SEKONIC L-308DC service manual

Page 1
DC
L-3 0 8
Quick Guide
DC
L-3 0 8
Quick Guide
POWER button LUMISPHERE
MODE button
Liquid Crystal Display(LCD)
ISO button
MEASURING button
UP button
DOWN button
LCD SCREEN
Battery Indicator
Frame Rate, Shutter Angle Illuminance, Shutter Speed
Measuring Mode
g
An
lx fc
EV
Aperture, EV
ISO Display
Custom setting
1) To enter the custom setting mode, hold the MODE button and then press the POWER button to turn the meter ON.
Custom setting Item
CS number
2) Press the UP button or DOWN button to select the desired custom setting number.
3) The Custom setting item will change each time the MODE button is pressed.
CS No. Custom Setting Group Custom Setting Item
CS1 Display mode
“HD_C”
CS2 Increments of T & F
“1.0” “0.5”
CS3 Simplied illuminance
HD_CINE CINE
Full 1/2 1/3
“CINE” “PHOTO”
No Display Lux FC
“N ON E” “ lx ” “fc”
4) Press POWER button to exit Custom Setting mode.
JE2297610
“0.3”
DC
L-3 0 8
Quick Guide
Measuring / Setting mode in each Display mode
Press the MODE button to select a Measuring / Setting mode.
HD CINE mode
Shutter Speed Priority mode
Simplied Illuminance mode
Frame Rate Setting mode
Press MODE button
to select
CINE mode
Frame Rate Prioirty mode
Simplied Illuminance mode
Shutter Angle Setting mode
Press MODE button
to select
PHOTO mode
Shutter Speed Priority mode
Press MODE button
Cord Flash mode
to select
EV mode (Ambient mode)
Auto-reset cordless ash mode
Hold ISO button, and press MODE button to return to the previous Measuring / Setting mode.
DC
L-3 0 8
Quick Guide
Common operation in each mode
Set ISO
Hold ISO button, and press the UP/DOWN buttons.
Use as Incident Meter
Slide Lumisphere over meter cell.
Use as Reected Meter
Slide Lumisphere away to expose meter cell.
Measure Illuminance or Brightness /Contrast Dierence
Clip in at Lumidisc over meter cell.
Calibration compensation function
Calibration compensation can be made in precise 1/10 step increments in a +/- 1.0 EV range. The calibration compensation can be set independently in each Display mode. Select the Display mode in advance in the custom setting function.
1) To enter the calibration compensation mode, hold the ISO button and press the POWER button to turn the meter ON.
Calibration compensation
2) Select the compensation amount by pressing the UP or DOWN button.
3) Press POWER button to exit calibration compensation mode.
Setting Display mode
Compensation amount