Schneider Electric 788 Power Relays Catalog Page

1.97 (50)
0.2
(6.1)
1.37
(34.9)
1.4
(35.4)
2.1
(53.1)
1.37
(34.9)
1.4
(35.4)
B
A
A1
A2
7
11
34
5
32
2
IEC
NEMA
1.97 (50)
0.2
(6.1)
1.37
(34.9)
1.4
(35.4)
2.1
(53.1)
1.37
(34.9)
1.4
(35.4)
U
L
US
C
Magnecraft Solution Guide 105A
788 Power Relays/SPDT, 16 Amp Rating (DC & AC)
SECTION 1
UL Listed When Used
With Magnecraft
Sockets.
Push-To-Test Button
Removable Lock-Down Door
UL Recognized File No. E43641
Finger Grip Cover
Contact Viewing Window
Gold Flashed Contacts
General Specifications (UL 508)
Contact Characteristics
Number and type of Contacts Contact materials Thermal (Carrying) Current Maximum Switching Voltage Switching Current @ Voltage
Minimum Switching Requirement
Coil Characteristics
Voltage Range
Operating Range
Average consumption
Drop-out voltage threshold
Performance Characteristics
Electrical Life (UL508) Mechanical Life Operating time (response time) Dielectric strength
% of Nominal
Operations @ Rated Current Unpowered
Between coil and contact Between poles Between contacts
Flag indicator
LED Status Lamp
Removable I.D. Tag
~
Resistive
~
Resistive Resistive
Pilot Duty
~ ~ ~ ~
(Resistive)
~ ~ ~
Units
A V
HP HP
mA
V V
VA W
ms Vrms Vrms Vrms
788XAX
Standard
SPDT
Silver Alloy
16
300 16A @ 277V 50/60Hz 16A @ 120V 50/60Hz
16A @ 28V
1/3 @ 120VAC
1/2 @ 240 VAC
B300
100 @ 5VDC (.5W)
6....240, 50/60 Hz
6....125
85% to 110% 80% to 110%
3
1.4 15% 10%
100,000
5,000,000
20 1500 1500 1500
Environment
Product certifications Ambient air temperature around the device Vibration resistance Shock resistance Degree of protection Weight
Wiring Diagram
Bottom View
1/30
788XAX
Standard version Storage Operation Operational
°C °C
g-n
UL, CSA, CE
-40...+85
-40...+55
3, 10 - 55 Hz
g-n
grams
Full Featured Dimensions Plain Cover Dimensions
10 IP 40
88
Magnecraft Solution Guide 105A
A2
A1
7
2
INPUT
12
1
14
4
11
7
22
3
32
2
21
24
9
34
5
6
31
8
12
1
14
4
11
7
22
3
32
2
21
24
9
34
5
6
31
8
A2
B
A1
A
Coil Jumper
Buss
B
A
9
8
7
6
5
4
1
2
3
INPUT
MODULE
INPUT
COM
N.O.
N.C.
(36)
1.4
(96)
(75)
(63)
(92)
(96)
2.48
3.62
3.7
2.95
3.77
0.2
(6.1)
4.09
(104)
NEMA:
IEC:
IEC
NEMA
INPUTINPUT
Standard Part Numbers
Nominal Voltage
AC Operated
6 VAC 50/60 Hz 12 VAC 50/60 Hz 24 VAC 50/60 Hz
120 VAC 50/60 Hz
220-240 VAC 50/60 Hz
Full Featured Plain Cover
Coil Resistance
4.2 Ohms 18 Ohms 72 Ohms
1700 Ohms 7200 Ohms
SPDT Part Number
(Full Feature) 16 Amp
788XAXM4L-6A 788XAXM4L-12A 788XAXM4L-24A
788XAXM4L-120A
788XAXM4L-220/240A
SPDT Part Number
(Plain Cover) 16 Amp
788XAXC-6A 788XAXC-12A 788XAXC-24A
788XAXC-120A
788XAXC-220/240A
SECTION 1
DC Operated
6 VDC 12 VDC 24 VDC 48 VDC
110-125 VDC
Custom Relay Part Number Builder
788
Series
788
XAX
Contact Config.
XAX = SPDT
16 Amp Silver Alloy = No Code
16-1351 Metal Hold-Down Clip
Section 3, p.8-11
Contact Code
70-788EL11-1
SOCKET
32 Ohms 120 Ohms 470 Ohms
1800 Ohms
10000 Ohms
788XAXM4L-6D 788XAXM4L-12D 788XAXM4L-24D 788XAXM4L-48D
788XAXM4L-110/125D
C
Cover Options
Full Feature = No Code
Plain Cover = C
Plug In = No Code
T
Terminal Style
PC terminal = T
788XAXC-6D 788XAXC-12D 788XAXC-24D 788XAXC-48D
788XAXC-110/125D
ML-
Feature Options
Side Push Button = M
Locking Push Button = M4
Bi-Polar LED = L
240A
Coil Voltage
VAC = 6 - 240A VDC = 6 - 125D
Magnecraft Solution Guide 105A
1/31
1.97 (50)
1.37
(34.9)
1.4
(35.4)
1.97 (50)
0.2
(6.1)
1.37
(34.9)
1.4
(35.4)
2.1
(53.1)
1.37
(34.9)
1.4
(35.4)
U
L
US
C
Magnecraft Solution Guide 105A
788 Power Relays/SPDT or DPDT, 16 Amp Rating (DC & AC)
SECTION 1
UL Listed When Used
With Magnecraft
Sockets.
Push-To-Test Button
Removable Lock-Down Door
UL Recognized File No. E43641
Finger Grip Cover
Contact Viewing Window
Gold Flashed Contacts
General Specifications (UL 508)
Contact Characteristics
Number and type of Contacts Contact materials Thermal (Carrying) Current Maximum Switching Voltage Switching Current @ Voltage
Current rating with magnetic blowout-
*(Optional for XBX, Standard for HXX & XHX)
Minimum Switching Requirement
Flag indicator
LED Status Lamp
Removable I.D. Tag
Blowout Magnet available for DC switching-
Standard for HXX & XHX)
Units
A V
~
Resistive
~
Resistive Resistive
HP HP
Pilot Duty
A
mA
(Optional for XBX,
788XBX
Standard
DPDT
Silver Alloy
16
300 16A @ 277V 50/60Hz 16A @ 120V 50/60Hz
16A @ 28V
1/3 @ 120VAC
1/2 @ 240 VAC
B300
3 @ 150VDC*
100 @ 5VDC (.5W)
788HXX69, 788XHX69
Standard
SPST-NO-DM, SPDT-DM-DB
Silver Alloy
16
300 16A @ 277V 50/60Hz 16A @ 120V 50/60Hz
16A @ 28V
1/3 @ 120VAC
1/2 @ 240 VAC
B300
10 @ 150VDC*
100 @ 5VDC (.5W)
Coil Characteristics
Voltage Range
Operating Range
Average consumption
Drop-out voltage threshold
Performance Characteristics
Electrical Life (UL508) Mechanical Life Operating time (response time) Dielectric strength
Environment
Product certifications Ambient air temperature around the device Vibration resistance Shock resistance Degree of protection Weight
Full Featured Dimensions Plain Cover Dimensions
% of Nominal
Operations @ Rated Current Unpowered
Between coil and contact Between poles Between contacts
Standard version Storage Operation Operational
~ ~ ~ ~
~ ~ ~
V V
VA W
(Resistive)
ms Vrms Vrms Vrms
°C
°C
g-n g-n
grams
6....240, 50/60 Hz
6....125
85% to 110% 80% to 110%
3
1.4 15% 10%
100,000
5,000,000
20 1500 1500 1500
UL, CSA, CE
-40...+85
-40...+55
3, 10 - 55 Hz
10 IP 40
88
6....240, 50/60 Hz
6....125
85% to 110% 80% to 110%
3
1.4 15% 10%
100,000
5,000,000
20 1500 1500 1500
UL, CSA, CE
-40...+85
-40...+55
3, 10 - 55 Hz
10 IP 40
88
1/32
Magnecraft Solution Guide 105A
Loading...
+ 7 hidden pages