Siemens BTC-1 Installation Instructions Manual

Installation Instructions
Model BTC-1 Backup Tone Card
INTRODUCTION
The Model BTC-1 Backup Tone Card from Siemens Industry, Inc. provides two tones for the MXLV System that can be selected by dipswitches. This card can be installed on top of the ACM-1 to provide backup of the two primary tones should the tone generator of the ACM-1 fail. The BTC-1 can also be installed on the OCC-1 Output Control Card module to provide a default tone when the low power riser fails and when the OCC-1 loses contact with the MMB.
Select the two backup tones on switch S1 by matching SW1-SW4 and SW5-SW8 to the CSG-M (AccuLINK) configuration tone selec­tions. Table 1 on the next page shows the switch settings for each available tone.
For additional information on the Voice System, refer to the MXLV Manual, P/N 315-092036.
INSTALLATION
Remove all system power before installa­tion, first battery and then AC. (To power
up, first connect the AC and then the battery.)
2. Refer to the function section of the CSG-M configuration printout for the tones to be configured.
3. Set the desired tones on switch S1 using dipswitches SW1-SW4 for the first tone selection and dipswitches SW5-SW8 for the second tone selection.
a. Refer to Figure 2 or 3 on page 3
for the location of S1.
b. Refer to Table 1 for the switch set-
tings and their associated tones.
c. Set the tones (See Note at the top
of the next page).
Do not install the BTC-1 on the ACM-1 or OCC-1 until the system is ready for the installation of PC cards. Until then, keep the BTC-1 in its protective bag.
Mounting
The BTC-1 mounts on either the ACM-1 (See Figure 2) or the OCC-1 (See Figure 3) with two snap-in type standoffs and a comb­like connector.
1. Remove the card from its protective bag.
Siemens Industry, Inc. Building Technologies Division Florham Park, NJ
P/N 315-090919-8
1. Install the standoffs and comb connector in the component side of the ACM-1 or the OCC-1, whichever is appropriate. (See Note at top of the next page.)
Siemens Building Technologies, Ltd. Fire Safety & Security Products 2 Kenview Boulevard Brampton, Ontario L6T 5E4 Canada
Figure 1
BTC-1 Backup Tone Card Module
Setting the Tones on Switch 1
Note: Mount on an ACM-1 to provide
a backup for the two primary tones.
Mount on an OCC-1 to provide a default tone in degrade mode when communication to the MXL fails and there is a local alarm detected. This is useful
only if the OCC-1 is providing input to the amplifier.
TABLE 1
GNITTES
ENOT
12345678
00000000
X000X000
0X000X00zH0002
XX00XX00poohWwolS
00X000X0pleY
X0X0X0X0liaW
0XX00XX0edocainrofilaC
XXX0XXX0et
000X000Xlagelll
X00XX00XnroH
0X0X0X0X3edoclaropmeT
XX0XXX0Xetunimrepseslup03tadeslup
00XX00XXwoeY
X0XXX0XXwoL/hgiH
0XXX0XXXlagellI
lagellI
emihC
zH009
unimrepseslup03tadeslupzH009
XXXXXXXXenotzH009
X = Switch closed OR ON; 0 = Switch open OR OFF
Note: To open a dipswitch, press down on the side of the dipswitch marked OPEN. To close a
dipswitch, press down on the side of the dipswitch opposite the side marked OPEN.
To open a slide switch, push the slide to the side opposite the side marked ON. To close a slide switch, push the slide to the side marked ON.
2
Loading...
+ 2 hidden pages