Samsung ML-5000 Specifications

Emulation PCL5e (ML-5000A), WPS (ML-5000G)
Interface (Parallel Port) Centronics IEEE- P1284 compatible bi-directional (Nibble, Byte, ECP)
Print Speed 8 PPM (A4 Size, 5 % Character Pattern)
Print Method Non-impact Electrophotography, Laser Beam
Resolution 600 X 600 DPI
Memory Standard: 4 Mb (ML-5000A) / 1 Mb (ML-5000G)
Expandable up to 36 Mb for ML-5000A only
o
C,
Humidity: 20 ~ 80 % RH
Storage Environment Temperature : -20 ~ 40 oC,
Humidity: 10 ~ 95 % RH
Weight Net : 7.5 kg (max.),
Gross : 9.5 kg (max.)
Dimension 345 (W) X 364 (D) x 224 (H) mm
Certification & Compliance CE, TUV, SEMKO, NEMKO, DEMKO, C-tick
FCC, UL, CSA, CDRH, CB, EPA
2. Specifications
2-1 General
Samsung Electronics 2-1
2-2 Samsung Electronics
Specifications
Input Voltage AC 200~240 V ± 15 %, 50/60 Hz ± 3 Hz
DC Output Voltage
Line Regulation 24 V ± 3 %
5 V ± 2 %
Load Regulation 24 V - 3 %/+10 %
5 V ± 3 %
Ripple Noise 24 V : 120 mV (Peak 400 mV)
5 V : 50 mV (Peak 100 mV)
Over Current Protect 24 V : 2.7 A ± 10 % (by C't )
5 V : 1.5 A ± 10 % (by C't )
Power Consumption Max. 450 Wh Everage: 200 Wh
Power Save Mode: 25 Wh
Warming Up Time 20 seconds or less
First Print Time Idle mode : 20 seconds or less
Power Save mode : 30 seconds or less
Acoustic Noise Standby : 36 dB or less
Sleep Mode: Background level Operating : 48 dB or less
Reliability
Insulation Resistance 10 Mohm or less (at DC 500 V) Dielectric Strength AC 1500 V (DC 2100 V), 10 mA Ground Continuous 0.1 ohm or less Voltage DIP Rated voltage ± 15 % AC Impulse Noise AC 1000 V 10, 100, 200, 400, 1000 ns Leakage Current 3.5 mA or less Surge 0.5 ~ 4 kV, 0.25 ~ 2 kA Ozone Emission 0.1 ppm or less (8 hours) Top Cover Open Isolating the input power of the LSU, high voltage part, and fuser Overcurrent Protect Fuse inside the Engine Controller
Fusing System
Trouble Sensing The temperature doesn't rise to the specific temperature within a
specific time. Fuser error occurs if the temperature is too high.
Overheat Sensing 240 ~ 250
o
C (The thermostat cuts off the Fuser from the power.)
Thermistor Open Sensing Without the initial temperature change of the Fuser
Source of Light Laser Diode (LSU)
Developer
Developing Non-magnetic contact developing Charging Conductive roller charging Density Adjustment Dark, Medium Transfer System Pre-transfer by LED & conductive roller Fusing System Temperature & Pressure Ozone Emission 0.1 PPM or less (8 hours)
2-2 Electrical