Temperature Controller
Option Units
900-TC16NCOM
900-TC16NEIM
900-TC16NACCOM
900-TC16NACEIM
900-TC16NCOMP3
900-TCNCOMV2
900-TC16P1V
English
41063-223-01 (2)
Printed In China
For detailed operating instructions, please
refer to the 900-TC16 User's Manual.
It can be found online at:
http://www.ab.com/manuals/.
CN9
1618402-5B
Contents of box
Make sure the box contains the following items. If anything is missing or damaged, contact your dealer immediately.
• Option units
Model
900-TC16NCOM
900-TC16NEIM
900-TC16NACCOM
900-TC16NACEIM
900-TC16NCOMP3
900-TCNCOMV2
900-TC16P1V2
Communication (RS-485)
Heater burnout alarm, 1 alarm (CT)
Event inputs, 2 inputs
Heater burnout alarm, 1 alarm (CT)
Communication (RS-485)
Function
Event inputs, 2 inputs
Communication (RS-485)
Heater burnout alarms, 2 alarms (CTs)
Communication (RS-485)
Control output 2 (voltage outputs)
Control output 2 (voltage outputs)
Heater burnout alarm, 1 alarm (CT)
Handle with care. Do not touch the
electronic parts and do not jolt the
unit.
(1) Insert the tools (see drawing below) into
the slots (one at the top and one at the
bottom) and release the hooks.
(2) Grip the sides of the front panel firmly
and pull forward to remove it.
(3) Match up the upper and lower claws
with the connection points and insert the
board.
(4) Attach the terminal block included with
the Option unit to the outer case.
(5) Make sure the watertight packing is in
place, then press the outer casing into
position. Listen for the click.
• Terminal block, 1
• Terminal labels, 1 sheet
Assembling the unit
(1)
(5)
(2)
(1)
Watertight packing
(3)
(4)
Standard slot screwdriver
(unit: mm)
20 min.
2.0
0.4
Specifications Connections
Communication Interface: RS-485
Synchronization: Start-stop (asynchronous)
Communication: Half duplex
Communication rate: 1.2/2.4/4.8/9.6/19.2/38.4 kbps
Event input Contact input
ON: 1k max., OFF: 100k min.
Non-Contact input
ON: residual voltage 1.5V max.
OFF: leakage current 0.1mA max.
Heater burnout alarm Maximum heater current: 50 A AC
(Heater Short alarm)
Input current indication accuracy: ±5% FS ±1 digit
max.
Heater burnout alarm setting range: 0.1 to 49.9 A,
in 0.1 A increments
(Heater Short alarm setting range
Detection ON time (detection OFF time) : 190 ms
Note: Values in parentheses apply to the Heater Short
alarm setting.
Control output 2 Voltage output: 12 VDC, 21 mA
(with short-circuit protection circuit)
900-TC16NCOM
Communication /
CT
B
11
RS-485
A
12
DO
13
NOT
USE
14
CT1
15
Apply the adhesive terminal label of the option unit to the side of the Temperature Controller.
Use separately available CTs: 900-CT1(Hole diameter: 5.8 mm) or 900-CT3(Hole diameter: 12 mm).
• For detailed operating instructions, please refer to
the 900-TC16 User's Manual.
• For details of the communication specifications, refer to
the Bulletin 900 Communications User's manual.
900-TC16NEIM
Event input /
CT
11
12
EV1
13
EV2
14
CT1
15
900-TC16NACCOM
Communication
B
11
RS-485
A
12
DO NOT
13
USE
DO NOT
14
USE
DO NOT
15
USE
900-TC16NACEIM
Event input
11
12
EV1
13
EV2
DO NOT
14
USE
DO NOT
15
USE
900-TC16NCOMP3
Communications/
CT2
B
11
RS-485
A
12
13
CT2
14
CT1
15
900-TC16NCOMV2
Communications/
Control Output 2
B
11
RS-485
A
12
DO
NOT
13
USE
+
Control Output 2
Allen-Bradley Company, LLC
Industrial Components Business
1201 South Second Street
Milwaukee, WI 53204-2496 USA
Phone 440.646.5800
Rockwell Automation
CH-5001 Aarau, Switzerland
FAX ++41.62.837.2202
14
-
15
900-TC16P1V2
Control Output 2/
CT
Control Output 2
DO
NOT
USE
CT1
Control
+
11
output 2
-
12
·
Voltage
outputs
13
DC12V
21mA
14
15
Temperatur-Steuergerät
Optionseinheiten
900-TC16NCOM
900-TC16NEIM
900-TC16NACCOM
900-TC16NACEIM
900-TC16NCOMP3
900-TCNCOMV2
900-TC16P1V2
German
41063-223-01 (2)
Printed In China
For detailed operating instructions, please
refer to the 900-TC16 User's Manual.
It can be found online at:
http://www.ab.com/manuals/.
Contrôleur de température
Unités optionnelles
900-TC16NCOM
900-TC16NEIM
900-TC16NACCOM
900-TC16NACEIM
900-TC16NCOMP3
900-TCNCOMV2
900-TC16P1V2
French
41063-223-01 (2)
Printed In China
For detailed operating instructions, please
refer to the 900-TC16 User's Manual.
It can be found online at:
http://www.ab.com/manuals/.
Lieferumfang
Stellen Sie sicher, daß der Karton die folgenden Artikel enthält. Wenn Teile fehlen oder beschädigt sind,
wenden Sie sich an Ihren Fachhändler.
• Optionseinheiten
Modell
900-TC16NCOM
900-TC16NEIM
900-TC16NACCOM
900-TC16NACEIM
900-TC16NCOMP3
900-TCNCOMV2
900-TC16P1V2
Kommunikation (RS-485)
Alarm für das Ausbrennen der Heizung, 1 Alarm (Stromwandler)
Ereigniseingänge, 2 Eingänge
Alarm für das Ausbrennen der Heizung, 1 Alarm (Stromwandler)
Kommunikation (RS-485)
Ereigniseingänge, 2 Eingänge
Kommunikation (RS-485)
Alarme für das Ausbrennen der Heizung, 2 Alarme (Stromwandler)
Kommunikation (RS-485)
Regelausgang 2 (Spannungsausgabe)
Regelausgang 2 (Spannungsausgabe)
Alarm für das Ausbrennen der Heizung, 1 Alarm (Stromwandler)
Montage der Einheit
(1)
(5)
(2)
Wasserdichte Packung
Funktion
(1)
(3)
Vorsichtig behandeln. Keine elektronische Teile berühren, und das
Gerät nicht Stö ßen aussetzen.
(1) Die Werkzeuge (unten gezeigt) in die Schächte
einstecken (einer oben und einer unten), und
die Haken lösen.
(2) Die Seiten der Frontplatte fest greifen, und zum
Entfernen nach vorne ziehen.
(3) Die oberen und unteren Klauen mit angehobe-
nen Anschlußpunkten ansetzen und die Platte
einsetzen.
(4) Verbinden Sie den Klemmenblock der Option
Unit mit dem äußeren Gehäuse.
(5) Sicherstellen, daß die wasserdichte Packung
vorhanden ist, und dann das Außengehäuse in
Position eindrücken. Bis zum hörbaren Klickgeräusch eindrücken.
• Klemmenleiste, 1
• Klemmenaufkleber, 1
Schraubenzieher
(Einheit: mm)
20 min.
(4)
2.0
0.4
Contenu du carton
Assurez-vous que le carton contient les éléments suivants. Si l'un d'entre eux manque ou est endommagé, contactez immédiatement votre fournisseur.
• Unités optionnelles
Modèle
900-TC16NCOM
900-TC16NEIM
900-TC16NACCOM
900-TC16NACEIM
900-TC16NCOMP3
900-TCNCOMV2
900-TC16P1V2
communication (RS-485)
Alarme de dysfonctionnement de l’élément chauffant, 1 alarme (TC)
Entrées événements, 2 entrées
Alarme de dysfonctionnement de l’élément chauffant, 1 alarme (TC)
communication (RS-485)
Entrées événements, 2 entrées
communication (RS-485)
Alarmes de dysfonctionnement de l’élément chauffant, 2 alarmes (TC)
communication (RS-485)
Sortie de contrôle 2 (sorties de tension)
Sortie de contrôle 2 (sorties de tension)
Alarme de dysfonctionnement de l’élément chauffant, 1 alarme (TC)
Assemblage de l'unité
(1)
(5)
(2)
Emballage étanche
Fonction
(1)
Manipulez avec soin. Ne touchez
pas les pièces électroniques et ne
secouez pas l'unité.
(1) Introduisez les outils (voyez le dessin ci-des-
sous) dans les fentes (une en haut et une en
bas) et relâchez les crochets.
(2) Empoignez fermement les côtés du panneau ant-
érieur et tirez celui-ci en avant pour le retirer.
(3) Faites correspondre les griffes supérieures et inf-
érieures aux points de jonction et insérez le tableau.
(4) Fixez le bornier inclus avec l'unité optionnelle au
boîtier extérieur.
(5) Assurez-vous que le sachet d'étanchéité est en
place puis remontez le panneau extérieur jusqu'à ce que vous entendiez un déclic.
• Bornier, 1
• Etiquette des bornes, 1
Tournevis à fente standard (unité: mm)
(3)
(4)
2.0
0.4
20 min.
Technische Daten Connections
Kommunikationseinheit
Schnittstelle: RS-485
Synchronisation: Start-Stopp (asynchron)
Kommunikation: Halb-Duplex
Kommunikationsrate: 1.2/2.4/4.8/9.6/19.2/38.4 kbps
Ereigniseingang Kontakteingang:
EIN: 1 k max., AUS: 100 k min.
Kontaktloser Eingang
EIN: Restspannung: 1.5 V max.
AUS: Leckstrom 0.1 mA max.
Alarm Ausbrennen Heizung
Max. Heizungsstrom: 50 A AC
(Alarm Kurzschluss
Heizung) max. Genauigkeit der Eingangsspannungsanzeige:
±5% FS ±1 Stelle max.
Einstellbereich für den Alarm für das Ausbrennen der
Heizung: 0,1 bis 49,9 A, in 0.1 A-Inkrementen
(Einstellbereich für Alarm für Heizungskurzschluss)
Erkennung EIN Zeit (Erkennung AUS Zeit): 190 ms
Hinweis: Die Werte in Klammern beziehen sich auf die
Alarmeinstellung für
Heizungskurzschluss.
Regelausgang 2 Spannungsausgang: 12 VDC, 21 mA
(mit Kurzschlussschutz)
900-TC16NCOM
Kommunikationen/
Stromwandler
B
11
RS-485
A
12
Nicht
13
verwenden
14
CT1
15
Bringen Sie die selbstklebende Klemmenbeschriftung der Option Unit an der Seite des Temperaturreglers an.
Getrennt erhältliche CTs verwenden: 900-CT1(Lochdurchmesser: 5,8 mm) oder 900-CT3(Lochdurchmesser: 12 mm).
• Einzelheiten zur Bedienung siehe 900-TC16 Anwenderhandbuch.
• Einzelheiten über Kommunikationsspezikationen siehe Bulletin 900
Kommunikation-Anwenderhandbuch.
Caractéristiques techniques Connexions
Communication Interface: RS-485
Synchronisation: MARCHE/ARRET (asynchrone)
Communication: semi-duplex
Vitesse de communication:1.2/2.4/4.8/9.6/19.2/38.4 Ko/s
Entrée événement Entrée avec contact
En fonction: 1k max., hors fonction: 100k min.
Entrée sans contact
En fonction: tension résiduelle 1.5V max.
Hors fonction: courant de fuite 0.1mA max.
Alarme de dysfonctionnement
de l’élément chauffant
Courant maximal de l’élément chauffant : CA 50 A
Précision de l'indication du courant d'entrée : ± 5 % FS ± 1 chiffre max.
(alarme Heater Short)
max.
Plage de réglage de l'alarme de dysfonctionnement
de l’élément chauffant : de 0,1 à 49,9 A, par
incrément de 0,1 A
(Plage de réglage de l'alarme HS)
Temps d'activation de la détection
(temps de désactivation de la détection): 190 ms
Note : Les valeurs entre parenthèses concernent le réglage
de l'alarme Heater Short.
Sortie de contrôle 2 Sortie de tension : 12 Vc.c., 21 mA
(avec une protection de court-circuit)
900-TC16NCOM
Communication /
CT
B
11
RS-485
A
12
Ne pas
13
utiliser
14
CT1
15
Collez l'étiquette adhésive des bornes de l'unité optionnelle sur le côté de la commande de température.
Utilisez séparément les CT disponibles: 900-CT1(Diamètre du trou : 5,8 mm) ou 900-CT3(Diamètre du trou : 12 mm).
• Pour des instructions détaillées sur les opérations, veuillez consulter
le manuel d'utilisation.
• Pour de plus amples détails sur les caractéristiques des
communications, 900-TC16 référez-vous au manuel d'utilisation des
communications du Bulletin 900.
900-TC16NEIM
Ereigniseingänge /
Stromwandler
11
12
EV1
13
EV2
14
CT1
15
900-TC16NEIM
Entrées
événements / CT
11
12
EV1
13
EV2
14
CT1
15
900-TC16NACCOM
Kommunikationen
B
11
RS-485
A
12
Nicht
13
verwenden
Nicht
14
verwenden
Nicht
15
verwenden
900-TC16NACCOM
Communication
B
11
RS-485
A
12
Ne pas
13
utiliser
Ne pas
14
utiliser
Ne pas
15
utiliser
900-TC16NACEIM
Ereigniseingänge
11
12
EV1
13
EV2
Nicht
14
verwenden
Nicht
15
verwenden
900-TC16NACEIM
Entrées
événements
11
12
EV1
13
EV2
Ne pas
14
utiliser
Ne pas
15
utiliser
900-TC16NCOMP3
Kommunikationen/
Stromwandler 2
B
11
RS-485
A
12
13
CT2
14
CT1
15
900-TC16NCOMP3
Communications/
CT2
B
11
RS-485
A
12
13
CT2
14
CT1
15
900-TC16NCOMV2
Kommunikationen/
Regelausgang 2
B
11
RS-485
A
12
Nicht
13
verwenden
+
Regelausgang 2
Allen-Bradley Company, LLC
Industrial Components Business
1201 South Second Street
Milwaukee, WI 53204-2496 USA
Phone 440.646.5800
Rockwell Automation
CH-5001 Aarau, Switzerland
FAX ++41.62.837.2202
Allen-Bradley Company, LLC
Industrial Components Business
1201 South Second Street
Milwaukee, WI 53204-2496 USA
Phone 440.646.5800
Rockwell Automation
CH-5001 Aarau, Switzerland
FAX ++41.62.837.2202
14
15
-
900-TC16NCOMV2
Communications/
Sortie de contrôle 2
B
11
RS-485
A
12
Ne pas
13
utiliser
+
14
Sortie de
contrôle 2
15
-
900-TC16P1V2
Regelausgang 2/
Stromwandler
+
Regelausgang 2
-
Nicht
verwenden
CT1
900-TC16P1V2
Sortie de contrôle 2/
CT
+
Sortie de
contrôle 2
-
Ne pas
utiliser
CT1
Regelausgang 2
11
·
Spannungsausgang:
12
12 VDC, 21 mA
13
14
15
Sortie de
11
contrôle 2
·
Voltage
12
outputs
DC12V
13
21mA
14
15
Contenuto della confezione
Assicurarsi che la scatola contenga i seguenti pezzi. Se qualche pezzo è mancante o danneggiato, contattare immediatamente il rivenditore autorizzato.
• Unità opzionali
Dispositivo di controllo della temperatura
Modello Funzione
Unità opzionali
900-TC16NCOM
900-TC16NEIM
900-TC16NACCOM
900-TC16NACEIM
900-TC16NCOMP3
900-TCNCOMV2
900-TC16P1V
Montaggio dell'unità
Italian
41063-223-01 (2)
Printed In China
For detailed operating instructions, please
refer to the 900-TC16 User's Manual.
It can be found online at:
http://www.ab.com/manuals/.
900-TC16NCOM
900-TC16NEIM
900-TC16NACCOM
900-TC16NACEIM
900-TC16NCOMP3
900-TCNCOMV2
900-TC16P1V2
(1)
(5)
(2)
Comunicazione (RS-485)
Allarme d’interruzione del riscaldatore, 1 allarme (CT)
Ingressi di evento, 2 ingressi
Allarme d’interruzione del riscaldatore, 1 allarme (CT)
Comunicazione (RS-485)
Ingressi di evento, 2 ingressi
Comunicazione (RS-485)
Allarmi d’interruzione del riscaldatore, 2 allarmi (CT)
Comunicazione (RS-485)
Uscita di controllo 2 (uscite di tensione)
Uscita di controllo 2 (uscite di tensione)
Allarme d’interruzione del riscaldatore, 1 allarme (CT)
(1)
Imballaggio a
tenuta d'acqua
le parti elettroniche e non scuotere
l'unità
(1) Inserire gli utensili (vedere la figura sotto)
nelle fessure (una nella parte superiore e
l'altra sul fondo) e sbloccare i ganci.
(2) Afferrare saldamente i lati del pannello ante-
riore e tirarli in avanti per rimuoverlo.
(3) Sovrapporre le griffe superiore e inferiore ai
punti di connessione e inserire la scheda.
(4) Applicare il blocco terminali fornito con
l’unità opzionale all’involucro esterno.
(5) Assicurarsi che la custodia a tenuta
d'acqua si posizioni, poi spingere la scatola
esterna in posizione. Fino ad avvertire lo
scatto.
• Blocco terminali, 1
• Etichetta del terminale, 1
(3)
Maneggiare con cura. Non toccare
Dati caratteristici
Comunicazione Interfaccia: RS-485
Sincronizzazione: Avvio-arresto (asincrono)
Comunicazione: Half duplex
Ingresso evento Ingresso contatto
ON: massimo 1 K , OFF: minimo 100 k
Ingresso senza contatto
ON: Tensione residua 1.5 V massimo
Velocità di trasmissione: 1.2/2.4/4.8/9.6/19.2/38.4 kbps
OFF: Dispersione di corrente 0.1 mA massimo
Collegamenti
900-TC16NCOM
Comunicazioni
CT
B
RS-485
A
Non
utilizzare
CT1
/
11
12
13
14
15
900-TC16NEIM
Ingressi di evento /
CT
11
12
EV1
13
EV2
14
CT1
15
900-TC16NACCOM
Comunicazioni
B
11
RS-485
A
12
Non
13
utilizzare
Non
14
utilizzare
Non
15
utilizzare
900-TC16NACEIM
Ingressi di evento
11
12
EV1
13
EV2
Non
14
utilizzare
Non
15
utilizzare
900-TC16NCOMP3
Comunicazioni/
CT2
B
11
RS-485
A
12
13
CT2
14
CT1
15
900-TC16NCOMV2
Comunicazioni/
Uscita di controllo 2
B
11
RS-485
A
12
Non
13
utilizzare
+
Uscita di controllo 2
14
15
-
900-TC16P1V2
Uscita di controllo 2/
CT
Uscita di
+
11
-
Non
utilizzare
CT1
controllo 2
· Uscita di
12
tensione:
13
14
15
Uscita di controllo 2
12 V c.c., 21 mA
Allarme d’interruzione Corrente massima del riscaldatore: 50 A c.a.
del riscaldatore
(Allarme cortocircuito
riscaldatore) max.
Precisione dell’indicazione della corrente in ingresso:
±5% FS ±1 cifra max.
Intervallo di impostazione dell’allarme dell’interruzione del
Applicare l’etichetta terminale adesiva dell’unità opzionale sul lato dell'unità di controllo della temperatura.
Utilizzare separatamente gli elementi di CT forniti: 900-CT1(Diametro del foro: 5,8 mm) o 900-CT3(Diametro del foro: 12 mm).
riscaldatore: da 0,1 a 49,9 A, in incrementi di 0,1 A
(Intervallo valori allarme cortocircuito riscaldatore)
Tempo di abilitazione del rilevamento
Cacciavite phillips a punta piatta
(unità: mm)
Nota: i valori tra parentesi si riferiscono
all'impostazione dell'allarme di cortocircuito
riscaldatore.
Uscita di controllo 2 Uscita di tensione: 12 V c.c., 21 mA
20 min.
(con circuito di protezione da cortocircuito)
(4)
2.0
0.4
(tempo di disabilitazione del rilevamento): 190 ms
• Per le istruzioni di funzionamento dettagliate, far 900-TC16 riferimento
al manuale dell'utilizzatore.
• Per le caratteristiche di comunicazione dettagliate, far riferimento al
manuale dell'utilizzatore delle comunicazione di Bulletin 900.
Allen-Bradley Company, LLC
Industrial Components Business
1201 South Second Street
Milwaukee, WI 53204-2496 USA
Phone 440.646.5800
Rockwell Automation
CH-5001 Aarau, Switzerland
FAX ++41.62.837.2202
Controlador de temperaturar
Unidades opcionales
900-TC16NCOM
900-TC16NEIM
900-TC16NACCOM
900-TC16NACEIM
900-TC16NCOMP3
900-TCNCOMV2
900-TC16P1V
Spanish
41063-223-01 (2)
Printed In China
For detailed operating instructions, please
refer to the 900-TC16 User's Manual.
It can be found online at:
http://www.ab.com/manuals/.
Contenido de la caja
Verifique que la caja contenga los siguientes elementos, en caso de que alguno de ellos faltara o estuviera dañado, diríjase de inmediato a su comerciante.
• Unidades opcionales
Modelo Función
900-TC16NCOM
900-TC16NEIM
900-TC16NACCOM
900-TC16NACEIM
900-TC16NCOMP3
900-TCNCOMV2
900-TC16P1V2
Comunicación (RS-485)
Alarma de rotura de calentador, 1 alarma (CT)
Entradas de evento, 2 entradas
Alarma de rotura de calentador, 1 alarma (CT)
Comunicación (RS-485)
Entradas de evento, 2 entradas
Comunicación (RS-485)
Alarma de rotura de calentador, 2 alarma (CT)
Comunicación (RS-485)
Salida de control 2 (salida de tensión)
Salida de control 2 (salida de tensión)
Alarma de rotura de calentador, 1 alarma (CT)
Manéjese con cuidado. No toque
las partes electrónicas ni golpee la
unidad.
(1) Inserte las herramientas (vea el dibujo abajo
indicado) en las ranuras (una en la parte
superior y otra en la inferior) y suelte los
ganchos.
(2) Sujete con firmeza los lados del panel frontal
y tire para extraerlo.
(3) Empareje las uñas superior e inferior con los
puntos de conexión e inserte el tablero.
(4) Instale el bloque de terminales incluido en la
Unidad opcional en la carcasa exterior.
(5) Verifique que el empaque hermético esté en
su lugar, luego presione la caja exterior
hasta ubicarla en posición. Debe oír un clic.
• Bloque de terminales, 1
• Rótulo de la terminal, 1
Armado de la unidad
(1)
(5)
(2)
Empaquetadura
hermética
(1)
(3)
(4)
Destornillador plano (unidad: mm)
20 min.
2.0
0.4
Especificaciones
Comunicación Interfaz: RS-485
Sincronización: inicio-detención (asincrónico)
Comunicación: semi dúplex
Entradas de evento Entrada del contacto
ON: máximo 1 K , OFF: mínimo 100 k
Entrada sin contacto
ON: Tensión residual 1.5 V máximo
OFF: Dispersión de corriente 0.1 mA máximo
Alarma de rotura Corriente máxima del calentador: 50 A c.a.
de calentador
(Alarma breve de
calentador) max.
calentador:
190 ms
configuración de la alarma breve.
Salida de control 2 Salida de tensión: 12Vc.c., 21 mA
(con circuito de protección contra cortocircuitos)
Fuente de alimentación 12 V c.c. ±10% para 20 mA
Velocidad de comunicación: 1.2/2.4/4.8/9.6/19.2/38.4 kbps
Precisión de indicación de corriente de entrada:
± 5% FS ± 1 dígito máximo.
Rango de ajuste de la alarma de rotura del
0,1 a 49,9 A, por incrementos de 0,1 A
(Rango de seleción de alarma breve de calentador)
Tiempo de detección ON (tiempo de detección OFF):
Nota: Los valores entre paréntesis se aplican a la
Conexiones
900-TC16NCOM
Comunicación /
CT
B
11
RS-485
A
12
No
13
utilizar
14
CT1
15
900-TC16NEIM
Entradas de evento /
CT
11
12
EV1
13
EV2
14
CT1
15
900-TC16NACCOM
Comunicación
B
11
RS-485
A
12
No
13
utilizar
No
14
utilizar
No
15
utilizar
900-TC16NACEIM
Entradas de evento
11
12
EV1
13
EV2
No
14
utilizar
No
15
utilizar
900-TC16NCOMP3
Comunicación/
CT2
B
11
RS-485
A
12
13
CT2
14
CT1
15
900-TC16NCOMV2
Comunicación/
Salida de control 2
B
11
RS-485
A
12
No
13
utilizar
+
Salida de control 2
14
15
-
Pegue la etiqueta de terminal adhesiva de la unidad opcional en el lado del controlador de temperatura.
Utilice los CT disponibles en forma separada: 900-CT1(Diámetro de agujero: 5,8 mm) o 900-CT3(Diámetro de agujero: 12 mm).
900-TC16P1V2
Salida de control 2/
CT
+
Salida de control 2
-
No
utilizar
CT1
• Para conocer detalles sobre las instrucciones de operación, refiérase
900-TC16 al Manual del Usuario.
• Para conocer detalles relativos a las especificaciones de
comunicación, refiérase al manual del usuario de comunicaciones
Bulletin 900.
Allen-Bradley Company, LLC
Industrial Components Business
1201 South Second Street
Milwaukee, WI 53204-2496 USA
Phone 440.646.5800
Rockwell Automation
CH-5001 Aarau, Switzerland
FAX ++41.62.837.2202
Salida de
11
control 2
12
·Salida de
tensión
13
12Vc.c.,
21 mA
14
15