Siemens ACS3110 User Manual

Page 1
SiPass standalone
ACS3110
User manual
Fire Safety & Security Products
Siemens Building Technologies
Page 2
Liefermöglichkeiten und technische Änderungen vorbehalten. Data and design subject to change without notice. / Supply subject to availability. © 2005 Copyright by Siemens Building Technologies AG
Wir behalten uns alle Rechte an diesem Dokument und an dem in ihm dargestellten Gegenstand vor. Der Empfänger anerkennt diese Rechte und wird dieses Dokument nicht ohne unsere vorgängige schriftliche Ermächtigung ganz oder teilweise Dritten zugänglich machen oder außerhalb des Zweckes verwenden, zu dem es ihm übergeben worden ist.
We reserve all rights in this document and in the subject thereof. By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part, nor to make them available to any third party without our prior express written authorization, nor to use it for any purpose other than for which it was delivered to him.
Page 3
1 Basic information.................................................................................... 5
2 Access modes.........................................................................................5
2.1 Tag types ..................................................................................................5
3 Badge type...............................................................................................6
3.1 User badge................................................................................................6
3.2 Master badge ............................................................................................ 6
4 LED indicators......................................................................................... 7
5 Overall time-out....................................................................................... 7
6 Security measures ..................................................................................8
6.1 Missing tag ................................................................................................8
6.2 Anti tamper................................................................................................8
6.3 Anti vandal ................................................................................................8
7 Wake up: Declaring the Program Master..............................................9
8 Declaring the masters ..........................................................................10
9 Change Program Master ......................................................................11
10 Add new user badge.............................................................................12
11 Void user badge .................................................................................... 13
12 Set Night Lock Mode ............................................................................14
13 Unset Night Lock Mode ........................................................................15
14 Add Special User Badge ......................................................................16
15 Declare Remote Programmer ..............................................................17
16 Void badge with a Remote Programmer.............................................18
17 Appendix................................................................................................19
17.1 Tag registration list..................................................................................19
Siemens Building Technologies Fire Safety & Security Products 02.2005
3
Page 4
Page 5
1 Basic information
SiPass standalone is a complete access control system for one door and up to 500 cardholders. SiPass standalone uses 125 kHz proximity technology. For gaining access, it is sufficient to hold the badge close to the reader. For programming purposes, an optional Remote Programmer can be used, which is simply held close to the reader the same way as a user badge. No wiring con­nection is required.
2 Access modes
SiPass standalone can operate in 2 modes:
Access mode Normal access, no door contact monitoring Night lock Access for ”Special user” badges only.
No access for normal user badges.

Basic information

2.1 Tag types
The proximity cards shown in this document remain valid. The old badges com­pared to the new card design are shown in the table below.
Old Typ New
Void Master
Program Master
Add Master
Night lock master
Void
Program
Add
Night lock
User
User
Siemens Building Technologies Fire Safety & Security Products 02.2005
5
Page 6

Badge type

3 Badge type
3.1 User badge
User
Can be used in ”Access” mode only.
Special
Can be used in both, ”Access” and ”Night lock” mode.
3.2 Master badge
Program Master
Master of masters
Add Master
Allows to introduce new badges to the systems memory
Void Master
Allows to delete (void) badges from the systems memory
Night lock master
Switches the system from access mode to night lock mode and back.
6
Siemens Building Technologies Fire Safety & Security Products 02.2005
Page 7
4 LED indicators
Fig. 1 LED indicators

LED indicators

Read indication (yellow) Open (green) Closed (red)
Night lock (red) Add (red) Void (red) Program (red)
5 Overall time-out
In Program Mode, after 30 seconds of inactivity, an error tone sounds, and normal operation resumes.
Siemens Building Technologies Fire Safety & Security Products 02.2005
7
Page 8

Security measures

6 Security measures
6.1 Missing tag
For safety precautions the user is strongly advised to keep records of the ID num­bers and functions of all badges and the names of their users. In case of loss, the specific badges can be voided from memory by entering the badge number on the SiPass standalone Remote Programmer. See Appendix.
6.2 Anti tamper
A tamper alarm is triggered if the unit is ripped off the wall.
6.3 Anti vandal
Thanks to the proximity reading principle, the reader can be installed behind pro­tective surfaces, such as glass, plastic or marble, but not metal.
8
Siemens Building Technologies Fire Safety & Security Products 02.2005
Page 9

Wake up: Declaring the Program Master

7 Wake up: Declaring the Program Master
When powering up a SiPass standalone for the first time, one selected badge must be presented, to be declared as the Program Master. The Program Master may be regarded as a kind of master of masters; it will be instrumental in enabling all other masters and badges.
Uninitialized (user level
New Program Master
Initialized (access mode)
Read Open Closed Night lock Add Void Program
Read Open Closed Night lock Add Void Program
Program Master
Read Open Closed Night lock Add Void Program
Fig. 2 Wake up
Any SiPass 125 kHz Proximity badge can be used as the Program Master. Program the corresponding master cards according to their symbols. For security reasons, carefully guard masters, note their numbers and store
them in a secure place.
Siemens Building Technologies Fire Safety & Security Products 02.2005
9
Page 10

Declaring the masters

A
8 Declaring the masters
SiPass standalone has 3 programming modes which need to be processed before normal operation. When going through these modes the first time, you can directly declare the re­spective masters.
Enter Program Mode
Declare Void Master
Declare
dd
Master
Declare Night Lock Master
Resume normal operation
Read Open Closed
Night lock Add Void Program
Program Master
2 times
Read Open Closed Night lock Add Void Program
New Void Master
Read Open Closed Night lock Add Void Program
New Add Master
Read Open Closed
Night lock Add Void Program
New Night Lock Master
Read Open Closed Night lock Add Void Program
Program Master
Fig. 3 Declaring the master
All programming can be performed with the master cards. Note their numbers
and store them in a secure place.
Be declared Void– / Add– / Night Lock – Master. CAUTION: If the presented Void– / Add– / Night Lock – Masters are already in
memory, this procedure will void them!
10
Siemens Building Technologies Fire Safety & Security Products 02.2005
Page 11
9 Change Program Master
This procedure replaces the old Program Master by a new one. The old Program Master is thereby voided from the SiPass standalone memory and the new badge is declared as Program Master instead. This is helpful if e.g. an other Program Master than the normal one was added to the memory during wake-up. Present the new Program Master a further 5 times to step through the remaining steps, back to Normal mode.
Normal mode
Read Open Closed Night lock Add Void Program
Enter Program Mode
Read Open Closed Night lock Add Void Program
Old Prog. Master
New Prog. Master
Declare new Program Master, enter Void Mode
Read Open Closed Night lock Add Void Program

Change Program Master

Void old Program Master, enter Add Mode
Read Open Closed Night lock Add Void Program
Old Prog. Master
Fig. 4 Change Program Master
Any new / unknown badge can be declared as new Program Master. If change Program Master function is not desired, just present the old Program
Master again the necessary number of times to get to the desired programming step.
11
Siemens Building Technologies Fire Safety & Security Products 02.2005
Page 12

Add new user badge

A
A
10 Add new user badge
Badges which shall be granted access must first be stored in the SiPass stand­alone memory. The Add Master allows new badges to be added which, from then on, will be granted access. Any badge can be added, except Master badges and badges which are already in memory.
Normal operation
Enter
dd Mode
dd new user badges, one by one
Quit Add Mode, enter normal operation
Read Open Closed Night lock Add Void Program
Read Open Closed Night lock Add Void Program
Add Master
New user badge
Read Open Closed Night lock Add Void Program
Read Open Closed Night lock Add Void Program
Add Master
Fig. 5 Add user badge
Any SiPass badge can be added, except those that are already in memory. Keep records of the ID numbers and functions of all badges. Lost badges can be
voided from memory by number, using an optional Remote Programmer.
See Appendix.
12
Siemens Building Technologies Fire Safety & Security Products 02.2005
Page 13
11 Void user badge
Badges which shall be denied access must first be voided from the SiPass stand­alone memory. The Void Master allows badges to be voided which, from then on, will be denied access.
Normal operation
Enter Void Mode
Void user badges, one by one
Quit Void Mode, enter normal operation

Void user badge

Read Open Closed Night lock Add Void Program
Read Open Closed Night lock Add Void Program
Void Master
Old user badge
Read Open Closed Night lock Add Void Program
Read Open Closed Night lock Add Void Program
Void Master
Fig. 6 Void user badge
Any badge can be voided, except Master badges.
13
Siemens Building Technologies Fire Safety & Security Products 02.2005
Page 14

Set Night Lock Mode

12 Set Night Lock Mode
In night lock mode, normal badges will not be granted access. Only Special User Badges are granted access in this mode. Night Lock Mode is switched on with the Night Lock Master
Normal operation
Night Lock Mode
Read Open Closed Night lock Add Void Program
Read Open Closed Night lock Add Void
Program Night Lock Master
Fig. 7 Set night lock
In case of power failure, SiPass standalone will memorize the current status of
the Night Lock.
Badges that are added to memory during Night Lock Mode are entered into
memory as Special User Tags, to be granted access both in Night Lock Mode and in Normal Access Mode.
14
Siemens Building Technologies Fire Safety & Security Products 02.2005
Page 15
13 Unset Night Lock Mode
Only the Night Lock Master can switch Night Lock off. When presenting the Night Lock Master to unset Night Lock, access is granted at the same time. This function is intended for persons who are authorized to enable access for oth­ers, for example to unlock an office building in the morning.
Night Lock Mode
Unset Night Lock
Access (function depends on settings)

Unset Night Lock Mode

Resume normal operation
Read Open Closed Night lock Add Void Program
Read Open Closed Night lock Add Void Program
Night Lock Master
Read Open Closed Night lock Add Void Program
Read Open Closed Night lock Add Void Program
Fig. 8 Unset night lock
In case of power failure, SiPass standalone will memorize the current status of the Night Lock.
15
Siemens Building Technologies Fire Safety & Security Products 02.2005
Page 16

Add Special User Badge

A
14 Add Special User Badge
Special User Badges are granted access both, during Night Lock and during Nor­mal Operation. Unlike the Night Lock Master, they have no effect on Night Lock status. Special User Badges must be added by using the Add Master while SiPass stand­alone is in Night Lock mode.
Night Lock Mode
Enter Add Mode
dd new
Special User Badges
Quit Add Mode, resume
Night Lock Mode
Read Open Clos ed Nig ht lock Add Void Program
Read Open Clos ed Nig ht lock Add Void Program
Add Master
Schlüsselanhänge r
Read Open Clos ed Nig ht lock Add Void Program
Read Open Clos ed Nig ht lock Add Void Program
Add Master
Fig. 9 Add Special User Badge
Any SiPass 125 kHz badge can be added, except badges which are already in
memory as Special User Badges or Master.
Special User Badges can be voided the same way as normal badges (in Void
mode, regardless of the status of Night Lock).
Keep records of the ID numbers and functions of all badges. Lost tags can be
voided from memory by number, using an optional Remote Programmer.
See Appendix.
16
Siemens Building Technologies Fire Safety & Security Products 02.2005
Page 17
15 Declare Remote Programmer
To store a Remote Programmer in the SiPass standalone memory, first show the Program Master to enter Program mode, then present the Remote Programmer while in Program mode. After this, SiPass standalone will resume its normal opera­tion.
Normal operation
Enter Program Mode
Add Remote Programmer

Declare Remote Programmer

Resume normal operation
Read Open Closed Night lock Add Void Program
Read Open Closed Night lock Add Void Program
Program Master
Read Open Closed Night lock Add
1 2 3
Void Program
4 5 6
7 8 9
0 #
*
Read Open Closed Night lock Add Void Program
Fig. 10 Declare remote programmer
17
Siemens Building Technologies Fire Safety & Security Products 02.2005
Page 18

Void badge with a Remote Programmer

2
3
16 Void badge with a Remote Programmer
Using a Remote Programmer, badges or Remote Programmers can be voided by their number. This is useful if badges or Remote Programmers are lost, stolen or damaged beyond use. For this reason it is important to keep records of all added badges, Masters and Remote Programmers.
Program Mode
Read Open Closed Night lock Add
1 2 3
Void Program
4 5 6
Enter Void Mode
9
*
Void Mode
Read Open Closed Night lock Add Void Program
Enter badge number, repeat for each old badge
n n n n n n n
Quit Void Mode
*
*
1 2 3
4 5 6
7 8 9
*
1
0 #
7 8 9
0 #
*
Fig. 11 Void badge with programmer
1 Press key 2 Keep key depressed 3 Move Programmer through the reading range while keeping the key de-
pressed
Fig. 12 Void badge
Any badge or Programmer in memory can be voided. Leading 0’s of the ID number need not be entered
(004290621 can be entered as 4290621).
If the User Programmer is missing or damaged, ask the supplier to perform void-
ing with his backup Programmer.
18
Siemens Building Technologies Fire Safety & Security Products 02.2005
Page 19

Appendix

17 Appendix
17.1 Tag registration list
ID Number
Program Master Void Master Add Master Nightlock Master Remote Programmers
Masters
Users
Date
19
Siemens Building Technologies Fire Safety & Security Products 02.2005
Page 20
Issued by Siemens Building Technologies Fire & Security Products GmbH & Co. oHG D-76181 Karlsruhe
www.sbt.siemens.com
Document no. Edition 02.2005
A24205-A335-B241
Siemens Building Technologies AG
© 2005 Copyright by
Data and design subject to change without notice.
Supply subject to availability.
Printed in the Federal Republic of Germany
on environment-friendly chlorine-free paper.