Taylor RC26 User Manual

Rockton, Illinois 61072
800-255-0626
Phone 815-624-8333 Fax 815-624-8000
www.taylor-company.com
e-mail: info@taylor-company.com
International Office Taylor Company S.r.l. Roma, Italy Tel: +39-06-420-12002 Fax: +39-06-420-12034 e-mail: romeoff@taylor-company.com
RC26
Item No.
_______________________________
RC26
Provides high capacity refrigeration for frozen beverage dispensing. Two (2) remote condensing systems are required for models 346 and 349. Maximum total length of refrigeration discharge and liquid line is 100 feet (30.5 m).
Features
Remote Condensing System
RC26
RC26Remote Condensing System
Electrical
One dedicated connection required. Manufactured to be permanently connected. See the Electrical chart for proper electrical specifications.
Refrigeration Connections
Sealed bulkhead fittings, 5/8” OD on suction (low pressure) side and 3/8” OD on discharge (high pressure) side. (Refrigeration lines are not provided.)
Air Cooled
Minimum Clearance: 6” (152 mm) on 3 sides, with Air Deflector installed on Condenser Side. Minimum air clearances must be met to assure adequate air flow for optimum performance.
Taylor Company,
A Division of Carrier Commercial Refrigeration, Inc. Rockton, Illinois 61072 815-624-8333 800-255-0626 Fax 815-624-8000
www.taylor-company.com
Printed in U.S.A.
Weights lbs. kgs.
Net 59 26.8 Crated 89 40.4
cu. ft. cu. m.
Volume 17.1 .48
Dimensions in. mm.
Width 24-27/32 631 Depth 24-1/4 616 Height 22-3/16 564 Floor Clearance 4-1/4 108
Mounted on Standard Legs
Bidding Specs
Electrical: Volt ___________________ Hz__________ ph _________
Neutral: Yes No Cooling: Air Water NA
Options:_________________________________________________ _________________________________________________________
Outdoor Use
Options
Specifications
064554-ADV
6/07
Continuing research results in steady improvements; therefore, these
specifications are subject to change without notice.
Electrical Maximum Minimum Poles (P) Fuse Size Circuit Ampacity Wires (W)
208-230/60/1 Air 15 4 2P 3W
This unit may be manufactured in other electrical characteristics. Refer to the local Taylor Distributor for availability. (For exact electrical information, always refer to the data label of the unit.)