Description: Digital babyscale based on multi-Load-Cell technology, DMS-Low-End-module,
LCD, battery operated
Function diagram 25-01-02-560 Description LC-DMS module 30-34-00-729 a Description of faults 30-34-00-744
Service Manual Number
17-05-01-331-c
Valid as of: 06.07.2011
Calibration 30-34-00-764 a Cableplan 08-02-06-046 Spare parts 30-34-00-730 b
Manual number: 17-05-01-331-c
Brief description hardware LC DMS-module
Introduction
This compact module is designed to determine and display weights. Values are shown on a 5 digit LCD with additional fraction marks and icons. Determination of weights is based on 4 strain gauge load cell technology. Measurement of the 4 analog load cell values is done by a single discrete dual slope a/d converter in time multiplex (4 to 1). The a/d converter, the multiplexer and the display are driven by an integrated Microcontroller. The user interface contains 1 start/ stop button as well as 3 control buttons. All calibrations- and configurations data are stored in the Microcontroller EEPROM.
load cell 1
load cell 2
load cell 3
load cell 4
clock
multiplexer
a/d converter
µC
| EEPROM |
| power on reset |
voltage regulator
battery
keys
battery monitoring
Figure 1: block circuit of the DMS compact module
08.10.07 – Kn/Rei 1 / 5 30-34-00-729aE1
Brief description hardware LC DMS-module
Measurement:
measuring devices: 4 full bridge strain gauges supply voltage : 5V DC, regulated a/d conversion: dual slope conversion time: 8,32ms / load cell resolution: 0,4198µV
Every 500 ms 12 measurements per load cell are proceeded and averaged out. Each average value is weighted with the individual correction factor of the load cell. The conversion from cumulative load cell value to weight is done by using a linear function. The first stable value after power on is taken as zero point. Zero point handling during the use of the scale is done observing certain limits. If those limits are exceeded an error will be displayed on the LCD.
Display:
Display type: LCD (HTN), reflexive, duty cycle 1/4 Segments: 44 Digits: 5 Digit symbol height: 20mm icons: 10
Weight-Values are displayed on an LCD. The value range of the least significant digit is limited to 0 and 5.
Figure 2: visible segments of the LCD
Icons:
Battery pre-warning: Further operation of the scales is possible. Batteries should be exchanged as soon as possible. Continued use and discharge of the batteries will lead to the battery empty­ message “bAtt”. From this point no measure­ ments will be possible.
range 1: Measurement range 1 activated.
range 2: Measurement range 2 activated.
08.10.07 – Kn/Rei 2 / 5 30-34-00-729aE1