Dear customer, We congratulate you on your choice. We are
sure that this modern, functional and practical article, constructed from highest quality materials, will fully meet your requirements.
Please read all the sections of this INSTRUCTION MANUAL before using the extractor for the first time to be able to obtain its full performance and to avoid any breakdowns that could arise from its misuse, also allowing small problems to be overcome.
Keep this manual. It will always provide useful information on the extractor and will help other people to use it.
Safety Instructions
* Before using the extractor for the first time, you must observe the installation and connection instructions.
* Never pull the cable to unplug the extractor. Always pull the plug.
* Do not switch on the extractor if the electricity cable is worn or has cuts or if there are signs of deterioration around the control panel.
* If the extractor stops working or functions abnormally, unplug it from the mains and advise the technical service.
* Do not leave gas burning without a pan above it under the hood.
* Do not allow grease to accumulate in any part of the extractor, especially in the filter as this COULD PRODUCE A FIRE RISK
* Do not flambé food under the hood. * Before installing the extractor consult local
rules and regulations in force with respect to current standards on air and fumes.
* Before connecting the extractor to the mains, check that both the voltage and the frequency conform to that shown on the characteristics label of the extractor located inside it.
* Switching on and off must be by means of an omnipolar switch with minimum separation between contacts of 3 mm incorporated into the fixed installation.
* The electrical connection must be made by means of a flexible cable. It is not allowed to connect it by means of a rigid conduit.
* The expelled air must not reach a duct that is used to expel food processor fumes using energy other than electricity.
* The room must be provided with appropriate ventilation if the extractor is going to be used at the same time as other food processing equipment not using electrical power.
* We recommend the use of gloves and caution when cleaning the inside of the extractor.
* Your extractor is designed for domestic use and only for expelling and purifying gases arising from food preparation. Its use for any other purpose must be at your own responsibility and may be dangerous.
* You should contact the nearest Qualified Technical Assistance Service for any repairs always using original spare parts. Repairs and modifications carried out by others could damage the apparatus or cause it to malfunction, and risking your safety. The manufacturer cannot be held liable for inappropriate use of the apparatus.
Page 4
18
GB
Index
Description of apparatus Page 3 Instructions for use 3 Cleaning and maintenance 4 Technical Information 4 Installation 5 If something does not work 5
Description of the apparatus
A Motor controls that allow three
positions to be selected
B Light switch independent of the motors C Lighting by means of lamps D Filters located over cooking area, easily
withdrawn for cleaning
E Extractable group that allows a greater
gas capture area
F Possibility of incorporating activated
charcoal filter
G Anti return tabs to be located in the
outlet mouth, locating their ends in the holes provided.
Instructions for use
By pressing the button shown in the figure, you will be able to control the functions of the extractor
Speed Light I Low switch on/off
II High + Intensive
Two achieve better extraction, we recommend switching on the extractor a few minutes before starting to cook (3 - 5 minutes) so that the air flow is continuous and stable when extracting the fumes.
Likewise,keep the extractor switched on for a few minutes when cooking is complete to allow all fumes and odours to be expelled.
E
A
C
D
B
A
D
H
G
F I I F
Page 5
19
GB
Cleaning and maintenance
Before carrying out any cleaning or maintenance activities, ensure that the extractor is disconnected from the mains.
To carry out cleaning and maintenance, follow the safety instructions indicated on Page 3.
Filter cleaning
To withdraw the filters from their locations release the anchoring points. Clean the filter, either by putting it in the dishwasher (see notes) or leaving it standing in hot water to simplify the removal of grease or, if wished, by means of special sprays (protecting the non metallic parts). Once clean, leave it to dry.
Notes: cleaning in the dishwasher with aggressive detergents may blacken the surface of metallic parts, without this affecting its gas retaining properties.
N.B. The filter must be cleaned at least once a month depending on how often the extractor is used. It must be remembered that grease is deposited in the extractor when cooking, whether it is switched on or not.
Cleaning of the extractor body
The use of warm (40ºC approx.) soapy water is recommended. A cloth moistened in this water is used for cleaning the extractor, paying special attention to the grids. Afterwards, dry using a lint-free cloth.
Note: Never use metallic scouring pads or abrasive products that could damage the surface.
Do not use scrapers with metallic surfaces such as knives, scissors etc.
Activated charcoal filter
To install the charcoal filter, the motor anchorage is made to coincide with the anchor points of the activated charcoal filter and turn it clockwise. The carbon filter lasts from three to six months depending on the particular conditions of use. The activated carbon filter can neither be washed nor regenerated. Once it is exhausted, it must be changed. To replace exhausted filters with new ones, withdraw the old one in the reverse order to that of installation.
Chaging Bulbs
Remove the filter support to acces the bulbs. Take care to disconnect the mains beforehand and that the bulbs to be replaced are not hot. The maximum bulbs power is 40W.
Technical information
Dimensions Width = 600 mm
Depth = 300 mm Height = 185 mm
Electrical characteristics REFER TO CHARACTERISTICS LABEL
300
24
475
600
559
184
142
Mod. Typ.
POTENCIA NOM. LAMPARAS NENNLEISTUNG GLÜHLAMPEN LAMPS RATE PUISSANCE LAMPES POTENCIA NOM. DAS LAMPADAS
2x40 W
XXX – ZZ Z-000000
N.º de fábric. Fabrik.-Nr. Serial No.
Made in European Community - C.I.F.: A-39004932
AA-000000
ELECT.
000…000 V. ~
00 Hz
000 W.
Page 6
Installation
To fix the extractor to the kitchen unit the pattern on page 6 is used. The lower part of the extractor must be located at a minimum height of 60 cm above the hob for electric cookers and 65 cm for gas cookers. If the instructions of a gas cooker indicate a greater distance these must be observed. The extractor must be connected to a wall socket with an effective earth. When the extractor is working at the same time as other non-electrical cooking equipment, the outlet air pressure must not exceed 4 Pa (4 x 10
-5
bar). To achieve optimum performance the length of the outlet hose should not exceed 4 meters, or include more than two 90º angles (elbows) Although venting to the outside is recommended, activated carbon filters may be used, which allow the gas to be returned to the kitchen through the outlet pipe. If you wish to exchange the front for one matching the kitchen units, follow the following instructions:
- Withdraw the movable group.
- Remove the screws (T) that support
the front
- Install the new front fixing it with the same
screws that held the old one.
If something does not work
Before seeking technical assistance carr y out the following checks first
20
Defect Possible cause Solution The extractor does The cable is not connected Connect the mains cable not work No current is reaching the plug Revise/repair the
electricity circuit
The extractor does not Filter saturated with grease Clean or substitute filter blow enough or vibrates
Outlet obstructed Eliminate obstructions
Inadequate air conduit Contact the installer and follow
instructions of this manual
The lamps do not light Lamp broken Exchange the bulb
Lamp loose Tighten bulb
T
T
T
320
340
GB
Page 7
21
GB
Special U.K. Requirements
Height above gas hob: 75 mm minimum NEVER PLACE THE COOKER HOOD OVER AN EYE-LEVEL GRILL This appliance must be connectec by a competent person, using fixed wiring via a DOUBLE POLE SWITCHED FUSED SPUR OUTLET
Electical connection
We recommend that the appliance is connected by a qualified electrician, who is a member of the N.I.C.E.I.C. and who will comply with the I.E.E. and local regulations. Should the colour of the wires in the manis lead for the appliance not correspond with the coloured markings identifying the
terminal in your spur box proceed as follows:
• The wire which is coloured blur must be connected to the marked N (Neutral) or coloured Black.
• The wire which is coloured brown must be connected to the marked L (Live) or couloured Red.
• Where avialable (see installation), the wire which is coloured yellow/green must be connected to the market or coloured Yellow/Green.
If the cooker hood is installed for use above a gas appliance then the provision vor ventilation must be in accordance with the Gas Safety (Installation & Use) Regulations 1984 and the relevant Building Regulations. Detailed recommendations are contained in the following British Standard Codes of Practice BS6172, BS5440 and BS6891 Current Edition.
Page 8
22
GB
4 x Ø8
Ø132
Ø132
559
151
458
598
66
84
214 300
A
B
A
C
Outlet for two motors Outlet for single motor Front of extractor
B C
Drilling pattern for installation in the kitchen unit
Loading...