SONY KP-43T100, KP-53SV100 Service Manual

HISTORY INFORMATION FOR THE FOLLOWING MANUAL:
SERVICE MANUAL
MODEL NAME REMOTE COMMANDER DESTINATION CHASSIS NO.
KP-43T100
KP-53SV100
RM-Y906 E SCC-M16B-A
RA-3A
CHASSIS
ORIGINAL MANUAL ISSUE DATE: 10/2003
:UPDATED ITEM
REVISION DATE REVISION TYPE SUBJECT
10/2003 No revisions or updates are applicable at this time. 5/2004 Updated to include Argentina models. Section 6: Exploded View - Replaced pages 58-61. Section 7: Electrical Parts List - Replaced page 93.
COLOR REAR VIDEO PROJECTOR
9-965-951-02
Self Diagnosis
Supported model
SERVICE MANUAL
MODEL NAME REMOTE COMMANDER DESTINATION CHASSIS NO.
KP-43T100
KP-53SV100
RM-Y906 E SCC-M16A-A
RM-Y906 E SCC-M16B-A
RA-3A
CHASSIS
9-965-951-02
KP-53SV100 RM-Y906
COLOR REAR VIDEO PROJECTOR
KP-43T100/53SV100

TABLE OF CONTENTS

SECTION TITLE PAGE SECTION TITLE PAGE
Specifi cations........................................................................ 4
Warnings and Cautions......................................................... 5
Safety Check-out .................................................................. 6
Self-Diagnostic Function ....................................................... 7
1. Disassembly
1-1. Rear Board Removal .......................................................... 10
1-2. Chassis Assembly Removal ............................................... 10
1-3. Service Position .................................................................. 10
1-4. Beznet Assembly Removal................................................. 10
1-5. H1 Board Removal.............................................................. 11
1-6. H2 Board Removal.............................................................. 11
1-7. H3 Board Removal.............................................................. 11
1-8. H4 Board and S Board Remvoal......................................... 11
1-9. Mirror Cover Removal ......................................................... 12
1-10. A and G Board Removal ..................................................... 12
1-11. HV Cable Installation and Removal .................................... 13
1-12. Picture Tube Removal ......................................................... 13
2. Set-up Adjustments
2-1. Screen Voltage Adjustment................................................. 14
2-2. Screen (G2) Adjustment ..................................................... 14
2-3. Defl ection Yoke Tilt Adjustment........................................... 14
2-4. Focus Lens Adjustment ...................................................... 14
2-5. Focus Control Adjustment................................................... 15
2-6. 2-Pole Magnet Adjustment.................................................. 15
2-7. 4-Pole Magnet Adjustment.................................................. 16
2-8. Defocus Adjustment............................................................ 16
2-9. Electrical Adjustments By Remote Commander................. 16
2-10. Registration Adjustment (PJE mode only).......................... 22
2-11. Green Registration Adjustment........................................... 23
2-12. Red Registration Adjustment .............................................. 24
2-13. Blue Registration Adjustment.............................................. 24
2-14. Auto Registration Error Code List ....................................... 25
5. Diagrams
5-1. Circuit Boards Location....................................................... 30
5-2. PWB and Schematic Diagrams Information........................ 30
5-3. Block Diagrams................................................................... 32
5-4. Frame Schematic Diagram ................................................. 40
5-5. Schematics and Supporting Information............................. 41
A Board............................................................................... 41
CB Board ............................................................................ 46
CR Board ............................................................................ 48
CG Board............................................................................ 50
FA Board ............................................................................. 50
G Board .............................................................................. 51
H1 Board............................................................................. 54
H2 Board............................................................................. 54
H3 Board............................................................................. 55
H4 Board............................................................................. 55
S Board............................................................................... 55
5-6. Semiconductors .................................................................. 56
6. Exploded Views
6-1. Cover (KP-43T100)............................................................. 58
6-2. Cover (KP-53SV100) .......................................................... 59
6-3. Chassis (KP-43T100) ......................................................... 60
6-4. Chassis (KP-53SV100) ....................................................... 61
6-5. Picture Tube ....................................................................... 62
7. Electrical Parts List ......................................................................... 63
3. Safety Related Adjustments (G Board)
3-1. HV Regulation Circuit Check and Adjustment .................... 26
3-2. HV Hold Down Circuit Operation Check and Adjustment ... 26
3-3. +B Max Voltage Confi rmation ............................................. 27
3-4. +B OVP Confi rmation ......................................................... 27
4. Circuit Adjustments
4-1. TV Input Sub Contrast Adjustment ..................................... 28
4-2. Video Input Sub-Hue and Sub Color Adjustment ............... 28
4-3. Component Input Sub-Hue and Sub-Color Adjustment...... 28
4-4. PIP Sub-Contrast Adjustment............................................. 28
4-5. PIP Sub-Hue, Sub-Color Adjustment.................................. 29
4-6. User Control Bar Graph Display Position Adjustment......... 29
4-7. PIP Position Adjustment ..................................................... 29
— 3 —

SPECIFICATIONS

KP-43T100/53SV100
Power Requirements
110-220V AC, 50/60Hz
Power Consumption (W) In Use (Max) In Standby
Inputs/Outputs
160W 1 W
Video 1 IN
Video 2 INPUT (front)
Video 3 IN
S Video IN (4-pin mini DIN) Y: 1 Vp-p 75 ohms unbalanced, sync negative C: 0.286 Vp-p (Burst signal), 75 ohms,
Video (phono jack)
1.0 Vp-p, 75 ohms, sync negative;
Audio (phono jacks) 500 mVrms (100% modulation), Impedance: 47 kilohms
Speaker Woofer (2)
Tweeter (2)
Speaker Output (W)
Video 4 IN
Y: 1 Vp-p, 75 ohms, sync negative PB: 0.7 Vp-p, 75 ohms PR: 0.7 Vp-p, 75 ohms
Audio (phono jacks) 500 mVrms (100% modulation), Impedance: 47 kilohms
Audio (VAR/FIX) Out (phono jacks)
500 mVrms (100% modulation), Impedance: 470 ohms
Control S Out
minijack
KP-43T100 KP-53SV100
100 mm (4 in) 100 mm (4 in)
17W x 2 17W x 2
Dimensions (W x H x D) mm in
Television system
PAL-M, PAL-N, NTSC
Channel coverage
VHF: 2-13/ VHF: 14-69/ CATV: 1-125
Picture tube
7-inch high-brightness monochrome tubes (6.3 raster size), with optical coupling and liquid cooling system.
Screen size (measured diagonally)
43 inches (KP-43T100) 53 inches (KP-53SV100)
Mass kg
lbs
965 x 1058 x 570 mm 1,216 x 1,417 x 632 mm
38 x 41
x 22
1/2
in 47
7/8
x 55
3/4
x 24
5/8
Antenna
75 ohm external terminal for VHF/UHF
Supplied Accessories
Remote Control RM-Y906 Batteries (2) size AA (R6)
Optional Accessories
Connecting Cables RK-G34, RK-74A, RK-G69HG, VMC-10HG, VMC-720M,
VMC-810S/820S, YC-15V/30V
U/V mixer EAC-66
7/8
in
Design and specifi cations are subject to change without notice.
— 4 —
KP-43T100/53SV100
WARNINGS AND CAUTIONS
CAUTION
Short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield, or carbon painted on the CRT, after removing the anode.
WARNING!!
An isolation transformer should be used during any service to avoid possible shock hazard, because of live chassis. The chassis of this receiver is directly connected to the ac power line.
! SAFETY-RELATED COMPONENT WARNING!!
Components identifi ed by shading and ! mark on the schematic diagrams, exploded views, and in the parts list are critical for safe operation. Replace these components with Sony parts whose part numbers appear as shown in this manual or in supplements published by Sony. Circuit adjustments that are critical for safe operation are identifi ed in this manual. Follow these procedures whenever critical components are replaced or improper operation is suspected.
— 5 —

SAFETY CHECK-OUT

KP-43T100/53SV100
After correcting the original service problem, perform the following safety checks before releasing the set to the customer:
1. Check the area of your repair for unsoldered or poorly soldered connections. Check the entire board surface for solder splashes and bridges.
2. Check the interboard wiring to ensure that no wires are “pinched” or
touching high-wattage resistors.
3. Check that all control knobs, shields, covers, ground straps, and
mounting hardware have been replaced. Be absolutely certain that you have replaced all the insulators.
4. Look for unauthorized replacement parts, particularly transistors,
that were installed during a previous repair. Point them out to the customer and recommend their replacement.
5. Look for parts which, though functioning, show obvious signs of
deterioration. Point them out to the customer and recommend their replacement.
6. Check the line cords for cracks and abrasion. Recommend the
replacement of any such line cord to the customer.
7. Check the B+ and HV to see if they are specifi ed values. Make sure
your instruments are accurate; be suspicious of your HV meter if sets always have low HV.
8. Check the antenna terminals, metal trim, “metallized” knobs,
screws, and all other exposed metal parts for AC leakage. Check
leakage as described below.
Leakage Test
The AC leakage from any exposed metal part to earth ground and from all exposed metal parts to any exposed metal part having a return to chassis, must not exceed 0.5 mA (500 microamperes). Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA WT-540A. Follow the manufacturers’ instructions to use these instructions.
2. A battery-operated AC milliammeter. The Data Precision 245 digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a VOM or battery-operated AC voltmeter. The “limit” indication is
0.75 V, so analog meters must have an accurate low voltage scale. The Simpson’s 250 and Sanwa SH-63TRD are examples of passive VOMs that are suitable. Nearly all battery-operated digital multimeters that have a 2 VAC range are suitable (see Figure A).
How to Find a Good Earth Ground
A cold-water pipe is a guaranteed earth ground; the cover-plate retaining screw on most AC outlet boxes is also at earth ground. If the retaining screw is to be used as your earth ground, verify that it is at ground by measuring the resistance between it and a cold-water pipe with an ohmmeter. The reading should be zero ohms.
If a cold-water pipe is not accessible, connect a 60- to 100-watt trouble­light (not a neon lamp) between the hot side of the receptacle and the retaining screw. Try both slots, if necessary, to locate the hot side on the line; the lamp should light at normal brilliance if the screw is at ground potential (see Figure B).
To Exposed Metal Parts on Set
Trouble Light
Ohmmeter
0.15 µF
1.5 k
Earth Ground
AC Outlet Box
AC Voltmeter (0.75V)
Figure A. Using an AC voltmeter to check AC leakage. Figure B. Checking for earth ground.
— 6 —
Cold Water Pipe
KP-43T100/53SV100

SELF-DIAGNOSTIC FUNCTION

Self Diagnosis
Supported model
The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY/TIMER LED will automatically begin to fl ash. The number of times the LED fl ashes translates to a probable source of the problem. A defi nition of the STANDBY/TIMER LED fl ash indicators is listed in the instruction manual for the user’s knowledge and reference. If an error symptom cannot be reproduced, the Remote Commander can be used to review the failure occurrence data stored in memory to reveal past problems and how often these problems occur.
Diagnostic Test Indicators
When an error occurs, the STANDBY/TIMER LED will fl ash a set number of times to indicate the possible cause of the problem. If there is more than one error, the LED will identify the fi rst of the problem areas.
Results for all of the following diagnostic items are displayed on screen. If the screen displays a “0”, no error has occurred.
Diagnostic Item STANDBY/ Possible Problem Location Condition Detected Symptoms TIMER ashes
Power not On 0 [Standby Power Supply System] Cannot turn on the power F601 open LED doesn’t blink R607 open Q601 short circuit [Main Power Supply System} IC601 and R612 are broken VDR601 short-circuit
+B OCP Detection 2 times Short circuit of power supply in each circuit Goes to the standby mode 2: +B OCP 000 Short circuit of the +B line
+B OVP Detection 3 times T603 pin 7 to pin 8 is open Goes to the standby mode 3: +B OVP 000
Vertical Defl ection Stop 4 times IC 1509 (V OUT) is broken Raster goes to one line horizontally 4: V Stop 000 Q1505 (V Pulse Buffer) is broken A and then video signal is muted.
Video Out Abnormality 5 times Video Out, Q705, 732, 761, and others in C board STANDBY/TIMER LED blinks approx. 5: AKB 000 Detection 30 secs, then blinks for the diagnosis
Horizontal Defl ection Stop 6 times C515, 516 open. IC206 (YC Jungle) is broken. Raster does not appear. 6: H Stop 000
Audio Abnormality 8 times IC 406 (Audio amp.) is broken. The sound is not out. 8: Audio 000 Detection PS401, 402 open Goes to the standby mode
Note: 000 the range of values for number of operations is 000 - 255. For 256 or higher, the number remains as 255.
Display of Standby/Timer LED Flash Count
FLASH FOCUS
TV/VIDEO
FRONT PANEL
VOLUME
+ CHANNEL +
POWER
TIMER/STAND BY
EXAMPLE
Diagnosis Items Number of Blinks
+B overcurrent 2 times
+B overvoltage 3 times
TIMER/STANDBY indicator
* One blink is not used for self-diagnosis.
Vertical deflection stop 4 times
Lamp ON : 0.3 seconds
Lamp OFF : 0.3 seconds
Lamp OFF :
3.0 seconds
Release of TIMER/STANDBY indicator blinking.
The TIMER/STANDBY indicator blinking display is released by turning OFF the power switch on the TV main unit or removing the plug from the power.
— 7 —
KP-43T100/53SV100
Self-diagnosis screen displays
In cases of malfunctions where it is not possible to determine the symptom such as when the power goes off occasionally or when the screen disappears occasionally, there is a screen display on whether the malfunction occurred or not in the past (and whether the detection circuit operated or not) in order to allow confi rmation.
Screen Display Method
Quickly press the remote command button in the following order from the standby state.
Display
Channel
Sound Volume*
5
_
Power ON
*Note that this differs from entering the service mode (sound volume
SELF DIAGNOSIS 2: +B OCP 000
3: +B OVP 000
4: VSTOP 000
5: AKB 000
101: WDT 000
Self-Diagnosis Screen Display
The results display is not automatically cleared. In case of repairs and after repairs, check the self-diagnosis screen and be sure to return the results display to “ 0 ”.
If the results display is not returned to “ 0 ” it will not be possible to judge a new malfunction after completing repairs.
Method of Clearing Results Display
1. Power off (Set to the stanby mode.)
2.
Display
Channel
5
2: +B OCP 000
Sound Volume
Results
Diagnosis
+
000 the range of values for number of operations is 000-225. For 256 or higher, the number remains at 255.
Power ON (Service Mode)
)
+
3. Channel
Method of Ending Self Diagnosis Screen
When ending the self-diagnosis screen completely, turn the power switch OFF on the remote commander or the main unit.
8
(Test reset = Factory preset condition)
ENTER
— 8 —
KP-43T100/53SV100
Self-diagnosis function operation
OCP Low B and +B line detect DET SHORT, and shut-down POWER ON RELAY. Reset by turning power on/off. In case of +B is loaded approx. 1.3A or more, microcomputer detects it via IC651.
OVP In case of +B becomes approx. 150V or more, POWER ON RELAY shuts down and microcomputer detects it via IC651. Reset by turning power on/off just the same as OCP.
V Stop In case of microcomputer detects 2 seconds or more interval of V Pulse, Reference Pulse turns off by turning off the picture signal in YC Jungle IC (IC206). After the picture signal turns off, V Pulse is regenerated 2 seconds or more, the picture signal turns on.
AKB IK detection. Makes LED blinking in case of microcomputer doesn’t detect IK returns of IC206 CXA2147Q 30 seconds or more.
H Stop In case of HV becomes 33kV or more, IC502 detects it and shut-down H Drive Pulse. Microcomputer receives H Stop data from IC206 and makes LED blinking.
Audio In case of DC component overlaps the output of Audio Amp., microcomputer detects it and makes LED blinking. Microcomputer forces to shut down the power.
Self-diagnosis block diagram
8
55
IC002
mProcessor
20 21 22
IC004
EEPROM
Audio AMP
D1201
TIMER/STANDBY
5. AKB
6. H STOP
49 47 50 48
BUS
3 4
5. AKB
IC406
Q006
IC206
CXA2147
YCJ
27
IC1509 V Drive
43 35 34
6. HV STOP
IC502
HV Detector
Q1505
V Pulse Buffer
C Board
3. OVP
2. OCP
4. V.STOP (V Pulse)
Audio
IC651 OVP Buffer OCP Buffer
DC Detect
OVP DETECT
OCP DETECT
— 9 —

SECTION 1: DISASSEMBLY

(
)
KP-43T100/53SV100
1-1. REAR BOARD REMOVAL
Eleven Screws (Screw 4x20), tapping))
1

1-3. SERVICE POSITION

Rear board
2

1-2. CHASSIS ASSEMBLY REMOVAL

1
Three screws (Screw(4x20),tapping)
2
Chassis assy

1-4. BEZNET ASSEMBLY REMOVAL

1
Disconnect CN203
on A Board.
From CG Board CN1304.
A Board
CN203
G Board
(The extension cable is not supplied because of the countermeasure for radiation.)
Covers
2
Remove covers from Chassis Assembly with pliers when checking printed circuit boards. After checking, turn the covers over and re-secure them with the screws.
(Screws (4x20), tapping)
2
Beznet assy
3
1
(Screws (4x20), tapping)
Chassis Assembly
Screws
+BVTP3x12
— 10 —
KP-43T100/53SV100

1-5. H1 BOARD REMOVAL

2
Bracket H1
6
Button, power
7
Guide, LED

1-7. H3 BOARD REMOVAL

1
Two screws (+BVTP4x12)
H1 board
4
3
Screw
(+BVTP4x12)
Screw
5
(+BVTP4x12)

1-6. H2 BOARD REMOVAL

2
Screw, dome washer
HEX tap 4x20
Cap, speaker grille
1
Screw, dome washer
2
HEX tap 4x20

1-8. H4 AND S BOARD REMOVAL

5
Button, multi
Cap, speaker grille
1
Six screws
3
(+BVTP4x12)
4
H2 board
5
Door, side terminal
4
Bracket, H3
Two screws
3
(+BVTP3x12)
Screw
6
(+BVTP3x12)
H3 board
7
Holder, side terminal
2
Sensor bracket (B)
Sensor bracket (A)
7
S board
6
Claws
4
Two screws (+BVTP 4x12)
1
Four screws (+BVTP 4x12)
L screen holder
2
3
H4 board
Two screws
5
(+BVTP 4x12)
— 11 —

1-9. MIRROR COVER REMOVAL

1
Twenty-three screws (Screw (4x20), tapping)
KP-43T100/53SV100
G board
6
2
Mirror cover

1-10. A AND G BOARD REMOVAL

Screws
4
(+BVTP 3x12)
Six Screws
4
(+BVTP 3x12)
A board
6
2
Terminal board
1
Five screws (+BVTP 3x12)
Main bracket
Claws
5
— 12 —
Two screws
1
(+BVTP 3x12)

1-11. HIGH-VOLTAGE CABLE INSTALLATION AND REMOVAL

KP-43T100/53SV100
(1) Removal
1
Rubber cap
HV cable
2
turn 90
(2) Installation
Gutter
1
HV cable
Hook

1-12. PICTURE TUBE REMOVAL

CAUTION: Removing the arrow-marked screws is strictly prohibited. If removed, it may cause liquid to spill.
Lens
Picture tube
Four screws
2
(Screw (4x20), tapping)
3
4
Four screws (Screw (4x20), tapping)
Lens
5
Four screws
12
(+BVTP 4x12)
Picture tube
13
Deflection yoke
10
7
Neck Assy
6
CR board
1
Four screws (Screw (4x20), tapping)
— 13 —

SECTION 2: SET-UP ADJUSTMENTS

4
KP-43T100/53SV100

2-1. SCREEN VOLTAGE ADJUSTMENT (COARSE ADJUSTMENT)

1. Select a video input with no signal applied (the screen must be black, and the room must be as dark as possible. You may use a heavy blanket over the screen to block out ambient light).
2. Select picture mode “Personal 1” or “Personal 2”, and set BRIGHTNESS to 50% and PICTURE to minimum.
3. Turn the green SCREEN control on the focus block all the way to the left and then gradually turn it to the right until the retrace line is barely visible.
4. Gradually turn the control to the left until the retrace line just disappears.
5. Repeat steps 1 through 4 for the red and blue CRTs.
R G B
SCREEN
R G B
FOCUS
FOCUS block
2-2.SCREEN (G2) ADJUSTMENT (FINE ADJUSTMENT)
If the jig described below is available, it is recommended that the G2 Fine Mode Adjustment be performed to set the screen controls to their optimal condition. If desired, you can build the jig illustrated below, using 3-watt resistors. Please note that if the proper voltage is not obtained with the listed resistor’s values, then increase or decrease one of the values in the resistor network to obtain the correct voltage.

2-3. DEFLECTION YOKE TILT ADJUSTMENT

1. Display a cross-hatch pattern
2. Enter the service mode.
3. Cover the red and blue CRT lenses with lens caps to allow only green to show (or use the method shown in the note below for turning off the CRTs individually without using lens caps).
4. Loosen the green CRT’s defl ection yoke set screw and align the tilt of the defl ection yoke so that the horizontal bars at the center of the cross-hatch pattern are parallel to the top and bottom edges of the screen.
5. After aligning the defl ection yoke fasten it securely, making sure it is fully forward on the neck of the CRT.
6. The tilt of the defl ection yoke for red and blue are aligned the same way as the green CRT.
Cover the green and blue CRT lenses with lens caps (or use the
method shown in the note below for turning off the CRTs individually without using lens caps), then repeat steps 4 and 5 for the red CRT.
Cover the green and red CRT lenses with lens caps (or use the
method shown in the note below for turning off the CRTs individually without using lens caps), then repeat steps 4 and 5 for the blue CRT.
Note: If lens caps are unavailable, you can cut off the unnecessary color beams in the service mode by individually changing the data from “1” to “0” in category VPNT, item 28 RON (red), item 29 GON (green), or item 30 BON (blue).
2-pole magnet
-pole magnet
Deflection yoke
1. Select VIDEO-1 mode no signal applied (the screen must be black).
2. Connect the G2 JIG.
3. Switch on the JIG.
4. Connect an oscilloscope to the TP701(KR), TP732(KG) and TP761(KB) of CR board, CG board and CB board.
5. Adjust red, green, and blue screen voltage to 168-172V with SCREEN controls on the focus block, as shown below.
K
G2 JIG
3.3k 5.6k 5.6k 5.6k
200V GND
SW
GND
170V +/- 2V
pedestal level
Anode cap

2-4. FOCUS LENS ADJUSTMENT

In this adjustment, use the remote commander while in service mode. For details on the usage of the service mode and the remote commander, please refer the item 2-9. ELECTRICAL ADJUSTMENTS BY REMOTE COMMANDER.
1. Loosen the lens wing nut.
2. Enter the service mode.
3. Display a white raster.
4. Cover the red and blue CRT lenses with lens caps to allow only green to show (or use the method shown in the note below for turning off the CRTs individually without using lens caps).
5. Select adjustment category “PJE”, then press 6 to display the test signal (crosshatch)*.
— 14 —
KP-43T100/53SV100
* Every time 6 is pressed, the test signal changes to: “crosshatch+video signal” “dots+video signal” “crosshatch only” “dots only” black screen “crosshatch+video signal” ….etc.
6. Rotate the green lens assembly to adjust to the optimum focus point with the test signal being displayed
7. Tighten the lens wing nut.
8. Cover the green and blue CRT lenses with the lens caps to allow only red to show (or use the method shown in the note below for turning off the CRTs individually without using lens caps).
9. Make sure the cross-hatch is still being displayed; if not, follow step 5 above.
10. Adjust the red CRT lens the same way as the green CRT lens.
11. Cover the green and red CRT lenses with the lens caps to allow only blue to show (or use the method shown in the note below for turning off the CRTs individually without using lens caps).
Test Signal
7. Make sure the cross-hatch is still being displayed; if not, follow step 4 above.
8. Adjust the red focus control on the focus block to achieve the optimum focus point with the test signal being displayed.
9. Cover the green and red picture lenses with lens caps to allow only blue to show (or use the method shown in the note below for turning off the CRTs individually without using lens caps).
10. Make sure the cross-hatch is still being displayed; if not, follow step # 4 above.
11. Adjust the blue focus control on the focus block to achieve the optimum focus point with the test signal being displayed.
12. Repeat steps 1 through 11 after adjusting items 2-4. “Focus Lens Adjustment”, 2-6 “2-pole Magnet Adjustment”, 2-7 “ 4-Pole Magnet Adjustment”
Note: If lens caps are unavailable, you can cut off the unnecessary color beams in the service mode by individually changing the data from “`” to “0” in category VPNT, item 28 RON (red), item 29 GON (green), or item 30 BON (blue).
Scanning line visible.
12. Make sure the cross-hatch is still being displayed; if not, follow step # 5 above.
13. Adjust the blue CRT lens the same way as the green and red CRT lenses.
14. After adjusting the items 2-5 “Focus VR Adjustment”, 2-6 “2-Pole Magnet Adjustment” and 2-7 “4-Pole Magnet Adjustment”, reconfi rm the optimum focus point and adjust again if necessary.
Note: If lens caps are unavailable, you can cut off the unnecessary color beams in the service mode by individually changing the data from “1” to “0” in category VPNT, item 28 RON (red), item 29 GON (green), or item 30 BON (blue).

2-5. FOCUS CONTROL ADJUSTMENT

1. Enter the service mode.
2. Display a white raster.
3. Cover the red and blue CRT lenses with lens caps to allow only green to show (or use the method shown in the note below for turning off the CRTs individually without using lens caps).
4. Select adjustment category “PJE”, then press 6 to display the test signal (crosshatch)*.
* Every time 6 is pressed, the test signal changes to: “crosshatch+video signal” “dots+video signal” “crosshatch only” “dots only” black screen “crosshatch+video signal” ….etc.
A
Minimize both A and B.
Lens
B
Center of crosshatch

2-6. 2-POLE MAGNET ADJUSTMENT (GREEN, RED)

1. Display a dot pattern (see the details of using the internal test patterns at the end of the previous section).
2. Enter the service mode.
3. Cover the red and blue CRT lenses with lens caps to allow only green to show (or use the method shown in the note below for turning off the CRTs individually without using lens caps).
4. Turn the green focus control on the focus block to the right and set it to overfocus to enlarge the spot (the dot). See fi gure at the end of Section 2-3 for the location of the 2-pole magnet adjusting tabs.
5. Adjust the green CRT’s 2-pole magnet so that the small bright spot is in the center of the large defocused spot.
6. Adjust the green focus control on the focus block and set it for the best focus.
7. Repeat steps 1 through 6 for the red CRT, except now you will cover the green and blue CRT lenses with lens caps to allow only red to show (or use the method shown in the note below for turning off the CRTs individually without using lens caps) and you will adjust the red focus control on the focus block.
5. Adjust the green focus control on the focus block to achieve the optimum focus point with the test signal being displayed.
6. Cover the green and blue picture lenses with lens caps to allow only red to show (or use the method shown in the note below for turning off the CRTs individually without using lens caps).
— 15 —
Note: If lens caps are unavailable, you can cut off the unnecessary color
beams in the service mode by individually changing the data from “1” to “0” in category VPNT, item 28 RON (red), item 29 GON (green), or item 30 BON (blue).
(
)
x
Use the center dot
Large de-focused spot
KP-43T100/53SV100
3. Change TV mode to the video-1 input mode.
4. Select adjustment category “PJE”, and press 6 as many times as necessary to display the dot pattern on the screen.
5. Adjust the blue focus control on the focus block to adjust the diameter of the dots in the center of the screen as shown in the fi gure below.
Small focused spot

2-7. 4-POLE MAGNET ADJUSTMENT (GREEN, RED, BLUE)

1. Display a dot pattern (see the details of using the internal test patterns at the end of section 2-5, item 4).
2. Enter the service mode.
3. Cover the red and blue CRT lenses with lens caps to allow only green to show (or use the method shown in the note below for turning off the CRTs individually without using lens caps).
4. Turn the green focus control on the focus block to the left and set it to under-focus to enlarge the spot.
5. Adjust the 4-pole magnet so that the enlarged spot in the center of the screen becomes a perfect circle.
6. Adjust the green focus control on the focus block and set it for the best focus.
7. Repeat steps 1 through 6 for the red CRT, except now you will cover the green and blue CRT lenses with lens caps to allow only red to show (or use the method shown in the note below for turning off the CRTs individually without using lens caps) and you will adjust the red focus control on the focus block.
8. Repeat steps 1 through 6 for the blue CRT, except now cover the green and red CRT lenses with lens caps to allow only blue to show. Adjust the blue focus control on the focus block (or use the method shown in the note below for turning off the CRTs individually without using lens caps). However, for the blue CRT do not make the enlarged spot a perfect circle as indicated in step 5; instead, adjust the 4-pole magnet so that the height of the enlarged blue spot in the center of the screen is approx. 1.5 times the width of the spot.
Note: If lens caps are unavailable, you can cut off the unnecessary color beams in the service mode by individually changing the data from “1” to “0” in category VPNT, item 28 RON (red), item 29 GON (green), or item 30 BON (blue).
Use the center dot
x
y
x : y = 1:1.5 (BIue) x : y = 1:1 (Green, Red)

2-8. DEFOCUS ADJUSTMENT (BLUE)

Note: Adjust the blue dot to be slightly larger than red and green dots.
This adjustment provides a more pleasing picture to the customer.
1. Select the video menu and set the picture mode to “VIVID”.
2. Enter service mode.
FOCUS ADJUSTMENT POINT:
Dmm Ma
Screen Size
Diameter
43"
6mm
53"
8mm
2-9. ELECTRICAL ADJUSTMENTS BY REMOTE COMMANDER.
By using Remote Commander (RM-Y906), all circuit adjustments can be made.
Note : The following test equipment is required:
1. Pattern Generator (with RF, composite, and component outputs)
2. Digital multimeter

2-9-1. METHOD OF ENTERING THE SERVICE ADJUSTMENT MODE

SERVICE MODE PROCEDURE
1. TV must be in Standby mode. (Power off)
2. Press “DISPLAY”, 5, “Volume +”, then “TV Power” on the Remote Commander.
(Press each button within 1 second of pressing the previous button.)
SERVICE MODE ADJUSTMENT
3. The screen displays the adjustment category and the item being adjusted within that category.
4. Press 1 or 4 to select the adjustment item
5. Press 3 or 6 to change the data
6. Press 2 or 5 to select the adjustment category
7. If you want to go back to the most recently saved value, press “0” then “ENTER” to read the memory.
8. Press “MUTING” then “ENTER” to write the new adjustment data into memory.
9. Turn power off when you want to exit the service mode.
Category Adjustment item
DATA
SERVICE VPNT VPOS 031 000000 00
SCREEN DISPLAY
— 16 —
Note: Press “8” then “ENTER” to restore the factory settings for user
controls and channel memories (this will also turn set off and then on to exit the service mode).

2-9-2. MEMORY WRITE CONFIRMATION METHOD

1. After adjustment, remove the plug from the AC outlet, and then replace the plug in the AC outlet again.
2. Turn the power switch ON and enter the Service Mode.
3. Cycle through the adjusted items again and confi rm that the adjustments were saved.

2-9-3. ADJUSTING BUTTONS AND INDICATOR

Note: When the PJE mode (which displays an internally generated
signal) is activated, several buttons on the remote commander will have different functions than the ones listed above. Therefore, when in the PJE mode, refer to section 2-10 for button functions.
TV Power ON
MUTING
KP-43T100/53SV100
Category up
Adjustment item up
Adjustment item down
Display
Data up
Data down
Category down
ENTER
RM-Y906
— 17 —

2-9-4. SERVICE MODE LISTS

VPNT (Video Processor NTSC)
KP-43T100/53SV100
METI
REBMUN
0SOPV36-0 (24) NOITISOPV 1ZISV36-0 (30) EZISV 2 MOCV 3-0 0 PMOCV 3 NILV 51-0 (10) YTIRAENILV 4 OCSV 51-0 7 NOITCERROCEVRUCSV 5 SOPH 51-0 7 NOITISOPH 6ZISH36-0 (26) EZISH 7PMAP36-0 (20) PMANIP 8NIPU51-0 (7) NOITROTSIDNIPRENROCREPPU 9NIPL51-0NOITROTSIDNIPRENROCREWOL
01AHPP51-0ESAHPNIP 11 CFA 3-0 2 NIAGPOOLCFA 21 WOBV 51-0 7 WOBV 31 GNAV 51-0 7 ELGNAV 41 FER 3-0 3 NOITISOPESLUPECNEREFER 51VRDR36-0 (31) NIAGEVIRDDER 61VRDB36-0 (31) NIAGEVIRDEULB 71TUCR51-0 (7) FFOTUCDER 81TUCB51-0 (7) FFOTUCEULB 91NOCS51-0 (7) TSARTNOCBUS 02EUHS51-0 (9) EUHBUS 12LOCS51-0 (9) ROLOCBUS 22 2MDC 1,0 0 2EDOMNWODTNUOC 32 XIPD 1,0 1 ERUTCIPCIMANYD 42 CTON 1,0 0 PARTAMORHCY 52 MORC 51-0 7 0FPARTAMORHC 62 TOT 1,0 0 RETLIFTOTAMORHC 72FPHS3-02 0FSSENPRAHS 82NOR1,01 NODER 92NOG1,01 NONEERG 03NOB1,01 NOEULB 13LOCD1,01 ROLOCCIMANYD 23 DMDC 1,0 0 NWODTNUOCV 33 KLBL 51-0 31 HTDIWKNALBEDIS-TFEL 43 KLBR 51-0 31 HTDIWKNALBEDIS-THGIR 53 CERP 3-0 1 NIV.PMOCROFLEVELREVOERP 63 YERP 3-0 1 NIYROFLEVELREVOERP
TNEMTSUJDA
METI
ATAD
EGNAR
DRADNATS
ATAD
(7) (7)
SERVICE DATA NAME
ADJUSTM'T
SETTING
VARIABLE VARIABLE FIXED VARIABLE FIXED FIXED VARIABLE VARIABLE VARIABLE VARIABLE VARIABLE FIXED FIXED FIXED FIXED VARIABLE VARIABLE VARIABLE VARIABLE VARIABLE VARIABLE VARIABLE FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED
FIXED FIXED FIXED FIXED FIXED
( )= PREWRITE DATA
VPNV (Video Processor NTSC Vivid)
METI
REBMUN
0VRBS36-0 (35) DIVIVROFSSENTHGIRBBUS 1 VMMG 3-0 2 DIVIVROFLEVELAMMAG 2VCDY1,01 DIVIVROFOITARREFSNARTCD-Y 3 VLBA 1,0 1 DIVIVROFEDOMLBA 4VIXA1,00 DIVIVROFY-G,Y-RSIXA
TNEMTSUJDA
METI
ATAD
EGNAR
VPNS (Video Processor NTSC Standard)
REBMUN
0SRBS36-0DRADNATSROFSSENTHGIRBBUS 1 SMMG 3-0 0 DRADNATSROFLEVELAMMAG 2SCDY1,00 DRADNATSROFOITARREFSNARTCD-Y 3 SLBA 1,0 1 DRADNATSROFEDOMLBA 4SIXA1,00 DRADNATSROFY-G,Y-RSIXA
TNEMTSUJDA
METI
SMETI
ATAD
EGNAR
43T (29), 53V (30),
ATAD
ATAD
DRADNAT
DRADNATS
SERVICE DATA NAME
— 18 —
SERVICE DATA NAME
ADJUSTM'T
SETTING
VARIABLE FIXED FIXED FIXED FIXED
( ) = PREWRITE DATA
ADJUSTM'T
SETTING
VARIABLE FIXED FIXED FIXED FIXED
( ) = PREWRITE DATA
PJED (Projection TV Engine)
METI
REBMUN
TNEMTSUJDA
METI
ATAD
EGNAR
DRADNATS
ATAD
SERVICE DATA NAME
0 PSID 36-0 (9) NOITISOPHDSO 1lWF7-02 WODNIW1DLEIF 22WF7-03 WODNIW2DLEIF
METI
REBMUN
0 SIDF 1,0 0 JDAENIFFOYALPSIDATADIGERTCELES 1 HDSO 552-1 23 NOITISOPHUNEMECIVRESDEJP 2 VDSO 552-1 52 NOITISOPVUNEMECIVRESDEJP 3 TSVF 552-0 92 TRATSTSUJDAENIFFOREBMUNENIL 4 TS1V 552-0 0 ATADTRATS1V 5 UC1V 552-0 26 ATADPUTNUOC1V 6PHOC552-00 JDAHGUORFOESAHP-H 7PHIF552-0491JDAENIFFOESAHP-H 8PHPT552-016NRETTAPTSETFOESAHP-H 9PHFD552-0522SUCOFCIMANYDFOESAHP-H
01GHFD721-821-08-SUCOFCIMANYDFONIAG2-H 11 GVFD 721-821- 30- SUCOFCIMANYDFONIAG2-V 21 lMWP 552-0 0 lMWP 31 2MWP 552-0 03 NRETTAPTSETIGEROTUAFOESAHP-H 41 DLBH 552-0 832 ENILVEULBDENRUTERFOESAHP-H 51 WLBH 36-0 32 ENILVEULBDENRUTERFOHTDIWESLUP 61PKLB552-072ESLUPKNALBTRATS 71VGOC721-821-IGEROTUAFOATADTESFFOTNECVNEERG 81VROC721-821-IGEROTUAFOATADTESFFOTNECVDER 91VBOC721-821-0 IGEROTUAFOATADTESFFOTNECVEULB 02HGOC721-821­12 HROC 721-821­22 HBOC 721-821- 0 IGEROTUAFOATADTESFFOTNECHEULB 32 VGOS 721-821­42 VROS 721-821­52 VBOS 721-821- 0 IGEROTUAFOATADTESFFOWEKSVEULB 62HGOS721-821-0 72HROS721-821-0 IGEROTUAFOATADTESFFOWEKSHDER 82HBOS721-821-0 IGEROTUAFOATADTESFFOWEKSHEULB 92RREDEXIF0 EDOCRORREIGEROTUA 03MTDA552-0441IGEROTUAFOATADD/ATEGOTGNIMIT 13 PUV 552-1 1 NOITISOPVREPPUNRETTAPIGEROTUA 23 DIMV 552-1 401 NOITISOPVELDDIMNRETTAPIGEROTUA 33 WOLV 552-1 802 NOITISOPVREWOLNRETTAPIGEROTUA 43 RPH 015-1 1 NOITISOPHNRETTAPIGEROTUA
NRG
ULB
DER
TNEMTSUJDA
METI
TNEC115-215-0)00/00(0 TNECV/HNEERG
WEKS115-215-0)00/00(0 WEKSV/HNEERG
EZIS115-215-0)02-/05(- EZISV/HNEERG
NIL115-215-)xxx/xxx(NILV/HNEERG
YEK115-215-)xxx/xxx(YEKV/HNEERG
NIP115-215-0)32/xxx(NIPV/HNEERG
TNEC115-215-0)00/00(0 TNECV/HEULB
WEKS115-215-0)00-/00(0 WEKSV/HEULB
EZIS115-215- (-050/-225) EZISV/HEULB
NIL115-215- (-150/xxx) NILV/HEULB
YEK115-215- (xxx/-100) YEKV/HEULB
NIP115-215- (xxx/200) NIPV/HEULB
TNEC115-215- (000/000) TNECV/HDER
WEKS115-215- (000/000) WEKSV/HDER
EZIS115-215- (-050/-210) EZISV/HDER
NIL115-215- (150/xxx) NILV/HDER
YEK115-215- (xxx/100) YEKV/HDER
NIP115-215- (xxx/225) NIPV/HDER
ATAD
EGNAR
DRADNATS
ATAD
0 0
0 0
0 0
SERVICE DATA NAME
ID (Identifi cation)
METI
REBMUN
0 SERS 3-0 1 SERIES ID 1 LPWR 3-0 0 LAST POWER MEMORY 2 LANG 3-0 0 LANGUAGE
TNEMTSUJDA
METI
EGNAR
ATAD
DRADNATS
SERVICE DATA NAME
ATAD
CCD (Closed Caption Decoder)
METI
REBMUN
0 PHCC 36-0 83 DX/CC&XEDNIISOPHDSO 1NHCC36-092NOITCNUFON
TNEMTSUJDA
METI
EGNAR
ATAD
DRADNATS
SERVICE DATA NAME
ATAD
ADJUSTM'T
SETTING
FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED
IGEROTUAFOATADTESFFOTNECHNEERG
FIXED
IGEROTUAFOATADTESFFOTNECHDER
FIXED
IGEROTUAFOATADTESFFOWEKSVDER
FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED
FIXED VARIABLE VARIABLE VARIABLE VARIABLE VARIABLE VARIABLE VARIABLE VARIABLE VARIABLE VARIABLE VARIABLE VARIABLE VARIABLE VARIABLE VARIABLE VARIABLE VARIABLE
VARIABLE
IGEROTUAFOATADTESFFOWEKSVNEERG
IGEROTUAFOATADTESFFOWEKSHNEERG
( ) = PREWRITE DATA XXX: CANNOT CHANGE
ADJUSTM'T
SETTING
FIXED FIXED FIXED
ADJUSTM'T
SETTING
FIXED FIXED
KP-43T100/53SV100
OP (Option)
3
IDXT
0-255
2
— 19 —
MOTION PERIOD /INDEX
ADJUSTM'T
SETTING
VARIABLE
FIXED
FIXED
FIXED
3DCM (3D Comb Filter)
KP-43T100/53SV100
METI
REBMUN
0DMRN3-00 EDOMRECUDERESION 1OCYD51-02 2AGYD51-001 3OCCD51-05 4AGCD51-05 5DLES1,01 TCELESD RETLIFLANGISY 6 AG2D 7-0 4 7 HRTV 3-0 1 GNITTESSISERETSYHCNYSHRTV 8 RRTV 3-0 1 GNITTESECNEREFERCNYSHRTV 9 RSDL 3-0 2 ECNEREFERLANGISDL
01 GPAV 7-0 5 NIAGERUTREPAV 11IPAV13-011TNIOPTREVNIERUTREPAV 21TFPY3-00 PATRETLIFGNIKAEPY 31GFPY51-09 NIAGRETLIFGNIKAEPY 41SP1V3-02 ROTCELESENIL-1LACITREV 51SGEV3-01 ROTCELESEGDELACITREV 61 N3CC 1,0 0 RETLIFMOCENIL-3LANGISC 71 PDH 7-0 4 ESAHPLATNOZIROHDH 81 LDC 7-0 5 YALEDC 91 LSSH 51-0 21 LEVELECILSCNYSH 02 LSSV 51-0 8 LEVELECILSCNYSV 12FLPH1,01 RETLIFLLPH 22FLPB1,00 RETLIFLLPTSRUB 32FCSF1,01 NIAGRETLIFCSF 42GFLP1,01 NIAGRETLIFLLP 52DAXE1,00 NIDALANRETXE 62 SSM 1,0 0 LANGISNOITOMDECROF 72 TUOC 3-0 3 TUPTUOLANGISC 82 SPAY 3-0 1 ERUTREPAY 92 SDSN 3-0 0 .TCETEDLANGISDTSNON 03 PPC 3-0 2 EGNARDA&ESLUPPMALC 13OCHY3-01 GNIROCLANGIS.QERFHGIHY
23RLIK51-03 ECNEREFERRELLIK 33SPGB51-04 NOITISOPTRATSPGB 43WPGB51-001HTDIWPGB
53LCDA3-01 63FRWP1,00 73GCHY1,00 832GKC1,01 TIBTSETROTARENEGKCOLC
93EGKC1,00 40 NSDS 0,1 0 NON STD SIGNAL DETECT 41 SYPD 0,1 0 MEMORY POWER DOWN 42 CNRO 0,1 0 CHROMA NOISE REDUCT TEST BIT 43 YNRK 0,1 0 Y NOISE REDUCT FILTER GAIN 44 YNRI 0,1 0 Y NOISE REDUCT FILTER CONV. 45 YNRL 0-3 1 Y NOISE REDUCT FILTER LIMIT 46 CNRK 0,1 0 CHR. NOISE REDUCT FILTER GAIN 47 CNRI 0,1 0 CHR. NOISE REDUCT FILTER CONV. 48 CNRL 0-3 1 CHROMA NOISE REDUCT LIMIT 49 WSC 0-3 1 NOISE DETECTION CORING
TNEMTSUJDA
METI
ATAD
EGNAR
DRADNATS
ATAD
SERVICE DATA NAME
DGNITTESLEVELGNIROCY DGNITTESNIAGY DGNITTESLEVELGNIROCC DGNITTESNIAGC
DGNITTESNIAGdn2C/Y
YALEDKCOLCDA
ECNEREFERHTDIWESLUP
IAG2/1GNIROCLANGIS.QERFHGIHY
N
TIBTSETROTARENEGKCOLC
ADJUSTM'T
SETTING
FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED FIXED
FIXED
TONE (Tone Control)
METI
REBMUN
0 SABR 36-0 ATADSSABEULAVTESER
1 ERTR 36-0 ATADELBERTEULAVTESER
2HEBB51-010 YCNEUQERFHGIHEBB
4 LOOP 7 1 LOOP EFFECT 5
TNEMTSUJDA
METI
LE-3BB1106 YCNEUQERFWOLEBB
EFUS 7 1 TCEFFEDNUORRUS
ATAD
EGNAR
DRADNATS
ATAD
31
31
SERVICE DATA NAME
DAC (D/A Converter)
METI
REBMUN
0HSVU36-013EUHBUSVUY 1CSVU36-013ROLOCBUSVUY
TNEMTSUJDA
METI
ATAD
EGNAR
DRADNATS
ATAD
— 20 —
SERVICE DATA NAME
ADJUSTM'T
SETTING
VARIABLE
VARIABLE
FIXED FIXED FIXED FIXED
ADJUSTM'T
SETTING
FIXED FIXED
PIP (Picture In Picture)
METI
REBMUN
0 FSEL 0-3 0 FIELD SELECT FIXED 1 VACQ 0-15 2 VERTICAL ACQUISITION VARIABLE 2 HACQ 0-15 4 HORIZONTAL ACQUISITION VARIABLE 3 ISYS 0-3 0 INSET DISPLAY SYSTEM FIXED 4 PSYS 0-3 0 PARENT SYSTEM FIXED 5 FACT 0,1 0 FRAME MODE ACTIVATION FIXED 6 HZM 0-7 0 HORIZONTAL ZOOM FIXED 7 VPNR 0,1 0 V SYNC PULSE NOISE REDUCT FIXED 8 VPDL 0-31 8 VERT SYNC PULSE DELAY FIXED 9 FRSL 0,1 0 FRAME SELECT FIXED 10 FRWH 0-7 2 FRAME WIDTH HORIZONTAL FIXED 11 FRWV 0-3 1 FRAME WIDTH VERTICAL FIXED 12 VERB 0,1 0 VERTICAL BLANKING MODE FIXED 13 SELD 0-15 0 SELECT DELAY FIXED 14 PCOR 0,1 1 POSITION CORRECTION FIXED 15 CLDL 0-31 0 CLAMPING DELAY FIXED 16 CLMD 0-3 3 CLAMPING DURATION FIXED 17 CLMS 0-3 2 CLAMPING PULSE START FIXED 18 POFV 0-7 (1) POS. OFFSET FINE V VAR. VARIABLE 19 POFH 0-31 (2) POS. OFFSET FINE H VAR. VARIABLE 20 VSHK 0-31 0 VERTICAL SHRINK FIXED 21 HSHK 0-31 0 HORIZONTAL SHRINK FIXED 22 CLPL 0-3 0 CLAMPING PULSE LENGTH FIXED 23 REFI 0,1 0 REFRESH INTERVAL FIXED
TNEMTSUJDA
METI
ATAD
EGNAR
DRADNATS
SERVICE DATA NAME
ATAD
ADJUSTM'T
( ) = PREWRITE DATA
PYC
METI
REBMUN
0 PSCN 0-15 (8) PIP SUB CONTRAST VARIABLE 1 PSC4 0-15 5 PIP SUB CONTRAST FOR VIDEO 4 FIXED 2 PHUE 0-63 (32) PIP SUB HUE VARIABLE 3 PCOL 0-15 (8) PIP SUB COLOR VARIABLE 4 PCL4 0-15 9 PIP SUB COLOR FOR VIDEO 4 FIXED 5 PBRT 0-15 1 PIP BRIGHTNESS FIXED 6 PBT4 0-15 1 PIP BRIGHTNESS FOR VIDEO 4 FIXED 7 PYDR 0-255 192 PIP Y DRIVE FIXED 8 PYD4 0-255 192 PIP Y DRIVE FOR VIDEO 4 FIXED 9 PUDR 0-255 180 PIP U DRIVE FIXED 10 PUD4 0-255 180 PIP U DRIVE FOR VIDEO 4 FIXED 11 PVDR 0-255 120 PIP V DRIVE FIXED 12 PVD4 0-255 120 PIP V DRIVE FOR VIDEO 4 FIXED 13 PYPD 0-15 1 PIP Y PEDESTAL FIXED 14 PUPD 0-31 (15) PIP U PEDESTAL VARIABLE 15 PVPD 0-31 (15) PIP V PEDESTAL VARIABLE 16 AGCR 0,1 0 AUTO GAIN CONTROL RESET FIXED 17 AGCM 0-3 3 AUTO GAIN CONTROL MODE FIXED 18 AGCV 0-15 12 AUTO GAIN CONTROL VALUE FIXED 19 AGC4 0-15 12 AUTO GAIN CNTRL FOR VIDEO 4 FIXED 20 LMOF 0-3 3 LUMINANCE OFFSET FIXED 21 PLLI 0-3 0 INSET PLL TIME CONSTANT FIXED 22 NRPL 0-3 0 NOISE REDUCTION INSET PLL FIXED 23 PYDL 0-15 0 PIP Y/C DELAY FIXED 24 CSTD 0-7 1 COLOR STANDARD FIXED 25 CEXC 0-3 1 COLOR STANDARD EXCLUSION FIXED 26 LKSP 0,1 0 STANDARD ID SPEED FIXED 27 CKIL 0-3 0 COLOR KILLER THRESHOLD FIXED 28 BGPS 0,1 0 BURST GATE PULSE START POS. FIXED 29 CLON 0,1 0 COLOR ON FIXED 30 ACCF 0,1 0 DISABLE AUTO CHROMA CONTROL FIXED 31 IFFL 0-3 0 IF-COMPENSTATION FILTER FIXED 32 STNR 0,1 0 SATELLITE NOISE REDUCTION FIXED 33 FMAC 0,1 0 FRAME MODE ACTIVATION INSET FIXED 34 CPLL 0,1 0 CHROMA PLL OFF FIXED 35 SCAD 0-31 7 COLOR SUBCARRIER ADJ. FIXED 36 FRMY 0-15 5 FRAME Y LEVEL FIXED 37 YPEK 0-7 7 Y PEAKING ADJUSTMENT FIXED 38 YCOR 0,1 0 Y CORING ENABLE FIXED 39 CHBW 0-3 1 CHROMA BANDWIDTH FIXED
TNEMTSUJDA
ATAD
METI
DTS
EGNAR
SERVICE DATA NAME
ATAD
( ) = PREWRITE DATA
KP-43T100/53SV100
SETTING
ADJ.
SETTING
— 21 —
KP-43T100/53SV100
A
A
f
2-10. REGISTRATION ADJUSTMENT (PJE) FUNCTION OF BUTTONS OF REMOTE COMMANDER FOR PJE MODE ONLY.
TV Power ON
Color Select
djustment
item up
djustment
item down
READ*
data up/down
Resetting the set to the factory shipping condition: Press 8. “RESET” appears in green letters on the screen. Then press ENTER. This resets all customer adjustments, channel memories, and channel labels to the factory shipping settings.
GRN to BLU to RED
Test signal select crosshatch + video signal dots + video signal crosshatch + black dots and black of
Mode select (Course adjustment Fine adjustment)
ENTER
A pattern from an external pattern generator must be used for the main defl ection adjustments.
1. Enter the service mode by quickly pressing the keys on the remote commander in the standby mode in the following order:
Press “DISPLAY,” 5, Volume +, and then “TV POWER”
2. Change from TV mode to video input mode.
3. Input a cross-hatch pattern from an external generator that allows you to properly center and size (over-scan) the pattern.
4. Select adjustment category “VPNT”, adjustment item 0 “VPOS”. Adjust the data so that the external pattern is centered vertically.
5. Select adjustment category “VPNT”, adjustment item 1 “VSIZ”. Adjust the data so that the external pattern is correctly sized vertically. “Correctly sized” means that the picture is overscanned by 7.5%, i.e. only 92.5% of the picture is on the viewable area of the screen. Confi rm that the pattern is still correctly centered vertically.
6. Select adjustment category “VPNT”, adjustment item 5 “HPOS”. Adjust the data so that the external pattern is centered horizontally.
7. Select adjustment category “VPNT”, adjustment item 6 “VSIZ”. Adjust the data so that the external pattern is correctly sized horizontally. “Correctly sized” means that the picture is overscanned by 7.5%, i.e. only 92.5% of the picture is on the viewable area of the screen. Confi rm that the pattern is still correctly centered horizontally.
8. Write the new sizing and centering data to memory by pressing “MUTING” and then “ENTER”.
9. Change the VPNT mode to “PJE 00 FDIS” (press “2” on the remote until “PJE” appears on the top left corner of the screen). If “FDIS” is not displayed below “PJE”, press “4” until it does appear.
Note: Internal patterns are used for geometry and convergence adjustments. However, sizing and centering must be done with the
PJE 00 00 FDIS
use of an external generator. The recommended pattern would be a monoscope, or equivalent pattern, which would provide the means to adjust both the linearity and the sizing of the picture. A cross-hatch pattern with sizing markers can be used in place of a monoscope.
10. Press the remote joystick button up arrow to set the FDIS data to
SETUP FOR ADJUSTMENT
Current fl ow in circuit should be stable before attempting adjustment. Wait 5 minutes after turning on power to the set.
• At the 4 sides of the screen, locate the middle. Use a tape measure to identify the middle.
“01” to display the registration data of each area of the screen in the fi ne adjustment mode.
PJE 00 01 FDIS
11. Press 6 to display the test signal (crosshatch) on the screen.
12. Select GRN CENT(*) with the 1 and 4 keys on the remote
: middle
NOTE: The following steps # 1 through 8 are “main” defl ection adjustments for sizing and centering. “Main” defl ection adjustments
commander.
(H) (V)
GRN ### ### CENT
affect all three CRTs at the same time. The “sub”-defl ection adjustments that follow are made for each CRT individually. If the centering and sizing is performed correctly in “main” defl ection adjustments, only minor touchups may required for the green CRT in “sub”-defl ection adjustment mode.
— 22 —
KP-43T100/53SV100
*: In the factory preset, “GRN CENT” appears on the screen fi rst. To
change the color to red or blue, press the 3 key.
13. Cover the red and blue picture lenses with lens caps to allow only green to show, or use the method shown in the note below to turn the CRTs off individually.
Adjustment type
Display Adjustment item G R B
H/V* H/V* H/V* CENT CENTER -/- O/O O/O SKEW SKEW O/O O/O O/O SIZE SIZE -/- O/O O/O LIN LINEARITY -/- O/- O/­KEY KEY STONE -/- -/O -/O PIN PIN CUSHION -/O -/O -/O
* H = Horizontal V = Vertical O = Yes - = No
Note: If lens caps are unavailable, you can cut off the unnecessary color beams in the service mode by individually changing the data from “1” to “0” in category VPNT, item 28 RON (red), item 29 GON (green), or item 30 BON (blue).

2-11. GREEN REGISTRATION ADJUSTMENT

GREEN CENTER, GREEN SIZE
The sizing and centering that was performed in the previous section (section 2-10) should have correctly sized and centered the green CRT. The sizing and centering (coarse adjustment mode) of the red and blue CRTs in following sections are performed so that the red and blue patterns overlay the green pattern as close as possible prior to the fi ne mode adjustments. The fi ne-mode adjustments are made for all 3 colors so that the cross-hatch lines are straight vertically and horizontally, and the linearity and convergence is correct.
GREEN PINCUSHION
1. Select GRN PIN with the 1 and 4 buttons on the remote commander.
2. Adjust the top and bottom crosshatch lines so that they are straight.
GRN
XXXX 000
PIN
Note: These are required when either severe misadjustment or data loss has occurred.
3. Press “MUTING” then “ENTER” to write the new adjustment data into memory.
GREEN FINE ADJUSTMENT
Press “MUTING” then “ENTER” often during the fi ne adjustment mode to save the adjustment data.
1. Press the 6 button until the external pattern disappears and the TV’s internal cross-hatch pattern appears.
2. Press the 9 button on the remote commander to shift to the fi ne adjustment mode. The green cursor will appear in the center of the screen.
3. Use the 1 and 4 buttons on the joystick on the remote commander to move the cursor (see below) to each area of the screen that you want to adjust, and adjust with the joystick arrow buttons on the remote.
GREEN SKEW
1. Display a cross-hatch pattern from an external generator.
2. Confi rm that category “PJE” is selected (refer to step 9 in the previous section, section 2-10).
3. Make sure that only the external pattern is displayed. If the internal cross-hatch is displayed, press the 6 button on the remote until only the external pattern is displayed.
4. Select GRN SKEW with the 1 and 4 buttons on the remote commander.
5. Using the joystick buttons on the remoter commander, adjust the crosshatch lines so that they go straight vertically and horizontally, not slanting.
GRN SKEW
000 000
6. Press “MUTING” then “ENTER” to write the new adjustment data into memory.
Cursor movement by the 1 and 4 keys:
Alternative method of moving the cursor.
Press the joystick center button once which will cause the cursor to change from green to white. When the cursor is white you can move it up or down, left or right, by using the joystick arrow buttons.
4. Press the joystick center button once; the cursor will return to green (or red or blue, depending on the previously selected color). When the cursor is green, you can adjust the geometry of the area surrounding the cursor by using the joystick arrow buttons.
— 23 —
KP-43T100/53SV100
FINE ADJUSTMENT
1. Press the 9 button on the remote commander to shift to the fi ne adjustment mode; the red cursor appears at the center of the screen. If the cursor is not red, press the 3 button until it is red.
2. Use the 1 and 4 buttons on the remote commander to move the cursor to each area of the screen you want to adjust.
3. Press “MUTING” and then “ENTER” to save the adjustment data.
5. Press the 9 button on the remote commander to return to the coarse adjustment mode. If you need to return to the fi ne mode, just press the 9 button again, and the cursor will change from white to green or blue or red.
6. After the green lines are all straight, press “MUTING” and then “ENTER” to save the adjustment data.

2-12. RED REGISTRATION ADJUSTMENT

RED CENTER, SKEW
1. Cover the blue picture lens with a lens cap to allow green and red to show (or use the method shown in the note below).
2. Press the 3 button on the remote commander to change the GRN mode to the RED mode.
3. Select RED CENT or RED SKEW with the 1 and 4 buttons on the remote commander and adjust while tracking each one alternately.
4. Adjust the red crosshatch lines using the joystick arrow buttons, so that they are straight vertically and horizontally, and overlap the green lines.
5. Press “MUTING” and then “ENTER” to save the adjustment data.
Note: If lens caps are unavailable, you can cut off the unnecessary color beams in the service mode by individually changing the data from “1” to “0” in category VPNT, item 28 RON (red), item 29 GON (green), or item 30 BON (blue).
RED SIZE, LINEARITY
1. Alternately select RED SIZE (vertically and horizontally) or RED LIN (vertically) with the 1 and 4 buttons on the remote commander and adjust while tracking each one alternately.
2. Adjust the red crosshatch lines with the joystick on the remote commander until they are straight vertically and horizontally and they overlap the green lines.

2-13. BLUE REGISTRATION ADJUSTMENT

1. Remove the lens cap from the blue picture lens to show all colors (or use the method shown in the note above to turn on all 3 CRTs).
2. Press the 3 button on the remote commander to shift the RED mode to the BLU mode.
3. Adjust BLU CENT, BLU SKEW, BLU SIZE, BLU LIN, BLU KEY and BLU PIN the same way as the red registration adjustment.
FINAL CHECK- IMPORTANT This must be performed before leaving the service mode!
1. Store the fi nal adjustment data by pressing MUTING and then ENTER.
2. Press the FLASH FOCUS button on the front panel.
3. If an error message appears, refer to the following.
If an error code is displayed after the set has been correctly adjusted, check the following items: position, tilt and sizing. If any of these adjustments are off, even slightly, the auto-registration pattern will not hit the four sensors properly. This occurs when the internal generator patterns are being fl ashed on the screen for the sensors to read. Therefore, auto registration (called auto-focus) cannot operate properly, causing an error code to be displayed. In order for this function to operate properly, position, tilt and size must be adjusted properly.
Note: In case of replacing CRTs, adjust the set-up adjustments (items 2-1 to 2-8) and the registration adjustment (item 2-10). In the case of replacing multiple CRTs at the same time, replace and adjust them individually.
RED KEY, PINCUSHION
1. Select RED KEY or PINCUSHION with the 1 and 4 buttons on the remote commander and adjust each one while tracking each other.
2. Using the joystick arrow buttons, adjust the red crosshatch lines so that they are straight horizontally and vertically, and they overlap the green lines.
Note: These are required when either severe mis-adjustment or data loss occurred.
3. Press “MUTING” and then “ENTER” to save the adjustment data.
— 24 —
KP-43T100/53SV100

2-14. AUTO REGISTRATION ERROR CODE LIST

If an error code is displayed after the set has been correctly adjusted, check the following items: position, tilt and sizing. If any of these adjustments are off, even slightly, the auto-registration pattern will not hit the four sensors properly. This occurs when the internal generator patterns are being fl ashed on the screen for the sensors to read. Therefore, auto registration (called auto-focus) cannot operate properly, causing an error code to be displayed. In order for this function to operate properly, position, tilt and size must be adjusted properly.
ERROR CODE LIST
ERROR
CODE DESCRIPTION NOTE
00 No Error 10 Sensor Output Level Low * Check wiring, beam position, sensor 0 : Upper Center
1 : Middle Left 2 : Middle Right 3 : Lower Center
20 Sensor Output Level High * Check OP-amp circuit 0 : Upper Center
1 : Middle Left 2 : Middle Right
3 : Lower Center 30 Adjustment Loop Counter Overflow * Check the registring information on the convergence board 40 Regi Data Overflow 50 Regi Data Overflow 60 Offset Overflow 70 Offset Overflow
* Check the convergence yoke driver ICs.
* Convergence patterns displayed are out of normal range.
* In the case of multiple errors, last error is displayed.
• ERROR CODE SCREEN DISPLAY SENSOR POSITION
E 11 B
E 11 B
R. G. B
12
0
SCREEN
SENSOR NUMBER
ERROR CODE 10
ERROR
3
* Error code will be displayed at the center of screen for 3
• ERROR CODE DISPLAY DURING AUTO-REGISTRATION IN SERVICE MODE
PJE 2 9 1 4 0 ERR
ITEM NUMBER-29
SENSOR NUMBER (ONLY "10"or "20")
ERROR CODE 40
R.G.B
G-0 (Blank) R-1 B-2
0 : UPPER SENSOR
1 : LEFT SENSOR
2 : RIGHT SENSOR
3 : LOWER SENSOR
— 25 —

SECTION 3: SAFETY-RELATED ADJUSTMENTS

KP-43T100/53SV100
G BOARD

3-1. HV REGULATION CIRCUIT CHECK AND ADJUSTMENT

When replacing the following components marked with a Y on the schematic diagram always check the HV regulation, and if necessary re-adjust.
X
: C517
Y
: C517, C521, C522, IC654, L504, T502, T504 (FBT),
DY, A board, G board
OPERATION CHECK of 31.0KV +1.0 KV DC/ -2.5 KV DC
1. Connect an HV static voltmeter to the unused socket of the high­voltage block. (Fig. 3-1)
2. Power on the set.
3. Display a dot pattern through the VHF/UHF input (PICTURE and BRIGHTNESS set to minimum)
4. Check that the HV static voltmeter is reading
31.00 KV +1.0 KV DC / -2.5 KV DC.
HV Regulation adjustment
1. Connect a HV static voltmeter to the unused socket of the high­voltage block.
2. Power on the set.
3. Display a dot pattern through the VHF/UHF input (PICTURE and BRIGHTNESS to minimum).
4. If anode voltage is 31.95kV or higher, change the value of C517 from 470pF/2kV to 1,000pF/2kV, and confi rm that the high voltage is within the range specifi ed above.
5. If anode voltage is 29.45kV or lower, change the value of C517 from 470pF/2kV to 100pF/2kV, and confi rm that the high voltage is within the range specifi ed above.
Remove the cap from the unused terminal and connect a static voltmeter here.

3-2. HV HOLD DOWN CIRCUIT OPERATION CHECK AND ADJUSTMENT

When replacing the following components marked with a Y on the schematic diagram always check the hold-down voltage and re-adjust when necessary.
X
: R536, R545
Y
: C516, C536, D506, D507, D522, IC206, IC502, IC654, L504, R511, R522, R536, R538, R545, R548, R584, T502, T504 (FBT), DY, A board, G board
OPERATION CHECK
1. Unplug connector CN652.
2. Connect an HV static voltmeter to the unused socket of the high­voltage block.
3. Connect a 220Ω/200W resistor, across pin 2 and pin 1 of CN652, and connect an external DC power supply (200V, class 2A) to pin 3 of CN652.
4. First, turn on the external power supply (+B=135V), then turn on the power to the set.
5. Display a dot pattern through the VHF/UHF input (PICTURE and BRIGHTNESS to minimum).
6. Gradually increase the value of the external DC power supply and check that the hold-down circuit operates at a static HV voltmeter reading of 33.5±1.0kVdc when the set shuts down.
7. Remove AC power from the set, then remove the 220/200W resistor and reconnnect CN652.
HV HOLD-DOWN ADJUSTMENT
1. Repeat steps 1-8 above.
2. If hold-down voltage is 34.5kV or higher, remove R536, mount a resistor (150kΩ, 1/4W : RN) onto R545 instead, and check again if the hold-down voltage is within the standard range.
3. If hold-down voltage is 32.5kV or lower, mount a resistor (220k, 1/4W : RN) onto R536 and check again if the hold-down voltage is within the standard range.
NOTE: Finish the adjustment as soon as possible.
— 26 —

3-3.+B MAX VOLTAGE CONFIRMATION

The following adjustments should always be performed when replacing IC654.
1. Supply 130V +/- 2V AC to the set.
2. Display a dot pattern through the video-1 input.
3. Set the PICTURE control and the BRIGHTNESS control to minimum.
4. Confi rm the voltage of G BOARD test point TP135V is less than
137.0Vdc.
5. If step 4 is not satisfi ed, replace IC654 and repeat above steps.

3-4.+B OVP CONFIRMATION

1. Connect the voltmeter between test point TP OVP and ground.
2. Supply 120VAC to the set using an isolation transformer.
3. Set an adjustable external 150-Volt DC power supply to 120 VDc, and connect it to test point OVP.
4. Power on the set.
5. Set PICTURE and BRIGHTNESS controls to minimum.
6. Gradually adjust the external DC supply towards 150 VDc, and make sure the set shuts down when the external supply’s voltage is between 139 VDC and 159 VDC.
KP-43T100/53SV100
— 27 —
5

SECTION 4: CIRCUIT ADJUSTMENTS

KP-43T100/53SV100
4-1.TV INPUT SUB CONTRAST ADJUSTMENT (VPNT-SCON)
1. Display a color bar signal through the TV’s VHF/UHF input.
2. Mode: Personal 1 or 2
PICTURE:............... maximum COLOR:...................... minimum
BRIGHTNESS: ............. center COLORTEMP: ................neutral
3. Enter the service mode.
4. Turn off the blue and red CRTs by changing the data from “1” to “0” in category VPNT item 28 RON (red), and item 30 BON (blue). If this step is not followed, the ABL circuit may prevent you from adjusting the peak-to-peak amplitude to 1.8 V.
5. Connect an oscilloscope between pin 7 of CN204 (A board) and ground.
6. Select adjustment category “VPNT” adjustment item 19 “SCON”, and adjust using the 3 or 6 button on the remote so that the wave form level is 1.80 ± 0.05Vp-p.
White
1.80 ± 0.05 Vp-p
4-3.COMPONENT INPUT SUB-HUE AND SUB­COLOR ADJUSTMENT (DAC-UVSH, UVSC)
1. Select VIDEO 4 and display a color bar signal.
2. Mode: Personal 1 or 2
PICTURE:............... maximum COLOR:...........................center
BRIGHTNESS: ............. center COLORTEMP: ................neutral
3. Enter the service mode.
4. Connect an oscilloscope between pin 5 of CN204 (A board) and ground.
5. Alternately select adjustment category “DAC”, adjustment item # 0 “UVSH” and item #1 “UVSC” and adjust them so that VB1 = VB4 and VB2 = VB3 as shown below.
VB1
VB2 VB3
6. Press “MUTING” and then “ENTER” to save the adjustment data.
VB4
Black
7. Press “MUTING” and then “ENTER” to save the adjustment data.
4-2.VIDEO INPUT SUB-HUE AND SUB-COLOR ADJUSTMENT (VPNT-SHUE, SCOL)
1. Display a color bar signal through a video input.
2. Mode: Personal 1 or 2
PICTURE:............... maximum COLOR:...........................center
BRIGHTNESS: ............. center COLORTEMP: ................neutral
3. Enter the service mode.
4. Connect an oscilloscope between pin 5 of CN204 (A board) and ground.
5. Alternately select adjustment category “VPNT” adjustment item #20 “SHUE” and item #21 “SCOL”, and adjust them so that VB1 = VB4, and VB2 = VB3 as shown below.
VB1
VB2 VB3
VB4
4-4.PIP SUB CONTRAST ADJUSTMENT (PYC-PSCN)
1. Display a color bar signal through the TV’s VHF/UHF input.
2. Mode: Personal 1 or 2
PICTURE:............... maximum COLOR:...................... minimum
BRIGHTNESS: ............. center COLORTEMP: ................neutral
3. Enter the service mode, and then select the PIP (Picture-in-Picture) mode.
4. Select an unused video input for the main picture (it must be black), and select the tuner for the small picture (it must be showing colorbars).
5. Connect an oscilloscope between pin 7 of CN204 (A board) and ground.
6. Select adjustment category “PYC”, adjustment item # 0 “PSCN” and adjust so that the peak-to-peak voltage is 1.65 ± 0.05Vp-p as shown below.
White
1.65 ± 0.0
6. Add 2 to the adjusted value of “SCOL”.
7. Press “MUTING” and then “ENTER” to save the adjustment data.
Black
7. Press “MUTING” and then “ENTER” to save the adjustment data.
— 28 —
KP-43T100/53SV100
4-5.PIP SUB-HUE , SUB-COLOR ADJUSTMENT (PYC-PHUE, PYC-PCOL)
1. Display a color bar signal through the TV’s VHF/UHF input.
2. Mode: Personal 1 or 2.
PICTURE:............... maximum COLOR:...........................center
BRIGHTNESS: ............. center COLORTEMP: ................neutral
3. Enter the service mode and select the PIP mode.
4. Connect an oscilloscope between pin 5 of CN204 (A board) and ground.
5. Select an unused video input for the main picture (it must be black), and select the tuner for the small picture (it must be showing colorbars).
6. Alternately select adjustment category “PYC”, adjustment item # 2 “PHUE” and item #3 “PCOL” and adjust them so that VB1 = VB4 and VB2 = VB3 as shown below.
VB1
VB2 VB3
7. Press “MUTING” and then “ENTER” to save the adjustment data.
VB4
4-7.PIP POSITION ADJUSTMENT (PIP-POFV, POFH)
1. Select the PIP mode.
2. Display any signal in the PIP window.
3. Alternately select adjustment category “PIP”, adjustment item # 18 “POFV” and item #19 “POFH” and adjust so that the PIP window is equally spaced from the screen edge in each position on the screen as shown below. Use the POSITION button on the remote to change the screen position of the PIP window.
X1-X2 < 0.25 sq
Y1-Y2 < 0.25 sq
Y1
Y2
X2X1
4. Write the data into memory, press “MUTING” and then “ENTER”.
4-6.USER-CONTROL BAR GRAPH DISPLAY POSITION ADJUSTMENT (OP-DISP)
1. Select the video-1 input with no signal applied (the screen should be black).
2. Enter the service mode.
3. Press the “Volume +” button so that the volume bar graph is displayed.
4. Check to make sure the bar graph is centered on the screen horizontally. If necessary, select adjustment category “OP”, adjustment item # 0 “DISP”, and adjust so that the bar graph is centered. Adjust the data 1 step at a time, and then display the bar graph again to check its position.
X1
5. Write the data into memory, press “MUTING” and then “ENTER”.
X2
X1 = X2
— 29 —

5-1. CIRCUIT BOARDS LOCATION

S
H1
H2
KP-43T100/53SV100

SECTION 5: DIAGRAMS

H4
CR
H3
CG
A
CB
FA
G

5-2. PRINTED WIRING BOARDS AND SCHEMATIC DIAGRAMS INFORMATION

All capacitors are in µF unless otherwise noted. pF : µµF 50WV or less are not indicated except for electrolytics and tantalums. All electrolytics are in 50V unless otherwise specifi ed. All resistors are in ohms. K=1000, M=1000k Indication of resistance, which does not have one for rating electrical power, is as follows: Pitch : 5mm Rating electrical power :
1
/
W in resistance, 1/
4
: nonfl ammable resistor.
: fusible resistor.
: internal component.
: panel designation and adjustment for repair. All variable and adjustable resistors have characteristic curve B, unless otherwise noted. Readings are taken with a NTSC color-bar signal input. Readings are taken with a 10M digital multimeter. Voltages are DC with respect to ground unless otherwise noted. Voltage variations may be noted due to normal production tolerances. All voltages are in V. S : Measurement impossibillity.
: B+ line
: B-line. (Actual measured value may be different).
: signal path. (RF) Circled numbers are waveform references. The components identifi ed by been carefully factory-selected for each set in order to satisfy regulations regarding X-ray radiation. Should replacement be necessary, replace only with the value originally used.
W and 1/
10
W in chip resistance.
8
X
in this basic schematic diagram have
1
/
W
4
When replacing components identifi ed by adjustments as indicated. If the results do not meet the specifi ed value, change the component identifi ed by the specifi ed value is achieved. (Refer to adjustments in Sections 3-1 and 3-2.)
When replacing the parts listed in the table below, it is important to perform the related adjustments.
Part Replaced (Y) Adjustment (X)
A BOARD & C517, C521, C522, IC654, G BOARD: L504, T502, T504, DY
A BOARD & C516, C536, D506, D507, D522, G BOARD: IC206, IC502, IC654, L504,
R511, R522, R536, R538, R545, R548, R584, T502, T504, DY
Y
and repeat the adjustment until
X
, make the necessary
HV Regulator:
(C517)
HV HOLD-DOWN:
(R536, R545)
— 30 —