TaoTronics TT-AH004 User Manual

TAOTRONICS ULTRASONIC COOL MIST HUMIDIFIER
User Guide
Hello
TT-AH004
EUROPE
E-mail: support.uk@taotronics.com(UK) support.de@taotronics.com(DE) support.fr@taotronics.com(FR) support.es@taotronics.com(ES) support.it@taotronics.com(IT) EU Importer: ZBT International Trading GmbH, Halstenbeker Weg 98C, 25462 Rellingen, Deutschland
NORTH AMERICA
E-mail: support@taotronics.com(US) support.ca@taotronics.com(CA) Tel: 1-888-456-8468 (Monday-Friday: 9:00 – 17:00 PST) Address: 46724 Lakeview Blvd, Fremont, CA 94538
ASIA PACIFIC
www.taotronics.com
MADE IN CHINA
FCC Compliance
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must withstand any interference received, including interference that may cause undesired operation.
E-mail: support.jp@taotronics.com(JP)
JPImporter: 株式会社ニアバイダイレクトジャパン
CONTENTS
English Deutsch Français Español Italiano
日本語
01/08
09/18
19/27
28/36
37/46
47/55
Thank you for choosing the TaoTronics Ultrasonic Cool Mist Humidier. Please read this manual carefully and keep it for future reference.
US UK CA
01/02
Features
• Environment-friendly ultrasonic humidier
• Contemporary home décor design
• Operating status LED display
• Adjustable mist output
• Preset humidity level
• 1-24 hours delay start and auto off timer
• User-friendly sleep mode
Package Contents
• 1 x TaoTronics Ultrasonic Cool Mist Humidier (Model: TT-AH004)
• 1 x User Guide
Specications(US /CA/UK)
Model
Operating Voltage
Power
Water Tank Volume
Max Mist Output
Working Time
TT-AH004
US/CA: AC 120V 60Hz 0.4A UK: AC 230V 50Hz
30W
5L
350±30mL
13 hours at max output
Product Diagram
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩
Nozzle Handle Water Tank Water Filter Tank Cap Cleaning Brush Air Outlet Base Control Panel Power Cord
Adding Water
• Place the humidier on a at surface, lift the water tank and place it
upside down .
• Unscrew the tank cap counterclockwise, ll the water tank with clean water (make sure it doesn't overow ).
• Screw the tank cap back on in a clockwise direction. Do not screw with
too much force to avoid damaging the tank inlet.
• Place the tank back on the base.
How to Use
Connect the power cord after water has been lled and operate the humidier through the control panel. Follow the instructions below:
1. Power: Touch the power button to turn the unit on/ off.
2. Mist Output: When the unit is powered on, touch the Mist Output
button to cycle through 4 mist output levels.
03/04
3. Humidity Level: Touch the Humidity Level button to set the humidity level from 40% - 95% by a 5% difference of each tap. When the room humidity level is higher than that of the preset level, the unit will automatically turn off. Otherwise, misting will continue until the room humidity level reaches the preset level.
4. Delay Start Timer: Tap on the Delay Start Timer button to set the start
delay from 1 hour to 24 hours.The timer LED ashes three times to start
the countdown and the unit will turn on according to the set time.When
the timer mode is activated, all buttons are disabled except the Power
and Auto Off Timer button.
5. Auto Off Timer: Set the Auto Off Timer to between 1 hour to 24 hours.
The timer LED ashes three times to start the countdown and the unit will
shut off automatically when the set time is up. When the timer mode is
activated, all buttons are disabled except the Power and Delay Start
Timer button.
6. Sleep Mode: Tap on the Sleep button to activate sleep mode. Only the Sleep Mode icon will be shown on the display screen and the unit enters energy-saving mode with its lowest mist output.The button buzzer will shut off and the Control Panel will turn off in one minute. In sleep
mode, all buttons are disabled except the Power button.
Important
- Do not overll when adding water.
- Stop using when the water level is low.
- Do not power on the humidier when the water tank is not in place.
- Never add water hotter than 40°C/104°F to avoid any possible damage
or malfunction of the device.
- Do not pour the water through the mist outlet. Wipe off any water outside
the body with a dry cloth.
- When the room temperature is 0°C/30°F or below, please empty the
water from the unit. Ice can damage the components.
05/06
- Do not place metals, chemicals, or detergents into the water to avoid any possible damage or malfunction of the device.
- When the water tank is full, do not move it as the water might overow or ow into the circuit and damage the device.
- After usage, turn the unit off and unplug it from the power outlet.
- Never pour out the water remaining in the water tank without the power rst turned off and unplugged from the socket.
Cleaning the Water Tank
• Before cleaning, make sure that the unit is turned off and unplugged
from the power socket.
• Clean the water tank regularly (recommended once every 2-3 weeks) -
unscrew the water tank plug, wipe off the limescale in it and rinse off with clean water.
• Cleaning of the base (recommended once a week) - if there is
limescale on the water base, wipe the base with a soft cloth dipped with a mild cleaning agent and rinse off with clean water.
• External cleaning - rinse a soft cloth in warm water and wipe off surface
stains.The spray nozzle can be ushed with tap water directly.
Storing the humidier - when the unit is not going to be used for a long time,
clean and dry the unit and store it in a dry place in the original package.
Caution
• Please do not repair the product by yourself, always ask a professional
electrician or authorized technician for repairs.
• If you notice an unusual odor, please turn off the unit immediately.
• Please do not remove the power plug with wet hands as it may cause
electrical shock.
• Do not place this unit on a slope or uneven surface to avoid water
leaking or component damage.
Warranty
TaoTronics products are covered by a 12 month limited warranty from the date of its original purchase. If any problems occur, please contact our support team.
We can only provide after sales service for products that are sold by TaoTronics or TaoTronics authorized retailers and distributors. If you have purchased your unit from a different place, please contact your seller for return and warranty issues.
Support
Email: support@taotronics.com
Tel: 1-888-456-8468 ext: 4 (Mon to Fri, 8 am to 5 pm, PST)
Website: www.taotronics.com
Solutions
Connect power plug
Tap on the Mist Output button to cycle through 4 mist output levels
Add water into water tank
Power off and place in a well ventilated place for 10 minutes
Set the preset humidity level above the current room humidity level
Get rid of some water
Clean the water tank as instructed
Clean air inlet
Cap on the cover properly
Move the unit to a well-ventilated area
Causes
No power
Misting not turned on
Low water
The diffuser is getting too hot
The preset humidity level is lower than the current room humidity level
Water exceeding max level
Stain built up inside water tank
Air inlet blocked by dust
Cover not properly covered
Temperature and humidity of environment is too high
Problem
No mist coming out
Abnormal mist
Water leakage
Clean water tank as instructed, use after air drying
Clean water tank as instructed, use clean water
Turn down the mist output or humidity level
User clean water
Unit is new
Dirty water
High mist output or high preset humidity level
Contaminated water
Bad/strange smell
Mist or drops of water around the device
07/08
• Do not put this unit near any heat source or under direct sunlight.
• Keep away from other electric appliances that are prone to
humidity damage.
• Regularly clean the unit if it won’t be used for a long period. Store in a
dry and shady place.
• When plugged in, do not leave the diffuser unattended when there are
children around.
Troubleshooting Guide
Vielen Dank, dass Sie sich für den TaoTronics Ultraschall Frischnebel Luftbefeuchter entschieden haben. Bitte lesen Sie diese Anleitung sorgfältig und bewahren Sie sie zum späteren Nachschlagen gut auf.
DE
09/10
Eigenschaften
• Umweltfreundlicher Ultraschall Luftbefeuchter
• Zeitgemäßes Heim-Decor Design
• Betriebsstatus LED-Anzeige
• Verstellbarer Nebelausstoß
• Einstellbare Feuchtigkeitsstufe
Lieferumfang
• 1 x TaoTronics Ultraschall Frischnebel Luftbefeuchter (Modell: TT-AH004)
• 1 x Bedienungsanleitung
Spezikation
Modell
Betriebsspannung
Leistung
Wassertankvolumen
Nebelausstoß
Betriebszeit
TT-AH004
AC 230V 50Hz
30W
5L
350±30mL
13 Stunden bei max. Ausstoß
Wasser auffüllen
• Stellen Sie den Luftbefeuchter auf eine gerade Oberäche, heben Sie
den Wassertank an und stellen Sie Ihn auf den Kopf.
• Lösen sie den Tankverschluss entgegen des Uhrzeigersinns und füllen Sie
den Tank mit sauberem Wasser (Überfüllen Sie den Tank nicht)
• Schrauben Sie den Tankverschluss im Uhrzeigersinn auf den Tank.
Wenden Sie beim schrauben nicht zu viel Kraft an, um den Tank nicht zu beschädigen.
• Setzen Sie den Tank zurück auf den Fuß
Bedienungshinweise
Nachdem Sie das Wasser eingefüllt haben, verbinden Sie den Netzstecker mit einem Stromanschluss. Zum bedienen des Gerätes über das Bedienfeld Folgen Sie den unteren Anweisungen:
1. Gerät einschalten: Drücken Sie den Einschaltknopf um das Gerät
ein- und auszuschalten
11/12
① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩
Düse Halter Wassertank Wasserlter Tankverschluss Reinigungsbürste Luftabzug Bodenabdeckung Bedienfeld Netzkabel
Produktdiagramm
2. Nebelausstoß: Drücken Sie den Knopf für den Nebelausstoß wenn
das Gerät eingeschaltet ist um durch die 4 verschiedenen Nebelstufen zu schalten.
3. Feuchtigkeitsstufenregler: Drücken Sie den Knopf für die Feuchtigkeitsstufen um die Feuchtigkeit von 40% - 95% in 5% Schritten pro Knopfdruck zu regeln. Das Gerät schaltet sich automatisch ab, wenn die Luftfeuchtigkeit die eingestellte Feuchtigkeitsstufe
überschreitet, ansonsten strömt Nebel aus, bis die eingestellte
Feuchtigkeitsstufe erreicht ist.
4. Startverzögerung: Drücken Sie auf den Schalter für die Aktivierung der automatischen Startverzögerung von einer bis hin zu 24 Stunden.
Die LED des Schalters blinkt 3 mal sobald der Countdown läuft und das Gerät schaltet sich zur eingestellten Zeit von selbst ein. Sobald die
Zeitschaltuhr aktiviert ist sind alle Funktionen außer der Einschaltknopf und die automatische Ausschaltfunktion außer Kraft gesetzt.
5. Auto Ausschaltfunktion: Setzen Sie die Auto Ausstellfunktion von 1 bis hin zu 24 Stunden. Die LED des Schalters blinkt 3 mal wenn die Zeitschaltuhr aktiviert ist und das Gerät schaltet sich zur eingestellten Zeit automatisch aus. Wenn die Zeitschaltuhr aktiviert ist sind alle
anderen Schalter außer der Startknopf und die Startverzögerung außer
Kraft gesetzt.
6. Schlafmodus: Drücken Sie auf den Schlafmodusschalter um den Schlafmodus zu aktivieren. Im Display erscheint lediglich und das Gerät
bendet sich im Energiesparmodus bei geringstem Nebelausstoß. Der Summton der Knöpfe ist deaktiviert und auch das Bedienfeld schaltet
sich innerhalb von 1 Minute ab. Im Schlafmodus sind alle Schalter deaktiviert mit Ausnahme des Startknopfs.
13/14
Reinigung von Gehäuse / Wandler / Filter
- Bitte seien Sie vorsichtig beim Reinigen des Geräts. Spritzwasser im Inneren kann den Luftbefeuchter beschädigen.
- Schalten Sie den Luftbefeuchter aus.
- Lassen Sie das Wasser ab.
- Trocknen Sie den Luftbefeuchter mit einem Handtuch ab. Benutzen Sie
keine organischen Lösungsmittel wie Alkohol oder Aceton zum Reinigen
des Gehäuses.
- Zum Reinigen des Wandlers gießen Sie etwas Essig auf den Wandler.
- Füllen Sie eine kleine Menge warmes Wasser ein und warten
Sie 3 bis 5 Minuten.
- Reinigen Sie den Wandler mit der mitgelieferten Bürste.
- Spülen Sie den Wandler mit Wasser ab.
- Zum Reinigen des Filters, tauchen Sie ihn 10 Minuten lang in weißen Essig
und spülen Sie ihn danach mit Wasser ab.
Wichtig
- Überfüllen Sie den Tank nicht wenn Sie Wasser hinzugeben.
- Achten Sie beim Einfüllen von Wasser darauf, die maximale Füllhöhe
nicht zu überschreiten.
- Hören Sie auf das Gerät zu verwenden, wenn der Wasserstand niedrig ist.
- Schalten Sie den Luftbefeuchter nicht ein, wenn der Wassertank nicht eingesetzt ist.
- Füllen Sie kein Wasser ein, das wärmer als 40°C ist, um Schäden und Fehlfunktionen zu vermeiden.
- Füllen Sie kein Wasser durch die Düse ein. Wischen Sie Wasser auf der
Außenseite des Gehäuses mit einem trockenen Tuch ab.
- Wenn die Raumtemperatur bei 0°C oder darunter liegt, leeren Sie den Wassertank bitte vollständig, weil Eis die Komponenten beschädigen kann.
Loading...