Schneider Electric 380 V, 400 V, 415 V, 440 V Technical Specifications

Galaxy VX
380 V, 400 V, 415 V, and 440 V UPS System
Technical Specifications
07/2020
www.schneider-electric.com
Legal Information
The Schneider Electric brand and any trademarks of Schneider Electric SE and its subsidiaries referred to in this guide are the property of Schneider Electric SE or its subsidiaries. All other brands may be trademarks of their respective owners.
This guide and its content are protected under applicable copyright laws and furnished for informational use only. No part of this guide may be reproduced or transmitted in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise), for any purpose, without the prior written permission of Schneider Electric.
Schneider Electric does not grant any right or license for commercial use of the guide or its content, except for a non-exclusive and personal license to consult it on an "as is" basis. Schneider Electric products and equipment should be installed, operated, serviced, and maintained only by qualified personnel.
As standards, specifications, and designs change from time to time, information contained in this guide may be subject to change without notice.
To the extent permitted by applicable law, no responsibility or liability is assumed by Schneider Electric and its subsidiaries for any errors or omissions in the informational content of this material or consequences arising out of or resulting from the use of the information contained herein.
Go to: https://www.productinfo.schneider-electric.com/galaxyvx_iec/ or scan the QR code above for digital experience and translated manuals.
Table of Contents
Important Safety Instructions — SAVE THESE
380 V, 400 V, 415 V, and 440 V UPS System
INSTRUCTIONS
Electromagnetic Compatibility .....................................................................6
Safety Precautions .....................................................................................6
.........................................................................................5
Technical Data.............................................................................................8
System Overview .......................................................................................8
Model List ..................................................................................................9
Overview of Configurations .......................................................................10
Overview of UPSs with 1250 kW I/O Cabinet - Single Utility/
Mains................................................................................................. 10
Overview of UPSs with 1250 kW I/O Cabinet - Dual Utility/Mains ............ 11
Overview of UPSs with 1500 kW I/O Cabinet – Single Utility/
Mains................................................................................................. 11
Overview of UPSs with 1500 kW I/O Cabinet – Dual Utility/Mains ...........12
Input Power Factor ...................................................................................12
Input Voltage Window ...............................................................................13
Inverter Short-Circuit Capabilities (Bypass not Available)............................. 15
Efficiency for UPSs with 1250 kW I/O Cabinet.............................................16
Efficiency for UPSs with 1500 kW I/O Cabinet.............................................18
Derating Due to Load Power Factor ........................................................... 20
Batteries .................................................................................................. 21
Battery Runtimes for Li-Ion Battery Cabinets LIBATTSMGGIEC .............21
End of Discharge Voltage .................................................................... 23
Battery Voltage Range ........................................................................ 23
Compliance.............................................................................................. 24
Communication and Management .............................................................24
EPO Connections ............................................................................... 24
Overview of Input Contacts and Output Relays...................................... 25
Facility Planning ........................................................................................ 27
Specifications for 500 kW UPS ..................................................................27
Specifications for 625 kW UPS ..................................................................29
Specifications for 750 kW UPS ..................................................................31
Specifications for 800 kW UPS ..................................................................33
Specifications for 1000 kW UPS ................................................................ 35
Specifications for 1100 kW UPS................................................................. 37
Specifications for 1250 kW UPS ................................................................ 39
Specifications for 1500 kW UPS ................................................................ 41
Recommended Upstream Protection and Cable Sizes – IEC........................42
Weights and Dimensions........................................................................... 45
Weights and Dimensions for UPSs with 1250 kW I/O Cabinet................. 45
Weights and Dimensions for UPSs with 1500 kW I/O Cabinet................. 46
Clearance ................................................................................................ 46
Clearance for UPSs with 1250 kW I/O Cabinet ...................................... 46
Clearance for UPSs with 1500 kW I/O Cabinet ...................................... 46
Guidance for Organizing Battery Cables.....................................................47
Torque Specifications................................................................................47
Environment............................................................................................. 48
990-5850F-001 3
380 V, 400 V, 415 V, and 440 V UPS System
Heat Dissipation (BTU/hr) for UPSs with 1250 kW I/O Cabinet ..................... 48
Heat Dissipation (BTU/hr) for UPSs with 1500 kW I/O Cabinet ..................... 51
Options .......................................................................................................53
Hardware Options.....................................................................................53
Configuration Options ............................................................................... 53
Limited Factory Warranty......................................................................... 54
4 990-5850F-001
Important Safety Instructions — SAVE THESE INSTRUCTIONS 380 V, 400 V, 415 V, and 440 V UPS System

Important Safety Instructions — SAVE THESE INSTRUCTIONS

Read these instructions carefully and look at the equipment to become familiar with it before trying to install, operate, service or maintain it. The following safety messages may appear throughout this manual or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure.
The addition of this symbol to a “Danger” or “Warning” safety message indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages with this symbol to avoid possible injury or death.
DANGER
DANGER indicates a hazardous situation which, if not avoided, will result in
death or serious injury.
Failure to follow these instructions will result in death or serious injury.
WARNING
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided, could result in
minor or moderate injury.
Failure to follow these instructions can result in injury or equipment damage.
NOTICE
NOTICE is used to address practices not related to physical injury. The safety alert symbol shall not be used with this type of safety message.
Failure to follow these instructions can result in equipment damage.
Please Note
Electrical equipment should only be installed, operated, serviced, and maintained by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material.
A qualified person is one who has skills and knowledge related to the construction, installation, and operation of electrical equipment and has received safety training to recognize and avoid the hazards involved.
990-5850F-001 5
380 V, 400 V, 415 V, and 440 V UPS System

Electromagnetic Compatibility

RISK OF ELECTROMAGNETIC DISTURBANCE
This is a product Category C3 according to IEC 62040-2. This is a product for commercial and industrial applications in the second environment - installation restrictions or additional measures may be needed to prevent disturbances. The second environment includes all commercial, light industry, and industrial locations other than residential, commercial, and light industrial premises directly connected without intermediate transformer to a public low-voltage mains supply. The installation and cabling must follow the electromagnetic compatibility rules, e.g.:
the segregation of cables,
the use of shielded or special cables when relevant,
the use of grounded metallic cable tray and supports.
Failure to follow these instructions can result in equipment damage.
Important Safety Instructions — SAVE THESE
INSTRUCTIONS
NOTICE

Safety Precautions

DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
The product must be installed according to the specifications and requirements as defined by Schneider Electric. It concerns in particular the external and internal protections (upstream circuit breakers, battery circuit breakers, cabling, etc.) and environmental requirements. No responsibility is assumed by Schneider Electric if these requirements are not respected.
After the UPS system has been electrically wired, do not start up the system. Start-up must only be performed by Schneider Electric.
Failure to follow these instructions will result in death or serious injury.
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
The UPS System must be installed according to local and national regulations. Install the UPS according to:
IEC 60364 (including 60364–4–41- protection against electric shock, 60364– 4–42 - protection against thermal effect, and 60364–4–43 - protection against overcurrent), or
NEC NFPA 70
depending on which one of the standards apply in your local area.
Failure to follow these instructions will result in death or serious injury.
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
Install the UPS system in a temperature controlled area free of conductive contaminants and humidity.
Install the UPS system on a non-inflammable, level, and solid surface (e.g. concrete) that can support the weight of the system.
Failure to follow these instructions will result in death or serious injury.
6 990-5850F-001
Important Safety Instructions — SAVE THESE INSTRUCTIONS 380 V, 400 V, 415 V, and 440 V UPS System
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
The UPS is not designed for and must therefore not be installed in the following unusual operating environments:
Damaging fumes
Explosive mixtures of dust or gases, corrosive gases, or conductive or radiant heat from other sources
Moisture, abrasive dust, steam or in an excessively damp environment
Fungus, insects, vermin
Salt-laden air or contaminated cooling refrigerant
Pollution degree higher than 2 according to IEC 60664-1
Exposure to abnormal vibrations, shocks, and tilting
Exposure to direct sunlight, heat sources, or strong electromagnetic fields
Failure to follow these instructions will result in death or serious injury.
NOTICE
RISK OF OVERHEATING
Respect the clearance requirements around the UPS system and do not cover the product’s ventilation openings when the UPS system is in operation.
Failure to follow these instructions can result in equipment damage.
NOTICE
RISK OF EQUIPMENT DAMAGE
Do not connect the UPS output to regenerative load systems including photovoltaic systems and speed drives.
Failure to follow these instructions can result in equipment damage.
990-5850F-001 7
380 V, 400 V, 415 V, and 440 V UPS System Technical Data

Technical Data

System Overview

Each Galaxy VX UPS consists of the following components:
An I/O cabinet for wield wiring containing the static switch, a backfeed protection switch, and the user interface.
A number of 250 kW power cabinets containing the power electronics.
UPSs with 1250 kW I/O Cabinet
The 1250 kW I/O cabinet is used for UPS systems from a minimum configuration of 500 kW with two power cabinets to a maximum configuration of 1250 kW N+1 with six power cabinets. The I/O cabinet is placed to the left and two to six power cabinets (depending on system size) are placed to the right. The image below shows the maximum configuration.
UPSs with 1500 kW I/O Cabinet
The 1500 kW I/O cabinet is used for UPS systems from a minimum configuration of 500 kW with two power cabinets to a maximum configuration of 1500 kW N+1 with seven power cabinets. The image below shows the maximum configuration.
8 990-5850F-001
Technical Data 380 V, 400 V, 415 V, and 440 V UPS System

Model List

UPSs with 1250 kW I/O Cabinet
GVX500K500NHS: Galaxy VX 500 kW, 400 V, start-up 5x8
GVX500K750NHS: Galaxy VX 500 kW scalable to 750 kW 400 V, start-up 5x8
GVX500K1000NHS: Galaxy VX 500 kW scalable to 1000 kW 400 V, start-up 5x8
GVX500K1250NHS: Galaxy VX 500 kW scalable to 1250 kW 400 V, start-up 5x8
GVX625K625NHS: Galaxy VX 625 kW, 400 V, start-up 5x8
GVX625K1000NHS: Galaxy VX 625 kW scalable to 1000 kW 400 V, start-up 5x8
GVX750K500NHS: Galaxy VX 500 kW N+1 redundant UPS 400 V, start-up 5x8
GVX750K750NHS: Galaxy VX 750 kW, 400V, start-up 5x8
GVX750K1000NHS: Galaxy VX 750 kW scalable to 1000 kW 400 V, start-up 5x8
GVX750K1250NHS: Galaxy VX 750 kW scalable to 1250 kW 400 V, start-up 5x8
GVX800K800NHS: Galaxy VX 800 kW, 400 V, start-up 5x8
GVX1000K750NHS: Galaxy VX 750 kW N+1 redundant UPS 400 V, start-up 5x8
GVX1000K1000NHS: Galaxy VX 1000 kW, 400 V, start-up 5x8
GVX1000K1250NHS: Galaxy VX 1000 kW scalable to 1250 kW 400 V, start­up 5x8
GVX1100K1100NHS: Galaxy VX 1100 kW, 400 V, start-up 5x8
GVX1250K1000NHS: Galaxy VX 1000 kW N+1 Redundant UPS 400 V, Start­up 5x8
GVX1250K1250NHS: Galaxy VX 1250 kW, 400 V, Start-up 5x8
GVX1500K1100NHS: Galaxy VX 1100 kW N+1 Redundant UPS 400 V, Start up 5x8
GVX1500K1250NHS: Galaxy VX 1250 kW N+1 Redundant UPS 400 V, Start­up 5x8
UPSs with 1500 kW I/O Cabinet
GVX500K1500HS: Galaxy VX 500 kW 400 V scalable to 1500 kW, start-up 5x8
GVX750K1500HS: Galaxy VX 750 kW 400 V scalable to 1500 kW, start-up 5x8
GVX1000K1500HS: Galaxy VX 1000 kW 400 V scalable to 1500 kW, start-up 5x8
GVX1250K1500HS: Galaxy VX 1250 kW 400 V scalable to 1500 kW, start-up 5x8
GVX1500K1500HS: Galaxy VX 1500 kW 400 V, start-up 5x8
GVX1750K1500HS: Galaxy VX 1500 kW 400 V N+1 redundant UPS, start-up 5x8
990-5850F-001 9
380 V, 400 V, 415 V, and 440 V UPS System Technical Data

Overview of Configurations

Breakers in the System
UIB Unit input breaker
SSIB Static switch input breaker
BB Battery breaker
MBB Maintenance bypass breaker
UOB Unit output breaker
BF2 Backfeed protection switch

Overview of UPSs with 1250 kW I/O Cabinet - Single Utility/Mains

The illustration shows a 750 kW UPS. The principle is the same for the other UPSs with the 1250 kW I/O cabinet.
10 990-5850F-001
Technical Data 380 V, 400 V, 415 V, and 440 V UPS System

Overview of UPSs with 1250 kW I/O Cabinet - Dual Utility/Mains

The illustration shows a 750 kW UPS. The principle is the same for the other UPSs with the 1250 kW I/O cabinet.

Overview of UPSs with 1500 kW I/O Cabinet – Single Utility/Mains

The illustration shows a 1500 kW UPS. The principle is the same for the other UPSs with the 1500 kW I/O cabinet.
Galaxy VX 1500 kW UPS
990-5850F-001 11
380 V, 400 V, 415 V, and 440 V UPS System Technical Data

Overview of UPSs with 1500 kW I/O Cabinet – Dual Utility/Mains

The illustration shows a 1500 kW UPS. The principle is the same for the other UPSs with the 1500 kW I/O cabinet.
Galaxy VX 1500 kW UPS

Input Power Factor

500 kW 625 kW
Voltage (V) 380 400 415 440 V 380 400 415 440 V
25% load 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98
50% load 0.99 0.99 0.99 0.99 0.99 0.99 0.99 0.99
75% load 0.99 0.99 0.99 0.99 0.99 0.99 0.99 0.99
100% load 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
750 kW 800 kW
Voltage (V) 380 400 415 440 V 380 400 415 440 V
25% load 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98
50% load 0.99 0.99 0.99 0.99 0.99 0.99 0.99 0.99
75% load 0.99 0.99 0.99 0.99 0.99 0.99 0.99 0.99
100% load 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
1000 kW 1100 kW
Voltage (V) 380 400 415 440 V 380 400 415 440 V
25% load 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98
50% load 0.99 0.99 0.99 0.99 0.99 0.99 0.99 0.99
75% load 0.99 0.99 0.99 0.99 0.99 0.99 0.99 0.99
100% load 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
12 990-5850F-001
Technical Data 380 V, 400 V, 415 V, and 440 V UPS System
1250 kW 1500 kW
Voltage (V) 380 400 415 440 V 380 400 415 440 V
25% load 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98
50% load 0.99 0.99 0.99 0.99 0.99 0.99 0.99 0.99
75% load 0.99 0.99 0.99 0.99 0.99 0.99 0.99 0.99
100% load 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00

Input Voltage Window

990-5850F-001 13
380 V, 400 V, 415 V, and 440 V UPS System Technical Data
14 990-5850F-001
Technical Data 380 V, 400 V, 415 V, and 440 V UPS System

Inverter Short-Circuit Capabilities (Bypass not Available)

IK1 – Short-Circuit between a Phase and Neutral
IK2 – Short-Circuit between Two Phases
IK3 – Short-Circuit between All Three Phases
990-5850F-001 15
380 V, 400 V, 415 V, and 440 V UPS System Technical Data

Efficiency for UPSs with 1250 kW I/O Cabinet

Efficiency for a 500 kW UPS
Normal operation
Voltage (V) 380 400 415 440 V 380 400 415 440 V
25% load 96.0% 95.2% 95.2% 95.2% 97.4% 96.2% 96.3% 96.8%
50% load 96.1% 95.7% 95.7% 95.8% 99.0% 98.7% 98.8% 98.6%
75% load 95.8% 95.6% 95.6% 95.8% 99.0% 98.8% 98.8% 98.8%
100% load 95.6% 95.5% 95.6% 95.8% 99.2% 99.0% 99.0% 99.0%
ECOnversion
Voltage (V) 380 400 415 440 V 380 400 415 440 V
25% load 99.0% 98.3% 98.4% 97.7% 96.7% 96.5% 96.6% 96.6%
50% load 98.4% 98.5% 98.1% 98.2% 96.7% 96.7% 96.5% 96.5%
75% load 99.0% 98.9% 98.9% 98.8% 94.4% 96.4% 96.3% 96.3%
100% load 99.0% 99.2% 99.2% 99.1% 96.0% 95.8% 95.5% 95.5%
ECO mode
Battery operation
Efficiency for a 625 kW UPS
Normal operation
Voltage (V) 380 400 415 440 V 380 400 415 440 V
25% load 95.1% 95.2% 95.2% 95.2% 98.0% 97.6% 97.5% 97.5%
50% load 95.7% 95.7% 95.7% 96.0% 98.9% 98.7% 98.6% 98.6%
75% load 95.6% 95.6% 95.6% 96.0% 99.0% 98.8% 98.8% 98.8%
100% load 94.9% 95.5% 95.6% 95.9% 98.9% 98.8% 98.8% 98.9%
ECO mode
ECOnversion
Voltage (V) 380 400 415 440 V 380 400 415 440 V
25% load 97.1% 97.1% 98.0% 97.6% 96.9% 96.9% 96.6% 96.6%
50% load 98.4% 98.4% 98.4% 98.4% 96.3% 96.4% 96.5% 96.5%
75% load 98.7% 98.7% 98.7% 98.7% 96.3% 96.3% 96.3% 96.3%
100% load 98.8% 98.8% 98.8% 98.9% 96.1% 96.2% 95.5% 95.5%
Battery operation
Efficiency for a 750 kW UPS
Normal operation
Voltage (V) 380 400 415 440 V 380 400 415 440 V
25% load 95.7% 95.4% 95.4% 95.4% 98.4% 98.0% 97.9% 97.9%
50% load 95.8% 95.8% 95.9% 96.0% 98.9% 98.7% 98.6% 98.6%
75% load 95.3% 95.4% 95.7% 95.9% 99.0% 98.8% 98.8% 98.8%
100% load 94.6% 94.9% 95.2% 95.5% 99.0% 98.9% 98.9% 98.9%
ECO mode
16 990-5850F-001
Technical Data 380 V, 400 V, 415 V, and 440 V UPS System
ECOnversion
Voltage (V) 380 400 415 440 V 380 400 415 440 V
25% load 97.7% 97.7% 98.6% 98.2% 96.7% 96.7% 96.6% 96.6%
50% load 98.5% 98.5% 98.5% 98.5% 96.6% 96.7% 96.6% 96.6%
75% load 98.7% 98.7% 98.7% 98.7% 96.1% 96.2% 96.2% 96.2%
100% load 98.8% 98.8% 98.8% 98.9% 95.7% 95.8% 95.8% 95.8%
Battery operation
Efficiency for a 800 kW UPS
Normal operation
Voltage (V) 380 400 415 440 V 380 400 415 440 V
25% load 95.1% 95.1% 95.2% 95.2% 97.8% 97.8% 98.7% 98.7%
50% load 95.8% 95.9% 96.0% 96.1% 98.6% 98.6% 98.9% 98.9%
75% load 95.7% 95.8% 96.0% 96.1% 98.9% 98.9% 98.9% 98.9%
100% load 95.4% 95.5% 95.8% 96.1% 98.9% 99.0% 99.0% 99.0%
ECOnversion
Voltage (V) 380 400 415 440 V 380 400 415 440 V
25% load 97.5% 97.4% 97.5% 97.5% 96.2% 96.9% 97.0% 97.0%
50% load 98.5% 98.5% 98.5% 98.5% 96.4% 96.9% 96.6% 96.6%
75% load 98.8% 98.8% 98.8% 98.8% 96.3% 96.9% 96.8% 96.8%
100% load 98.9% 98.9% 99.0% 99.1% 96.0% 96.4% 96.3% 96.3%
ECO mode
Battery operation
Efficiency for a 1000 kW UPS
Normal operation
Voltage (V) 380 400 415 440 V 380 400 415 440 V
25% load 95.9% 95.6% 95.6% 95.6% 98.6% 98.2% 98.1% 98.1%
50% load 96.0% 96.0% 96.1% 96.1% 99.1% 98.9% 98.8% 98.8%
75% load 95.5% 95.6% 95.9% 95.9% 99.2% 99.0% 99.0% 99.0%
100% load 94.8% 95.1% 95.4% 95.4% 99.2% 99.1% 99.1% 99.1%
ECOnversion
Voltage (V) 380 400 415 440 V 380 400 415 440 V
25% load 97.9% 97.9% 98.8% 98.4% 96.8% 96.8% 96.7% 96.7%
50% load 98.7% 98.7% 98.7% 98.7% 96.7% 96.8% 96.7% 96.7%
75% load 98.9% 98.9% 98.9% 98.9% 96.2% 96.3% 96.3% 96.3%
100% load 99.0% 99.0% 99.0% 99.1% 95.8% 95.9% 95.9% 95.9%
ECO mode
Battery operation
990-5850F-001 17