Sanitas MD3600 Instructions For Use Manual

MD3600
Blood pressure monitor
Instructions for use
2
Content
Please read these instructions for use carefully and keep them for later use, be sure to make them accessible to other users and observe the information they contain.
1. Getting to know your device
The upper arm blood pressure monitor is used to carry out non-invasive measurement and monitoring of the arterial blood pressure values in adults.
This allows you to quickly and easily measure your blood pressure, save the measured values and display the deve­lopment and average values of the measured values taken. You are also warned of possible existing cardiac arrhythmia. The recorded values are classified according to the WHO guidelines and evaluated graphically. Store these instructions for use for future reference and make them accessible to other users.
2. Important notes
Signs and symbols
The following symbols are used in these instructions for use, on the packaging and on the type plate for the device and the accessories:
Attention
Note Note on important information
Observe the instructions for use
ENGLISH
1. Getting to know your device
2. Important notes
3. Unit description
4. Preparing the measurement
5. Measuring blood pressure
6. Evaluating results
7. Saving, displaying and deleting measured values
8. Transferring measured values
9. Error messages/troubleshooting
10. Cleaning and storing the unit
11. Technical specifications
12. Warranty / service 1
3.
FCC statement
3
Application part, type BF
Direct current
Disposal in accordance with the Waste Electrical and Electronic Equipment EC Directive – WEEE
Manufacturer
Storage
RH <93%
-25°C
70°C
Permissible storage temperature and humidity
Oper ating
5°C
40°C
RH 15-93 %
Permissible operating temperature and humidity
Protect from moisture
SN Serial number
0123
The CE labelling certifies that the product complies with the essential requirements of Directive 93/42/EEC on medical products.
Notes on use
In order to ensure comparable values, always measure your blood pressure at the same time of day.
Before every measurement, relax for about five minutes.
If you want to perform several measurements on the same person, wait five minutes between each measurement.
Do not take a measurement within 30 minutes of eating, drinking, smoking or exercising.
Repeat the measurement if you are unsure of the meas­ured value.
The measured values taken by you are for your informa­tion only – they are no substitute for a medical examina­tion. Discuss the measured values with your doctor and never base any medical decisions on them (e.g. medi­cines and their administration).
Do not use the blood pressure monitor on newborns or patients with pre-eclampsia. We recommend consulting a doctor before using the blood pressure monitor during pregnancy.
Cardiovascular diseases may lead to incorrect measure­ments or have
a detrimental effect on measurement accu­racy. The same also applies to very low blood pressure, diabetes, circulatory disorders and arrhythmias as well as chills or shaking.
4
The blood pressure monitor must not be used in connec­tion with a high-frequency surgical unit.
Only use the device on people who have the specified upper arm measurement for the device.
Please note that when inflating, the functions of the limb in question may be impaired.
During the blood pressure measurement, the blood circu­lation must not be stopped for an unnecessarily long time. If the device malfunctions remove the cuff from the arm.
Avoid any mechanical restriction, compression or bending of the cuff line.
Do not allow sustained pressure in the cuff or frequent measurements. The resulting restriction of the blood flow may cause injury.
Make sure that the cuff is not placed on an arm in which the arteries or veins are undergoing medical treatment, e.g. intravascular access or intravascular or therapy, or an arteriovenous (AV) shunt.
Do not use the cuff on people who have undergone a mastectomy.
Do not place the cuff over wounds as this may cause fur­ther injury.
The blood pressure monitor can only be operated with batteries.
To conserve the batteries, the blood pressure monitor switches off automatically if no buttons are pressed for one minute.
The device is only intended for the purpose described in these instructions for use. The manufacturer is not liable for damage resulting from improper or careless use.
Instructions for storage and maintenance
The blood pressure monitor is made from precision and electronic components. The accuracy of the measured values and service life of the device depend on its careful handling:
– Pro
tect the device from impacts, humidity, dirt, marked
temperature fluctuations and direct sunlight.
– Do not
drop the device.
– Do
not use the device in the vicinity of strong electro­magnetic fields and keep it away from radio systems or mobile telephones.
– Only
use the cuff included with the delivery or original replacement parts. Otherwise incorrect measured values will be recorded.
Do not press the buttons before the cuff is placed on the arm.
We recommend that the batteries be removed if the de­vice will not be used for a prolonged period of time.
5
Notes on batteries
Swallowing batteries can be extremely dangerous. Keep
the batteries and products out of the reach of small children. If a battery is swallowed, seek medical attention immediately.
Batteries must not be recharged, taken apart, thrown into
an open fire or short circuited.
If the batteries are empty or you do not intend to use the
device for longer periods, remove the batteries from the device. This prevents damage which could occur due to leakage. Always replace all batteries at the same time.
Do not use different types of batteries, different brands or
batteries with different capacities.
For preference, use alkaline batteries.
Instructions for repairs and disposal
Batteries do not belong in household waste. Please dis-
pose of empty batteries at the collection points intended for this purpose.
Do not open the device. Failure to comply will result in
voiding of the warranty.
Do not repair or adjust the device yourself. Proper opera-
tion can no longer be guaranteed in this case.
Repairs must only be carried out by Customer Services
or authorised suppliers. Before making a claim, please check the batteries first and replace them if necessary.
Please dispose of the device in accordance with EC Directive – WEEE (Waste Electrical and Electronic Equipment).
If you have any questions, please contact the local
authorities responsible for waste disposal.
6
3. Unit description
1. Cuff
2. Cuff line
3. Cuff connector
4. START/STOP button
5. Function buttons -/+
6. WHO scale
7. Connection for cuff connector
8. Display
9. Memory button M
10. Setting button SET
Information on the display:
1. Time and date
2. Systolic pressure
3. Diastolic pressure
4. Calculated pulse value
5. Cardiac arrhythmia symbol
6. Battery replacement symbol
7. Memory display: average value ( ), eve-
ning (
), memory space number
8. Release air
9. WHO classification
10. User memory
11. Symbol for Bluetooth
®
transfer
M
SET
Bluetooth
®
SMART
WHO
mmHg
S YS
mmHg
DIA
/min
PUL
8 7
6
4
10
5
9
2
1
3
1
10
9
8
567
2
3
4
11
Loading...
+ 11 hidden pages