In the interests of user-safety (Required by safety regulations in some countries) the set should be restored
to its original condition and only parts identical to those specified should be used.
620 TV lines (video input), 720 TV lines (DTV 720P input, Dot by Dot)
PIN MINI
D-
15-
SUB CONNECTOR
(INPUT 1), 5 BNC
CONNECTOR
(INPUT 2):
RGB separate/composite sync/sync on green type analog input: 0–0.7 Vp-p, positive,
75 Ω terminated
CONNECTOR
DVI
ORIZONTAL SYNC. SIGNAL
H
ERTICAL SYNC. SIGNAL
V
(29-
PIN
) (INPUT 3), RGB (DIGITAL), 250–1,000 mV, 50 Ω
: TTL level (positive/negative) or composite sync (Apple only)
: Same as above
12–230 MHz
43–200 Hz
15–126 kHz
9-pin D-sub connector (RS-232C Input Port/Output Port)
1
31
⁄32" × 3
5
/ " (5 × 8 cm) oval × 2, 3 W + 3 W (stereo)
32
AC 110–120/220–240 V
6.2 A/3.1 A
50/60 Hz
575 W
< 2,100 BTU/hour
41°F to 104°F (+5°C to +40°C)
–4°F to 140°F (–20°C to +60°C)
Plastic
38 kHz
Wave length: 650 nm / Max. output: 1 mW / Class II Laser Product
lens, terminal cover, adjustment feet and projecting parts)
41.7 lbs. (18.9 kg) (main body only)
Remote control, Two AA size batteries, Power cord (11'10", 3.6m), RGB cable (9' 10",
3m), PS/2 mouse control cable (3' 3", 1 m), USB mouse control cable (3' 3", 1 m), Remote
mouse receiver, Extra air filter, CD-ROM, LCD projector operation manual, LCD projector
quick reference, Sharp Advanced Presentation Software operation manual
Lamp unit (Lamp/cage module) (BQC-XGV10WU/1), Remote control (RRMCG1564CESA),
AA size batteries, Power cord (QACCU5013CEZZ), RGB cable (QCNW-5304CEZZ), PS/2
mouse control cable (QCNW-5113CEZZ), USB mouse control cable (QCNW-5680CEZZ),
Remote mouse receiver (RUNTK0673CEZZ), Air filter (PFILD0110CEZZ), CD-ROM
(UDSKA0020CEN1), LCD projector operation manual (TINS-6974CEZZ), LCD projector
quick reference (TINS-6980CEZZ), Sharp Advanced Presentation Software operation
manual (TINS-6992CEZZ), Terminal Cover (CCOVA1789CE01)
This SHARP projector uses LCD (Liquid Crystal Display) panels. These
very sophisticated panels contain 1,310,720 pixels (× RGB) TFTs
(Thin Film Transistors). As with any high technology electronic
equipment such as large screen TVs, video systems and video
cameras, there are certain acceptable tolerances that the equipment
must conform to.
Specifications are subject to change without notice.
This unit has some inactive TFTs within acceptable tolerances which
may result in illuminated or inactive dots on the picture screen. This
will not affect the picture quality or the life expectancy of the unit.
If you have any questions about this matter , please call toll free 1-888GO-SHARP (1-888-467-4277).
U.S.A. ONLY
2
XG-V10WU
22
AN-SD1U/S422U
IMPORTANT SERVICE SAFETY NOTES
Ë Service work should be performed only by qualified service technicians who are
thoroughly familiar with all safety checks and servicing guidelines as follows:
WARNING
1. For continued safety, no modification of any circuit
should be attempted.
2. Disconnect AC power before servicing.
BEFORE RETURNING THE PROJECTOR:
(Fire & Shock Hazard)
Before returning the projector to the user, perform
the following safety checks:
1. Inspect lead wires are not pinched between the
chassis and other metal parts of the projector.
2. Inspect all protective devices such as non-metallic
control knobs, insulating materials, cabinet backs,
adjustment and compartment covers or shields,
isolation resistor-capacity networks, mechanical
insulators, etc.
3. To be sure that no shock hazard exists, check for
current leakage in the following manner:
» Plug the AC cord directly into a 120-volt AC outlet,
(Do not use an isolation transformer for this test).
» Using two clip leads, connect a 1.5k ohm, 10 watt
resistor paralleled by a 0.15µF capacitor in parallel
between all exposed metal cabinet parts and earth
ground.
» Use an AC voltmeter with sensitivity of 5000 ohm per
volt., or higher, sensitivity to measure the AC voltage
drop across the resistor (See Diagram).
» All checks must be repeated with the AC plug
connection reversed. (If necessary , a non-polarized
adapter plug must be used only for the purpose of
completing these checks.)
Any reading of 0.3 volts RMS (this corresponds to
0.2 milliamp. AC.) or more is excessive and indicates
a potential shock hazard which must be corrected
before returning the unit to the owner.
Many electrical and mechanical parts in LCD Projector
have special safety-related characteristics.
These characteristics are often not evident from visual
inspection, nor can protection afforded by them be
necessarily increased by using replacement components
rated for higher voltage, wattage, etc.
Replacement parts which have these special safety
characteristics are identified in this manual; electrical
components having such features are identified by “å”
and shaded areas in the Replacement Parts Lists and
Schematic Diagrams. For continued protection,
replacement parts must be identical to those used in the
original circuit. The use of a substitute replacement parts
which do not have the same safety characteristics as
the factory recommended replacement parts shown in
this service manual, may create shock, fire or other
hazards.
AVIS POUR LA SECURITE
De nombreuses pièces, électriques et mécaniques, dans
les projecteur à LCD présentent des caractéristiques
spéciales relatives à la sécurité, qui ne sont souvent
pas évidentes à vue.
Le degré de protection ne peut pas être nécessairement
augmentée en utilisant des pièces de remplacement
étalonnées pour haute tension, puissance, etc.
Les pièces de remplacement qui présentent ces
caractéristiques sont identifiées dans ce manuel;
les pièces électriques qui présentent ces particularités
sont identifiées par la marque “å” et hachurées dans la
liste des pièces de remplacement et les diagrammes
schématiques. Pour assurer la protection, ces pièces
doivent être identiques à celles utilisées dans le circuit
d’origine. L’utilisation de pièces qui n’ont pas les mêmes
caractéristiques que les pièces recommandées par
l’usine, indiquées dans ce manuel, peut provoquer des
électrocutions, incendies ou autres accidents.
WARNING: The bimetallic component has the primary
conductive side exposed. Be very careful in
handling this component when the power is on.
AVERTISSEMENT: La composante bimétallique dispose du
conducteur primaire dénudé. Faire
attention lors de la manipulation de cette
composante sous tension.
3
XG-V10WU
AN-SD1U/S422U
NOTE TO SERVICE
PERSONNEL
UV-RADIATION PRECAUTION
The light source, UHP lamp, in the LCD projector
emits small amounts of UV-Radiation.
A VOID DIRECT EYE AND SKIN EXPOSURE.
To ensure safety please adhere to the following:
1. Be sure to wear sun-glasses when servicing the
projector with the lamp
turned “on” and the top
enclosure removed.
2. Do not operate the lamp outside of the lamp housing.
NOTE POUR LE PERSONNEL
D’ENTRETIEN
PRECAUTION POUR LES RADIATIONS UV
La source de lumière, la lampe UHP, dans le
projecteur LCD émet de petites quantités de
radiation UV.
EVITEZ TOUTE EXPOSITION DIRECTE
DES YEUX ET DE LA PEAU.
Pour votre sécurité, nous vous prions de respecter
les points suivants:
1. Toujours porter des lunettes de soleil lors d’un
entretien du projecteur
avec la lampe allumée
et le haut du coffret retiré.
2. Ne pas faire fonctionner la lampe à l’extérieur du
boîtier de lampe.
3. Do not operate for more than 2 hours with the
enclosure removed.
UV-Radiation and Medium Pressure
Lamp Precautions
1. Be sure to disconnect the AC plug when replacing
the lamp.
2. Allow one hour for the unit to cool down before
servicing.
3. Replace only with same type lamp. Type
CLMPF0064DE01/02 or BQC-XGV10WU/1 rated
100V/200W.
4. The lamp emits small amounts of UV-Radiation, avoid
direct-eye contact.
5. The medium pressure lamp involves a risk of
explosion. Be sure to follow installation instructions
described below and handle the lamp with care.
3. Ne pas faire fonctionner plus de 2 heures avec le
coffret retiré.
Précautions pour les radiations UV
et la lampe moyenne pression
1. Toujours débrancher la fiche AC lors du
remplacement de la lampe.
2. Laisser l’unité refroidir pendant une heure avant de
procéder à l’entretien.
3. Ne remplacer qu’avec une lampe du même type.
Type CLMPF0064DE01/02 or BQC-XGV10WU/1,
caractéristique 100V/200W.
4. La lampe émet de petites quantités de radiation UVéviter tout contact direct avec les yeux.
5. La lampe moyenne pression implique un risque
d’explosion. Toujours suivre les instructions
d’installation décrites ci-dessous et manipuler la
lampe avec soin.
4
XG-V10WU
5
4
55
AN-SD1U/S422U
234567890123456789012345678901212345678901234
UV-RADIATION PRECAUTION (Continued)
23456789012345678901234567890121234567890123
Lamp Replacement
Note:
Since the lamp reaches a very high temperature
during units operation replacement of the lamp
should be done at least one hour after the power
has been turned off. (to allow the lamp to cool off.)
Installing the new lamp, make sure not to touch the
lamp (bulb) replace the lamp by holding its reflector
2.
[Use original replacement only.]
Lamp
1
Reflector
2
DANGER ! –– Never turn the power on without the
lamp to avoid electric-shock or damage of the
devices since the stabilizer generates high voltages
at its start.
234567890123456789012345678901212345678901234
PRECAUTION POUR LES RADIATIONS UV (Suite)
234567890123456789012345678901212345678901234
Remplacement de la lampe
Remarque:
Comme la lampe devient très chaude pendant le
fonctionnement de l’unité, son remplacement ne doit
être effectué au moins une heure après avoir coupé
l’alimentation (pour permettre à la lampe de refroidir).
En installant la nouvelle lampe, s’assurer de ne pas
toucher la lampe (ampoule). Remplacer la lampe en
tenant son réflecteur 2.
[N’utiliser qu’un remplacement d’origine.]
1
Lampe
2
Reflecteur
DANGER ! –– Ne jamais mettre sous tension sans
la lampe pour éviter un choc électrique ou des
dommages des appareils car le stabilisateur génère
de hautes tensions à sa mise en route.
Since small amounts of UV-radiation are emitted from
an opening between the exhaust fans, it is recommended to place the cap of the optional lens on the
opening during servicing to avoid eye and skin ex-
posure (Fig. 1).
Note: Please obtain a lens cap before servicing a
model XG-V10WU that is received without
one.
LENS CAP
Comme de petites quantités de radiation UV sont
émises par une ouverture entre les ventilateurs aspirants, il est recommandé de placer le capuchon
de l’optique optionnelle sur l’ouverture pendant
l’entretien pour éviter une exposition des yeux et la
peau (Fig. 1).
Remarque: Priére de se procurer un capuchon
d'optique acant d'entretien un modéle
XG-V10WU qui est livré sans.
CAPUCHON D'OPTIQUE
Figure 1.
Figure 1.
5
XG-V10WU
AN-SD1U/S422U
Cautions Concerning the Laser Pointer
"COMPLIES WITH 21 CFR SUBCHAPTER J"
SHARP ELECTRONICS CORPORATION
SHARP PLAZA, MAHWAH, NEW JERSEY 07430
LASER RADIATIONDO NOT STARE INTO BEAM
WAVE LENGTH : 650nm
MAX. OUTPUT : 1mW
CLASS II LASER PRODUCT
AVOID EXPOSURE-
RADIATION IS EMITTED
FROM THIS APERTURE.
TEL : 1-800-BE-SHARP
REMOTE CONTROL
MODEL NO. : RRMCG1564CESA
DC3V(1.5VX2PCS.)
MADE IN CHINA
FABRIQUÉ AU CHINE
LASER
U.S.A. ONLY
Précautions Liées au pointeur laser
"COMPLIES WITH 21 CFR SUBCHAPTER J"
SHARP ELECTRONICS CORPORATION
SHARP PLAZA, MAHWAH, NEW JERSEY 07430
LASER RADIATIONDO NOT STARE INTO BEAM
WAVE LENGTH : 650nm
MAX. OUTPUT : 1mW
CLASS II LASER PRODUCT
AVOID EXPOSURE-
RADIATION IS EMITTED
FROM THIS APERTURE.
TEL : 1-800-BE-SHARP
REMOTE CONTROL
MODEL NO. : RRMCG1564CESA
DC3V(1.5VX2PCS.)
MADE IN CHINA
FABRIQUÉ AU CHINE
LASER
U.S.A. ONLY
6
XG-V10WU
2
AN-SD1U/S422U
WARNING:High brightness light source, do not stare into the beam of light, or view directly . Be especially
careful that children do not stare directly in to the beam of light.
WARNING:TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS UNIT TO
For continued
protection against
a risk of fire,
replace only with
same type 15A
250V fuse.
(F1701)
(INLET Unit)
1A 250V
For continued
protection against
a risk of fire,
replace only with
same type 1A
250V fuse.
(F1702)
CAUTION
(POWER Unit)
2A 250V
The lighting flash with arrowhead within a
triangle is intended to tell the user that
parts inside the product are risk of electric
shock to persons.
The exclamation point within a triangle is
intended to tell the user that important
operating and servicing instructions are in
the manual with the projector.
For continued
protection against a
risk of fire, replace
only with same type
P100A, ANZEN
DENGU, 2A, 250V
103°C fuse.(TF701)
A VERTISSEMENT :Source lumineuse de grande intensité. Ne pas fixer le faisceau lumineux ou le regarder
directement. Veiller particulièrement à éviter que les enfants ne fixent directement le
faisceau lumineux.
A VERTISSEMENT :AFIN D’EVITER T OUT RISQUE D’INCENDIE OU D’ELECTROCUTION, NE P AS PLACER
CET APPAREIL DANS UN ENDROIT HUMIDE OU MOUILLE.
ATTENTION
RISQUE
D’ELECTROCUTION NE
PASRETIRER LES VIS, A
L’EXCEPTION DES VIS DE
REPARATION UTILISATEUR
SPECIFIEES
L’éclair terminé d’une flèche à l’intérieur
d’un triangle indique à l’utilisateur que les
pi‘eces se trouvant dans l’appareil sont
susceptibles de provoquer une déchargeélectrique.
Le point d’exclamation à l’intérieur d’un
ATTENTION: POUR EVITER T OUT RISQUE
D’ELECTROCUTION, NE PAS RETIRER LE CAPOT.
AUCUNE DES PIECES INTERIEURES N’EST REPARABLE
PAR L’UTILISATEUR, A L’EXCEPTION DE L’UNITE DE
LAMPE. POUR TOUTE REPARA TION, S’ADRESSER A UN
PRECAUTION
(Unite d’admission)
15A 250V
TECHNICIEN D’ENTRETIEN QUALIFIE.
PRECAUTION
Pour une protection
continue contre les
risques d’incendie,
ne remplacer
qu’avec un fusible
15A 250V du même
type.
(F1701)
(Unite d’admission)
1A 250V
Pour une protection
continue contre les
risques d’incendie,
ne remplacer
qu’avec un fusible
1A 250V du même
type.
(F1702)
PRECAUTION
(Unité de PUTSSANCE)
2A 250V
triangle indique à l’utilisateur que les
instructions de fonctionnement et
d’entretien sont détaillées dans les
documents fournis avec le projecteur.
Pour une protection
continue contre un
risques d’incendie, ne
remplacer qu’avec un
fusible P100A, ANZEN
DENGU 2A 250V,
103°C du même type.
(TF701)
S-VIDEO OUTPUT terminal for INPUT 4, 5 (4-pin Mini DIN)/
AUDIO OUTPUT terminals for INPUT 4, 5
DC 12V OUTPUT
WIRED REMOTE control input terminal
9
XG-V10WU
AN-SD1U/S422U
Operating the Wireless Mouse Remote Control
Remote Control
Front View
MUTE button
POWER buttons
LENS/BLACK
SCREEN button
RIGHT-CLICK/
ENTER button
FREEZE button
ADJUSTMENT
(ON/OFF)
MOUSE/
switch
1.2.34.5.6
Conference Series
VOLUME buttons
(+/–)
LASER POINTER/
MENU button
MOUSE/
ADJUSTMENT
buttons (
INPUT 4, 5, 6 buttonINPUT 1, 2, 3 button
AUTO SYNC button
RESIZE buttonENLARGE button
GAMMA buttonTOOLS button
BACKLIGHT button
'/"/\/|
Top View
Remote control
signal transmitter
Laser
pointer
window
Rear View
)
LEFT-CLICK/
UNDO
button
Bottom View
Bottom View
Wired remote control
input
Inserting the batteries
Press in on the arrow
13
mark and slide in the
direction of the arrow to
remove the battery cover.
Battery
cover
Insert two AA size
2
batteries, making sure
the polarities match the
+ and – marks inside
the battery compartment.
Battery
compartment
Insert the side tabs of
the battery cover into the
slots and press the
cover in until it is
properly seated.
Battery
cover
10
Using the Remote Control as a Wireless Mouse
XG-V10WU
AN-SD1U/S422U
The remote control has the following three functions:
• Projector control
MOUSE/ADJUSTMENT switch
(Remote control)
• Wireless mouse
• Laser pointer
MOUSE
ADJ.
Wireless mouse/
Laser pointer
MOUSE
ADJ.
Projector contr
Remote Control/Mouse Receiver Positioning
• The remote control can be used to control the projector within the ranges shown below.
• The remote mouse receiver can be used with the remote control to control the mouse functions of a connected
computer within the ranges shown below.
• The signal from the remote control can be reflected off a screen for easy operation. However, the effective distance
signal may differ due to the screen material.
Controling the Projector
Remote Control
30˚
23' (7 m)
30˚
45˚
Using the Wireless Mouse
Remote Control
30˚
45˚
30˚
Remote Control
13'(4 m)
11
30˚
120˚
Remote
mouse
receiver
XG-V10WU
AN-SD1U/S422U
Use as a Wireless Mouse
Be sure the supplied remote mouse receiver is connected to your computer.
Slide the MOUSE/ADJUSTMENT switch to MOUSE.
MOUSE mode buttons
BLACK SCREEN
MOUSE
LASER
POINTER
LEFT-CLICK
RIGHT-CLICK
1.2.34.5.6
MOUSE/
ADJUSTMENT
MOUSE
ADJ.
switch
Conference Series
• For one-button mouse systems, use either the LEFT-CLICK or RIGHT-CLICK button.
• Press BACKLIGHT to turn on the backlights of the operation buttons for about five seconds.
Button name
LASER POINTER/MENU
BLACK SCREEN/LENS
RIGHT-CLICK/ENTER
MOUSE/ADJUSTMENT
LEFT-CLICK/UNDO
POWER ON/OFF
VOLUME +/–
MUTE
Position of MOUSE/ADJUSTMENT switch
LASER POINTER (GREEN)
BLACK SCREEN (GREEN)
RIGHT-CLICK (GREEN)
MOUSE (NOT LIT)
ON (NOT LIT)
MOUSE
ADJ.
MENU (RED)
LENS (RED)
ENTER (RED)
ADJUSTMENT (NOT LIT)
UNDO (NOT LIT)
Slide the MOUSE/ADJUSTMENT switch to MOUSE, and press LASER POINTER ( ) to activate
the laser pointer.
1.2.34.5.6
Conference Series
LASER
POINTER
MOUSE
ADJ.
MOUSE/ADJUSTMENT
switch
• When the button is released, the light automatically goes off.
• For safety reasons, the laser pointer automatically goes off after 1 minute of continuous use. To turn it on, release LASER
POINTER ( ) and press again.
Wired Remote Control
When the remote control cannot be used due to the range
or positioning of the projector (rear projection, etc.), connect
a 3.5 mm stereo minijack cable (sold separately) from the
wired remote control input on the bottom of the remote
control to the WIRED REMOTE control input terminal on the
side of the projector.
• The laser pointer and wireless mouse functions can still be
operated wthe wired remote control.
3.5 mm stereo minijack cable
(sold separately)
XG-V10WU
AN-SD1U/S422U
13
XG-V10WU
AN-SD1U/S422U
Connection Pin Assignments
INPUT 1 RGB and OUTPUT (INPUT 1, 2) Signal Input Ports: 15-pin mini D-sub female connector
RGB Input
Analog
1. Video input (red)
2. Video input
(green/sync on green)
3. Video input (blue)
4. Reserve input 1
10
15
5
1
6
11
5. Composite sync
6. Earth (red)
7. Earth (green/sync on green)
RS-232C Port: 9-pin D-sub male connector of the DIN-D-sub RS-232C cable
15
69
Pin No.SignalNameI/OReference
1CDNot connected
2RDReceive DataInputConnected to internal circuit
3SDSend DataOutputConnected to internal circuit
4ERNot connected
5SGSignal GroundConnected to internal circuit
6DRData Set ReadyOutputNot connected
7RSRequest to SendOutputConnected to internal circuit
8CSClear to Send InputConnected to internal circuit
9CINot connected
8. Earth (blue)
9. Not connected
10. GND
11. GND
12. Bi-directional data
13. Horizontal sync signal
14. Vertical sync signal
15. Data clock
DVI Port: 29-pin
C1C2
91816
C32417C4
C5
• *1 Return for +5 V, Hsync. and Vsync.
• *2 Analog R G and B return
• *3 These pins are not used on this equipment.
Pin No.Name
1T.M.D.S. Data 2–
2T.M.D.S. Data 2+
3T.M.D.S. Data 2/4 Shield
4T.M.D.S. Data 4–*
5T.M.D.S. Data 4+*
3
3
6DDC Clock
7DDC Data
8Analog V ertical Sync
9T.M.D.S. Data 1–
10T.M.D.S. Data 1+
11T.M.D.S. Data 1/3 Shield
12T.M.D.S. Data 3–*
13T.M.D.S. Data 3+*
14+5 V Power
15Ground*
1
3
3
16Hot Plug Detect
17T.M.D.S. Data 0–
18T.M.D.S. Data 0–
19T.M.D.S. Data 0/5 Shield
20T.M.D.S. Data 5–*
21T.M.D.S. Data 5+*
C1Analog Red
C2Analog Green
C3Analog Blue
C4Analog Horizontal sync
C5Analog Ground*
2
14
Dimensions
XG-V10WU
AN-SD1U/S422U
Rear View
Side View
Front View
5
/32 (3.9)
(221.85)
64
/
47
8
T op View
17 31/64 (444.2)
1 21/32 (42)
(621.3)
64
/
29
(81.85)24
32
/
7
Side View
(74.5)
16
/
15
2
(414.5)
16
/
5
16
Bottom View
14 51/64 (376)
15
(25.65) 3
64
/
1
1
Units: inches (mm)
XG-V10WU
AN-SD1U/S422U
REMOVING OF MAJOR PARTS
1.Removing the intake cover, intake filter and lamp unit.
1-1. Detach the intake cover.
1-2. Detach the intake filter.
1-3. Loosen the lock screw from the lamp cover and slide the lamp cover off position.
1-4. Remove the three lock screws each from the lamp units 1 and 2, and detach these units.
Intake cover
1-3
Lamp cover
Lamp unit 1
1-4
1-4
Lamp unit 2
1-2
1-1
Intake filter
16
XG-V10WU
AN-SD1U/S422U
2.Removing the front, top and rear panels.
2-1. Remove the ten lock screws from the rear panel. Disconnect the connector (RD) of the remote control receiver
PWB unit 2. Then detach the rear panel.
2-2. Remove the two lock screws from the remote control receiver PWB unit 2. Detach the remote control receiver
PWB unit 2.
2-3. Remove the two lock screws from the lens cover (top) and detach the lens cover (top).
2-4. Remove the four lock screws from the lens cover (bottom) and detach the lens cover (bottom).
2-5. Remove the four lock screws from the shutter holder and detach the shutter holder.
2-6. Take out the shutter.
2-7. Remove the seven lock screws from the front panel.(Long size 2, Short size 5)
2-8. Remove the four lock screws from the top panel.
2-9. Slowly lift the back of the top panel. Disconnect the following connectors: connector (KY) of the operation
unit, connector (L) of the leaf switch, and connector (RE) of the LED PWB unit and remote control receiver
PWB unit 1. Lift and detach both the front and top panels.
2-10. Remove the two lock screws from the LED PWB unit. Detach the LED PWB unit.
2-11. Open the hooks of the remote control receiver PWB unit 1 and take out the remote control receiver PWB 1.
LED PWB unit
2-10
2-8
Top panel
Lens cover (top)
(RE)
2-9
Front panel
2-7
2-3
Lens cover (bottom)
2-6
Shutter
(KY)
(L)
2-8
2-5
2-7
2-11
2-4
2-5
Shutter holder
2-7
Rear panel
Remote control
receiver PWB unit 1
(RD)
2-2
2-1
Remote control receiver PWB unit 2
17
XG-V10WU
AN-SD1U/S422U
3.Removing the reinforcing angles and intake fan duct assembly.
3-1. Remove the four lock screws from the front reinforcing angle and detach this angle.
3-2. Remove the four lock screws from the rear reinforcing angle and detach this angle.
3-3. Remove the five lock screws from the intake fan duct assembly and detach this assembly.
3-4. Remove the two lock screws from the intake cover and detach this cover.
3-1
Front reinforcing angle
3-1
Rear reinforcing angle
3-2
3-2
Intake cover
3-2
3-4
3-3
3-3
Intake fan duct assembly
3-3
18
XG-V10WU
AN-SD1U/S422U
4.Removing the PWBs
4-1. Remove the two lock screws from the DVI connector.
4-2. Remove the five lock screws from the PC I/F PWB. Lift this PWB off the output PWB unit.
4-3. Remove the four lock screws from the cooling fan. Remove the lock screw from the output sub-PWB unit and
disconnect the connectors. Lift the cooling fan and the output sub-PWB unit off the output PWB unit.
4-4. Disconnect the connectors from the output PWB unit.
4-5. Remove the four stud bolts and eight lock screws from the output PWB unit. Lift and detach the output PWB
unit.
4-6. Disconnect the connector (SP) of the signal PWB unit.
4-7. Remove the eight lock screws from the side terminal board.
4-8. Remove the lock screw from the terminal cover and detach the terminal cover.
4-9. Remove the three lock screws from the grounding plate behind the terminal cover and detach the grounding
plate.
4-10. Detach the terminal board from the left-side panel. Lift the input PWB unit and the signal PWB unit off position.
Output
(F6)
(F8)
(S8)
(F7)
(TP)
(S7)
(RP)
(GP)
(BP)
(F5)
(KY)
sub-PWB
unit
(S5)
FRONT
(AZ)
(AS)
(F1)
(RE)
(L)
Cooling fan
Output sub-PWB unit
4-3
4-5
4-2
PC I/F PWB unit
4-5
4-4
(TOP VIEW)
(F4)
(S4)
(S3)
(F3)
(F2)
(RD)
(LL)
(EC)
(RL) (D) (EA)
Output
PWB unit
Output PWB unit
` Note: When reassembling, fit
the projection of the
terminal PWB shield in
the positioning hole of the
left-side panel.
4-5
4-5
4-5
4-1
`
4-8
Signal PWB unit
Input PWB unit
4-6
4-10
Left-side panel
4-7
4-9
4-7
19
XG-V10WU
AN-SD1U/S422U
5.Removing the power/ballast PWB unit assembly.
5-1. Remove the lock screw from the socket holder (with shorter lead) for the lamp unit 1. Slide sideway and
detach the holder.
5-2. Remove the lock screw from the socket holder (with longer lead) for the lamp unit 2. Slide sideway and detach
the holder.
5-3. Disconnect the connectors from the power/ballast PWB unit assembly.
5-4. Remove the six lock screws from the power/ballast PWB unit assembly. Lift and detach this assembly.
6.Removing the inlet PWB unit assembly.
6-1. Remove the three lock screws from the left-side panel at the inlet PWB unit assembly.
6-2. Disconnect the connectors from the inlet PWB unit assembly.
6-3. Remove the two lock screws from the bottom panel at the inlet PWB unit assembly. Lift and detach this
assembly.
7.Removing the optical mechanism unit.
7-1. Remove the five lock screws from the lamp fan assembly.
7-2. Remove the seven lock screws
from the optical mechanism unit.
Lift and detach this unit.
5-1
5-3
(BB)
5-4
(EA)
Power/ballast PWB
unit assembly
(PL)
5-3
(F7)
7-1
Lamp fan assembly
Bottom panel
7-1
5-2
(F6)
7-2
7-1
Optical mechanism unit
Left-side panel
(EC)
6-3
6-2
6-1
(PA)
Inlet PWB unit assembly
20
XG-V10WU
AN-SD1U/S422U
RESETTING THE TOTAL LAMP TIMER
Resetting the counter
» Draw out the lamp to be replaced. Turn on the power and the absence of the lamp is detected. Now reset the total
hour counter.
Resetting procedure
Replacing one lampReplacing both lamps
1Draw out the relevant lamp only.Draw out both the lamps.
2Turn on the main power.
3Press POWER button to LCD projector on.
4
5Turn off the main power. Fit a new lamp into position.
» With just one of the lamps drawn out, the optical mechanism may get unstable in temperature. To avoid this,
the projector comes in the reset mode.
» For two or more projectors, their counters cannot be reset at once using the remote controller. Press the
ENTER key for resetting.
» In the process mode, the historical information is also reset.
The LED indicator at the drawn-out lamp side starts flashing.
Press the ENTER key to reset the counter. The LED indicator goes out.
End
Maintenance Indicator
TEMPERATURE
WARNING indicator
LAMP REPLACEMENT indicator
(LAMP1, LAMP2)
POWER indicator
The internal
temperature is
abnormally high.
The lamp does
not light up.
The POWER
indicator flashes
in red when the
projector is on.
Condition
Problem
· Blocked air intake.
· Clogged air filter.
· Cooling fan breakdown.
· Internal circuit failure.
· Burnt-out lamp.
· Lamp circuit failure.
· The filter cover is open.
· The lens cover is missing.
Possible Solution
· Relocate the projector to an area with
proper ventilation.
· Clean the filter.
· Take the projector to your nearest Authorized Sharp Industrial LCD Products
Dealer or Service Center for repair.
· Carefully replace the lamp.
· Take the projector to your nearest Authorized Sharp Industrial LCD Products
Dealer or Service Center for repair.
· Securely install the filter cover.
· Remove the top lens cover
(CCOVA1785CE01) off the front panel.
21
XG-V10WU
AN-SD1U/S422U
THE OPTICAL UNIT OUTLINE
Layout of the optical system
Note: Layout for positioning the optical system.
★2 Output polarizer R
★2 Output polarizer G
Dichroic coating
(R transmission)
Dichroic coating
(G transmission)
AL-deposited face
Marking
★M2
Dichroic coating
UV absorbing glass
PBS aperture
Fly-eye lens
R-LCD
M5
AL-coated mirror R
RED
B/G reflector
L2(R)
G-LCD
Projection Lens
L2(G)
G/R Reflector
★M3
Marking
L1
Cross dichroic prism
AL-coated mirror B
G03
B-DF
GREEN
G01
PBS
(polarization beam splitter)
Marking
AL-deposited face
Dicroic coating
(B transmission)
Relay lens 1
★2 Output polarizer B
B-LCD
Input polarizer B
Relay lens 3
M6
AL-deposited face
Relay lens 2
G02
BLUE
M4
AL-coated mirror B
UHP lamp
(Light source)
Marking
★ M2 and M3 mirrors have a coat-
ing wedge (for different film thickness). Set up these mirrors, with
their markings positioned as
shown above, so that their
coated faces and both sides be
in the correct directions.
Prism array
★2 See the assemble-illustration
for determing a direction of
the output polarizer.
22
UHP lamp
(Light source)
UV-IR filter
XG-V10WU
AN-SD1U/S422U
CONVERGENCE AND FOCUS ADJUSTMENT
» Place the set in the ceiling-mounted position, open the maintenance door, and start the
convergence and focus adjustments. Make sure the settings are complete and then turn
on the power. For adjusting the image, use the remote controller. Take the following
adjustment procedures.
1. Focusing the projection lens
(A) Replacing all the 3 LCD panels
1. Before replacing all the 3 LCD panels, project an image on the screen and bring it into focus.
2. Replace the panels with new ones. But until the focus has been completely readjusted, be careful not to
change the distance between the set and the screen, nor to move the projection lens focus and zoom
rings.
If the focus is readjusted with a different positional relation, the relation between the projection distance
and the screen size is affected. In other words, a short-distance image (40 WIDE, for example) may get
out of the focus range, or a long-distance image (300 WIDE, for example) may come out of focus.
(B) Replacing 1 or 2 of the 3 LCD panels
1. In adjusting the focus after replacement of one or two LCD panels, project an image on the screen and turn
the projection lens focus ring to get the non-replaced LCD panel into focus.
2. But until the focus has been completely adjusted for the new LCD panels, be careful not to change the
distance between the set and the screen, nor to move the projection lens focus and zoom rings.
(If the distance has been changed or the projection lens readjusted, repeat the above steps 1 and 2.)
2. Adjusting the G-LCD panel
(A) Focus adjustment. (Make this adjustment on the white-only screen.)
1. Right-and-left focus adjustment (θY direction) .
Loosen the lock screws "b" and "c" and insert the eccentric screwdriver into the notch and hole "b". Turn
the screwdriver until the right and left halves on the screen get into focus.
First get the right and left halves in balance. Then improve the accuracy while making the adjustment 2
below.
2. Top-center-bottom focus adjustment (θX and Z directions).
Loosen the lock screws "a" and "c" and insert the eccentric screwdriver into the notch and hole "a" or "c".
Turn the screwdriver until the top, center and bottom on the screen get into focus. In adjusting this top-tobottom focus, temporarily tighten the lock screw "b" to fix the θY direction adjustment.
3. Repeat the above steps 1 and 2 to finely adjust the focus. Finally tighten up all the lock screws.
Notes :
1 Carefully proceed with the focus adjustment because the adjusting directions are correlated.
2 In adjusting the convergence and focus, do not move the projection lens zoom and focus rings until the end
of all the adjustments.
(B) Convergence adjustment
» The G-LCD panel has no convergence adjustment mechanism. Use this panel as convergence adjustment
reference.
3. B-LCD panel adjustment (the same for the R-LCD panel)
(A) Focus adjustment
» T ake the same procedure as for the G-LCD panel focus adjustment. Note that the adjustment range is small
in the Z direction. If the convergence is quite different between the B-LCD and G-LCD panels, roughly adjust
the convergence first and then the focus.
(B) Convergence adjustment
» Use a crosshatch pattern signal for this adjustment.
Make the adjustment just for the G-color and the relevant color.
(1) Loosen the convergence lock screw "d".
(2) With the G-LCD panel’s screen center as reference, adjust the B-LCD panel in the X, Y and θZ directions.
(3) Finally tighten up the convergence lock screw "d".
23
XG-V10WU
AN-SD1U/S422U
Notes :
1 The eccentric cam is used for convergence adjustment. This means that the cam’s turning and the linear
movement are not always uniform.
2 This model is not equipped with the LCD image adjustment mechanism. This is because the dichroic prism
is used for image formation. When the LCD panels all get into the best focus, the images are almost
completely converged.
Convergence and Focus Adjustments Mechanism
BOTT OM VIEWSIDE VIEW
FRONT
Lockscrew"a"
Notchandhole"a"
SIDE VIEW (from outside)SIDE VIEW (from inside)
R-LCD
B-LCD
Lockscrew"c"Notchandhole"c"
θ
X
G-LCDpanelmountingscrews
G-LCD
Notchandhole"b"Lockscrew"b"
X
Y
Z
Notchandhole"c"
Z
θ
Y
X
Lockscrew"c"
Eccentriccam
θ
Y
Z
TOP
G-LCD
Gadjustingplate
RáB-LCD
TOP
Lockscrew"d"
Y
X
θ
Z
(convergence
adjustment)
RáB-LCDpanelmountingscrews
24
Convergence and Focus Adjustments at a Glance
2
5
16
R2
50
CUT
Adjustment directions
AdjustmentDirectionDefinitionDirection of LCD panel
X directionLCD right and left
Convergence Y directionLCD top and bottom
θZ directionRotation around Z axisLCD turning axis
Z directionLCD optical axis
FocusθX directionRotation around X axisLCD top-to-bottom flapping
θY directionRotation around Y axisLCD right-to-left flapping
Convergence and Focus Adjustment for the Optical Mechanism
XG-V10WU
AN-SD1U/S422U
ColorAdjustmentDirection
X direction±0.8mm Eccentric camEccentric cam adjusting wrenchdHex wrench
Convergence Y direction±0.8mm Eccentric camEccentric cam adjusting wrench dHex wrench
Preferably use a 70 mm or longer
screwdriver (with a handle).
XG-V10WU
AN-SD1U/S422U
Replacing the LCDs
Remove the top cover.
(1)Remove the six screws off the relay duct and disconnect the relay duct.
(2)Remove the two screws off the upper suction cover and detach this cover.
(3)Disconnect the LCD flat cable from the PWB connector.
(4)Place the set in the ceiling-mounted position and open the maintenance door.
(5)Remove the lock screws "b" and "c". Take out the LCD-equipped R/B adjusting board and G adjusting board.
(6)Detach the LCD panel from the adjusting board.
(7)Place a replacement LCD panel and take the above steps (1) thru (5) in the reverse order.
~ Keep in mind that the G LCD panel does not need convergence readjustment and that it has a small adjustable
range in the Z direction.
BOTT OM VIEW
Lock
R-LCD
FRONT
5
screws "c"
G-LCD
Lock
5
Lock
screws "c"
screws "b"
5
B-LCD
Z
X
θY
5
Lock
screws "c"
SIDE VIEWSIDE VIEW
R·B adjusting plate
R·B-LCD
Y
X
X
Z
`
G adjusting plate
θY
G-LCD
TOP
θZ
6
R·B-LCD panel
mounting screws
G-LCD panel
6
mounting screws
TOP
26
XG-V10WU
AN-SD1U/S422U
1. Adjusting the mirror optical axis
The optical axis must be readjusted to correct possible eclipse that occurs with the R, G or B LCD panel.
This readjustment is usually required when an optical part in the optical mechanism has been replaced,
and may be needed when a LCD panel has been replaced.
1. Disconnect the LCD flat cable.
2. Get the lamp on. Be sure to start the cooling fan too.
(Eclipse with the R LCD panel: Screen edges appearing in cyan)
3. Loosen the lock screws of the M5 adjusting lever.
4. Watching the image on the screen, turn or slide the M5 adjusting lever until the eclipse disappears from the
screen. Now tighten up the lock screws.
(Eclipse with the G LCD panel: Screen edges appearing in magenta)
3. Loosen the lock screws of the M3 adjusting lever.
4. Watching the image on the screen, turn or slide the M3 adjusting lever until the eclipse disappears from the
screen. Now tighten up the lock screws.
(Eclipse with the B LCD panel: Screen edges appearing in yellow)
3. Loosen the lock screws of the M6 adjusting lever.
4. Watching the image on the screen, turn or slide the M6 adjusting lever until the eclipse disappears from the
screen. Now tighten up the lock screws.
2. Adjusting the orientation of polarizer
The contrast must be optimized when the polarizer or an optical mechanism part has been replaced.
1. Turn on the power.
2. If the background is blue, clear the screen and get it black.
3. Loosen the two lock screws of the polarizer (two for each plate).
4. Press the heads of the lock screws in the arrow directions until the onscreen contrast becomes best. Finally
tighten up the lock screws.
3. Adjusting the PBS
This adjustment may be required when the optical mechanism has been disassembled. Colors uneven
on the right and left halves onscreen can be corrected here. Usually there is no need to make this adjustment. It is enough to have the lamp adjusting groove in alignment.
1. Turn on the power.
2. Loosen the PBS lock screw.
3. Feed a white-only signal, or call the process mode and get the screen white only.
4. Put the eccentric screwdriver (9EQDRiVER-NV1A) in the PBS adjusting groove.
5. Watching the image on the screen, turn the eccentric screwdriver until the right-and-left colors onscreen
become most even. Finally tighten up the lock screw.
4. Adjusting the lamp optical axis
The lamp optical axis is optimized to obtain the best color evenness and brightness. Usually there is no
need to make this adjustment because the replacement lamp unit (BQC-XGV10WU/1) has been delivered
factory-adjusted.
1. Turn on the power.
2. Loosen the three lamp lock screws.
3. Feed a white-only signal, or call the process mode and get the screen white only.
4. Put the eccentric screwdriver (9EQDRiVER-NV1A) in the lamp adjusting groove.
5. Watching the image on the screen, turn the eccentric screwdriver until the right-and-left colors onscreen
become most even. Finally tighten up the lock screws.
27
XG-V10WU
AN-SD1U/S422U
Mirror adjusting
lever lock screws
PBS lock screw
PBS adjusting groove
Lamp adjusting groove
4
1
M5 adjusting lever
R
2
G
M3 adjusting lever
4
1
M6 adjusting lever
Mirror adjusting
lever lock screws
B
1
Mirror adjusting lever
lock screws
Lamp adjusting groove
3
Lamp lock screws
Lamp lock screws
28
XG-V10WU
AN-SD1U/S422U
ELECTRICAL ADJUSTMENT
Hook up a signal generator, or a DOSV or Mac personal computer to the projector in order to feed the
signals specified in the Adjusting conditions.
1. Turn on the power (with the
lamp on) and warm up the
set for 15 minutes.
» Make the following settings.
Press S2601 to call the process mode. Execute
the S2 and S4 commands on the SSS menu. With
the S2 command, all but the PC boards will be
initialized. Do not execute the S1 command
because this will get the PC boards initialized. To
readjust the PC boards, refer to "Adjusting the PC
interface" on page 37.
2RGB drive
adjustment
3RGB1 system
black level
signal amplitude
adjustment
1. Feed the 100% white signal.
2. Select the following group
and subjects.
Group : A/D
Subject : R-D (R)
G-D (G)
B-D (B)
1. Select the following group
and subjects.
Group : OUTPUT1
Subject : G1-BLK
G1-GAIN
For the R and B colors,
choose the following respective subjects.
R1-BLK and R1-GAIN for R
B1-BLK and B1-GAIN for B
2. Make sure the process adjustment color bars are being displayed.
3. Connect the oscilloscope to
pin (3) (for G) of P1001.
4. Similarly connect the oscilloscope to the following for
the R and B colors.
Pin (1) of P1001 for R
Pin (5) of P1001 for B
» Using the set's control switch or the remote
controller's button, adjust the settings so that there
be some bit dropouts.
» Select G1-GAIN. Using the set's control switch or
the remote controller’s button, adjust the setting so
that the signal amplitude be 3.7 ± 0.05 Vp-p.
» Select G1-BLK. Using the set’s control switch or
the remote controller’s button, adjust the setting so
that the white to white level be 2.4 ± 0.05 Vp-p.
» Do the same for the R and B colors.
2.4Vp-p
3.7Vp-p
`The G1 settings affect all the R, G and B signals
at the same time. When the G1-BLK setting has
been changed, therefore, the R1-BLK and B1-BLK
settings are accordingly modified. Also with a
change in the G1-GAIN setting, the R1-GAIN and
B1-GAIN settings are accordingly modified. In
other words, adjust the G settings first and then
the R as well as B settings.
1. Select the following group
and subjects.
Group : OUTPUT2
Subject : R2-GAIN
R2-BLK
For the G and B colors,
choose the following respective subjects.
G2-GAIN and G2-BLK for G
B2-GAIN and B2-BLK for B
2. Connect the oscilloscope to
pin (2) (for R) of P1001.
3. Similarly connect the oscilloscope to the following for
the G and B colors.
Pin (4) of P1001 for G
Pin (6) of P1001 for B
1. Feed the SXGA-mode, 75-
Hz black signal.
2. Select the following group
and subject.
Group : OUTPUT3
Subject : SH-PHASE
» Select R2-GAIN. Adjust the setting so that the
signal component has the minimum amplitude.
» Select R2-BLK. Adjust the setting so that the wave-
form becomes a straight horizontal line.
Adjusted to
» Using the set's control switch or the remote
controller’s button, make sure the characters
OUTPUT3 are not blurry with no ghost image on
the screen. If anything blurry or a ghost image
appears onscreen, readjust the setting in the
range of 7-9.
6RGB
countervoltage
adjustment
7RGB tone
reproduction
adjustment
1. Feed the SXGA-mode, 60-
Hz, countervoltage adjustment signal.
2. Select the following group
and subjects.
Group : OUTPUT3
Subject : RC (R)
GC (G)
BC (B)
1. Feed the Infocom
Grayscale & Color Pattern
signal.
2. Select the following group
and subject.
Group : OUTPUT1
Subject : G1-BLK
» Using the set's control switch or the remote
controller’s button, adjust the setting so that the
flickering be minimum.
» If there is a difference between the center and
both sides on the screen, adjust the setting to get
both sides equal to each other.
» Make sure the grayscale, shown below, is visible
up to the tone 251 (white) as well as down to the
tone 8 (black).
» If the white tone is out of spec, finely adjust the
G1-BLK setting.
4
812
249251
30
Loading...