Ryobi RP4030 User Manual [en, fr, es]

OPERATOR’S MANUAL
Tek4® Lithium-ion 4V Professional Infrared Thermometer
RP4030
IMPORTANT SAFETY
INSTRUCTIONS
WARNING:
READ AND UNDERSTAND ALL INSTRUCTIONS. Failure to
follow all instructions listed below, may result in electric shock, fire and/or serious personal injury.
Use of controls or adjustments or perfor mance of pro­cedures other than those specified herein may result in hazardous radiation exposure.
The laser guide radiation used in the thermometer is
Class II with < 1mW and 630-670nm wavelengths.
Avoid direct eye exposure when using the laser and
do not project the laser beam directly into the eyes of others. Serious eye injury could result.
Do not remove or deface any prod uct labels. Remov-
ing product labels increases the risk of exposure to laser radiation.
Do not place the instrument in a position that may
cause anyone to stare into the laser beam intentionally or unintention ally. Serious eye injury could result.
Do not operate the thermometer around children or
allow children to operate the tool. Serious eye injury
could result.
Do not use for medical evaluations or to measure body
temperature. This product is meant for household use
only.
Do not use this product as a precision thermometer. Do not operate the instrument in com bustible areas
such as in the presence of flammable liquids, gasses, or dust.
Always ensure the laser beam is aimed at a surface
without reflective proper ties. Shiny reflective materials
are not suitable for laser use.
The laser shall be used and maintained in accordance
with the manufacturer’s instructions.
 Neveraimthebeamatapersonorobjectotherthan
the target surface.
This product should not be used without the battery
cap installed.
Handle the instrument with care. Treat it as you would
any other optical device such as a camera or binoculars.
Avoid exposing the instrument to shock, continuous
vibration, or extreme hot or cold temperatures. Dam-
age to the product and/or serious injury to the user could result.
Use battery only with charger listed.
MODEL BATTERY PACK CHARGER
RP4030 AP4001 AP4700, AP4500, 4800
Do not use on a ladder or unstable support. Stable
footing on a solid surface enables better control of the product in unexpected situations.
Do not use the product if the trigger does not turn it
on and off.
Use the product in accordance with these instructions
and in the manner intended for the product, taking into account the working conditions and the work to be performed. Use of the product for operations
different from those intended could result in a hazardous situation.
Recharge battery only with the charger specified by
the manufacturer. A charger that is suitable for one type
of battery pack may create a risk of fire when used with another battery pack.
Use battery products only with specifically designated
battery packs. Use of any other battery packs may create
a risk of injury and fire.
When servicing a battery product, use only identical
replacement parts. Follow instructions in the Maintenance section of this manual. Use of unauthorized
parts or failure to follow Maintenance instructions may create a risk of shock or injury.
Know your battery product. Read operator’s manual
carefully. Learn its applications and limitations, as well as the specific potential hazards related to this power tool. Following this rule will reduce the risk of electric
shock, fire, or serious injury.
Do not place battery products or their batteries near
fire or heat. This will reduce the risk of explosion and
possibly injury.
Do not crush, drop or damage battery pack. Do not
use a battery pack or charger that has been dropped or received a sharp blow. A damaged battery is subject
to explosion. Properly dispose of a dropped or damaged battery immediately.
Batteries can explode in the presence of a source
of ignition, such as a pilot light. To reduce the risk of
serious personal injury, never use any cordless product in the presence of open flame. An exploded battery can propel debris and chemicals. If exposed, flush with water immediately.
Do not charge battery tool in a damp or wet location.
Following this rule will reduce the risk of electric shock.
For best results, your battery tool should be charged
in a location where the temperature is more than 50°F but less than 94°F. To reduce the risk of serious personal
injury, do not store outside or in vehicles.
Under extreme usage or temperature conditions,
battery leakage may occur. If liquid comes in contact with your skin, wash immediately with soap and water. If liquid gets into your eyes, flush them with clean water for at least 10 minutes, then seek immediate medical attention. Following this rule will reduce the risk of serious
personal injury.
Save these instructions. Refer to them frequently and use
them to instruct others who may use this product. If you loan someone this instrument, loan them these instructions also.
SYMBOLS
The following signal words and meanings are intended to explain the levels of risk associated with the product.
SYMBOL / SIGNAL MEANING
DANGER:
WARNING:
CAUTION:
CAUTION:
Indicates an imminently hazardous situ­ation, which, if not avoided, will result in death or serious injury.
Indicates a potentially hazardous situa­tion, which, if not avoided, could result in death or serious injury.
Indicates a potentially hazardous situ­ation, which, if not avoided, may result in minor or moderate injury.
(Without Safety Alert Symbol) Indicates a situation that may result in property damage.
SYMBOLS
Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to operate the tool better and safer.
SYMBOL / NAME
Safety Alert
Read The Operator’s Manual
Volt Voltage
V
Hertz Frequency (cycles per second)
Hz
Watt Power
W
Direct Current
Laser Exposure
Recycle Symbols
Indicates a potential personal injury hazard.
To reduce the risk of injury, user must read and understand operator’s manual before using this product.
Type or a characteristic of cur­rent
Laser radiation - avoid direct eye exposure.
This product uses lithium-ion (Li­ion) batteries. Local, state or fed­eral laws may prohibit disposal of batteries in ordinary trash. Con­sult your local waste authority for information regarding available recycling and/or disposal op­tions.
DESIGNATION/
EXPLANATION
FEATURES
PRODUCT SPECIFICATIONS
Battery Pack Voltage ................................................... 4 V DC
Laser Certifications .........................
IR Display Resolution .................................................. 0.1ºC/ºF
Ambient Operating Temperature Range.............30º to 122º F
Response Time .............................................................0.5 sec
Distance to Spot Ratio .......................................................10:1
Emissivity ........................................................... Preset to 0.95
Data Memory ..........................................................10 readings
KNOW YOUR INFRARED THERMOMETER
See Figure 1, page 2. The safe use of this product requires an understanding of the
information on the product and in this operator’s manual. Before use of this product, familiarize yourself with all operating features and safety rules.
10:1 SPOT/DISTANCE RATIO
See Figure 3, page 2.
DATA MEMORY
Up to 10 temperature readings may be stored in memory.
FAHRENHEIT AND CELSIUS READINGS
Your infrared thermometer can be switched from Fº to Cº readings by pressing the ºC/Fº key. Accurately measures temperatures ranging from -4ºF to 590ºF (-20 ºC to 310 ºC).
LCD DISPLAY
The LCD display features a backlight that remains on while you are taking measurements.
LASER POINTER
The laser pointer will show you the center of the target area that is being read.
LOW BATTERY INDICATOR
The low battery indicator shows when the battery should be replaced or recharged.
PROTECTIVE COVER
The protective cover helps prevent dirt or moisture from entering the infrared receiver and laser areas, and is attached to the thermometer for convenience.
Class II<1mW, 630-670nm
ASSEMBLY
OPERATION OPERATION
UNPACKING
This product has been shipped completely assembled. Carefully remove the product and any accessories from the
box. Make sure that all items listed in the packing list are included.
WARNING:
Do not use this product if it is not completely assembled or if any parts appear to be missing or damaged. Use of a product that is not properly and completely assembled could result in serious personal injury.
Inspect the product carefully to make sure no breakage or
damage occurred during shipping.
Do not discard the packing material until you have carefully
inspected and satisfactorily operated the product.
If any parts are damaged or missing, please call
1-800-525-2579 for assistance.
PACKING LIST
Thermometer Operator’s Manual
WARNING:
If any parts are damaged or missing do not operate this product until the parts are replaced. Failure to heed this warning could result in serious personal injury.
Fig. 1
Avoid Exposure. Radiation is emitted from this aperture.
Éviter toute exposition. Le rayonnement est émis de cette ouverture.
Evite la exposición. Se emite radiación a través de esta abertura. Complies with / Convient aux pièces / Cumple con partes 21CFR parts 1040.10 & 1040.11
DANGER • DANGER • PELIGRO
LASER RADIATION : AVOID DIRECT EYE EXPOSURE RAYONNEMENT LASER : ÉVITER LE CONTACT OCULAIRE DIRECT RADIACIÓN LÁSER: EVITE LA EXPOSICIÓN DIRECTA DE LOS OJOS
MAXIMUM OUTPUT: <1 mW • WAVELENGTH : 630-670nm • CLASS II LASER PRODUCT
PUISSANCE MAX. : <1 mW • LONGUEUR D’ONDE : 630-670nm • PRODUIT LASER DE CLASSE II
POTENCIA MÁX. <1 mW • LONG. ONDA: 630-670nm • APARATO LÁSER CLASE II
RP4030
WARNING:
Do not attempt to modify this product or create accessories not recommended for use with this product. Any such alteration or modification is misuse and could result in a hazardous condition leading to possible serious personal injury.
WARNING:
Do not allow familiarity with products to make you careless. Remember that a careless fraction of a second is sufficient to inflict serious injury.
WARNING:
Always remove battery pack from the product when you are assembling parts, making adjustments, cleaning, or when not in use.
APPLICATIONS
Non-contact temperature measurement for electricians,
facility maintenance personnel and remodeling contrac­tors
Check the temperature of air vents and other HVAC ap-
plications
Check temperatures of exterior/interior surfaces Automotive applications
Fig. 2
C
B
INSTALLING/REMOVING BATTERY PACK
See Figure 2, page 2.
To install the battery pack:
Unscrew the battery compartment cap. NOTE: Do not remove the gasket inside the cap. Insert the battery pack in the direction shown. Make sure
the raised rib on the battery pack aligns with the groove in the battery compartment.
Place the cap over the battery pack and push down
until the cap meets the threads at the end of the battery compartment.
Screw the cap on securely.
To remove the battery pack:
Unscrew the cap. The battery pack will disconnect and
be easy to remove.
Do not attempt to use this product if the battery cap is not
securely closed.
TAKING TEMPERATURE READINGS
See Figure 3, page 2.
Always remove the protective cover before taking a reading. Replace the cover when you are finished taking readings or before storing the thermometer.
B
A
A - Trigger (gâchette, gatillo) B - Target measuring beam ( C - Laser aperture (ouverture laser, ouverture laser) D - Protective cover (couvercle protecteur, tapa protectora)
faisceau de mesure, rayo medidor
Fig. 3
B
4 in.
@40 in.
RELACIÓN DE DISTANCIA AL OBJETIVO (D:S)
S
100 mm
@ 1000 mm
A - Laser beam ( B - Target area (zone ciblée, área objetivo) C - Trigger (gâchette, gatillo)
faisceau laser, rayo láser
50 mm
@ 500 mm
D
)
A
)
D
DISTANCE TO SPOT RATIO (D:S)
RÉSOLUTION OPTIQUE (D:S)
2 in.
@20 in.
A
C
A - Battery compartment (compartiment
de piles, compartimiento de las baterías)
B - Battery pack (bloc-pile, paquete de
baterías)
C - Battery cap (couvercle du piles,
cubierta de baterías)
C
Fig. 4
C
B
LOG
G
HOLD
73
80
f
.9
MAX
MIN
F
C
/
F
m
i
n
/
m
a
x
E
D
H
A
A - LCD Display (afficheur ACL, pantalla de cristal líquido) B - RECORD button (bouton RECORD [(Enregistrer)], botón de Grabación) C - PLAY button (bouton Play [Lecture], botón de Reproducción ) D - Min/max button (bouton min/max [Minimum/maximum], botón min/max [mínimo/máximo]) E - ºC/ºF button (bouton ºC/ºF, botón ºC/ºF) F - HOLD indicator (icône HOLD [Retenue], ícono HOLD [retención]) G - LASER indicator (icône Laser, ícono Laser) H - LOG indicator (icône LOG [Journal], ícono LOG [registro])
2
OPERATION
For the most accurate readings, follow these hints: NOTE: Temperature readings can only be measured on a
target surface.

Place the unit less than two (2) feet from the item you wish to read.

Accuracy of readings of 50º-86ºF (10º -30ºC) is plus ( + ) or minus ( - ) 3°F (1.5°C) of the actual temperature. All other readings are +/- 1.5% of the reading.

Readings at distances greater than two (2) feet may be less accurate due to external light sources, surrounding air temperature and reading of larger surface areas not intended to be measured.

Cleaner surfaces will give more accurate readings.
To take a temperature reading:

Press and/or hold the trigger to scan the surface temperature of a target object.

The backlight and laser icon will come on.

The laser pointer indicates the center of the circular area being scanned for reference only.

The surface temperature and maximum temperature readings are displayed.

When the trigger is released, the laser will turn off. The HOLD icon will stay on.

The backlight will turn itself off after a period of no use. Press­ing any button will turn the backlight on again when the LCD is still in use.
To take a maximum/minimum reading:

Hold the trigger to scan the surface temperature of a target object.

Move the laser beam from one target point to another desired target point while holding the trigger.

Release the trigger. The maximum temperature is displayed. To display the minimum reading, press the min/max button.

If desired, record the minimum/maximum reading.
USING THE FUNCTION BUTTONS
See Figure 4, page 2.
To store a reading into memory, press the Record button
( ). The LOG icon will light up to show the reading has been logged into memory. Up to 10 readings can be recorded.
NOTE: If the memory is full, the oldest reading will be deleted
to add the new reading.
To recall a reading stored in memory, press the
( ). Pressing the button repeatedly will scroll through all 10 readings.
To clear the memory, press and hold Record and Play together
for 4 seconds.
The min/max button switches the display from the minimum
reading to the maximum reading.
To switch back and forth from Celsius to Fahrenheit, press the
ºC/Fº button. Recorded temperatures can be read as both
Celsius and Fahrenheit.
Play button
MAINTENANCE
WARNING:
Always wear eye protection with side shields marked to comply with ANSI Z87.1 during maintenance. If operation is dusty, also wear a dust mask.
WARNING:
To avoid serious personal injury, always remove the battery pack from the product when cleaning or performing any maintenance.
GENERAL MAINTENANCE
Avoid using solvents when cleaning plastic parts. Most plastics are susceptible to damage from various types of commercial solvents and may be damaged by their use. Use clean cloths to remove dirt, dust, oil, grease, etc.
WARNING:
Do not at any time let brake fluids, gasoline, petroleum-based products, penetrating oils, etc., come in contact with plastic parts. Chemicals can damage, weaken or destroy plastic which may result in serious personal injury.
MAINTENANCE
BATTERIES
This product will accept Ryobi 4 V lithium-ion batteries. Length of service from each charging will depend on the type of work you are doing. Lithium-ion batteries have been designed to provide maximum trouble-free life. However, like all batteries, they will eventually wear out. Do not disassemble battery pack and attempt to replace the batteries. Handling of these batteries, especially when wearing rings and jewelry, could result in a serious burn. To obtain the longest possible battery life, we suggest the following: Remove the battery pack from the charger once it is fully
charged and ready for use. For battery pack storage longer than 30 days: Store the battery pack where the temperature is below 80°F
and away from moisture.
Store battery packs in a 30%-50% charged condition. Every six months of storage, charge the pack as normal.
BATTERY PACK REMOVAL AND PREPARATION FOR RECYCLING
WARNING:
Upon removal, cover the battery pack’s terminals with heavy­duty adhesive tape. Do not attempt to destroy or disassemble battery pack or remove any of its components. Lithium-ion batteries must be recycled or disposed of properly. Also, never touch both terminals with metal objects and/or body parts as short circuit may result. Keep away from children. Failure to comply with these warnings could result in fire and/or serious injury.
WARRANTY
LIMITED TWO YEAR WARRANTY AND 90 DAY EXCHANGE POLICY
90-DAY EXCHANGE POLICY: During the first 90 days after date of
purchasing this product, you may either request service under this warranty or you may exchange it by returning it with proof of purchase and all original equipment packaged with the original product to the dealer from which it was purchased. The replacement product will be covered by the limited warranty for the balance of the two year period from the date of the original purchase.
LIMITED TWO YEAR WARRANTY. This product is warranted against all defects in workmanship or materials for a period of two years from the date of purchase. The warranty on any accessories for this product, excluding batteries, is limited to 90 days from the date the accessory is purchased. To obtain warranty service, call Customer Service at 1-800-525-2579 for warranty return instructions. The prod­uct must be properly packaged and returned with all equipment that was included with the original product. When you request warranty service, you must also present proof of purchase documentation, which includes the date of purchase (for example, a receipt or a bill of sale). Defective products returned within the warranty period will be repaired or replaced, at our option, free of charge, within ninety (90) days or less. The cost of shipping the product to us is your re­sponsibility. This warranty only covers defects arising under normal usage and does not cover any malfunction, failure or defects resulting from misuse, abuse, neglect, alteration, modification or unauthorized repairs. It applies only to the original purchaser at retail, and may not be transferred. One World Technologies, Inc. makes no warranties, representations or promises as to the quality or performance of this product other than those specifically stated in this warranty. Any implied warranties granted under state law, including warranties of merchantability or fitness for a particular purpose, are limited to two years from the date of purchase. One World Technologies, Inc. is not responsible for direct, indirect, or incidental damages Some states do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so the above limitations and exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
ONE WORLD TECHNOLOGIES, INC.
1428 Pearman Dairy Road, Anderson, SC 29625
Phone 1-800-525-2579
États-Unis, Téléphone 1-800-525-2579
USA, Teléfono 1-800-525-2579
www.ryobitools.com
3
Français
MANUEL D’UTILISATION
Tek4® 4V Thermomètre à infrarouges de qualité professionnelle
RP4030
INSTRUCTIONS IMPORTANTES
CONCERNANT LA SÉCURITÉ
AVERTISSEMENT :
LIRE TOUTES LES INSTRUCTIONS. Le non-respect de
toutes les instructions ci-dessous peut entraîner un choc électrique, un incendie et/ou des blessures graves.
ATTENTION :
L’usage de contrôles, de réglages ou de procédures ne figurant pas dans ce manuel peut entraîner l’exposition à des rayonnements dangereux.
Le rayonnement du guide laser utilisé sur le niveau est
de classe II, avec des longueurs d’onde de < 1mW and 630-670nm.
Éviter le contact oculaire direct avec le laser et ne pas
projeter le rayon laser dans les yeux de quiconque. Cela
pourrait causer des lésions oculaires graves.
Ne pas retirer ou altérer les autocollants apposés sur
le produit. Cela accroîtrait le risque d’exposition aux
rayonnements laser.
Ne pas placer de l’instrument à un endroit où quiconque
pourrait regarder directement dans le faisceau laser, volontairement ou accidentellement. Cela pourrait causer
des lésions oculaires graves.
Ne pas utiliser le appareil de thermomètre à proximité
d’enfants ou laisser des enfants l’utiliser. Cela pourrait
causer des lé sions oculaires graves.
 Nepasutiliserpourdesexamensmédicauxoupourprendre
la température corporelle. Ce produit est conçu pourun usage domestique seulement.
Ne pas utiliser ce produit comme thermomètre de
précision.
Ne pas utiliser de l’instrument dans des atmosphères
explosives, par exemple en présence de liquides, gaz ou poussières inflammables.
Toujours s’assurer que le faisceau laser est dirigé
vers une pièce solide, ne présentant pas de surfaces réfléchissantes. Les matériaux brillants réfléchissants ne
sont pas compatibles avec l’utilisation du laser.
Le laser coit être utilisé et entretenu conformément aux
instructions du fabricant.
 Nejamaisdirigerlefaisceaulaserversunepersonneou
un objet autre que la surface ciblée peut être lue.
Ce produit ne doit pas être utilisé sans le capuchon de
la pile.
Manipuler de l’instrument avec précaution. Le traiter
comme tout autre appareil optique, tel qu’un appareil photo ou des jumelles.
Éviter d’exposer de l’instrument à des chocs, des
vibrations continues ou des températures extrêmement basses ou élevées. Ceci pourrait causer des dommages à
l’outil et/ou des lésions oculaires graves.
Ne recharger qu’avec l’appareil indiqué.
MODÈLE PILE CHARGEUR
RP4030 AP4001 AP4700, AP4500, AP4800
Ne pas utiliser produit sur une échelle ou un support
instable. Une bonne tenue et un bon équilibre permettent de
mieux contrôler produit en cas de situation imprévue.
Ne pas utiliser le produit si le commutateur ne permet pas
de le mettre en marche ou de l’arrêter.
Utiliser le produit conformément à ces instrutions pour
les applications pour lesquelles ils sont conçus, en tenant compte des conditions et du type de travail à exécuter.
L’usage d’un outil motorisé pour des applications pour lesquelles il n’est pas conçu peut être dangereux.
Ne recharger qu’avec l’appareil spécifié par le fabricant.
Un chargeur approprié pour un type de batterie peut créer un risque d’incendie s’il est utilisé avec un autre type de batterie.
Utiliser exclusivement le bloc-pile spécifiquement indiqué
pour le produit. L’usage de tout autre bloc peut créer un risque
de blessures et d’incendie.