Spencer UL Listed Natural Gas Boosters LowCapacity Series User Manual

5 (1)
Spencer UL Listed Natural Gas Boosters LowCapacity Series User Manual

UL Listed Natural

Gas Boosters

Low Capacity Series

TEC

HN I CAL

DATA

SH EET

Produc t Feat ures

Hermetically Sealed – UL Listed

Single stage centrifugal design

Volume to 12,000 ICFH

P to 9" WC

Explosion-proof motor – UL Listed

Performan ce Dat a

Catalog

Inlet

Motor

GAS @ .6 Sp.Gr

Volume

Pressure

Number

Outlet

Hp

ICFH

IN WC

 

 

 

GL-0231-1/2-R

3 Thd

1/2

9000

6.4

GL-0244-1/2-R

4 Thd

1/2

12000

6.75

GL-0325-1/2-R

3 Thd

1/2

5400

9

The Spencer Turbine Company introduced the first hermetically sealed multistage natural gas boosters in 1975. The company continues to lead the industry with a range of designs using Spencer's standard overhung blowers and multiple, spark-resistant aluminum alloy impellers mounted directly on heavy-duty extended motor shafts.

Spencer’s Low Capacity Series UL Listed Natural Gas Booster is a single-stage design. Installations can boost pressure levels by 9 inches WC, with volumes to 12,000 ICFH. Spencer’s simple direct drive and generous internal clearances provide for long-term reliability and quiet operation — well within OSHA limits. The unique leaktight hermetic design also provides a continuous flow of natural gas around the explosion-proof motor, cooling the motor and extending its life.

In addition, Spencer offers the GasCube™ series, an easy-to-install natural gas booster skid package. It is pre-engineered, prepiped and has a compact footprint. The GasCube package is also available in organized modules for on-site assembly. Spencer’s complete line of hermetic, single and multistage, low and high-pressure gas boosters — including the GasCube skid package — undergo standard commercial tests at the factory for leaks as well as for power input, volume and pressure.

For information on Spencer’sHigh Capacity Series UL Listed Natural Gas Boosters, refer to Bulletin TDS-512 and for information on the GasCube Series, refer to Bulletin No. 515.

ºNotes: Ratings based on inlet gas at standard pressure of 14.7 PSIA, temperature 70°F, 0.6 specific gravity natural gas and 1.0 specific gravity air for UL Listing. Allowable maximum inlet to UL standards is 15.2 PSIA or 13” WC and nominal 70°F.

Gas Boosters include standard shaft,115/230V,1Ph or 208/230/460V, 3Ph, 60Hz, 3500 RPM, class 1, group D, UL Listed, explosion-proof motor with thermal overload protection and junction box.

The Spencer Turbine Company 600 Day Hill Road, Windsor, CT USA 06095 TEL 800-232-4321 860-688-8361 www.spencerturbine.com

Loading...