Plasmacluster and Plasmacluster HD are
trademarks of Sharp Corporation.
IG-A10A
Plasmacluster Ion Generator
OPERATION MANUAL
HD 離子簇抗
菌機
ENGLISH
Read and keep this manual carefully.
請仔細閱讀並妥善保存這本手冊。
使用說明書
中文
FEATURES
SHARP’s Original Air Disinfecting Technology.
Plasmacluster HD helps to improve the air quality by eliminating of
airborne mold*1, viruses*2, allergens*3, and adhering odor*4.
Release Plasmacluster Ions.
1
Pl asmacl uster Io ns are the
same positive and negative
ion s f o und in n a tur e . T h e
ions are surrounded by water
molecules, and are released
into the air.
Attack Airborne microbes.
2
Th e ions form h ydroxide
rad i c als t hat a re hi g hly
oxidizing only when they
adhere to the surfaces of mold
an d virus es. Th ey insta ntly
remove the hydrogen f r o m
the surface proteins, breaking
them down.
Hydroxide (OH) radical
Hydrogen(H)
Protein
Return to the air as water.
3
The hydroxide (OH) radicals
combine with hydrogen (H) to
form water (H2O) which returns
to the air.
Testing and verication Organization.
*1 Ishikawa Health Service Association.
*2 Retroscreen Virology, Ltd, UK.
*3 Hiroshima University.
*4 Japan Spinners Inspecting Foundation.
water (H2O)
GLP*5-compliant test facilities have gathered highly
reliable safety data on Sharp's Plasmacluster
technology.
•Skin irritation/corrosion test
•Eye irritation/corrosion test
•
Inhalation toxicity test (lung tissue genetic impact assessment)
Tested by: Mitsubishi Chemical Safety Institute
*5 GLP(G ood L aboratory Pract ice) is a system of
ma na gem ent c ont ro ls for test fac ili ti es and test
pr oc edu re s des ig ned to e nsu re the rel ia bil it y o f
• While IG-A10A can inactivate and eliminate suspended viruses
and other contaminants, it cannot create a completely sterile
environment. SHARP does not guarantee its ability to prevent
microbial infection.
• To enable stable emission of high-density Plasmacluster ions, the
Plasmacluster Ion Generating Unit mounted in IG-A10A will need
to be replaced periodically*
*Replacement is required approximately every 2 years (17,500 hours) when operated
24 hours a day. IG-A10A will stop operating after about 26 months (19,000 hours) if
the Plasmacluster Ion Generating Unit is not replaced.
Thank you for purchasing this SHARP Plasmacluster Ion Generator. Please
read this manual carefully before using Plasmacluster Ion Generator.
After reading, keep the manual in a convenient location for future reference.
.
E-1
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed, including the following:
WARNING - To reduce the risk of electrical shock, re, or injury :
• Read all instructions before using the unit.
• Use only a 220-240 volt outlet.
• DO NOT use the unit if the power cord or plug is damaged, or the connection to the wall outlet
is loosened.
• Periodically remove dust from the plug.
• DO NOT insert ngers or foreign objects into the air intake or air outlet.
• Always hold the plug and never pull on the cord when removing the power plug.
Electrical shock and/or re from a short circuit may result.
• DO NOT remove the plug when your hands are wet.
• DO NOT use the unit near gas appliances or replaces.
• If the power cord is damaged, it must be replaced by the manufacturer, its service agent, a
Sharp authorized Service Center or qualied person in order to avoid a hazard.
• Be cautious when cleaning the unit.
Strong corrosive cleansers may damage the exterior.
• DO NOT use it in the areas where the unit may get wet.
• DO NOT use spray products near the unit.
•
DO NOT use in the rooms, containing oil component, incense, cigarettes’ sparks, and chemical fumes.
• DO NOT operate when using aerosol insecticides or in rooms where there is oily residue, incense, sparks from lit cigarettes, chemical fumes in the air, or in locations where the unit may
get wet, such as a bathroom.
• Only a Sharp Authorized Service Center should service this Plasmacluster Ion Generator.
Contact the nearest Service Center for any problems, adjustments, or repairs.
• This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety.
• Children should be supervised to ensure that they do not play with the appliance.
CAUTIONS CONCERNING OPERATION:
• DO NOT block the air intake and/or air outlet.
• DO NOT use the unit near or on hot objects, such as stoves or heaters or where it may come
into contact with steam.
• Always operate the main unit in an upright position.
• Clean the exterior with a soft cloth only, otherwise the main unit surface may be damaged or
cracked.
• Keep the main unit away from water.
INSTALLATION GUIDELINES:
• Place at least 2m away from equipment utilizing electric waves such as televisions or radios to
avoid electrical interference when using the unit.
• Avoid using in locations where the unit is exposed to condensation or drastic temperature
changes. Appropriate room temperature is between 0-35ºC.
• Avoid locations where grease or oily smoke is generated, otherwise the main unit surface may
crack as a result.
NOTE - Radio or TV Interference:
If this Plasmacluster Ion Generator may cause interference to radio or television reception,
try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the distance between the unit and radio/TV receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
E-2
PARTS NAME
FRONT
DISPLAY
Unit Replacing
(See E-6)
Light
High
(red)
(blue)
Louvers
(See E-4)
Top Cover Cap
Screws
Air outlet
(blue)
Low
Button
Fan Speed
Indicator
Filter (Air Intake)
BACK
Operation
Top Cover
Plasmacluster Ion
Generating Unit
(See E-6,7)
Filter (Air Intake)
(See E-5)
Use a pointed object, e.g a pen tip, to press
this button after replacing Plasmacluster Ion
Generating Unit.
Do not press it for any other purpose.
(This is to reset the Unit Replacing Light.)
ENGLISH
Power Cord
Plug
E-3
INSTALLATION POSITION
Place the main unit on a smooth,
stable surface in a room and
DO NOT USE the below items near the unit.
TV
FURNITURE
insert the plug into an outlet.
DO NOT hold the louvers when carrying the unit.
Installation Guidance.
Leave at least 15cm of clearance behind the Unit.
UPSIDE More than 1m
BACKSIDE
More than 15cm
LEFT/RIGHT SIDE
More than 20cm
RADIO
silicone-containing products*
SPRAY
*Hair care products, cosmetic products,
water proof sprays, polish glass cleaner,
wipe and wax.
WAX
ATOMIC
CLOCK
PESTICIDE
OPERATION
Press the operation button to directly turn on the power and
select the preferred mode.
LOW
Release high-density
Plasmacluster ions quietly.
Increase the volume of
HIGH
Plasmacluster ions to increase
the purifying capacity.
'OFF'
Power 'OFF'.
Louvers
The air comes from direction, which is stamped on the
louvers.
•When releasing ions to the entire room, put each louver in
an opposite direction.
•When releasing ions to the point to deodorize the adhering
odor on clothes, put both louvers in the same direction
E-4
.
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.