Summary of Changes
This publication contains the following new or updated information.
This list includes substantive updates only and is not intended to
reflect all changes.
Top icPag e
Updated voltage rating for RJ45 Gigabit Cordset, Cat 69
Ethernet Media Specifications
Introduction
As Ethernet is increasingly used in industrial control, survival of physical media in rugged or harsh environments is becoming a necessity.
The high speed of network protocol allows it to be used in applications where other networks fall short. EtherNet/IP™ uses both standard
Ethernet and TCP/IP technologies and an open application layer protocol that is called the Control and Information Protocol (CIP). This
application layer is the same as used in DeviceNet® and ControlNet® networks.
Rockwell Automation® Cat 5e Ethernet cables are designed to supply a network connection with excellent reliability in harsh surroundings.
By optimizing the balance of twisted-pair conductors inside a robust Thermoplastic Elastomer (TPE) jacket, data is protected from noise,
chemicals, and mechanical issues to M3I3C3E3 environmental protection levels. The cable is available in RJ45 patchcords for IP20
applications or in four-pin D-coded M12 patchcords for IP67 applications where high vibration, fluids, and other contaminants can threaten
the reliability of a network.
M12 D-code field attachable insulation displacement connectors (IDC) are available in both shielded and unshielded housings with male or
female connectors. Male eight-pin RJ45 connectors are available in both a crimp termination and a toolless IDC connector for custom
cabling.
Rockwell Automation M12 to RJ45 bulkhead connectors provide an elegant transition for network architecture from an IP20 setting to an IP67
environment. The adapter can be used to connect remote junction boxes or implement an On-Machine™ solution with Armor™ I/O products.
The Rockwell Automation Ethernet media portfolio provides connectivity with excellent reliability to maintain network integrity and reduces
costly downtime from troubleshooting.
2Rockwell Automation Publication 1585-TD001G-EN-P - March 2021
Cable Spools
Unshielded Twisted-pair Ethernet Cable Spool
White/Orange
Orange
White/Green
Green
Features
•4- and 8-conductor styles
•Unshielded cable types, Cat 5e
•24 AWG conductors
•Twisted pairs maintain signal balance through cable to
provide high noise immunity and return loss
•Designed to ODVA EtherNet/IP specifications and
ISO IEC 24702
•Suitable for high noise environments M
•Riser PVC cables are used for general-purpose environments
•TPE robotic cable is used for flex applications, transmissiontested to 10 million cycles
•Plenum PVC cable is used for air duct applications
•TPE cable meets channel transmission performance to
10 million flexes
3I3C3E3
Ethernet Media Specifications
Specifications
AttributesBulletin 1585
CertificationsUL Listed and CEC
Cable typeUnshielded: 2- and 4-pair, Cat 5e
MaterialConductor: Tinned copper stranded
Bend radius10 million cycles at 20 x diameter (TPE cable)
Data rateUp to 1 GB/s
Operating temperature-40…+75 °C (-40…+167 °F)
Voltage300V
Cable and Color Code
Two-pairFour- pair
White/Orange
Orange
White/Green
Blue
White/Blue
Green
White/Brown
Brown
Product Selection
Jacket
Material
Robotic TPE
PlenumUL CMP; cUL CMG; Standard TIA 568-B
Riser PVCTealUL CMR; cUL CMG; Standard TIA 568-B1585-C8PB-Sx
(1) Replace x with 100 [100 m (328 ft)], 300 [300 m (984 ft)], or 600 [600 m (1969 ft)] for standard cable lengths (example 1585-C4TB-Sx becomes 1585-C4TB-S600 for a 600 m cable).
Rockwell Automation Publication 1585-TD001G-EN-P - March 20213
Ethernet Media Specifications
Shielded Ethernet Cable Spool
White/Orange
Orange
White/Green
Blue
White/Blue
Green
White/Brown
Brown
Shielded Twisted-pair (Foil and Braided Shield)
Features
•Four- and eight-conductor styles
•Twisted-pair shielded cable types, Cat 5e
•Twisted pairs maintain signal balance through cable to
provide high noise immunity and return loss
•Designed to ODVA EtherNet/IP specifications and
ISO IEC 24702
•Suitable for high noise environments M
•Riser PVC cables used for general-purpose environments
•PUR robotic cable used for flex applications, also Halogenfree
•600V PVC cable designed to support high-voltage
applications
•600V On-Machine rated cable for use in a cable tray that is
shared with high-voltage power cables
3I3C3E3
Specifications
AttributesBulletin 1585
CertificationsUL Listed and CEC
Material
Bend radius10 million cycles at 20 x diameter (TPE cable)
Data rateUp to 1 GB/s, Cat 5e
Voltage300V
• Conductor: Tinned copper stranded
• Insulation: High-density polyethylene
Cable and Color Code
Two-pairFour- pair
White/Orange
White/Green
Orange
Green
Product Selection
Jacket
Material
Riser PVC
Robotic PUR
600V PVCFoil shield
(1) Replace x with 100 [100 m (328 ft)], 300 [300 m (984 ft)], or 600 [600 m (1969 ft)] for standard cable lengths (example 1585-C8UB-Sx becomes 1585-C8UB-S600 for a 600 m cable).
4Rockwell Automation Publication 1585-TD001G-EN-P - March 2021
Cable Type
Foil and
braided shield
No. of
Conductors
8 (four pairs)
4 (two pairs)—
8 (four pairs)
8 (four pairs)
4 (two pairs)
Jacket
Wire Size
Color
Tea l
Red
Tea l1585-C4HB-Sx
Red
[AWG]
26
22
Nominal Outer
Diameter
5.84 mm
(0.23 in.)
6.2 ± 12 mm (0.244
8.13 ± 0.38 mm
(0.32 in.)
in.)
Operating TemperatureCable Rating
UL CMR; cUL CMG; TIA-568-B1585-C8CB-Sx
-40…+75 °C
(-40…+167 °F)
-20…+80 °C
(-4…+176 °F)
C(ETL)US TYPE CMX; TIA 568-B,
Flex rated, Halogen-Free
(UL) CMX, CMR; c(UL) CMG; (UL)
PLTC or AWM 2570 80 °C 600V;
TIA-568-B
Cat. No.
1585-C4UB-Sx
1585-C8UB-Sx
1585-C8HB-Sx
1585-C8EB-Sx
1585-C4EB-Sx
(1)
600V Ethernet Cable
RJ45 Cordset—600V
Cable Spool Product Selection
Ethernet Media Specifications
Specifications
AttributesBulletin 1585
CertificationsUL and c-UL Listed
Material
Diameter8.13 ± 0.38 mm (0.32 ± 0.015 in.)
Cable rating
• Conductor: Thin copper stranded
• Insulation: Perfluoroalkoxy copolymer and polyolefin
UL, c-UL TYPE CMG; UL PLTC or UL AWM 2570 80C 600V,
TIA 568B
Jacket
Material
600V PVCFoil shield
(1) Replace x with 100 [100 m (328 ft)], 300 [300 m (984 ft)], or 600 [600 m (1969 ft)] for standard cable lengths (example 1585-C4HB-Sx becomes 1585-C4HB-S600 for a 600 m cable).
Cable Type
RJ45 Cordsets
ShieldingCable Type
8 conductor, teal 600V PVC
Foil shield
(1) Replace x with 2 [2 m (6.6 ft)], 5 [5 m (16.4 ft)], or 10 [10 m (32.8 ft)] for standard cable
lengths (example 1585J-M8EB-x becomes 585J-M8EB-10 for a 10 m cable).
(1) Replace x with 2 [2 m (6.6 ft)], 5 [5 m (16.4 ft)], or 10 [10 m (32.8 ft)] for standard cable
lengths (example 1585J-M4HBJM-x becomes 1585J-M4HBJM-10 for a 10 m cable).
Jacket
Material
Teal 600V,
PVC
Red 600V
PVC
Teal 600V,
PVC
Red 600V
PVC
Cable
Type
(UL) CMX, CMR; c(UL)
Foil
CMG; (UL) PLTC or AWM
shield
Cable Rating
2570 80 °C 600V;
TIA-568-B
(1)
Cat. No.
1585J-M8HBJM-x
1585J-M8EBJM-x
1585J-M4HBJM-x
1585J-M4EBJM-x
Insulation Diameter
[mm (in.)]
0.85…1.6 (0.033…0.063)5…9 (0.197…0.354)
Cable Diameter
[mm (in.)]
Cat. No.
1585J-M8CC-H
(1)
(1)
Rockwell Automation Publication 1585-TD001G-EN-P - March 20215
Ethernet Media Specifications
White/Orange
Orange
White/Green
Blue
White/Blue
Green
White/Brown
Brown
36.4 (1.4)
36.4 (1.4)
32 (1.25)
32 (1.25)
48.94 (1.93)
Cable and Color Code
Four -pair
Color Code
Color Code
Face View RJ45 Pinout
8-Pin
Approximate Dimensions [mm (in.)]
RH45IDC Connector
53.1 (2.09) Ref
View
Shown
with Cap
13.9
(0.55)
Ref
6.6
(0.26)
Ref
View
Shown
without Cap
11.68
(0.46)
Ref
RH45 90° Left and Right Angle Patchcord
51.2 (2.02) Ref
13.8
(0.054)
29.3 (1.15) Ref
12 87
Ref
14.2
(0.56)
Ref
PC
12 87
B
12345678
1 White/Orange
2 Orange
3 White/Green
A
4 Blue
5 White/Blue
6 Green
7 White/Brown
8 Brown
TxData +
TxData -
Recv Data +
Unused
Unused
Recv Data -
Unused
Unused
RH45 Cordset and Patchcord
6Rockwell Automation Publication 1585-TD001G-EN-P - March 2021
RJ45 Cordsets and Patchcords
Features
•Flex-rated TPE, PVC, and plenum cables for various
applications
•Teal cable jacket
•Rugged strain relief and hitch mechanism to maintain
network integrity
•Suitable environments M
3I3C3E3
Specifications
AttributesBulletin 1585J
CertificationsUL Listed
ConnectorsRJ45 Male to RJ45 Male, Cat 5e
Cable type
Enclosure type ratingIP20
Nominal outer diameter5.84 mm (0.23 in.) ±10%
Operating temperature-20…+60 °C (-4…+140 °F)
Voltage300V
• Unshielded: 4- and 8-conductor, 24 AWG, Industrial Cat 5e
• Shielded: 8-conductor, 26 AWG, Industrial Cat 5e
Color Code
Face View RJ45 Pinout
8-Pin
Color Code
Ethernet Media Specifications
A
1 White/Orange
2 Orange
3 White/Green
4 Blue
5 White/Blue
6 Green
7 White/Brown
8 Brown
12345678
8-Pin4-Pin
TxData +
TxData -
Recv Data +
Unused
Unused
Recv Data -
Unused
Unused
1 White/Orange
2 Orange
3 White/Green
4 —
5 —
6 Green
7 —
8 —
TxData +
TxData -
Recv Data +
—
—
Recv Data -
—
—
Rockwell Automation Publication 1585-TD001G-EN-P - March 20217
Ethernet Media Specifications
48.94 (1.93)
Example of Cordset
Example of Patchcord
Product Selection
(1)
Straight
Cat. No.
Right Angle to
Left Angle
Left Angle to Left
Angle
No. of
Conductors
(1) Replace y with 2 [2 m (6.6 ft)], 5 [5 m (16.4 ft)], or 10 [10 m (32.8 ft)] for standard cable lengths (example 1585J-E8PBJE-y becomes 1585J-E8PBJE-5 for a 5 m cable).
Rockwell Automation Publication 1585-TD001G-EN-P - March 20219
Ethernet Media Specifications
48.94 (1.93)
Example of Cordset
Example of Patchcord
31.70 (1.25)
Right AngleLeft Angle
RJ45 Red Cordset
Wiring
Face View RJ45 Pinout
8-Pin
Specifications
AttributesBulletin 1585J
CertificationsUL Listed
ConnectorsRJ45 Male to RJ45 Male, Cat 5e
Cable type
Enclosure type ratingIP20
Nominal outer diameter5.84 mm (0.23 in.) ±10%
Operating temperature-20…+60 °C (-4…+140 °F)
• Unshielded: 4- and 8-conductor, 24 AWG, Industrial Cat 5e
• Shielded: 8-conductor, 26 AWG, Industrial Cat 5e
Color Code
A
1 White/Orange
2 Orange
3 White/Green
4 Blue
5 White/Blue
6 Green
7 White/Brown
8 Brown
12345678
8-Pin4-Pin
TxData +
TxData -
Recv Data +
Unused
Unused
Recv Data -
Unused
Unused
1 White/Orange
2 Orange
3 White/Green
4 —
5 —
6 Green
7 —
8 —
TxData +
TxData -
Recv Data +
—
—
Recv Data -
—
—
Approximate Dimensions [mm (in.)]
Cable Spool Product Selection
Jacket
Material
600V PVCFoil shield
(1) Replace x with 100 [100 m (328 ft)], 300 [300 m (984 ft)], or 600 [600 m (1969 ft)] for standard cable lengths (example 1585-C4HB-Sx becomes 1585-C4HB-S600 for a 600 m cable).
Cable Type
No. of
Conductors
8 (four pairs)
4 (two pairs)
Jacket
Color
Wire Size
[AWG]
Tea l
Red1585-C8EB-Sx
Tea l1585-C4HB-Sx
Red1585-C4EB-Sx
22
Nominal Outer
Diameter
8.13 ± 0.38 mm
(0.32 in.)
Operating
Te mp er at u re
-20…+80 °C
(-4…+176 °F)
Cable Rating
(UL) CMX, CMR; c(UL) CMG; (UL) PLTC or
AWM 2570 80 °C 600V; TIA-568-B
Cat. No.
1585-C8HB-Sx
(1)
Patchcord Product Selection
No. of
Conductors
8
(1) Replace y with 2 [2 m (6.6 ft)], 5 [5 m (16.4 ft)], or 10 [10 m (32.8 ft)] for standard cable lengths (example 1585J-E8PBJE-y becomes 1585J-E8PBJE-5 for a 5 m cable).
10Rockwell Automation Publication 1585-TD001G-EN-P - March 2021
•Over molded housing suitable for IP67 applications and harsh
industrial environments where extreme vibration, shock,
chemicals, and temperature are found.
•Flex-rated cable (must be tied down and not flexed within
152 mm [6 in.] of the connector).
•Custom termination of single-ended cordsets with one of
several field attachable connectors.
•Designed to ODVA EtherNet/IP specifications and
ISO IEC 24702, IEC 61918.
•Twisted pairs maintain signal balance through cable to
provide high noise immunity and return loss.
•Suitable for noise environments M
3I3C3E3
.
Ethernet Media Specifications
Specifications
AttributesBulletin 1585D
Material
Enclosure type ratingIP67
Nominal outer diameter5.84 mm (0.23 in.) ±10%
Bend radius10 x cable diameter
Operating temperature-40…+75 °C (-40…+167 °F)
• Coupling nut: Nickel-plated brass
• Housing: Polyurethane (PUR)
• Contact: Gold-plated brass
Cable Style
Cable StyleCable Type
TPE, high flex,
unshielded
PUR, foil and
braided shield,
high flex,
halogen free
PVC, 600V
rated, foil shield
4 conductor,
unshielded
twisted-pair
(UTP), teal
4 conductor,
shielded
twisted-pair
(STP), teal
Wire Size
[AWG]
Cable O.D.
[mm (in.)]
245.6 (0.22)
265.84 (0.23)
228.13 (0.32)
Cable Rating
Weld splatter,
sunlight, and
oil-resistant; UL CM,
CMX; cUL CM;
TIA 568B
C(ETL)US TYPE CMX;
TIA 568B
(UL) CMX, CMR; cUL
CMG; (UL) PLTC or
AWM 2570 80C 600V;
TIA 568B
M12 Cordset Product Selection
Cable StyleFirst End ConnectorSecond End ConnectorOperating TemperatureCat. No.
TPE, high flex, unshielded
PUR, foil and braided shield,
high flex, halogen free
PVC, 600V rated, foil shield
Male M12 D-Code, straightFlying leads
-40…+75 °C
(-40…+167 °F)
-20…+80 °C
(-4…+176) °F
1585D-M4TB-2
1585D-M4UB-2
1585D-M4HB-2
Rockwell Automation Publication 1585-TD001G-EN-P - March 202111
Ethernet Media Specifications
47 (1.85)
M12 Patchcord Product Selection
Cable StyleFirst End ConnectorSecond End ConnectorOperating TemperatureCat. No.
Male M12 D-Code, straightMale M12 D-Code, straight
TPE, high flex, unshielded
PUR, foil and braided shield, high
flex, halogen free
PVC, 600V rated, foil shield
Male M12 D-Code, right angle
Male M12 D-Code, straight
Male M12 D-Code, right angle
Male M12 D-Code, straight
Male M12 D-Code, right angle
Male M12 D-Code, straight
M12 to RJ45 Patchcord Product Selection
Male M12 D-Code, right angle
Female M12 D-Code, straight
Male M12 D-Code, straight
Male M12 D-Code, right angle
Female M12 D-Code, straight
Male M12 D-Code, straight
Male M12 D-Code, right angle
Female M12 D-Code, straight
-40…+75 °C
(-40…+167 °F)
-20…+80 °C
(-4…+176 °F)
1585D-M4TBDM-2
1585D-E4TBDE-2
1585D-M4TBDE-2
1585D-M4TBDF-2
1585D-M4UBDM-2
1585D-E4UBDE-2
1585D-M4UBDE-2
1585D-M4UBDF-2
1585D-M4HBDM-2
1585D-E4HBDE-2
1585D-M4HBDE-2
1585D-M4HBDF-2
Cable StyleFirst End ConnectorSecond End ConnectorOperating Temperature
TPE, high flex, unshielded
PUR, foil and braided shield, high flex,
(1) Replace x with 1 [1 m (3.3 ft)], 2 [2 m (6.6 ft)], 5 [5 m (16.4 ft)], or 10 [10 m (32.8 ft)] for standard cable lengths (example 1585D-M4UBJM-x becomes 1585D-M4UBJM-5 for a 5 m cable).
halogen-free
PVC, 600V rated, foil shield
Male M12 D-Code, straightRJ45
-40…+75 °C
(-40…+167 °F)
-20…+80 °C
(-4…+176 °F)
1585D-M4TBJM-x
1585D-M4UBJM-x
1585D-M4HBJM-x
Cat. No.
(1)
Accessories
DescriptionChannel BandwidthCat. No.
RJ45 insulation displacement connector (IDC)Cat 6
RJ45 crimp connector with bootCat 5e
(1) Qty. = 1 piece
(2) Qty. = 50 pieces
1585J-M8CC-H
1585J-M8CC-C
(1)
(2)
Approximate Dimensions [mm (in.)]
12Rockwell Automation Publication 1585-TD001G-EN-P - March 2021
M12 Receptacle Flex-rated
4-Pin M12 D-Code Receptacle to RJ45 Patchcord
1
4
3
2
12345678
Features
•Suitable for IP67 applications and harsh industrial
environments where extreme vibration, shock, chemicals,
and temperature are found
•Flex-rated cable (cable must be tied down and not flexed
within 6 in. [152.4 mm] of the connector)
•Designed to ODVA EtherNet/IP specifications and
ISO IEC 24702, IEC 61918
•Twisted pairs maintain signal balance through cable to
provide high noise immunity and return loss
•M12 D-code receptacle is suitable for noisy environments
M
Color Code
Color
Code
A
3I3C3E3
1 White-Orange
2 White-Green
.
2
3
3 Orange
4 Green
1
4
Ethernet Media Specifications
Specifications
AttributeBulletin 1585D
Material
Cable type
Enclosure type ratingIP67
Nominal outer diameter5.84 mm (0.23 in.) ±10%
MountingFront-mount
Operating temperature-40…+75 °C (-40…+167 °F)
Cable RatingTIA 568B, flex-rated, 24 AWG, UL, c-UL
Voltage300V
Rockwell Automation Publication 1585-TD001G-EN-P - March 202113
Ethernet Media Specifications
1
4
3
2
12345678
Connector Product SelectionColor Code Pinout
First End
Connector
Second End
Connector
Cable Type
Cat. No.
(1)
Unshielded twisted-pair,
Female M12 D-Code
Receptacle, Front
Mount
RJ45
4-conductor, teal TPE,
flex rated
Foil and braided shield,
4-conductor, teal PUR,
1585D-D4TBJM-x
1585D-D4UBJM-x
flex rated, halogen-free
(1) Replace x with 1 [1 m (3.3 ft)], 2 [2 m (6.6 ft)], 5 [5 m (16.4 ft)], 10 [10 m (32.8 ft)], or 15
[15 m (49.2 ft)] for standard cable lengths (example 1585D-D4TBJM-x becomes
1585D-D4TBJM-2 for a 2 m cable).
Approximate Dimensions [mm (in.)]
39 (1.54)
19.5 (0.77)
8
2
(0.31)
12
(0.47)
Ø
(0.35)
1.5 (0.06)
20/SW18
Ø
M12
PG9
M12 x 1
7.5
(0.29)
19.5 (0.77)
28
(1.1)
G
(0.08)
2
Dia.
18 (0.71)
Ø
Face View Pinout (Female)Face View RJ45 Pinout
4-Pin
Color
Code
1 White/Orange
2 Orange
1 White/Orange
A
2 White/Green
3 Orange
4 Green
3 White/Green
4 Blue
5 White/Blue
6 Green
7 White/Brown
8 Brown
Length
(see table)
9
Ø
5.5 (0.22)
Ø
M12
PINPIN
1
2
3
4
RJ45
1
3
2
6
44.2 (1.74)
x
x
TxData +
TxData -
Recv Data +
Unused
Unused
Recv Data -
Unused
Unused
1
2
3
6
SW17
G
14Rockwell Automation Publication 1585-TD001G-EN-P - March 2021
M12 Xcode Flex-rated Gigabit
8-Pin M12 Xcode Cordset, Cat 6
1 White/Orange
2 Orange
5 White/Brown
7 White/Blue
GND
8 Blue
6 Brown
3 White/Green
4 Green
1
2
5
7
GND
8
6
3
4
Connector pin assignment
plug M12 Cat 6
pin side view
A
1
2
5
7
8
6
3
4
50 (1.97)
Example of M12 to M12 PatchcordExample of M12 to RJ45 Patchcord
Features
•Over-molded housing suitable for IP67 applications and
harsh industrial environments where extreme vibration,
shock, chemicals, and temperature are found.
•Flex-rated cable (must be tied down and not flexed within
152.4 mm [6 in.] of the connector).
•Designed to EtherNet/IP specifications and ISO IEC 11801,
IEC 61918.
•Twisted pairs maintain signal balance through cable to
provide high noise immunity and low return loss.
•Suitable for noise environments M
3I3C3E3
.
Specifications
AttributesBulletin 1585D
Material
Cable type
Nominal outer diameter5.84 mm (0.23 in.) ±10%
Bend radius10 x cable diameter
Cable rating
Enclosure type ratingIP67
Operating temperature-40…+80 °C (-40…+176 °F)
Rockwell Automation Publication 1585-TD001G-EN-P - March 202115
1 m (3.28 ft)
1585D-M8UGDM-1
Ethernet Media Specifications
4-Pin M12 D-Code Cordset
1
4
3
2
1
4
3
2
12345678
Example of Cordset
Example of M12 to M12 Patchcord
47 (1.85)
Example of M12 to RJ45 Patchcord
M12 Red
Features
•Over molded housing suitable for IP67 applications and harsh
industrial environments where extreme vibration, shock,
chemicals, and temperature are found.
•Flex-rated cable (must be tied down and not flexed within
152.4 mm [6 in.] of the connector).
•Custom termination of single-ended cordsets with one of
several field attachable connectors.
•Designed to ODVA EtherNet/IP specifications and
ISO IEC 24702, IEC 61918.
•Twisted pairs maintain signal balance through cable to
provide high noise immunity and return loss.
•Suitable for noise environments M
M12 Pinout
3I3C3E3
.
Specifications
AttributesBulletin 1585D
Material
Nominal outer diameter5.84 mm (0.23 in.) ±10%
Enclosure type ratingIP67
Bend radius10 x cable diameter
• Coupling nut: Nickel-plated brass
• Housing: Polyurethane (PUR)
• Contact: Gold-plated brass
RJ45 Pinout
Color
Code
8-Pin4-Pin
A
1 White/Orange
2 Orange
3 White/Green
4 Blue
5 White/Blue
6 Green
7 White/Brown
8 Brown
TxData +
TxData -
Recv Data +
Unused
Unused
Recv Data -
Unused
Unused
1 White/Orange
2 Orange
3 White/Green
4 —
5 —
6 Green
7 —
8 —
TxData +
TxData -
Recv Data +
—
—
Recv Data -
—
—
Color
Code
A
1 White-Orange
2 White-Green
3 Orange
4 Green
Product Selection
Cable Style
Red high flex TPE, unshielded
Red high flex PUR, foil and braided shield, high flex, halogen-free
Red 600V PVC, 600V rated, foil shield
Approximate Dimensions [mm (in.)]
First End
Connector
Male M12 D-Code, straight
Second End
Connector
Operating TemperatureCat. No.
-40…+75 °C
(-40…+167 °F)
-20…+80 °C
(-4…+176 °F)
1585D-M4VBDM-2
1585D-M4FBDM-2
1585D-M4EBDM-2
16Rockwell Automation Publication 1585-TD001G-EN-P - March 2021
RJ45 Field Attachable Connector
RJ45 Insulation Displacement Connector (IDC)
RJ45 Crimp
IDC Connector Features
•27...24 AWG (solid wire) or 27…22 AWG (stranded wire)
conductors
•360° shielding
•Reuse IDC connector up to five times
•No tools or conductor stripping required
•Cat 6
Crimp Connector Features
Ethernet Media Specifications
Specifications
AttributeBulletin 1585J
CertificationsUL Listed
Connector typeRJ45 male
Enclosure type ratingIP20
Operating temperature-40…+70 °C (-40…+158 °F)
•26…24 AWG
•Standard crimp connector with rugged boot
•Cat 5e
Rockwell Automation Publication 1585-TD001G-EN-P - March 202117
Ethernet Media Specifications
12345678
11.68 (0.46)
8.18 (0.32)
4.38 (0.17)
6.10 (0.24)
7.47
(0.29)
6.60
(0.26)
22.55 (0.89)
12.32 (0.48)
7.92
(0.31)
8.6
(0.34)
35.7
(1.4)
13.5
(0.53)
9.71
(0.38)
6.5 (0.26)
8.6
(0.64)
Product Selection
Description
RJ45 insulation displacement
connector (IDC)
RJ45 crimp connector with boot150V, 1.5 A Clear polycarbonateCat 5e
These documents contain additional information concerning related products from Rockwell Automation.
1
2
3
4
5
6
7
8
ResourceDescription
Industrial Ethernet Media Brochure, publication 1585-BR001
Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1
Provides an overview of Ethernet Media products that Rockwell Automation offers.
Provides general guidelines for installing a Rockwell Automation industrial system.
Product Certifications website, rok.auto/certifications.Provides declarations of conformity, certificates, and other certification details.
You can view or download publications at rok.auto/literature
.
Rockwell Automation Publication 1585-TD001G-EN-P - March 202121
Rockwell Automation Support
Use these resources to access support information.
Technical Support CenterFind help with how-to videos, FAQs, chat, user forums, and product notification updates. rok.auto/support
KnowledgebaseAccess Knowledgebase articles.rok.auto/knowledgebase
Local Technical Support Phone NumbersLocate the telephone number for your country.rok.auto/phonesupport
Literature LibraryFind installation instructions, manuals, brochures, and technical data publications.rok.auto/literature
Product Compatibility and Download Center
(PCDC)
Download firmware, associated files (such as AOP, EDS, and DTM), and access product
release notes.
rok.auto/pcdc
Documentation Feedback
Your comments help us serve your documentation needs better. If you have any suggestions on how to improve our content, complete the
form at rok.auto/docfeedback
.
Allen-Bradley, Armor, expanding human possibility, On-Machine, and Rockwell Automation are trademarks of Rockwell Automation, Inc.
ControlNet, DeviceNet, and EtherNet/IP is a trademark of ODVA, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec.
Rockwell Otomasyon Ticaret A.Ş. Kar Plaza İş Merkezi E Blok Kat:6 34752, İçerenköy, İstanbul, Tel: +90 (216) 5698400 EEE Yönetmeliğine Uygundur