User manual S2AS-100 / 200 Solid State Single Phase Meter
Introduction
Range of validity
Purpose
Target group
The present user manual applies to the basic version of the meters:
S2AS-100
•
S2AS-200
•
(for single phase two wire system with installer switch)
(for single phase two wire system without inst. switch)
Explanations without specific type details apply to both types.
The user manual contains all the information required for application of the
meters for the intended purpose. This includes:
•
Provision of knowledge concerning characteristics, construction and
function of the meters
•
Information about possible dangers, their consequences and measures
to prevent any danger
•
Details concerning the performance of all work throughout the service
life of the meters (parametrizing, installation, commissioning, operation,
maintenance, shutting down and disposal)
The contents of this user manual are intended for technically qualified personnel of energy supply companies responsible for the system planning,
installation and commissioning, operation, maintenance, decommissioning
and disposal of the meters.
Conditions
Subdivision
The user of this manual has received instruction in basic electrical principles, in particular the various principal types of circuit for energy measurement.
This user manual is divided in a logical manner suitable for learning and
application, i.e. the individual chapters follow the sequence of information
probably required during the various phases of the service life of the meters. This provides the following structure:
•
Chapter 1Description of unit
•
Chapter 2Safety
•
Chapter 3Construction and Function
•
Chapter 4Control elements and displays
•
Chapter 5Programming / Interrogation Interface
•
Chapter 6Installation and commissioning
•
Chapter 7Data readout
•
Chapter 8Metering testing
•
Chapter 9Detection of faults
•
Chapter 10Decommissioning, disposal
Siemens Metering AG
H 71 0200 0015 en 1st edition
0-3
User manual S2AS-100 / 200 Solid State Single Phase Meter
Table of contents
Table of contents
1Description of unit........................................................................1
User manual S2AS-100 / 200 Solid State Single Phase Meter
Description of unit
Residential metering
Modular design
BS compliant
Terminal
Fig.1General view of meter
The S2AS meters form a family of solid state single phase meters to cover
the whole range of residential metering applications. Single or two rate
register, pulse output and communcation interface according IEC 1107.
The meters can be used for currents up to 100 A.
The meter is equipped with features to enable the detection of fraud
attempts. The meter has a reverse energy register as well as a register
recording the number of power-on hours it sees.
A unique feature is the low power consumption which helps to reduce the
network losses
The meter fulfils the requirements of today’s metering practice, while the
design concept is already prepared to cope with tomorrow’s needs in a fully
liberalised market. Future requirements can be realised in the form of
external circuits incorporated in a module unit that can be adapted to the
basic meter (adaptive meter concept).
Siemens Metering AG
H 71 0200 0015 en 1st edition
1-1
User manual S2AS-100 / 200 Solid State Single Phase Meter
M
M
Description of unit
Case
The meter is housed in a polycarbonate case designed for the easy fitting
of add-on modules. Through its small size and low weight the S2AS meter
saves costs in logistics.
1.1.2 Type designation
S2AS-100
S2AS-200
odule port
Module port
Meter with installer switch
The installer switch allows
the supply to the premises to
be disconnected without
drawing the main fuse or
disconnecting cables
eter without installer switch
1-2
Siemens Metering AG
H 71 0200 0015 en 1st edition
1.2Technical Data
1.2.1 Voltage Values
User manual S2AS-100 / 200 Solid State Single Phase Meter
Description of unit
Rated Voltage
•
Nominal as per IEC 61036....................................................230V + 10%
•
Range for mains input voltages................................. 0.8 up to 1.15 x Un
Note:
1. The meter is fully operational within 4 seconds of the application of a
voltage supply in the above range
2. The meter will power down and inhibit all operations if the mains
voltage falls below 150VAC.
3. Between ISO V and 184 V operation is not guaranteed, however the
meter will not malfunction, corrupt stored data or register spurious
consumption and will power up or down cleanly once the mains input
voltage rises above or below these values.
1.2.2 Current Values
4. The requirements specified in 2 and 4 above, are independent of the
rate of change of the mains input voltage.
5. The meter will remain operational for mains voltage interruptions of up
to 0.2 seconds. For interruptions of greater than 0.2 seconds, the meter
may power down and up again but shall do so without malfunction,
corrupting data or registering spurious electricity consumption.
Basic current Ib
Maximum Current Imax
Maximum measuring range
Creep inhibit circuit operating
................................................................either 10A or 20A
..................................................either 80A or 100A
...........up to 120A without exceeding 5% error
...............................at approximately 40mA
Note: Current sensing is by means of a shunt.
Siemens Metering AG
H 71 0200 0015 en 1st edition
1-3
User manual S2AS-100 / 200 Solid State Single Phase Meter
Description of unit
1.2.3 Frequency values
Rated frequency
1.2.4 Power Consumption
•
voltage circuit burden.............. less than 0.5W and 9VA. Typically 0.4 W
•
VA burden of the current circuit at Imax..........less than 0.25W / 0.25 VA
1.2.5 Measuring accuracy
Accuracy
•
Accuracy class to IEC 61036 ........................................................class 2
Unity Power Factor at 20°C environmental temperature
(*withstand capability between the voltage and current terminals, including
the auxiliary terminals and all metal/conductive parts which the consumer
can touch)
Climatic / Type Approval
...................according to IEC 61036 and OFFER*
*(UK Office of the Electricty Regulator) additional requirements for type
approval of certified meters and indoor meters
1-5