97070–1000 TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
WARRANTY SUMMARY
(TDS2HM, TDS2CM, and TDS2MM Extension Modules)
T ektronix warrants that the products that it manufactures and sells will be free from defects in materials and workmanship for a period of three (3) years from the date of shipment from an authorized Tektronix distributor. If a product proves defective within the respective period, Tektronix will provide repair or replacement as described in the complete warranty statement.
To arrange for service or obtain a copy of the complete warranty statement, please contact your nearest Tektronix sales and service office.
EXCEPT AS PROVIDED IN THIS SUMMARY OR THE APPLICABLE WARRANTY STATEMENT, TEKTRONIX MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL TEKTRONIX BE LIABLE FOR INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES.
Table of Contents
General Safety Summary ii. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Preface iv. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Conventions iv. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Command Entry v. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contacting Tektronix vi. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Getting Started 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dependencies 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Features 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Removing and Installing Modules 3. . . . . . . . . . . . . . . . . . . . . . .
Checking Module Installation 6. . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting Module Installation 6. . . . . . . . . . . . . . . . . . . . .
TDS2HM Hard Copy Module 7. . . . . . . . . . . . . . . . . . . . . . . .
Hard Copy Setup 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Testing the Hard Copy Port 9. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Printing an Oscilloscope Screen 9. . . . . . . . . . . . . . . . . . . . . . . .
TDS2CM Communications Module 10. . . . . . . . . . . . . . . . . . . .
RS-232 Setup 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GPIB Setup 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TDS2MM Measurement Module 27. . . . . . . . . . . . . . . . . . . . . .
Changed Math Operations 28. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Signal Measurements 29. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the FFT 30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appendix A: Certifications and Compliances 42. . . . . . . . . . . .
Appendix B: Comparing GPIB and RS-232 43. . . . . . . . . . . . .
Appendix C: Manuals 45. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TDS 200-Series Extension Module Instructions
i
General Safety Summary
Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. To avoid potential hazards, use the product only as specified.
Only qualified personnel should perform service procedures.
While using this product, you may need to access other parts of the system. Read the General Safety Summary in other system manuals for warnings and cautions related to operating the system.
Injury Precautions
Avoid Electric Overload. To avoid electric shock or fire hazard, do not
apply a voltage to a terminal that is outside the range specified for that terminal.
Do Not Operate Without Covers. To avoid electric shock or fire hazard,
do not operate this product with covers or panels removed.
Do Not Operate in Wet/Damp Conditions. To avoid electric shock, do not
operate this product in wet or damp conditions.
Do Not Operate in an Explosive Atmosphere. To avoid injury or fire
hazard, do not operate this product in an explosive atmosphere.
ii
TDS 200-Series Extension Module Instructions
General Safety Summary
Product Damage Precautions
Do Not Operate With Suspected Failures. If you suspect there is damage
to this product, have it inspected by qualified service personnel.
Safety Terms and Symbols
Terms in This Manual. These terms may appear in this manual:
CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property.
Terms on the Product. These terms may appear on the product:
DANGER indicates an injury hazard immediately accessible as you read the marking.
WARNING indicates an injury hazard not immediately accessible as you read the marking.
CAUTION indicates a hazard to property including the product.
Symbols on the Product. These symbols may appear on the product:
DANGER
High Voltage
Protective Ground
(Earth) Terminal
ATTENTION
Refer to Manual
Double
Insulated
TDS 200-Series Extension Module Instructions
iii
Preface
These instructions describe how to install, set up, and test the TDS2CM, TDS2HM, and TDS2MM Extension modules. This manual presumes that you understand how to operate the TDS 200-Series oscilloscope.
Conventions
This manual uses the following conventions: Labeled oscilloscope panel buttons are shown in the manual in all
uppercase letters. For example: UTILITY, HARDCOPY.
On-screen menu items are shown in the manual with the first
letter of each menu word in upper case. For example: Options, Recall Factory .
A list of panel buttons, separated by the
order in which to push the listed buttons. For example, UTILITY UTILITY panel button, then push the side menu button to the right of the Options menu item, and then push the side menu button to the right of the RS-232 menu item.
Options RS-232 means that you first push the
symbol, represents the
iv
TDS 200-Series Extension Module Instructions
Command Entry
Follow these general rules when entering oscilloscope commands over the RS-232 or GPIB bus:
You can enter commands in upper or lower case. You can abbreviate many oscilloscope commands. These
abbreviations are shown in uppercase letters. For example, the command ACQuire:NUMAVg can be entered simply as ACQ:NUMAV or acq:numav .
You can precede any command with white space characters.
White space characters include any combination of the ASCII control characters 00 through 09 and 0B through 20 hexadecimal (0 through 9 and 11 through 32 decimal).
Preface
The oscilloscope ignores commands that consist of just a
combination of white space characters and line feeds.
TDS 200-Series Extension Module Instructions
v
Preface
Contacting Tektronix
Product Support
Service Support
For other information
For application-oriented questions about a Tektronix measurement product, call toll free in North America: 1-800-TEK-WIDE (1-800-835-9433 ext. 2400) 6:00 a.m. – 5:00 p.m. Pacific time
Or contact us by e-mail: tm_app_supp@tek.com
For product support outside of North America, contact your local Tektronix distributor or sales office.
Contact your local Tektronix distributor or sales office. Or visit our web site for a listing of worldwide service locations.
http://www.tek.com/measurement In North America:
1-800-TEK-WIDE (1-800-835-9433) An operator will direct your call.
To write us Tektronix, Inc.
P.O. Box 1000 Wilsonville, OR 97070-1000
vi
TDS 200-Series Extension Module Instructions
Getting Started
This chapter describes important module and oscilloscope dependen­cies, and how to install and check the TDS 200-Series extension modules.
Read Me First
NOTE. Read the following text before installing your module. To display oscilloscope and module firmware version numbers, press UTILITY
TDS2MM and TDS 200-Series
The TDS2MM Module only operates on TDS 200-Series oscillo­scopes with firmware version v1.06 and greater . Contact Tektronix for information on how to upgrade your TDS 200-Series oscilloscope firmware.
System Status Misc.
Seiko Printer Support
Seiko printer support (DPU411, DPU412) is only available with the following firmware configurations:
Module and firmware TDS 200 firmware
TDS2HM v1.00 and greater v1.09 and greater TDS2CM v1.04 and greater TDS2MM v1.00 and greater v1.06 and greater
1
You cannot select the DPU411 or DPU412 over a remote interface with TDS2CM v1.03 and earlier.
TDS 200-Series Extension Module Instructions
1
v1.09 and greater
1
Getting Started
Features
The following table lists the module features.
Module Centronics RS-232 GPIB
FFT, rise/fall
time, pos/neg
pulse width
TDS2HM TDS2CM TDS2MM
2
TDS 200-Series Extension Module Instructions
Removing and Installing Modules
The following sections describe how to safely remove and install a module on your oscilloscope.
Preventing Electrostatic Damage
CAUTION. Electr ostatic discharge (ESD) can damage components in the extension module and the oscilloscope. To prevent ESD, follow the steps below when installing, removing, or handling the extension modules:
1. Always turn off the oscilloscope before removing or installing
extension modules.
2. Handle extension modules as little as possible.
Getting Started
3. Transport and store extension modules in a static-protected bag
or container .
4. Do not slide the extension module over any surface
5. Wear a grounded antistatic wrist strap to discharge the static
voltage from your body while installing or removing an extension module from the oscilloscope.
6. Do not touch the oscilloscope extension module connector pins.
7. Do not use any devices capable of generating or holding a static
charge in the work area where you install or remove extension modules.
8. Avoid handling modules in areas that have a floor or work-sur-
face covering capable of generating a static charge.
9. Make sure that you install the extension module cover after you
remove an extension module.
TDS 200-Series Extension Module Instructions
3
Getting Started
Removing an Extension Module
CAUTION. Electr ostatic discharge (ESD) can damage components in the extension module and the oscilloscope. To prevent ESD, follow the steps on page 3 when installing, removing, or handling the extension modules.
After removing a module, install the dummy module cover to protect the contact pins.
1 2
3
4
TDS 200-Series Extension Module Instructions
Getting Started
Installing an Extension Module
Make sure that you align the module connector to the oscilloscope connector pins before seating the module.
1
3
2
4
5
TDS 200-Series Extension Module Instructions
5
Getting Started
Checking Module Installation
To check that the extension module is correctly installed, turn on the oscilloscope. The power–up screen should include the message ”Extension Module Passed”. If the oscilloscope does not recognize the extension module at power-up, do the steps in Troubleshooting Module Installation below.
Troubleshooting Module Installation
If the oscilloscope does not recognize the extension module at power-up, do the following steps:
1. Turn off the oscilloscope.
2. Follow the ESD precautions listed on page 3.
3. Disconnect all cables from the extension module.
4. Remove the extension module (refer to page 4).
5. Examine the oscilloscope option connector for bent, broken, or
missing pins. If any pins are bent, carefully straighten them out.
6. Reinstall the extension module onto the oscilloscope.
7. Turn on the oscilloscope. If the oscilloscope still does not show
the module installed, contact the nearest Tektronix service center .
6
TDS 200-Series Extension Module Instructions
TDS2HM Hard Copy Module
The TDS2HM Module lets you print the oscilloscope screen data on a printer. This chapter describes how to set up and test the TDS2HM Hard Copy Extension Module. This information also applies to the hard copy portion of the TDS2CM Communications Module and the TDS2MM Measurement Module.
Centronics connector
TDS 200-Series Extension Module Instructions
7
Loading...
+ 39 hidden pages