Rothenberger RP50, RP50 INOX Instructions For Use Manual

RP50 / RP50 INOX
Bedienungsanleitung
Instructions for use
Instruction d'utilisation
Instrucciones de uso
Istruzioni d'uso
Gebruiksaanwijzing
Bruksanvisning
Användningsinstruktioner
www.rothenberger.com/manuals
6.1004
6.1010
222
Art. Nº Art. Nº Art. Nº
1 6.1305 1 16 9.8966 1 31 9.8978 2 2 9.8981 2 17 6.1300 1 32 8.8501 2 3 9.8979 4 18 9.8968 1 33 9.8980 1 4 9.8953 1 19 2.5077 1 35 9.8982 2 5 9.8958 1 20 9.8970 1 36 9.8983 4 6 9.8955 1 21 9.8971 1 37 9.8984 1 7 9.8956 1 22 9.8972 3 38 6.1315 1 8 9.8957 1 23 9.8973 6 39 9.8987 1
9 9.8959 4 24 9.9252 1 40 6.1125 1 10 9.8960 4 25 9.9254 2 41 9.8989 1 11 9.8974 1 26 9.9253 4 42 6.1301 1 12 9.8963 1 27 9.9256 2 43 9.3995 1 13 9.8964 1 28 9.9255 2 44 9.2969 1 14 9.8254 2 29 8.8633 1 45 9.8976 2 15 9.8965 2 30 9.9257 1
EXPLODED DRAWING
3
Operating instructions
Maintenance
OPEN
15 bar OK
+ 15 bar
1 2
3
4 5
CLOSE
CLOSE
CLOSE
OPEN
7
OIL
Sehr geehrter Kunde, wir gratulieren Sie, weil Sie sich für ein Rothenberger-Produkt entschieden haben. Die Prüfpumpe RP-50 wurde entwickelt und ausgelegt, um die strengsten Qualitätsansprüche zufriedenzustellen und die Betriebsanforderungen sicherzustellen.
Das Pumpendesign zählt mit einer Reihe einzigartigen Merkmalen, die den Unterschied gegenüber anderen Prüfpumpen ausmachen.
Doppelventilsystem mit Absperrung und Ablaß zur einfacheren Einstellung des Prüfdrucks.
Kombisystem aus Kugelkopf-Ventil und einteiligem Messingverschluß, womit sich die Leckgefahren minimieren lassen.
Kolben aus Polyamid, ohne Distorsion, verschleißfest Schlagfester Tank in verzinkter Stahlausführung
mit Epoxydbeschichtung Duramant ®, um die Korrosionsbeständigkeit sicherzustellen.
Manometer, mit Ihnen zur Verfügung stehenden Kalibrierungsnachweis.
1. Allgemeine Informationen 4
2. Allgemeine Sicherheit . . . 4
3. Bedienungsanweisungen . 4
4. Wartung . . . . . . . . . . . . . . . 5
5. Spezifikationen . . . . . . . . . 5
6. Bauteile der Pumpe . . . . . . 5
444
Allgemeine Informationen
1.
BEDIENUNGSANLEITUNG
INDEX
Heutzutage können Sie zur Leitung von Flüssigkeiten zahlreiche Anlagen dieser Art, gemäß der die Rohre zusammensetzende Werkstoffart und Werkstoffnatur. Diese können aus Metall: Stahl, Inoxstahl, verzinktem Stahl, Alu, Kupfer …, aus Kunststoffen: PP, PE, PB, PVC, PE-X…, sowie auch aus Materialkombinationen, wie die Multilayers sein. All diese Rohrtypen können, abhängig vom Werkstoff und von der Verbindungsart, untereinander geschweißt, geschraubt, mechanisch mit Buchsenverbindungen, geklebt ... zusammengekoppelt werden.
Unabhängig von der Verbindungsart, Werkstoff und der geleiteten Flüssigkeit hat die gesamte Anlage ihre Dichtheit sicherzustellen und muß demnach darauf geprüft werden.
Die Prüfpumpe RP-50 ist ein Präzisionswerkzeug, womit sich die Dichtheit der Anlagen überprüfen läßt. Hierzu wird Wasser oder Öl als Prüfflüssigkeiten verwendet, wobei ein maximaler Testdruck von 60 bar erreichbar ist.
B C
E
F
D
A
Halten Sie den Behälter und das Pumpensystem sauber. Das Zuleitungsrohr wird zusammen mit Filter geliefert, um das Drucksystem der Pumpe vor Verschmutzungen zu schützen. Sollte sich der Filter verstopfen, entfernen Sie den Schmutz und reinigen Sie mit Wasser.
Schmieren Sie den Kolben öfters mit wasserbeständigem Fett ein. Achten Sie besonders darauf, den Kolben nicht zu beschädigen (Pag 3.7).
Bezeichnung: Prüfpumpe RP-50 Kode: 6.1004 Abmessungen: 720x170x260 mm Gewicht: 8 kg Behälterinhalt: 12 l. Kolbeninhalt: 45 ml Ausgangsanschluß: R 1/2” Prüfflüssigkeit: W
asser, Öl Maximale Temperatur: 50º C-120ºF Maximaler Druck: 60 bar. 860 psi. 6 Mpa
Druckschlauch V1: Sperrventil. V2: Ablaßventil Sperrhaken Griff Tank
A. B. C. D. E. F.
1. Bevor Sie diese Pumpe in Betrieb setzen, sind diese Anweisungen aufmerksam durchzulesen und zu befolgen.
2.- Bevor Sie die RP-50 starten, sollten Ihnen die Position und Bedienung der Kontrollvorrichtungen bekannt sein.
3.- Die RP-50 ist für bestimmte Anwendungen konzipiert worden. Wir empfehlen ausdrücklich sie NICHT UMZUÄNDERN, sowie auch nicht für andere Zwecke einzusetzen.
4.- Für die Integrität und Lebensdauer der Dichtungssysteme ist es besonders wichtig nicht andere als die spezifizierten Prüfflüssigkeiten einzusetzen. Verwenden Sie für Prüfzwecke NIEMALS Säuren oder andere Arten korrosiver Flüssigkeiten. Verwenden Sie immer sauberes Wasser, oder ansonsten Öl, falls Sie nicht darüber verfügen.
5.- Bevor Sie die Pumpe starten, prüfen Sie ihre Bauteile auf Mängel bzw. Beschädigungen. BENUTZEN Sie sie NIEMALS, wenn der Druckschlauch oder sonstige Bauteile beschädigt bzw. gebrochen sind.
6.- Zur Wartung setzen Sie ausschließlich Originale Rothenberger-Ersatzteile ein.
1. Schließen Sie den Druckschlauch an den zu prüfenden Kreis mit dem Ventil V1 in offenem und dem Ventil V2 in geschlossenem Zustand (Pag 3.1).
2. Öffnen Sie eine oder mehrere Ablaßstellen an der Anlage. Entfernen Sie den Sperrhaken vom Griff und pumpen Sie die Flüssigkeit, bis die gesamte Luft abgelassen ist. Schließen Sie die Ablaßstellen. Zum Füllen betätigen Sie den Pumpengriff mit großen Bewegungen (Pag 3.2).
3. Pumpen Sie weiter, bis der Prüfdruck erreicht wird.
4. Schließen Sie das Ventil V1 (Pag 3.4).
5. Wird beim Pumpen der Prüfdruck überschritten, leicht V2 öffnen und Ventile bei Erreichen des gewünschten Drucks schließen (Pag 3.5).
6. Sollten keine Leckstellen vorhanden sein, dann werden auch keine Druckabfälle bei der Manometerablesung festgestellt. Zum Abschluß öffnen Sie beide Ventile V1 und V2 (Pag 3).
5
Allgemeine Sicherheit
2.
Bedienungsanweisungen
3.
Wartung
4.
BEDIENUNGSANLEITUNG
Anm.
!
Nach Erreichen des von der Anlagegröße abhängigen Drucks ist es zweckmäßig auf dessen Stabilisierung abzuwarten. Falls erforderlich, wieder nachpumpen, bis der Druck erreicht wird.
Spezifikationen
5.
Bauteile der Pumpe
5.
Dear customer, congratulations for purchasing a Rothenberger product. The testing pump RP-50 has been developed and designed to meet the highest quality standards guaranteeing most stringent operation requirements.
A number of unique design features make the pump different from other testing pumps.
Double shut-off and purge valve system, to ease test pressure adjustment.
Combined ball head and monoblock brass shut-off valve system reducing risk of leaks in the system.
Distortion proof wear resistant polyamide piston. Knock resistant weather and cold proof galvanised steel
tank protected with Duramant ® epoxy coating. Pressure gauges with readily available calibration
certificates.
At present, a great number of installations for fluid­carrying pipes can be found depending on the type and nature of the pipe materials. These can be of metal: steel,
1. General information . . . . 6
2. General safety . . . . . . . . . . 6
3. Operating instructions . . . 6
4. Maintenance . . . . . . . . . . . 7
5. Specifications . . . . . . . . . . . 7
6. Pump parts . . . . . . . . . . . . . 7
666
General information
1.
INSTRUCTIONS FOR USE
INDEX
stainless steel, galvanised steel, aluminium, copper…, plastic materials: PP, PE, PB, PVC, PE-X…, as well as composite materials such as Multi-layer. All these types of pipes can be joined as a function of the material and the nature of the joint by means of welding, threads, mechanical joints with bushings, using adhesives …
No matter the nature of the joint, the type of material and the fluid to be carried, any installation must be liquid­tight, tests being required.
Testing pump RP-50 is a precision tool for testing installation tightness using water or oil as testing liquid, a maximum testing pressure of 60 bar being possible.
B C
E
F
D
A
Keep the tank and pump system clean. The suction pipe is supplied with a filter to prevent dirt entering the pump pressure system. If the filter should clog, remove the dirt and clean it with water.
Grease the piston periodically with water repellent grease. Be extremely careful not to damage the piston (Pag 3.7).
Name: T
esting pump RP-50 Code: 6.1004 Dimensions: 720x170x260 mm Weight: 8 kg Tank volume: 12 l. Piston volume: 45 ml Outlet connection: R 1/2” Testing fluid: W
ater, oil Maximum temperature: 50º C - 120ºF Maximum pressure: 60 bar. 860 psi. 6 Mpa
Pressure hose V1: Shut-off valve. V2: Purge valve Locking hook Handle Tank
A. B. C. D. E. F.
1. Prior to starting the testing pump, please carefully read and follow these instructions.
2. The position and operation of the controls must be studied prior to RP-50 pump operation
3. The RP-50 has been designed for specific applications. We strongly recommend that it SHOULD NOT BE MODIFIED, nor used for other purposes.
4. Using only the liquids specified for the tests is utterly important for the integrity and durability of the liquid­tight systems. NO acids or other corrosive liquids may be used for the tests. Use only clean water or Oil as an alternate.
5. Check the pump for damaged or defective parts prior to pump operation. The pump MAY NOT BE USED if pressure hoses or any other parts are flawed or broken.
6. Only original Rothenberger parts may be used for maintenance
1. Connect the pressure hose to the equipment to be tested with valve V1 opened and valve V2 closed (Pag 3.1).
2. Open one or several purge points in the installation. Remove the handle-locking hook and pump liquid until all air has been purged from the installation. Close the vent points. Fill the installation operating the pump handle with ample movements (Pag 3.2).
3. Keep on pumping until the test pressure has been reached (Pag 3.3).
4. Close valve V1 (Pag 3.4).
5. If the test pressure is exceeded during the pumping operation, crack open valve V2 until the required pressure is attained. Then close all the valves (Pag 3.5).
6. If no leaks are present, no pressure drop will be detected in gauge readings. At test completion, open both valves V1 and V2 (Pag 3).
7
General safety
2.
Operating instructions
3.
Maintenance
4.
INSTRUCTIONS FOR USE
NOTE
!
After the pressure has been reached, wait for the pressure to stabilize as a function of the size of the installation. If it should be required, pump again until the pressure is reached again.
Specifications
5.
Pump parts
5.
Cher client, félicitation pour avoir choisi un produit Rothenberger. La pompe de vérification RP-50 a été conçue et développée pour satisfaire les plus hautes demandes de qualité et assurer les besoins de fonctionnement.
La conception de la pompe prévoit une série de caractéristiques uniques qui la différencie des autres pompes de vérification.
Système double clapet, de fermeture et de purge, qui facilite le réglage de la pression de testage.
Système combiné de clapet à tête sphérique et fermeture de laiton monobloc qui minimise le risque de fuites dans le système.
Piston de polyamide sans distorsion résistant à l’usure. Réservoir en acier galvanisé résistant aux chocs avec
revêtement de peinture époxy Duramant ® pour garantir sa résistance à la corrosion.
Manomètres avec certificat de calibrage à votre disposition.
1. Informations générales . . 8
2. Sécurité générale . . . . . . . 8
3. Instructions d´opération . . 8
4. Entretien . . . . . . . . . . . . . . 9
5. Spécifications . . . . . . . . . . . 9
6. Parties de la pompe . . . . . . 9
888
Informations générales
1.
INSTRUCTION D´UTILISATION
INDEX
Dans l’actualité, vous pourrez trouver un grand nombre de types d’installations pour la conduite de fluides suivant le type et la nature des matériaux qui composent les tubes. Ceux-ci peuvent être métalliques : acier, acier inoxydable, acier galvanisé, aluminium cuivre…, de matériaux plastiques : PP, PE, PB, PVC, PE-X…, ainsi que de matériaux de combinés comme les Multicouches. Tous ces types de tubes peuvent être raccordés en fonction du matériau et de la nature du raccord moyennant soudure, filetages, raccords mécaniques avec douilles, utilisation d’adhésifs…
Indépendamment de la nature du raccord, du type de matériau et du fluide conduit, toute installation doit garantir leur étanchéité, ce pourquoi ils doivent être vérifiés.
La pompe de vérification RP-50 est un outil de précision qui permet de vérifier l’étanchéité des installations en utilisant comme fluide de vérification de l’eau ou de l’huile, et qui permet d’atteindre une pression maximale de testage de 60 bar.