TaoTronics TT-AH025 User Manual

Page 1
尺寸:160*160mm
Model:
装订成册 材质:封面128克铜版纸 内页80克书纸
TT-AH025
Page 2
www.taotronics.com
ASIA PACIFIC
E-mail:support.jp@taotronics.com(JP) Tel:03-5542-0238(10〜18時/土日祝除く) JPImporter:株式会社SUNVALLEYJAPAN Address:〒104-0032東京都中央区八丁堀3丁目18-6PMO京橋東9F
EUROPE
E-mail: support.uk@taotronics.com(UK) support.de@taotronics.com(DE) support.fr@taotronics.com(FR) support.es@taotronics.com(ES) support.it@taotronics.com(IT) EU Importer: ZBT International Trading GmbH Address:Halstenbeker Weg 98C, 25462 Rellingen, Deutschland
NORTH AMERICA
E-mail : support@taotronics.com(US) support.ca@taotronics.com(CA) Tel : 1-888-456-8468 (Monday-Friday: 9:00 – 17:00 PST) US Distributor: SUNVALLEYTEK INTERNATIONAL INC. Address:46724 Lakeview Blvd, Fremont, CA 94538
MANUFACTURER
Manufacturer: Shenzhen NearbyExpress Technology Development Co.,Ltd. Address: 333 Bulong Road, Shenzhen, China, 518129
Extend your warranty to 18 months by
registering your product on our website
taotronics.com/warranty:
support@taotronics.com(US)
support.ca@taotronics.com(CA)
support.uk@taotronics.com(UK)
MODEL: TT-AH025
TT-AH025_V1.0 EN
ULTRASONIC COOL MIST HUMIDIFIER
User Manual
Page 3
CONTENTS
STATEMENT
SAFETY INSTRUCTIONS
BEFORE USING THE HUMIDIFIER
WHEN USING THE HUMIDIFIER
AFTER USING THE HUMIDIFIER
PACKAGE CONTENTS
SPECIFICATIONS
PRODUCT DIAGRAM
OPERATIONS AND FUNCTIONS
Add Water
Power On / Off
Light Control
Low Water Protection: Auto Shut-off the Humidier
CLEANING AND MAINTENANCE
Caution
Daily Maintenance
Weekly Maintenance
Scale Removal Instructions
Disinfecting Instructions
Clean the Dustproof Sponge
End-Of-Season Care and Storage
TROUBLESHOOTING GUIDE
WARRANTY
TAOTRONICS CUSTOMER CARE
01
01
02
03
04
05
05
06
07
07
08
08
08
09
09
09
09
10
11
12
12
13/15
16
16
Page 4
STATEMENT
Thank you for purchasing a TaoTronics product that has been tested to meet our stringent quality standards.
This product is covered with TaoTronics product and labor warranty for 12 months from the date of its
original purchase.
Please email us with your order ID and problem or issue via support@taotronics.com, we will respond within
24 hours.
Please read the User Manual thoroughly. Clean and maintain the product as instructed. If any abnormalities
occur, please refer to the Troubleshooting Guide rst.
This warranty is void if the defect is caused by accidental damage, misuse, abuse, neglect, improper repair
or alteration by unauthorized persons, or a failure to follow operating instructions provided with the product
including adding essential oils directly into the tank and base. This warranty does not apply to normal wear
and tear or commercial use.
In no event shall liability exceed the purchase price paid by the purchaser of the product. Under no
circumstances shall there be liability for any loss – direct, indirect or incidental – or consequential damage
arising out of, or in connection with the use of the product.
BEFORE USING THE HUMIDIFIER
1 2
1. Please check the cord for any signs of damage.Do not use the humidier if the cord
has been damaged.
2. DO NOT place this humidier in wet environments.
Please always keep the humidier out of reach of patients & children & pet.
SAFETY INSTRUCTIONS
The humidier was made with safe and environmental protection materials, it has been certied and
complied with the requirement of sale regions’ related regulations or laws.
IMPORTANT: Please read and save this SAFETY INSTRUCTIONS before using the device. Basic precautions
should always be followed to reduce the risk of re, electrical shock, and injury to persons or damage to
the product.
01
30 CM
1
1. Please always place the unit on a smooth, at, lint-free, non-metallic, waterproof and level
surface and keep it away from direct sunlight.
2. Always place the unit 2 feet (60 cm) above the oor, 12 inches (30 cm) away from the wall,
other appliances or wooden furniture.
30 CM
60 CM
2
02
Page 5
WHEN USING THE HUMIDIFIER
AFTER USING THE HUMIDIFIER
1
1. DO NOT plug the unit with wet hands.
2. DO NOT direct the mist nozzle against the wall.
1
1. DO NOT use your hand or any other object to cover the nozzle while the unit is on to avoid
damaging the product or causing injury.
2. DO NOT clean the unit while it is connected to a power source or while it is on.
Humidity
40% 60%
1
2
2
2
1
1. Always disconnect from a power source by pulling out the plug when not in use.
2. Humidier requires regular cleaning. Please refer to, and follow the Cleaning and
Maintenance instructions.
1
1. DO NOT clean the humidier right after turning it off if the humidier is warm to touch.
Allow the humidier to completely cool down before cleaning.
2. DO NOT attempt to repair or adjust any electrical or mechanical functions on this humidier.
Doing so will void your warranty.
2
2
1. DO NOT move or tilt the humidier while it is in operation.
2. The most comfortable environmental humidity is between 40%-60%. Please adjust the mist as
needed.
03
04
Page 6
PACKAGE CONTENTS
· 1 x TaoTronics Humidier (Model: TT-AH025)
· 1 x Cleaning Brush
· 1 x Dustproof Sponge
· 1 x Thank You Card
· 1 x User Manual
SPECIFICATIONS
Model
Operating Voltage
Rated Power
Water Tank Capacity
Mist Output
Working Time on a Full Tank
Recommended Room Size
Noise
Dimensions
Net Weight
TT-AH025
AC 100-120V 50 / 60Hz
Min: 15W
Max: 25W
6.0L / 1.59Gal
Min: 60ml/h
Max: 300ml/h
20-60h
20-40m² / 215-430ft²
≤35dB
251 x 167 x 412mm / 9.9 x 6.6 x 16.2in
1775g/62.6oz
1
7
8
1. Nozzle
2. Water Tank
3. Water Level Window
4. Tank Cap
5. Water Inlet
6. Handle
7. LED Indicator
8. Control Knob
9. Base
2
3
12
9
10
11
PRODUCT DIAGRAM
10. Light Button
11. Night Light
12. Floater
13. Air Outlet
14. Tank Light
15. Water Reservoir
16. Atomizer
17. Dustproof Sponge
18. Air Inlet
4
5
6
13
14
15
16
push
17
18
0605
Page 7
OPERATIONS AND FUNCTIONS
1 2
Add Water
1. Remove the nozzle and turn the water tank upside down.
2. Remove the tank cap and ll the tank with clean and cool water only.
3. Attach the tank cap and place the tank back onto the base. Make sure it ts together
securely so that water can go from the tank to the reservoir. Put the nozzle back on.
3 4
OFF
ON
Min
Max
OFF
ON
5
Max
Min
Power On / Off and Mist Adjustment
Plug the power cord into a wall socket. Now the humidier is ready for use.
1. Rotate the control knob clockwise to the ON position. The blue LED indicator will light up
indicating that the humidier has been turned on .
2. Keep rotating the control knob clockwise to increase the mist level.
3. Rotate the control knob counterclockwise to decrease the mist level.
4. Rotate the control knob counterclockwise to the OFF position to turn off the humidier.
The LED indicator will turn off. The fan will work for another 3 minutes to dry the mist tube.
Note:
The most comfortable environmental humidity is between 40%-60%.
Please adjust the mist output as needed.
1 2 3 4
1. If tap water is too hard, it is recommended to use ltered or distilled water to avoid white
dust. DO NOT use hot water.
2. DO NOT add any essential oils or medicinal tablets into the water tank.
3. DO NOT add water into the base or through nozzle.
4. DO NOT move the humidier while the water tank is full of water to avoid leakage or base
overlling.
07
Light Control
1. Press the Light Button to turn on / off the night light.
2. Press and hold the Light Button for 1.5 seconds to turn on / off the tank light.
Low Water Protection: Auto Shut-off the Humidier
When there is not enough water inside the water reservoir, the humidier will stop misting and the LED
indicator will become red. It is designed for safety concern to prevent the humidier from possibly
overheating and damaging the atomizer.
08
Page 8
CLEANING AND MAINTENANCE
Caution
1. DO NOT submerge the base in water.
2. Make sure water does not enter the base through the air outlet, air inlet,
or the control knob and light button.
3. DO NOT wash any part of this humidier in dish washer which will
damage the humidier and void the warranty.
Daily Maintenance
Turn off the humidier, unplug it from the power source. Drain water from the tank, reservoir
and base.
Scale Removal Instructions
15S
1 2
15-20
minutes
Weekly Maintenance
1. To properly clean your humidier, we recommend you to remove scale and disinfect the
humidier separately.
2. DO NOT mix vinegar and bleach solutions together. Do not use more than 1 tsp. of
bleach per gallon of water to avoid damaging your humidier.
3. Please make sure the rubber ring & rubber cap & spring on the tank cap is installed
properly after cleaning to avoid water leakage. Please refer to the diagram on page 13.
09
3
5
4
6
10
Page 9
1. Turn off and unplug the humidier. Remove the nozzle.
2. Remove the water tank from the base. Remove the tank cap. Make sure that the white
sealing ring does not come off. Drain water from the water tank and base. Remove any
accessories and set them aside.
3. Fill the water tank half full. Add 1 teaspoon of undiluted distilled white vinegar. Attach the
tank cap and shake the tank for 15 seconds.
4. Place the tank onto the base. The vinegar solution will enter the water reservoir to loosen
mineral buildup (scale) on the atomizer, water oater and the bottom of the water tank.
Set it still for 15-20 minutes.
5. Uncap the tank cap and drain the solution. Wipe the atomizer and oater with a soft cloth
to remove loosened mineral deposits.
6. Rinse both the water reservoir and water tank until the smell of vinegar (for scale removal)
or bleach solution (for disinfecting, see below) is gone.
Clean the Dustproof Sponge
push
Clean the dustproof sponge (at the back of base) with water or detergent once a month. Put
it back in place after cleaning.
push
Disinfecting Instructions
1. Follow steps 1-2 of the previous section on scale removal.
2. Fill the water tank half full. Add ½ tsp of bleach. Place the tank cap back on. Swish the
solution around in tank. Place the tank on the base. The bleach solution will enter and
disinfect the water reservoir as well as the other components. Set it still for 15-20 minutes.
3. Follow steps 4-6 of the previous section on scale removal to complete disinfecting the
humidier.
11
End-Of-Season Care and Storage
1. Follow the cleaning instructions when the humidier will not be used for at least one week,
or at the end of the season. Remove any accessories used with the humidier and allow the
humidier and accessories to dry completely before storing.
2. DO NOT store with water inside the base, water reservoir, or tank.
3. Pack the unit safely and store in a cool, dry location.
12
Page 10
TROUBLESHOOTING GUIDE
1. If the information listed in the troubleshooting guide can’t solve your problem, please
email us for help.
2. Failure to keep this unit clean from mineral deposits may affect operation of this unit.
3. Customer failure to follow these instructions may void the warranty.
2
1
3
1. Spring
2. Rubber ring
3. Water oater
The unit is on but no mist or little mist is produced.
Tank leakage.
Not enough water inside the tank.
Mist level is set too low.
The base might be overlled.
Mineral buildup on atomizer.
Tank may be damaged.
Tank cap is not tightened securely.
2
Rubber ring was not installed on tank cap.
Rell and reinstall the water tank.
Adjust to larger mist output.
Remove the tank, empty the base and place back the lled tank on the empty base.
Put your hand towards the nozzle and feel if there is air coming out. If yes, clean the water scale on the atomizer as instructed(p10).
Check for possible cracks in the tank. Ask for a replacement if it is damaged.
Tighten the tank cap.
Check the tank cap for rubber ring, contact us if any is missing.
Problem Possible Cause Solution
Failed to turn on the unit.
Waterless indicator is constantly on.
13
Unit not plugged in.
No power from power outlet.
No water in the water reservoir.
3
Water oater get stuck.
Ensure unit is properly plugged in.
Try another power outlet.
Ensure the spring is secured properly to the tank allowing water to pass through to the base.
Adjust the water oater to a horizontal position and make sure it can rise up with water .
1
3
Mist height is low, damping surrounding desk or oor.Condensation forms around humidier or on windows and walls.
1
Spring get stuck.
Mist level is set too high for the room size.
Air inlet is blocked.
Low indoor temperature leads to liquefaction.
Ensure the spring is secured properly to the tank allowing water to pass through to the base.
1. Check if the room is too humid,adjust to lower mist output.
2. Open door and windows, or change to a larger room.
Humidier should be placed on a hard at surface, 2 feet above the oor, 12 inches away from the wall. Point mist outlet away from wall or window.
Raise the room temperature to 25°C/77°F.
1
14
Page 11
Poor humidication.
White dust appears / Black coating in the base akes off.
Mist level is set too low for the room size.
Air inlet is blocked.
Low indoor temperature leads to liquefaction.
Tap water may contain too much minerals.
1-1. Adjust to maximum mist output. 1-2. Close door or windows to reduce air ventilation, or change to a smaller room.
Humidier should be placed on a hard at surface, 2 feet above the oor, 12 inches away from the wall.
Raise the room temperature to 25°C/77°F.
Replace with ltered or distilled water or use with a TaoTronics Demineralization Cartridge.
WARRANTY
This product is covered with TaoTronics product and labor warranty for 12 months from the
date of its original purchase. You will be given a warranty extension of 18 months if the
product is registered on our website (www.taotronics.com).
Any defective part will be, at the discretion of SUNVALLEYTEK INTERNATIONAL INC. , repaired
or replaced at no charge if the appliance has not been tampered with and has been used
according to these printed directions.
If any problems occur, please contact TaoTronics support (support@taotronics.com)
immediately to launch a warranty claim. Specify model number and your Amazon order
number. Our Consumer Service Representative will respond within 1 business day, advise you
how to correct the problem yourself, or instruct you on how to return the defective unit back
to us for repair or replacement.
Strange water noise.
Humidier is getting too hot.
15
Unit needs to be cleaned.Strange odor.
Water is going down to the water reservoir.
Unit works long hours.
Clean the humidier as instructed.
Leave the empty water tank open in a cool place for 12 hours without the water tank cap attached.
This is normal while it is working.
Power off and place in a well-ventilated place for 10 minutes.
We can only provide after sales service for products that are sold by TaoTronics or TaoTronics
authorized retailers and distributors.If you have purchased your unit from a different place,
please contact your seller for return and warranty issues.
CONTACT / TAOTRONICS CUSTOMER CARE
PLEASE CONTACT US BEFORE RETURNING THIS PRODUCT TO THE STORE.
EMAIL TAOTRONICS CUSTOMER CARE FOR PROBLEMS AND QUESTIONS.
WE WILL RESPOND WITHIN 1 BUSINESS DAY.
Sunvalleytek USA, Inc.
Address: 46724 Lakeview Blvd, Fremont, CA 94538
E-mail: support@taotronics.com(US)
support.ca@taotronics.com(CA)
support.uk@taotronics.com(UK)
Tel: 1-888-456-8468 (Monday-Friday: 9:00 – 17:00 PST)
Website: www.taotronics.com
16
Page 12
17
www.taotronics.com
Page 13
Loading...