RKI Instruments CO-01, 01 Series, HS-01S, OX-01, HS-01 Operator's Manual

01 Series
Operator’s Manual
Part Number: 71-0093RK Revision: A Released: 2/2/11
www.rkiinstruments.com
Read and understand this instruction manual before operating instrument. Improper use of the gas monitor could result in bodily harm or death.
Periodic calibration and maintenance of the gas monitor is essential for proper operation and cor­rect readings. Please calibrate and maintain this instrument regularly! Frequency of calibration depends upon the type of use you have and the sensor types. Typical calibration frequencies for most applications are between 1 and 3 months, but can be required more often or less often based on your usage.
01 Series Operator’s Manual
Warranty
RKI Instruments, Inc. warrants the 01 Series Single Gas Monitor sold by us to be free from defects in materials, workmanship, and performance for a period of two (2) years from the date of shipment from RKI Instruments, Inc. This includes the instrument and the original sensor. Replacement parts are warranted for one (1) year from the date of their shipment from RKI Instruments, Inc. An y part s found d efective within the ir warranty period will be repaired or replaced, at our option, free of charge. This warranty does not apply to those items, which by their nature, are subject to deterioration or consumption in normal service, and which must be cleaned, repaired, or replaced on a routine basis. Examples of such items are as follows:
Absorbent cartridges Filter elements, disks, or sheets Pump diaphragms and valves
Warranty is voided by abuse including mechanical damage, alteration, rough handling, o r r epair procedures not in accordance with the instruction manual. This warranty indicates the full extent of our liability, and we are not responsible for removal or replacement costs, local repair costs, transportation costs, or contingent expenses incurred without our prior approval.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY AND ALL OTHER WARRANTIES
AND REPRESENTATIONS, EXPRESSED OR IMPLIED, AND ALL OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF RKI INSTRUMENTS, INC. INCLUDING BUT NOT LIMITED TO THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL RKI INSTRUMENTS, INC. BE LIABLE FOR INDIRECT, INCIDENTAL, OR CONSEQUENTIAL LOSS OR DAMAGE OF ANY KIND CONNECTED WITH THE USE OF ITS PRODUCTS OR FAILURE OF ITS PRODUCTS TO FUNCTION OR OPERATE PROPERLY.
This warranty covers instruments and parts sold to users only by authorized distributors, dealers, and representatives as appointed by RKI Instruments, Inc.
We do not assume indemn ification for any accident or damage caused by the operation of this gas monitor and our warranty is limited to replacement of parts or our complete goods.
01Series Operator’s Manual Warranty
Table of Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Protective Rubber Boots. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Alligator & Belt Clips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Membrane Retainer/Sensor Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Charcoal Filter Disk in CO-01. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Sensor Retainer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Sensor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
LCD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Control Buttons. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Printed Circuit Boards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Alarm Lights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Buzzer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Vibrator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Start Up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Start-up Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Performing a Fresh Air Adjustment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Turning Off the 01 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Measuring Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Displaying the Peak, STEL, and TWA (CO-01 and HS-01) . . . . . . . . . . . . . . . . 11
Displaying the Min and Max (OX-01) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Alarms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Alarm Points. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Displaying and Adjusting the Alarm Points . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Calibration Frequency. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Setting the Fresh Air Reading. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Setting the Span Reading. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Table of Contents 01 Series Operator’s Manual
Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Replacing the Batteries. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Replacing the Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Replacing the Sensor Cover and Charcoal Filter . . . . . . . . . . . . . . . . . . . . . . . . 25
Parts List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
WARNING: Understand this manual before operating the 01 Series.
Substitution of components may impair intrinsic safety. To prevent ignition of a hazardous atmosphere, batteries must only be changed in an area known to be nonhazardous. This unit has not been tested in an oxygen enriched atmosphere (above 21%).
01Series Operator’s Manual Table of Contents
Introduction
Using an advanced microprocessor controlled detection system, the 01 Series Personal Single Gas Monitor detects the presence of either carbon monoxide (CO), hydrogen sulfide (H2S), or oxygen (O2). The 01 Series’s
compact size and easy-to-use design makes it ideally suited for a wide range of applications, including sewage treatment plants, tunnels, hazardous waste sites, petrochemical facilities, oil fields, mines, and chemical plants. The 01 Series is even small enough to be placed conveniently in a pocket. The 01 Series offers the fo llowing features:
Compact design
Fast, accurate response with digital liquid crystal display (L CD)
Visual, audible, an d vibration alarms
Microprocessor control for reliability, ease of use, and advanced
Peak, STEL, and TWA indication for CO-01& HS-01
capabilities
Minimum and maximum indication for OX-01
Over range alarm
Gas, battery, sensor failure, and system failure alarms
Over 3,000 hours operation on one set of alkaline batteries
CSA certified for intrinsic safety in Class I, Division I, Groups A, B, C, and D hazardous atmospheres
Low temperature operation down to -40 °C with the HS-01S
WARNING: The 01 Series detects oxygen deficiency and elevated
levels of oxygen, carbon monoxide, and hydrogen sulfide, all of which can be dangerous or life thre at eni ng. When using the 01 Series, you must follow the instructions and warnings in this manual to assure proper and safe operation of the unit and to minimize the risk of personal injury. Be sure to maintain and periodically calibrate the 01 Series as described in this manual.
1 • Introduction 01 Series Operator’s Manual
Specifications
Table 1: 01 Series Specifications
CO-01 HS-01/HS-01S OX-01
Target Gas Carbon Monoxide
(CO)
Hydrogen Sulfide
(H2S)
Oxygen
(O2)
Detection Range 0 to 500 ppm 0 to 100.0 ppm 0 to 40.0% vol. Display Increment 1 ppm 0.5 ppm 0.1% vol. Detection
Electro Chemic al Electro Chemic al Galvanic Cell
Principle Alarm Points Low 25 ppm
High 50 ppm
TWA 25 ppm
STEL 200 ppm
Low 10.0 ppm High 30.0 ppm
TWA 10.0 ppm STEL 15.0 ppm
Low 19.5% vol.
(decreasing)
High 23.5% vol.
(increasing) Sampling Method Diffusion Diffusion Diffusion Response Time T90 in 30 seconds T90 in 30 seconds T90 in 20 seconds Accuracy ± 5% of reading or
± 5 ppm CO
(whichever is
greater)
± 5% of reading or
± 2 ppm H2S
(whichever is
greater)
± 0.5% O
2
Indication 7-Segment Digital LCD Safety/Regulatory
C US
186718
CSA classified, “C/US”, as Intrinsically Safe. Exia. Class I,
Groups A, B, C, & D. Temperature Code T3.
Power Tw o AAA size Alka line Batte ries Standard, Dur acell MN240 0
or PC2400, Eveready Energizer E92 or EN92
Continuous Operating Hour s
At 25 °C, All Models: Over 3,000 Hours, No Alarms or Backlighing
At -40 °C, HS-01S: 1,500 Hours, No Alarms or Backlighting
Case High-impact Plastic, Dust and Weather Proof Standard
Accessories
Wrist Strap
Rubber protective boots
01Series Operator’s Manual Specifications • 2
Table 1: 01 Series Specifications
CO-01 HS-01/HS-01S OX-01
Optional Accessories
Dimensions and Weight
Operating T em p. & Humidity
Calibration Adapter
Calibration Kit
Alligator Clip
Belt Clip
1.4” (35mm) W x 4.1” (104mm) H x 0.8” (20mm) D; 3.5 oz. (100 g)
CO/HS/OX-01: -20°C to +50°C, below 90% RH (non condensing)
HS-01S: -40°C to +50°C, below 90% RH (non condensing)
3 • S p e c i f i c a t i o n s 01 Series Operator’s Manual
Description
d
This section describes the components of the 01 Series. These components include the 01 Series’ protective rubber boots, case, membrane retainer and filter disks, sensor retainer, sensor, LCD, control buttons, printed circuit boards, alarm lights, buzzer, vibrator, and batteries.
Alarm Lights
Buzzer Opening
Membrane Retainer
Sensor En Boot
Sensor Retainer
POWER
MODE
CO
CO-01
AIR
LCD
Control Buttons
Battery Charging Contacts
Battery Cover
Threaded Inserts
Battery End Boot
Figure 1: Components of the 01 Series
01Series Operator’s Manual Description • 4
Protective Rubber Boots
A protective rubber boot is installed over each end of the 01 Series. The sensor end boot fits over the sensor cover end of the 01 Series and the battery end boot fits over the battery cover end of the 01 Series.
Case
The 01 Series’ sturdy, high-impact plastic case is blue in colo r. The case is suitable for use in many environmental conditions, indoors and out. The unit is dust proof and weather resistant.
The front of the case has an L CD (liqui d crystal display) tha t shows various readings, which are described under “LCD” in this section. T o the left of the LCD is an alarm light. Below the LCD are two black control buttons. The left button is labeled “POW ER /M OD E” and the right button is labeled “AIR ”.
On top of the case and to the left is the 01 Series’s buzzer, which is located inside the unit. To the right of the buzze r is the senso r . The senso r is held in place by the senso r re tainer (the top of the case for th e 01 Series) and two screws. The sensor is prote cted from dirt and m oisture by the sensor cover . The sensor cover is secured by a membran e retainer and a single screw. In the case of the CO-01, a charcoal filter is provided under the sensor cover to protect the CO sensor from hydrogen sulfide and certain hydrocarbons. To the left of the sensor and below the buzzer, is a second alarm light, which is also visible from the front of the case.
The battery compartment is located on the bottom of the case. Access to the compartment is accomplished by turning the captive battery cover screw counterclockwise and by removing the battery compartment door.
There are two threaded holes on the back of the case. These are used to mount the optional alligator clip or belt clip.
Toward the bottom of the back are two battery charging contacts. These contacts are used to charge a Ni-cad battery pack which is available. Consult RKI Instruments, Inc. for information about this option.
The wrist strap connects to the back of the case on the left side, near the top of the unit.
5 • D e s c r i p t i o n 01 Series Operator’s Manual
Loading...
+ 23 hidden pages