GP1S560
GP1S560
Compact, High Sensing
Accuracty Type
Photointerrupter
■ Features
1. High sensing accuracy (Slit width:
0.15mm
2. Compact (Case height: 6mm
)
)
3. With positionig pin
4. PWB direct mounting type
■ Applications
1. Floppy disk drives
2. VCRs, cassette decks
3. Optoelectronic switches
■ Outline Dimensions (Unit : mm
Internal connection diagram
23
3 Collector
4 Emitter
0.15
C0.5
4 - 0.45
(
2.54
±0.07
)
1
)
+ 0.3
- 0.1
4 - 0.25
+ 0.3
- 0.1
1.50.7
±0.3
8.0
+ 0.2
2.0
- 0.1
1S560
(
)
5.1
±0.15
7.2
14
32
4
4.0
1 Anode
2 Cathode
(
Both sides of detector
and emitter
Slit width
0.6-0
+
6.0
MIN.
12.0
2 - φ 0.7
*Tolerance :± 0.2mm
*( ): Reference dimensions
)
■ Absolute Maximum Ratings
(
Ta = 25˚C
)
Parameter Symbol Rating Unit
Forward current 50 mA
*1
Input
Peak forward current
Reverse voltage 6 V
Power dissipation 75 mW
Collector-emitter voltage 35 V
Output
Emitter-collecter voltage 6 V
Collector current
Collector power dissipation 75 mW
Storage temperature - 40 to + 100 ˚C
*2
Soldering temperature
*1 Pulse width<=100µ s, Duty ratio= 0.01
*2 For 3 seconds
“ In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.”
I
F
I
FM
V
R
1A
P
V
CEO
V
ECO
I
C
P
C
T
opr
T
stg
T
sol
20 mA
- 25 to + 85 ˚COperating temperature
260 ˚C
GP1S560
■ Electro-optical Characteristics
Parameter Symbol Conditions
Forward voltage V
Input
Output Collector dark current I
Transfercharacteristics
Fig. 1 Forward Current vs.
Ambient Temperature
)
mA
(
F
Peak forward voltage V
Reverse current I
Collector Current Ic
Collector-emitter
saturation voltage
Response time
60
50
40
30
Rise time t
Fall time t
V
FM
R
CEO
CE(sat
r
f
IF= 20mA
F
IFM= 0.5A
VR=3V
VCE= 20V
V
CE
I
F
)
IC= 0.2mA
VCE= 2V, IC= 0.5mA
R
L
MIN. TYP. MAX. Unit
- 1.2 1.4 V
-34V
--10µA
--
= 5V, IF= 20mA
= 40mA,
0.2 - - mA
- - 0.4 V
-3890µs
=1kΩ
- 48 100 µ s
Fig. 2 Collector Power Dissipation vs.
Ambient Temperature
120
)
100
mW
(
C
80
75
60
(
Ta = 25˚C
100 nA
)
20
Forward current I
10
0
- 25 0 25 50 75 85 100
Ambient temperature Ta (˚C
Fig. 3 Peak Forward Current vs.
Pulse width<=100 µs
= 25˚C
T
2000
)
mA
1000
(
FM
500
200
100
Peak forward current I
50
20
-2
52525
10
Duty ratio
a
-1
10
40
20
Collector power dissipation P
15
0
)
- 25 0 25 50 75
Ambient temperature Ta (˚C
85
100
)
Fig. 4 Forward Current vs.
Forward Voltage Duty Ratio
500
200
)
100
mA
(
50
F
20
10
Forward current I
5
2
1
1
Ta= 75˚C
50˚C
0
Forward voltage VF (V
25˚C
0˚C
- 25˚C
)
32.521.510.5