Instruction Bulletin
TM
SQR44101**Z Z-Wave Receptacle
FCC ID: 2AUCU-44101Z
** = color code: WH (white), LA (light almond), BK (black), GY (gray)
Retain for future use.
Features
• Duplex outlets, one outlet is always on, another outlet is Z-Wave controlled.
• Wireless Z-Wave technology creates a mesh network for command and
control interoperability with other Z-Wave compliant controllers and devices.
• Manual and remote ON/OFF control of any lighting or other electrical load
connected to Z-Wave controlled outlet.
• Tamper-Resistant.
• Measure the energy usage of the connected loading on the Z-Wave controlled
outlet, display the actual consumption (in W) and the accumulated power used
(in kWh) in the user interface of the gateway.
NOTE:
• Please refer to the gateway installation manual for energy usage display
and energy measurement features.
SQR44101**Z Z-Wave TR Receptacle, Energy Monitoring, 15A 125VAC Specifications
GDE77981_Eng, 06/2020
Voltage 125 Vac, 60 Hz
Regular
outlet
Controlled
Outlet
Operating temperature 32–104°F (0–40°C)
Supply connection
Wireless type Z-Wave (Support S2 and SmartStart)
Wireless frequency 908.40 MHz / 908.42 MHz / 916 MHz
1
Suitable for at least 90°C.
Current 15A
Incandescent 600 W
LED 1.25 A (150W)
Standard Ballast 1200VA
Resistive 1800W (15A)
Motor ½ Hp
14 AWG
1
____________________________________________________________________________________________
© 2020 Schneider Electric All Rights Reserved
SQR44101**Z Z-Wave Receptacle Instruction Bulletin
2 © 2020 Schneider Electric All Rights Reserved GDE77981_Eng
Precautions
HAZARD OF UNINTENDED USE
This Z-Wave receptacle is intended to be used for non-critical automation
activities. It is not intended to support life, safety, or medical equipment.
Failure to follow these instructions can result in personal injury or
equipment damage.
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
• Apply appropriate personal protective equipment (PPE) and follow safe
electrical work practices. See NFPA 70E, NOM-029-STPS or CSA Z462 or
local equivalent.
• This equipment must only be installed and serviced by qualified electrical
personnel.
• Turn off all power supplying this equipment before working on or inside
equipment.
• Always use a properly rated voltage sensing device to confirm power is off.
• To reduce the risk of overheating and possible equipment damage, do not
install to control a receptacle, a motor-operated appliance, a fluorescent
lighting fixture, or a transformer-supplied appliance.
• Use with copper wire only.
• Indoor use only.
• Replace all devices, doors, and covers before turning on power to this
equipment.
Failure to follow these instructions will result in death or serious injury.
HAZARD OF HEAT AND FIRE DAMAGE
Read all instructions before installation. The manufacturer will not be held
responsible for product damage resulting from not following the instructions.
• Wet hands are strictly prohibited.
• Work strictly according to the rated load.
• Do not continue working after self-disassembly of any nature and damage of
external forces.
Failure to follow these instructions can result in death, injury or
equipment damage.
WARNING: This product can expose you to chemicals including Carbon black, which is
known to the State of California to cause cancer, and Bisphenol A (BPA), which is
known to the State of California to cause birth defects or other reproductive harm. For
more information go to www.P65Warnings.ca.gov.
Instruction Bulletin SQR44101**Z Z-Wave Receptacle
GDE77981_Eng © 2020 Schneider Electric All Rights Reserved 3
Installation
1. Turn the power OFF at circuit breaker or fuse and test that power is off before
wiring.
2. Wire the receptacle according to the wiring diagram.
3. Check that all connections are tight and no bare wires exposed.
4. Install the receptacle into the standard outlet box using the screws provided.
5. Install the plate (not included).
6. Restore power.
Operation
1. Local control:
Press the program button, the appliance or device plugged into Z-Wave controlled
outlet will turn ON or OFF.
NOTE: After a power failure, the Z-Wave controlled outlet returns to the off state.