Taylor PST-540 User Manual

POLYSI TECHNOLOGIES, INC. Issued 4/7/95 5108 Rex McLeod Dr. Revision: 7 1/4/10 Sanford, N.C. 27330 Phone: (919) 775-4989
Material Safety Data Sheet Page 1 of 2
I. Product Product Name: PST-540 Product Type: Silicone Compound II. OSHA Components
None Present. This is not a hazardous material as defined in the OSHA Hazard Communication Standard. III. Effects of Overexposure
Eyes: Contact with eyes may cause redness. Flush eyes with copious amounts of water for 15. minutes. If irritation persists contact a physician.
Skin: Contact with skin causes no know irritation. Wash contacted areas with soap and water.
Ingestion: If ingested seek prompt medical attention. Do not induce vomiting. IV. Protective Equipment For Handling
Eyes: Safety Goggles or Glasses Skin: Gloves Ventilation: Not Required
V. Handling and Storage Handling: No special requirements Storage: Store in temperatures below 100 F
VI. Transport Information Class or Type: DOT and IATA: Non-Hazardous
VII. Spill and Disposal Procedures Cleaning up Spills: Use absorbent material to collect and contain material for disposal
Recommendation of Disposal Dispose in accordance with Federal, State and Local regulations
VIII. Reactivity Data Stability: Stable Hazardous Polymerization: Will Not Occur Incompatibilities: Strong Acids and oxidizing materials
POLYSI TECHNOLOGIES, INC. Revision: 7 1/4/10 5108 Rex McLeod Dr. Sanford, N.C. 27330 Phone 919-775-4989
Material Safety Data Sheet Page 2-2
Product # PST-540
IX.Flammability Flash Point: > 200 C Estimated HMIS Code: 100B Health Hazard: 1 Flammability Hazard 0 Reactivity 0 Explosive Limits: Unknown Extinguishing Agents: Carbon Dioxide or dry chemical (small fires), foam or water spray Hazardous Products Formed: Carbon Dioxide, carbon monoxide, silicon dioxide by Fire
X. Chemical and Physical Properties Vapor Pressure <5 mm Hg @ 25 C Vapor Density >1 Soluble in Water Insoluble Specific Gravity 2.5 Boiling Point: > 300 C Volatile Organic Compound % < 1.45 % pH Neutral Appearance White paste
XI. Other Information These data are offered in good faith as typical values and not as product specifications. No warranty, either expressed or implied, is hereby made. The recommended industrial hygiene and safe handling procedures are believed to be generally applicable. However, each user should review these recommendations in the specific context of the intended use and determine whether they are appropriate.
Prepared By: POLYSI TECHNOLOGIES, INC. 5108 Rex McLeod Dr Sanford N.C. 27330 Email polysi@polysi.com