Starrett 3752 Series User Manual

3752 Series Electronic Height Gage
User’s Guide
INTRODUCTION
This height gage is another example of the quality measuring tools produced by The L. S. Starrett Company. Simple operation, self-contained digital electronic readout and accuracy are combined to provide a new experience in height gage measurement.
FEATURES
Large Digital Display
Preset Capabilities
This feature enables a user to pre-assign a reading of any value into the display at any position of the slide.
Limits
The minimum and maximum limit of a tolerance can be set using this feature. This is useful so that a user can set pass/fail criteria when measuring repetitive dimensions and desires to auto­mate quality screening processes on the production or shop floor.
Floating Zero Capacity
The display can be set to zero at any position of the measuring slide. This feature is especially useful when measuring the difference between two or more features on an object, eliminating hand calculation of the two measurements. Also, it is useful to “zero” the gage on an alternate datum along a part under evaluation.
Plus and Minus Display
Only negative values will have a sign displayed before the digit indicating negative position with relation to zero. This feature also allows use of the gage as a comparator. Zero can be set at a known position and variations read directly as plus or minus deviation.
Inch/Millimeter Display
Measurements may be displayed in inches or in millimeters as selected by the switch. This option is a direct conversion and can be done at any position on the scale without changing the reference zero position or the displayed measurement.
Hold Feature
A displayed measurement may be retained on the display regardless of movement of the gage slide and without loss of the original zero position. This feature allows retention of the reading when the display is not positioned for easy reading.
Over Speed Indicator
The word “ERR04” is displayed when the gage slide is moved at excessive speed. This feature will cancel the display rather than show an incorrect reading.
Automatic Off
The gage will turn off (the display will go blank) after 30 minutes of no slide movement or pressing of a button. Any movement of the slide will activate the display with no loss of position reading.
Hardened Base
The No.3752 Series of height gages feature well-balanced, hardened, ground and lapped bases with convenient finger grooves as furnished on other Starrett quality height gages.
USE INSTRUCTIONS
Getting Started
Clean the bottom of the height gage and the surface plate or reference surface being used. Move the gage slide to activate the measuring mode on the height gage. The display should show the gage slide position and is now ready to measure movement of the slide.
To Establish a Zero Reference Using an Indicator
An indicator should be mounted on the proper attachment of the height gage to use as a position­ing device. A test indicator can be used if the part configuration will allow. The reference zero position can be the surface plate itself, a gage block or a reference surface on the product part. Loosen the lock on the gage slide and carrier, then move the slide to a position where the indicator contact is slightly above the zero reference surface but not touching it. Using the fine adjustment knob, move the slide until a zero reading shows on the indicator.
NOTE: If using a dial indicator, be sure to count revolutions of the indicator hand. If using a digital indicator depress the ZERO button to change the display to a zero position “0.0000”(0.00mm).
Measurement of a Height
Loosen the lock on the gage slide and carrier, then move the slide to a position slightly above the surface to be measured. Move the gage into position so that the indicator contact is directly over the surface to be measured and using the fine adjustment mechanism, move the slide until the indicator reads zero. The display will show the exact dimension of the surface or feature being measured with reference to the zero position.
Using a Scriber
The special scriber furnished with the height gage can be mounted using the scriber clamp to allow the scriber to contact the surface plate if required for zero reference. Operation of the height gage is the same as noted above in “Zero Reference Using an Indicator” and “Measurement of a Height”.
NOTE: Use of the scriber to contact work surfaces depends on the ability of the operator to “feel” the contact surface without exerting excess pressure on the surface with the scriber.
2.
Battery Installation
Detail No. 1, 2
1.
To remove batteries, place screwdriver under battery as shown and pry up
Insert batteries under two tabs at an angle as shown, then press down to lock under the third tab
Detail No. 4
OPERATING INSTRUCTIONS
1. Remove and retain the battery slide
1.
2.
2. Move the battery slide up and away from
3. Remove the old batteries (detail #3).
4. Place two fresh CR2450 batteries (No.
Positive side of battery
5. Replace the battery slide by matching up
Detail No. 3
6. Re-install the slide locking screw to keep
Automatic OFF
The gage will turn off (the display will go blank) after 30 minutes of no slide movement or pushing of a but­ton. A push of the ON/OFF button or movement of the slide will reactivate the display with no loss of position reading.
locking screws (detail #1).
the gage (detail #2).
PT61120) into the battery slide with the positive (+) sides facing down (detail #4).
the grooved slots and then pressing it in and down.
the battery slide fixed in place.
ON/ OFF Button
A push of this button will turn the display either on or off with no loss of position reading.
+/- Button
When the gage is activated upon battery installation, the display will read “+” (positive) when the slide is moving upward and will read “-” (minus) when moving down. A push of this button will reverse the signs.
HOLD Button
When this button is pushed, the measurement of the display is frozen regardless of movement of the gage slide and without loss of the zero reference position. A second push will cancel the hold condition and return the display to the new position of the slide.
In/mm Button
The gage can be changed from inch mode to millimeter mode, or the reverse, with one push of this button.
3.
ZERO/ABS Button
One short push (less than one second) of this button will zero the display at any point (some call this the “incremental mode”). A long push (more than one second) of the button will return the display to the original reading (some call this the “absolute mode”) and the letters “ABS” will appear on the display.
SHIFT/SET Button
This is the button that gives great versatility to this tool. One push of this button will change the function of the button to SET - it will change the function of the ZERO/ABS button to PRESET and it will change the function of the In/mm button to LIMITS.
LIMITS Button
To install Limits, first press the SHIFT/SET button to get into the SET mode and the word “SET” will appear. Next, press the LIMITS button to get into the LIMITS mode. “MIN LIMIT” will appear and the previous minimum limit will be displayed. Press the SET button to allow the new minimum limit to be installed. “LIMIT” is now flashing. Move the slide until the display shows the new minimum limit to be installed. Finally, press the SET button to install the new limit. “LIMIT” stops flashing.
Now, press the LIMITS button again to change the display to the previous maximum limit. “MAX LIMIT” will appear. Then press the SET button to allow the display to be changed. “LIMIT” is now flashing. Move the slide to the new maximum limit reading and press the SET button to install the reading. “LIMITS” stops flashing. Then press the LIMITS button again to use the limits mode and once more to exit limits mode.
NOTE: After installation, the limits will show “out of tolerance” by a flashing display.
To get out of the Limits mode, press the LIMITS button once. This will return you to the normal measuring mode.
Preset Button
This button allows the manual setting of any desired reading into the display at any position of the slide.
To install a preset value:
1. First, locate the slide at the desired position.
2. Push the SHIFT/SET button to get into the secondary button functions and the word “SET”
will appear.
3. Press PRESET to get into the PRESET mode. The display will show a flashing “PRESET” and the previous preset number. When new batteries are installed, the preset value will show zero.
4. Press the SET button to index to a flashing “+” or “-” sign.
5. Press the PRESET button to change “+” or “-” or reverse.
6. Press the SET button to index to the first digit position, which will start flashing.
7. Press the PRESET button to change the number. Each press advances the number from
0-9. Stop when the number is correct.
8. Press the SET button to index to the next position and press the preset button to install a number from 0-9.
9. Continue to install a number from 0-9 in every position.
4.
10. After all numbers are installed, press the SET button and the displayed word “PRESET” will again start to flash.
11. Finally, check to see that the numbers are correct and the slide is in the proper posi­tion. Then press the PRESET button to install the whole number and the words “SET and “PRESET” will go away.
Output
The height gage comes with an output port that allows data transmission to Starrett No. 772 Data Collection Systems, No. 761 Multiplexer or to other devices that support Starrett RS232 format. Cable No. PT62103 is needed to interface with the above Starrett devices. Output is initiated via the button on the output cable or by transmitting an ASCII character to the gage. The output format is 4800 BAUD, 8 data bits, no parity, 1 stop bit, ASCII data. Transmission is exactly 16 characters, followed by a carriage return and line feed.
Low Battery Indication
The display will show a dim reading when the batteries are getting weak. Replace with two new batteries, CR2450 (No. PT61120).
Care and Maintenance
1. Do not store this instrument in areas of extreme temperature - below 10°F(-12°C) or above
130°F(54°C).
2. For best results, operate the height gage in an area free from dust and sprays of cutting oils and other coolants.
3. This is a precision instrument and extreme care should be taken to avoid bumping or drop­ping the gage.
4. The height gage has been calibrated at 68°F(20°C) (see specifications). Avoid using the gage in direct sunlight or in a draft of hot or cold air. For best results, use in a constant temp perature situation and allow time for the gage to soak at temperature for at least one hour when transferring the tool from a temperature difference of more that 10°F(-12°C).
5. Clean the height gage vertical bar using a clean, lint-free cloth. Apply a very light coat of lubricant. Use one or two drops of instrument oil on a finger and wipe over the vertical bar. Move slide up and down and wipe off the excess oil.
SPECIFICATIONS
I
Measuring Range 12” model 0-12 0-300
24” model 0-24 0-600
Accuracy 12” model ± .0015 ± 0.04 mm 24” model ± .0015 (0-18”) ± 0.04 mm ± .002 (18”-24”) ± 0.05 mm
Resolution .0005” .01 mm
Power Source Batteries - Lithium Coin Cells 3V
(2) No. CR2450 (No. PT61120) or Equivalent 1-1/2 Years Battery Life with Average Use
NCH MILLIMETER
5.
Serial Data
4800 BAUD 8 Data Bits No Parity 1 Stop Bit 16 characters followed by a carriage return (0DH) and line feed (0AH) Message length ( 18 characters) 45 MSEC
CABLE
To Starrett Collection Devices - No. PT62103 cable Directly to PC - No. PT62103 cable and PT61768 Adapter
SERVICE INFORMATION
The height gage has been properly assembled and calibrated at the factory. There are no adjust­ments that can be made without affecting the accuracy of this instrument, which may incur costly repairs. If the gage has been disassembled, repair charges will be required. If a malfunction occurs, consult the following checklist to insure that the problems are not due to improper opera­tion of the gage.
Problem What to Check
Does not count Is the gage in “HOLD” mode - Check by depressing “HOLD” button
and moving slide.
Error Display Over Speed Indicator
The word “ERR04” is displayed when the gage slide is moved at excessive speed. This feature will cancel the display rather then show an incorrect reading. Loss of Accuracy 1. Is gage base and surface plate clean?
2. Is indicator or scriber securely fastened in place?
3. Is the indicator or scriber clean and free of debris?
4. Is accuracy being checked against a calibrated standard?
5. Is the gage being used in an extremely humid environment?
If the height gage is still inoperative, return it to the manufacturer for repair. Please include a letter of explanation and ship to:
Repair Department The L.S. Starrett Company 165 Crescent Street Athol, MA 01331-1915 Tel. (978) 249-3551
6.
GALGA ELECTRÓNICA DE ALTURAS
Serie No. 3752
GUÍA DEL USUARIO
INTRODUCCIÓN
Esta galga de alturas es otro ejemplo de las herramientas de medición de calidad producidas por The L. S. Starrett Company. Una operación simple, un lector electrónico digital autocontenido y una extrema precisión se combinan para proporcionar una nueva experiencia en la medición con galgas de alturas.
CARACTERÍSTICAS
Pantalla digital grande
Los valores de medición se muestran en caracteres grandes usando una pantalla de cristal líquido (LCD) que puede leerse fácilmente. Se muestran hasta seis dígitos con cuatro lugares decimales para el modo de lectura en pulgadas y dos lugares decimales para el modo de lectura en milímetros.
Capacidades prestablecidas
Esta característica permite a un usuario preasignar una lectura de cualquier valor en la pantalla en cualquier posición de la regleta deslizante.
Límites
Es posible fijar el límite mínimo y máximo de una tolerancia usando esta característica. Esto resulta útil para que un usuario pueda establecer criterios de pasa/falla al medir dimensiones repetitivas y desee automatizar los procesos de detección de la calidad en la planta de produc­ción o el taller.
Capacidad de cero flotante
La pantalla puede establecer el cero en cualquier posición de la regleta deslizante de medición. Esta característica es especialmente útil al medir la diferencia entre dos o más características en un objeto, eliminando el cálculo manual de las dos mediciones. Además, resulta útil “poner en cero” la galga en un dato alternativo a lo largo de una pieza sometida a evaluación.
Pantalla del signo positivo y negativo
Sólo los valores negativos tendrán un signo mostrado antes del dígito que indica una posición negativa con relación al cero. Esta característica también permite utilizar la galga como un com­parador. Se puede establecer el cero en una posición conocida, y leerse las variaciones directa­mente como una desviación positiva o negativa.
Pantalla de pulgadas/milímetros
Pueden mostrarse mediciones en pulgadas o milímetros, según se selecciona con el interruptor. Esta opción es una conversión directa y se puede hacer en cualquier posición de la escala sin cambiar la posición del cero de referencia ni la medición mostrada.
7.
Característica de retención (HOLD)
Una medición mostrada puede ser retenida en la pantalla, independientemente del movimiento de la regleta deslizante de la galga y sin pérdida de la posición original del cero. Esta característica permite la retención de la lectura cuando la pantalla no está posicionada para una fácil lectura.
Indicador de exceso de velocidad
La palabra “ERR04” se muestra cuando la regleta deslizante de la galga se mueve a una veloci­dad excesiva. Esta característica cancelará la pantalla en lugar de mostrar una lectura incorrecta.
Apagado automático
La galga se apagará (la pantalla se pondrá en blanco) después de transcurrir 30 minutos sin movimiento de la regleta deslizante ni pulsarse un botón. Cualquier movimiento de la regleta deslizante reactivará la pantalla sin pérdida de la lectura de posición.
Base endurecida
La serie No. 3752 de las galgas de alturas presentan bases bien equilibradas, endurecidas, pulidas y solapadas con convenientes ranuras dactilares, tal como se suministra en otras galgas de alturas de calidad de Starrett.
INSTRUCCIONES DE USO
Procedimientos iniciales
Limpie la cara inferior de la galga de alturas y la placa de superficie o la superficie de referencia que se está usando. Mueva la regleta deslizante de la galga para activar el modo de medición en la galga de alturas. La pantalla debiera mostrar la posición de la regleta deslizante de la galga y ahora está lista para medir el movimiento de la regleta.
Para establecer una referencia al cero usando un indicador
Se debe montar un indicador en la conexión correcta de la galga de alturas para usarlo como dispositivo de posicionamiento. Puede usarse un indicador de prueba si la configuración de la pieza así lo permite.
La posición del cero de referencia puede ser la placa de superficie misma, un bloque de la galga o una superficie de referencia en la pieza del producto. Afloje el bloqueo de la regleta deslizante y transportador de la galga, y luego mueva la regleta deslizante a una posición donde el contacto del indicador está ligeramente por encima de la superficie de la referencia cero, pero sin tocarla. Usando la perilla de ajuste fino, mueva la regleta deslizante hasta que aparezca una lectura de cero en el indicador.
NOTA: Si se está usando un indicador de dial, asegúrese de contar las revoluciones de la manecilla indicadora. Si se está usando un indicador digital pulse el botón ZERO (CERO) para cambiar la pantalla a una posición de cero de “0.0000” (0,00 mm).
Medición de una altura
Afloje el bloqueo de la regleta deslizante de la galga y transportador, y luego mueva la regleta deslizante a una posición ligeramente por encima a la superficie que se desea medir. Mueva la galga en posición para que el contacto del indicador esté directamente sobre la superfi­cie que se desea medir, y usando el mecanismo de ajuste fino, mueva la regleta deslizante hasta
8.
que el indicador muestre cero. La pantalla mostrará la dimensión exacta de la superficie o carac­terística que se está midiendo con referencia a la posición del cero.
Uso de un trazador
El trazador especial suministrado con la galga de alturas se puede montar usando la abrazadera del trazador para permitir que éste entre en contacto con la placa de superficie, en caso de que esto se requiera para la referencia al cero. La operación de la galga de alturas es la misma que la indicada más arriba en “Referencia al cero usando un indicador” y “Medición de una altura”.
NOTA: El uso de un trazador para entrar en contacto con las superficies de trabajo depende de la habilidad del operador de “sentir” la superficie de contacto sin ejercer una presión excesiva en la superficie con el trazador.
INSTRUCCIONES DE OPERACIÓN
Instalación de la batería
DETALLE No. 1, 2
1.
2.
1.
LADO POSITIVO DE LA BATERÍA
DETALLE No. 3
PARA RETIRAR LAS BATERÍAS, COLOQUE EL DESTORNILLADOR DEBAJO DE LA BATERÍA TAL COMO SE MUESTRA Y HAGA PALANCA HACIA ARRIBA PARA QUITARLA
INSERTE LAS BATERÍAS DEBAJO DE LAS DOS LENGÜETAS EN UN ÁNGULO, TAL COMO SE MUESTRA, Y LUEGO PRESIONE HACIA ABAJO PARA BLOQUEAR DEBAJO DE LA TERCERA LENGÜETA
DETALLE No. 4
1. Retire y retenga los tornillos de bloqueo de la cubierta deslizante de la batería (detalle No. 1).
2. Mueva la cubierta deslizante de la batería hacia arriba, alejándola de la galga (detalle No. 2).
3. Retire las baterías gastadas (detalle No. 3).
4. Coloque dos baterías CR2450 nuevas (No.
PT61120) en la cubierta deslizante de la batería, con los lados positivos (+) orientados hacia abajo (detalle No. 4).
5. Vuelva a colocar la cubierta deslizante de la batería alineando las ranuras con muesca y presionando la cubierta hacia adentro y hacia abajo.
6. Vuelva a instalar el tornillo de bloqueo de la cubierta deslizante para mantenerla fija en su posición.
Apagado automático
La galga se apagará (la pantalla se pondrá en blanco) después de transcurrir 30 minutos sin movimiento de la regleta deslizante ni pulsarse un botón. Una pulsación del botón de encendido/apagado o movimiento de la regleta deslizante reactivará la pantalla sin pérdida alguna de lectura de la posición.
Botón de encendido/apagado (ON/OFF)
Una pulsación de este botón encenderá o apagará la pantalla, sin pérdida de la lectura de posición.
Botón +/-
Cuando se activa la galga al instalarse la batería,
9.