SCHOLTES PMG41DCDRSF,PMG42SF Service Manual

Scholtès UK
© 2010 Reg. Office: Peterborough PE2 9JB Registered in London: 106725
Service Information
38 cm
GAS HOBS
Models Comm. Covered Code
Single Ring PMG41DCDRSF 57506
2 Ring PMG42SF 5750
7
5413143 Issue 1 Oct. 2010
2 of 13
Service Manual UK English
SAFETY NOTES & GENERAL SERVICING ADVICE
1. All Gas Appliances MUST by law be installed by a competent person. Only use a Gas Safe (Corgi in Northern Ireland) Registered Engineer. Service or repairs should always be carried out by Scholtès UK Service personnel.
2. ALWAYS ISOLATE THE APPLIANCE FROM THE GAS, AND WHERE NECESSARY, ELECTRICAL SUPPLIES BEFORE COMMENCING ANY SERVICE OR REPAIR WORK.
3. Personal safety precautions MUST be taken by engineers to protect against accidents caused by sharp edges on metal or plastic parts.
4. This Publication is intended for qualified service engineers and all reasonable care has been taken to ensure that the information contained in the service instructions is correct at the time of printing. Continued development of products means that specifications and parts are subject to modification a nd the information given may not entirely correspond with your appliance.
5. Genuine Scholtès UK spares should always be used when repairing Scholtès UK products. For UK customers the fitting of non genuine spares could affect your rights under the product liability section of the Consumer Protection Act 1988.
IF YOU SUSPECT A GAS ESCAPE CARRY OUT THE FOLLOWING
1. DO turn off the gas supply immediately at the meter.
2. DO extinguish all sources of ignition.
3. DO open doors and windows to ventilate the room (s).
4. DO ensure access can be made to the premises. Where the operation of entry phones or electric security doors are evident, these MUST NOT BE USED. Access will have to be arranged by another method.
5. If you cannot IMMEDIATELY attend to the gas escape, report the escape to the gas supplier. Their telephone number can be found in the local telephone directory.
6. DO NOT smoke.
7. DO NOT turn on or off electrical light or power switches.
IF IN DOUBT, EVACUATE THE PREMISES AND IF NECESSARY ADJACENT PROPERTIES.
INDEX
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Technical Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 - 5
Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 - 9
Description of the Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Dismantling Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 - 12
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3 of 13
Service Manual UK English
INTRODUCTION OF SCHOLTÈS 38cm GAS HOBS MODELS PMG41DCDRSF & PMG42SF
The above 38 cm Domino Gas Hobs were introduced to the Scholtès range during October 2010. Model PMG41DCDRSF is a single Double Crown Wok burner gas hob, model PMG42SF is a double
burner gas hob with one Triple Crown burner. Both models have automatic ignition, cast iron pan supports and FSD fitted on each burner.
Model Comm. Code Colour
PMG41DCDRSF 57506 Stainless Steel PMG42SF 57507 Stainless Steel
TECHNICAL DATA
GENERAL
LPG Conversion Kits are available: C00090735 model PMG41, C00089138 model PMG42.
COUNTRY OF ORIGIN Italy
OVERALL DIMENSIONS
Height 54 mm - PMG41, 47 mm - PMG42 Width 380 mm Depth (front to back) 510 mm
GAS SPECIFICATIONS
Gas Connection Rp 1/2 (1/2" BSP Male) located on the left hand side of the hob when
viewed from the rear.
Supply Pressure Natural Gas Models - G20 @ 20 mbar
Propane (G31) at 37 mbar
Butane (G30) at 28-30 mbar Pressure Test Point Burner Injector Gas Rate Adjustment None Aeration Adjustment None
ELECTRICAL SPECIFICATIONS
Electrical Connection Flexible cord fitted 1.5 m.230/240V AC - 50HZ supply with only a 3 amp
fuse.
4 of 13
Service Manual UK English
BURNER INPUT RATES & INJECTOR SIZES
* At 15°C and 1013 mbar - dry gas ** Propane P.C.S. = 50.37 MJ/Kg *** Butane P.C.S. = 49.47 MJ/Kg
Natural P.C.S. = 37.78 MJ/Kg
The hob can only be installed above built-in ovens with a cooling fan ventilation system.
Table 1 Liquid gas Natural gas
BURNER
Diameter
(mm)
Thermal power
kW (H.s.*)
By-pass
1/100
(mm)
Injector
1/100
(mm)
Flow *
g/h
Injector
1/100
(mm)
Flow*
l/h
Nomin. Reduc. G30 G31 G20
D. Triple Ring 130 3.25 1.3 57 91 236 232 124 309
A. Auxiliary 55 1.00 0.4 30 50 73 71 71 95
I. Double flame DC DR (internal) 30 0.90 0.4 30 44 65 64 70 86
I. Double Flame DC DR (external) 130 4.10 1.3 57 70 298 293 110 390
Supply pressure
Nominal
Minimum
Maximum
28-30
20 35
37 25 45
20 17 25
PMG 41 DCDR ...PMG 41 DCDR ...
PMG 41 DCDR ...PMG 41 DCDR ...
PMG 41 DCDR ...
PMG 42 ...PMG 42 ...
PMG 42 ...PMG 42 ...
PMG 42 ...
II
II
I
DD
DD
D
AA
AA
A
Loading...