SEKONIC L-508Of service manual

Advanced Features
1/2 Step Shutter Speeds
Remove battery compartment cover and set DIP Switch 1 (TIME 0.5) to “ON.” Select shutter speed using Set / Change Dial.
Aperture Priority
Set DIP switch 2 (F. NO.) to “ON”. Select and use Set/ Change Dial to select aperture.
EV Readout
Set DIP switch 3 (EV) to “ON”. Select Ambient mode. Hold Mode button and turn Set/Change Dial until EV readout shows. Depress measure button.
Multi Flash Mode
Set DIP switch 4 (MULTI) to “ON” . Select Cord or Cordless Flash mode. Hold down Mode button and turn Set/Change Dial until MLT (Multi) shows on display. Measures and counts up to 9 cumulative flashes.
Exposure Compensation
Depress both ISO and ISO 2 at the same time and turn Set/ Change dial to compensation desired up to +/- 9.9 EV.
Motion Picture
Turn Set/change dial (shutter speed) past 8000 to show f/s (frames per second). Select desired f/s and depress measure button. Use EV readout to convert EV to Lux or FC with reference charts.
PRINTED IN USA
Quick Guide to the Sekonic L-508
RETRACTABLE
MODE
DIAL FOR:
- - - - - ->
1/4” TRIPOD
SOCKET
DAYLIGHT MODE FLASH W/CORD AUTO RESET CORDLESS FLASH
SPOT/INCIDENT
SELECTOR
SWITCH
ZOOM SPOT EYEPIECE
- - - - -
MEASURE
SET/CHANGE DIAL
ISO/ISO 2
(depress while turning set/change dial to set)
ON/OFF
FLASH CORD
SOCKET
(when cord is attached push measure to trigger flash and measure light)
1*-4* ZOOM SPOT RING
MEMORY
(see instructions)
MEMORY
CLEAR
(see instructions)
AVERAGE/EV BRIGHTNESS DIFFERENCE
(see instructions)
BOOSTER
OUTLET
(for optional
accessories)
DEPRESS WHILE
TURNING SET/CHANGE
Basic Operation - Sekonic L-508
Advanced Features
On/Off
Press Power button.
Icon monitors battery level.
Set ISO or ISO 2
Hold down ISO or ISO 2 button while turning the Set/Change dial. Measurements are calculated for main ISO. Take measurement and hold down ISO 2 button to display exposures converted to ISO 2 setting for Polaroid or other films.
Use as Zoom Spot meter
Turn Spot / Incident Selector Switch to
to select Spot. Turn
1° to 4° zoom spot ring to select measuring angle.
Use as Incident meter
Turn Spot / Incident Selector Switch to to select Incident. Turn collar around Lumisphere to “Up” position.
Measure Brightness / Contrast Difference
Select Incident operation. Turn collar around Lumisphere to”Down” position.
Ambient Reading
Select Ambient mode by holding down Mode button and turning Set / Change Dial. Depress measure button. Turn Set / Change Dial to select alternate shutter / aperture settings.
Cord Flash Reading
Select Cord Flash mode. Insert flash cord, depress measure button.
Auto-Reset Cordless Flash Reading
Select Cordless flash mode. Depress measure button, manually trigger flash.
Memory Function
Take measurement, depress Memory button. Up to 3 readings can be stored and displayed on the analog memory scale. A fourth measurement can also be displayed.
Averaging Function
After two or three measurements are memorized, depress Ave./EV button. Averaged exposure will be displayed in digital and analog readouts. Operates in spot or incident.
Brightness Difference Function
Using Incident operation, with Lumisphere “Down,” after one measurement is memorized, press the Ave./EV button until the EV A displays. Depress and hold down the Measure button. The difference between the last memorized reading or averaged reading and new area measured is displayed in +/­EV in 1/10 steps.
MULTI-FLASH MEMORY/ MULTI-COUNT
BATTERY
SHUTTER SPEED SHUTTER
PRIORITY M MINUTES
S SECONDS F/S FRAMES PER SECOND
DAYLIGHT MODE FLASH W/CORD CORDLESS FLASH
ANALOG MEMORY SCALE
NOTE: DISPLAY WILL NEVER SHOW WITH ALL ICONS DISPLAYED - FOR ILLUSTRATION ONLY
INCIDENT/SPOT
ISO SPEED
+/- COMPENSATION INDICATOR
1/1O DIGITAL F/STOP READOUT
Loading...