Sharp IG-A20E, IG-A40E Operating Manual

0 (0)

Plasmacluster is a trademark of SHARP Corporation.

IG-A20E

IG-A40E

IG-A20E

IG-A40E

SHARP CORPORATION

Osaka, Japan

 

 

 

Plasmacluster Ion Generator

 

ENGLISH

OPERATION MANUAL

 

Plasmacluster-Ionen-Generator

 

 

DEUTSCH

BEDIENUNGSANLEITUNG

 

Générateur d’ions Plasmacluster

 

 

FRANÇAIS

MODE D’EMPLOI

 

Plasmacluster Ion Generator

 

 

NEDERLANDS

BEDIENINGSHANDLEIDING

 

Ионный генератор Plasmacluster

 

 

РУССКИЙ

ЭКСПЛУАТАЦИИ

РУКОВОДСТВО ПО

 

 

 

Read and keep this manual carefully. Bitte lesen Sie diese Anleitung und bewahren Sie sie auf.

Veuillez lire et enregistrer ces instructions. Lees en bewaar deze instructies.

Прочтите данное руководство и сохраните его.

Printed in Japan

TINS-A390KKRZ 09JK JP 1

ENGLISH

CONTENTS

IMPORTANT SAFETY INSTRUCTIONS ..................E-2

WARNING............................................................................E-2

• CAUTIONS CONCERNING OPERATION ...........................E-2

• INSTALLATION GUIDELINES .............................................E-2

PARTS NAME .........................................................E-3

• CONTROL PANEL ...............................................................E-3

• FIX THE OPERATION COVER BY SCREW .......................E-3 INSTALLATION POSITION .............................................E-4 ACCESSORIES..................................................................E-4

HOW TO INSTALL THE UNIT ........................................E-5 OPERATION .......................................................................E-6

CLEANING AND MAINTENANCE.................................E-7

• MAIN UNIT...........................................................................E-7

FILTER.................................................................................E-7

PLASMACLUSTER ION GENERATING UNIT REPLACEMENT ... E-8

HOW TO REPLACE THE PLASMACLUSTER ION GENERATING UNIT... E-9

SPECIFICATIONS ........................................................... E-11 TROUBLESHOOTING....................................................E-12

While IG-A20E and IG-A40E can inactivate suspended viruses and other contaminants, it cannot create a completely sterile environment. SHARP does not guarantee its ability to prevent microbial infection.

To enable stable emission of high-density Plasmacluster ions, the Plasmacluster Ion Generating Unit mounted in IG-A20E and IG-A40E have to be replaced periodically*.

*Replacement is required approximately every 2 years (17,500 hours) when operated 24 hours a day. IG-A20E and IG-A40E will stop operating after about 26 months (19,000 hours) if the Plasmacluster Ion Generating Unit is not replaced.

Thank you for purchasing this SHARP Plasmacluster Ion Generator. Please read this manual carefully before using Plasmacluster Ion Generator.

After reading, keep the manual in a convenient location for future reference.

РУССКИЙ NEDERLANDS FRANÇAIS DEUTSCH ENGLISH

E-1

IMPORTANT SAFETY INSTRUCTIONS

When using electrical appliances, basic safety precautions should be followed, including the following:

WARNING - To reduce the risk of electric shock, fire, or injury :

Read all instructions before using the unit.

Use only a 220-240 volt outlet.

DO NOT use the unit if the power cord or plug is damaged, or the connection to the wall outlet is loosened.

Periodically remove dust from the plug.

DO NOT insert fingers or foreign objects into the air intake or air outlet.

Always hold the plug and never pull on the cord when removing the power plug. Electric shock and/or fire from a short circuit may result.

DO NOT remove the plug when your hands are wet.

DO NOT use the unit near gas appliances or fireplaces.

If the power cord is damaged, it must be replaced by the manufacturer, its service agent, a Sharp authorized Service Center or qualified person in order to avoid a hazard.

Be cautious when cleaning the unit.

Strong corrosive cleansers may damage the exterior.

DO NOT use it in the areas where the unit may get wet.

DO NOT use spray products near the unit.

DO NOT use in the rooms, containing oil component, incense, cigarettes’ sparks, and chemical fumes.

DO NOT operate when using aerosol insecticides or in rooms where there is oily residue, incense, sparks from lit cigarettes, chemical fumes in the air, or in locations where the unit may get wet, such as bathroom.

DO NOT use these silicone-containing products in the room where the unit is installed.

Only a Sharp authorized Service Center should service this Plasmacluster Ion Generator. Contact the nearest Service Center for any problems, adjustments, or repairs.

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance.

Do not ride on the main unit and do not sit on or lean it, it may cause injury or malfunction.

CAUTIONS CONCERNING OPERATION:

DO NOT block the air intake and/or air outlet.

DO NOT use the unit near or on hot objects, such as stoves or heaters or where it may come into contact with steam.

Always operate the main unit in an upright position. Always unplug the unit before cleaning.

Clean the exterior with a soft cloth only, otherwise the main unit surface may be damaged or cracked.

Keep the main unit away from water.

INSTALLATION GUIDELINES:

Place at least 2m away from equipment utilizing electric waves such as televisions or radios to avoid electrical interference when using the unit.

Avoid using in locations where the unit is exposed to condensation or drastic temperature changes. Appropriate room temperature is between 0-35ºC.

Avoid locations where grease or oily smoke is generated, otherwise the main unit surface may crack as a result.

NOTE - Radio or TV Interference:

If this Plasmacluster Ion Generator may cause interference to radio or television reception, try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the distance between the unit and radio/TV receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

E-2

Sharp IG-A20E, IG-A40E Operating Manual

PARTS NAME

Power cord

Plug

Louvers

(Air outlet of Plasmacluster Ion)

High density Plasmacluster Ion is discharged forward. (Do not put anything in front of the unit.)

Plasmacluster Ion Generating Unit

(Inside)

Please open the cover only when replacing the Plasmacluster Ion Generating Unit.

(See page E-9)

Filter (Air Intake)

*Clean the filter periodically.

*Do not block the air intake or do not put anything into the unit.

CONTROL PANEL

FILTER CLEAN Light (yellow)

UNIT REPLACEMENT Light (red)

HIGH Fan Speed

MEDLOW Indicator (blue)

OPERATION Button

UNIT RESET Button

Press this button for 3 seconds after replacing the Plasmacluster Ion Gennerating Unit. Don't press it for any other purposes.

FILTER RESET Button

After cleaning the filter, plug the power cord and press the FILTER RESET button for 3 seconds.

AUTO RESTART Switch

FIX THE OPERATION COVER BY SCREW

If necessary, operation cover can be fixed by accessary screw.

РУССКИЙ NEDERLANDS FRANÇAIS DEUTSCH ENGLISH

washer

rubber cover

screw

E-3

INSTALLATION POSITION

Place the main unit on a smooth, stable surface in a room, and insert the plug into an outlet. Please note the required clearance.

UPSIDE more than 60cm

BACKSIDE more than 6cm

SIDE more than 60cm

SIDE more than 60cm

Installation Guidance

To secure the performance, do not put anything in front of the unit.

To secure the performance, do not block the air intake or do not put anything into the unit.

If necessary, unit is fixed to the wall using accessary parts or fixed by anchor bolt see page E-5.

DO NOT USE the below items near the unit. silicone-containing products*

SPRAY

WAX

PESTICIDES

*Hair care products, cosmetic products, water proof sprays, polish glass cleaner, wipe and wax.

ACCESSORIES

Operation manual

Tip-resistant kit

Screw kit

Tip-resistant kit

 

Screw kit for operation cover

(In case of fixing the main unit to the wall)

 

 

mounting parts for wall

screw for the

screw (1pc)

rubber cover (1pc) washer (1pc)

(2pcs)

main unit (2pcs)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Anchor bolt, nut, and washer for fixing to the floor and screw for the wall for fixing to the wall are not included as accessory parts.

E-4

Loading...
+ 9 hidden pages