Sekonic DIGI MASTER L-718, L-718 DIGI MASTER User Manual

DIGI MASTER L-718
Operating Instructions
SEKONIC

Contents

Parts Designations .......................................... 2
Specifications ................................................ 28
1
Liquid Crystal Display ..................................... 4
Mode Selection and Operation
Reference Table ............................................. 6
Accessories
1. Lumisphare ................................................... 8
2. Lumidisc ........................................................ 8
3. Reflected-light filter ........................................ 9
4. Viewfinder 5° (sold separately) ...................... 9
5. Synchro cord (sold separately) ...................... 9
Preparing the Meter
for Operation
1. Insert the batteries ....................................... 10
2. Checking the batteries ................................. 10
3. Selecting measuring mode .......................... 11
4. Setting ISO sensitivity ................................. 13
5. Setting shutter speed .................................. 13
6. Display lighting ............................................ 14
7. Running-lock for continuous
reading ....................................................... 14
Wireless (cordless) Measurement
using Electronic Flash Unit .......................... 15
Wired Measurement using Flash
Unit with Synchro Cord ................................ 16
Cumulative Measurement using
Electronic Flash Unit ..................................... 17
Ambient Light Measurement ........................ 18
Memory Display Function ............................. 20
Post-Measurement Calculation .................... 22
Contrast Metering for Lighting
Balance .......................................................... 24
Illuminance (Lux) Measurement ................... 25
Adjusting the Balance of the Meter .............. 26
Care of the Meter ........................................... 27

Parts Designations

Lumisphare (interchangeable with
Lumidisc and Reflected Light Filter)
Swivel head
Holder for swivel head
Setting mark for Lumisphare Measuring switch
Power switch
Liquid crystal display
Memory key
F/T selection key
F/EV selection key
Multi-measurement key
2
Carrying strap eyelet Lumidisc
Reflected-Light Filter
(sold separately)
3
UP/DOWN key Mode selection key ISO key Memory-off key
Tripod thread
Battery chamber
Display-light key Slide cover
Synchro terminal
22
24 Synchro cord, 5m length
23

Liquid Crystal Display

(1) b.c. mark (battery check) is
range is exceeded.
is displayed.
limited up to 2.
F-priority mode.
for flash light:
6fps. ~ 128fps.
key depressed.
indicated.
selection.
for cine mode
In case of ambient light
mode), no symbol mark is indicated.
5
displayed when the meter is switched on. (2) Digital value of the measured F-stop or EV is shown (f/1~ f/90 or EV(- 1) ~ EV25), when the meter is used in T-priority mode. (3) F-stop value is set in F-priority mode for ambient light measurement. (4) E.u. (underexposure) or E.o. (overexposure) mark is displayed when the measuring
By pressing F/EV key, the indicated symbol is converted from F to EV, and vice versa. When the meter is used in the flash mode, only F mark
When the meter is used in T-priority mode, (1) F-stop number is also displayed in bar-dot symbols at 1/2 F-stop increments. (2) The measured F-stop values are indicated in bar dot symbol by pressing the memory key after each measurement. The number of memorized values is
Any of the following symbols is displayed depending on the mode
for wireless (cordless) measurement for flash light for wired measurement for flash light
measurement (excepting cine
This display comes into operation when the multi-measurement key is pressed in both modes of wireless and wired measurement for flash light. The number of cumulative flashes is limited up to 9. If it exceeds 9, the E mark (error) is
(1) Battery capacity is shown when the meter is switched on. (2) Bar symbols indicate the fractions of F-stop or EV value.
Display for film speed moves through a range of ISO 3 ~ ISO 8000 by pressing either UP or DOWN key while holding the ISO
(1) Digital value of the measured
shutter speed is shown in this display (30min. ~ 1/8000sec.), when the meter is used in
(2) Shutter speed is set in T-priority
mode;
1sec. ~ 1/500sec.
for ambient light:
30min. ~ 1/8000sec.
for cine scale:
4
Mode Selection and Operation Reference Table
7
6

Accessories

9
1. Lumisphare
Use Lumisphare when you wish to measure incident light for portraits and three-dimensional subjects.
< Mounting > Match the red dot on the Lumisphare frame to the setting mark on the swivel head. Gently rotate the sphare clockwise until it clicks securely into place. To remove, rotate the sphare counter-clockwise.
<Taking measurements>
Point the Lumisphare accurately toward the camera from the subject position. Swivel head is rotatable 270° horizontally and 90° upward.
2. Lumidisc
Use Lumidisc when you wish to measure lighting contrast and lux as well as the exposure of single­dimensional subjects.
< Mounting > Same as for the Lumisphare.
<Taking measurements>
Hold the meter at the subject position and point the Lumidisc accurately toward the light source. When measuring the exposure of two-dimensional subjects, point the Lumidisc toward the camera from the subject position.
3. Reflected-light filter
Use Reflected-light filter when you wish to measure the reflected light (brightness) of subject. Use it to calculate the relative brightness ratio (illumination contrast of subject) for adjusting lighting balance, or when it is difficult to take incident light measurement.
< Mounting > Same as for the Lumisphare.
<Taking measurements>
Point the reflected-light filter accurately toward the subject. When you wish to measure some part of the subject, do so as close to the subject as possible.
4. Viewfinder 5°
(sold separately)
Use Viewfinder in the same way as the reflected-light filter to measure reflected light. With a light acceptance angle of 5° you can make a spot measurement of distant subjects.
5. Synchro cord
(sold separately)
Synchro cord connects the meter to the flash unit for measuring flash light in wired measurement mode. Synchro cord, 5 meters length, has 3 plugs so that it can simultaneously synchronize the meter with the flash unit and the camera. The terminal on the meter has a locking mechanism to ensure a secure connection. To disconnect the cord, simply pull the ring attachment toward you to release the locking mechanism.
8

Preparing the Meter for Operation

1. Insert the batteries
key
10
the meter on again.
3. Selecting measuring mode
DIGI MASTER requires 2 pcs of AA
size pen-light battery (1.5V x 2).
(1) Open the battery chamber cover by sliding it in the direction of arrow. (2) Insert the batteries carefully aligning
(+) and (-) polarities as indicated inside the chamber.
(3) Replace the cover by sliding it and
inserting its notch into the slot of the meter.
< NOTE >
• After changing the batteries, please switch the meter ON once, and then OFF. It prevents the unexpected battery consumption that may occur depending on the status of electric circuit of the meter.
• When not using the meter for a week or more, remove the batteries from the meter. It prevents any internal damage arising from battery leakage.
2. Checking the batteries
Check the battery capacity before using the meter. A weak battery does not assure the correct light readings.
(1) Slide the power switch to ON
position. Then b.c. and dot symbol marks are displayed for about
0.5sec. to indicate the battery level (Fig. 1). If the battery is too weak to give a correct light reading, the b.c. mark flashes.
(2) After checking (for about 0.5sec.),
the display is automatically changed to the measuring mode (Fig. 2). If you wish to keep the b.c. and dot marks indicating, switch the meter ON while depressing ISO key. The marks keep indicating until you stop depressing the ISO
(3) DIGI MASTER is equipped with auto
shut-off function. If you leave the meter inactive for about 5 minutes, the power is automatically switched off. If you wish to use the meter again, slide the power switch back to OFF position once and then switch
11
(3) In the ambient light mode,
12
off or the measuring mode is changed.
measurement (Fig. 10).
meter is switched off.
(a) T-priority measurement or
F-priority measurement can be selected by pressing the F/T selection key (Fig. 7).
(b) EV measurement can be
selected by pressing the F/EV selection key in the F-priority mode (Fig. 8).
4. Setting ISO sensitivity
Press either side of UP/DOWN key while depressing ISO key. Film speed (ISO sensitivity) can be set within the range of ISO 3 ~ ISO 8000 (Fig. 9). The set value of ISO sensitivity is memorized even if the meter is switched
5. Setting shutter speed
Press either side of UP/DOWN key. The display of shutter speed can be changed within the range of 30min. ~ 1/8000sec. for ambient light measurement, and 1sec. ~ 1/500sec. for flash light
After the display of 1/8000sec. the cine scale is indicated (8, 16, 24, 32, 64 and 128fps.). In this case the symbol C is displayed (Fig. 11).
The set value of shutter speed (including dine scale) is memorized even if the
13
14
Wireless (cordless) Measurement using
Electronic Flash Unit
without connecting the cord.
Meter for Operation”.
(Fig. 15).
the display off.
15
6. Display lighting
DIGI MASTER is equipped with a back­ground illumination for LCD. Electro luminescence ''ECLAT" illuminates the LCD while the display-light key (D.L.) is depressed (Fig. 12).
7. Running-lock for continuous reading
The measuring switch can be locked for continuous reading for ambient light.
(1) Switch the meter ON. (2) Rotate the switch knob clockwise until the slit on the knob matches to the white dot while depressing the knob. (3) Release the locking function after the reading is over. While the measuring switch is locked, auto shut-off function does not work.
<NOTE>
• Running-lock is only usable for ambient light measurement, not for flash light.
In case the photographing subject is too far to use synchro cord, or in case the synchro cord disturbs photographing, flash light can be measured
(2) Set the film speed (ISO) and
shutter speed (T) as shown in the paragraphs for “Preparing the
(4) While the symbol is flashing (for
about 90sec.), fire the flash unit by pressing its test button.
(5) The appropriate F-stop value is
displayed on the meter. The measured value is indicated in dual display by F-stop number with bar symbols and bar-dot symbol marks
• The display continues to indicate the measured value for about 5 minutes after measurement unless the following measurement is made. After this period of time the auto shut-off circuit operates and turns
Wire
d Measurement using Flash Unit
with Synchro Cord
or in high ambient condition, and so forth.
measurement.
16
Electronic Flash Unit
measurements for flash light.
the current reading.
measurement mode.
17
Wired measurement is recommendable when you measure the flash light from the subject position, or when the meter fails to register flash light in wireless (cordless) measurement; for example, close to a fluorescent lamp,
(2) Set the film speed (ISO) and shutter
speed (T) as shown in the paragraphs for “Preparing the Meter for Operation”.
(3) Connect the synchro cord to the
synchro terminal of meter and the flash unit.
(4) Point the Lumisphare accurately
toward the camera from the subject position, and press the measuring switch to fire the flash.
(5) The appropriate F-stop value is
displayed on the meter (Fig. 18). For repeat measurement, press the measuring switch again.
Cumulative Measurement using
When you are unable to obtain sufficient illumination with a single flash or you try for special effects using a multiple exposure technique, there may be cases that you wish to use your flash repeatedly. In such cases, you should set the meter to the cumulative measurement mode. Cumulative measurement is usable for both wireless (cordless) and wired
(1) Before pressing the measuring switch, set the cumulative measurement mode by pressing the multi-measurement key. The symbol of MO is indicated on the display (Fig. 19). (2) Measure the flash light as shown in the paragraphs for “Wireless (cordless) Measurement using Electronic Flash Unit” or “Wired Measurement using Flash Unit with Synchro Cord”. (3) The reading and the number of cumulative frequency are displayed automatically each time the flash is fired (Fig. 20). The maximum possible cumulative flashes is 9. If the flash is fired 10 or more times, the number of cumulative flashes is replaced by E mark (Error) and no further reading is possible (Fig. 21). (4) To repeat the cumulative measurement, press the multi measurement key once to release the current reading. And press the multi key again to prepare the fresh reading. In case of wireless (cordless) measurement, pressing the measuring switch can also release
< NOTE >
• The notes for wireless measurement are also applicable to wired
<NOTE>
• Memory display function (refer to page 20) is not usable if the meter is used in the cumulative

Ambient Light Measurement

Measuring ambient light, whether it is daylight or standard electric light, is a
fairly simple matter using either incident or reflected light method.
displayed (Fig. 24).
18
<NOTE>
selection key (Fig. 25)
key (Fig. 26)
19
(2) Set the film speed (ISO) and shutter
speed (in T-Priority mode) as shown in the paragraphs for “Preparing the Meter for Operation”. When you use the meter in F-priority mode, set the film speed (ISO) and F-stop value.
(3) Press the measuring switch. The
appropriate F-stop value (or shutter speed) is displayed on the meter (Fig. 23).
(4) If the measuring switch is kept
depressed, the display gives a continuous reading of the changes in brightness.
(5) When the measuring range is
exceeded, E.u. (underexposure) or E.o. (overexposure) mark is
• F-priority and T-priority can be converted by pressing F/T
• F and EV measurement can also be converted by pressing F/EV selection
Memory Display Function
DIGI MASTER is equipped with a memory function for measured 2 F-stop
priority mode, but not for cumulative flash measurement.
bar dot symbol (Fig. 27).
(Fig. 28).
measurement.
20
21
values. This function is usable for both wireless (cordless) and wired measurements for a single flash light as well as ambient light measurement in T-
(4) Memory mode is released by
pressing the memory-off key (Fig. 30).
(1) After measurement, press the
memory key. The measured F-stop value is memorized and displayed in
(2) The number of measurement to
be memorized is limited up to 2
(3) If you press the memory key after 2
dots have been displayed, the third dot starts flashing (Fig. 29). After 2 or 3 sec., flashing stops and the third dot is also remaining on the display. This third dot is not a display of memorized value, and will be replaced by the following

Post-Measurement Calculation

ambient light measurement.
22
priority mode.
23
(1) Post-measurement calculation by changing ISO sensitivity By changing ISO sensitivity the measured F-stop value is automatically changed to the appropriate one corresponding to the changed ISO value (Fig. 31).
This calculation is applicable to all measuring modes, both flash and
(2) Post-measurement calculation by
changing T value : By changing the set shutter speed (T) the measured F-stop value is automatically changed to the appropriate one corresponding to the changed T value (Fig. 32).
This calculation is applicable only for ambient light measurement in T-priority mode.
(3) Post-measurement calculation by
changing F-stop value : By changing the set F-stop value the measured shutter speed is automatically changed to the appropriate one corresponding to the changed F-stop value (Fig. 33).
This calculation is applicable only for ambient light measurement in F-

Contrast Metering for Lighting Balance

When calculating a desired lighting balance, DIGI MASTER can be used
position.
lighting contrast ratio (Table 1).
for this metering.

Illuminance (Lux) Measurement

the Lumidisc in ambient light measurement mode.
and select EV mode.
value using the (Table 2).
25
24
to measure the brightness of main and fill-in lightings from the subject
DIGI MASTER can be used as an expendient Lux meter when used with
(1) Mount the Lumidisc instead of
Lumisphare for usual incident light measurement.
(2) Select the measuring mode, and set
the ISO sensitivity and shutter speed (T) as shown in the paragraphs for “Preparing the Meter for Operation”.
(3) Point the center of Lumidisc
accurately toward the center of axis of the main lighting source from the subject, and measure the light according to the measuring method for the respective mode.
(4) Using the same procedure, measure
the fill-in light(s). In this case, be sure that the meter is held so that it is not influenced by the main lighting source.
(5) The F-stop difference between the
main and fill-in lighting sources is
< NOTE >
• In case of the measurement for F­stop value, memory display function (refer to page 20) is useful
Difference in Contrast ratio
exposure reading
(Table 1)
1 2 : 1
1 1/2 3 : 1
2 4 : 1 3 8 : 1 4 16 : 1 5 32 : 1
(2) Set the ISO sensitivity to ISO 100.
(3) Press the F/EV selection key (4) Hold the meter so that the Lumidisc
is parallel to the plane to be measured, and press the measuring switch.
(5) The measured EV value can be
converted to the corresponding Lux

Adjusting the Balance of Meter

While every effort has been made to ensure the most accurate standard
adjusting it to suit your preference.
photographing.
make an adjustment. 26
Care of the Meter
carton box using some shock-absorbing material at least 3cm in thickness. 27
calibrations as applied by SEKONIC for your DIGI MASTER, provision has been made for an adjustment of approximately ± 1EV by correcting the setting of the dial on the underside of the swivel head. It is recommended that you test the meter fully in actual photographic conditions before
(1) Carefully apply a screwdriver to the slot in the dial on the underside of the swivel head and turn it gently. (2) If you turn the dial clockwise, you can increase the index which reduces exposure when photographing. (3) If you turn the dial counter-clokwise, you can reduce the index which increases exposure when
< NOTE>
• Do not touch this dial unless you
DIGI MASTER is a high-precision instrument containing delicate electronic parts and components, and you are recommended to handle the meter with due care.
• Avoid dropping or shocking the meter.
• Don't store the meter in high temperature or high humidity locations.
• Keep Lumisphare and Lumidisc clean and free from scratches.
• To avoid unnecessary battery drain, keep the meter switched off unless actually in use. When not using the meter for a week or more, remove the batteries from the meter in order to prevent any internal damage arising from battery leakage. However note that the memory settings are tossed when the battery is removed.
• Operating temperature : 0°C ~ (+)40°C
• Storage temperature : (-)20°C ~ (+)60°C
In the event that servicing is required, contact your nearest service agency. When you send the meter to service agency by ordinary mail, it should be carefully packed in a

Specifications

Measuring system : Incident and reflected light type for both flash and ambient
about 190 grams (excl. batteries)
28
light Measuring range : f/1.4 ~ f/90+0.9AV / ISO 100 (for flash light) EV(-)1 ~ EV19.9 / ISO 100 (for ambient light measurement)
Repeat metering accuracy ± 0.1 EV Calibration constants : C=340 K=12.5 (for Lumidisc : C=250) Light receiving part Sensor: Silicon Photodiode
Swivel head : 270° horizontally and 90° upward rotatable Attachments : Lumisphare and Lumidisc for incident light, Reflected-light filter (acceptance angle 54°) and Viewfinder 5° (sold separately)
Display Measuring mode : Wired and wireless measurements for flash light, wired and
wireless cumulative flash measurements, ambient light measurement, cine scale and EV measurement Film speed : ISO 3 ~ 8000 at 1/3 SV unit Shutter speed : 1sec. ~ 1/500sec. for flash light 30min. ~ 1/8000sec. for ambient light cine scale : 8, 16, 18, 24, 32, 64 and 128fps. f/stop : 1.4 ~ 90+0.9AV for flash light
1.0 ~ 90+0.9AV for ambient light EV scale : (-)6 ~ 25.9 Other display : E.u. (underexposure), E.o. (overexposure) and battery check Display illumination : Electro Luminescence (“ECLAT” manufactured by Elix Co., Ltd., subsidiary of Sekonic)
Power Bourse : 2 x Standard accessories : Lumisphare, Lumidisc, Reflected-light filter, neck strap,
2 batteries and case
Dimensions and weight : 157
AA pen light battery (1.5V x 2)
x 68 x 28mm
Loading...