ReliOn BP300, 7400REL Instruction Manual

Model 7400REL
BP300 Automatic
Blood Pressure Monitor
ESPAÑOL
ENGLISH
INSTRUCTION MANUAL
Before using the Monitor
Introduction .............................................................................................................3
Safety information...................................................................................................4
Intended use............................................................................................4
Operating the device...............................................................................4
Risk of electrical shock ..........................................................................5
Care and maintenance ............................................................................5
Operating Instructions
Before taking a measurement ..................................................................................6
Know your unit........................................................................................................7
Unit display .............................................................................................................8
Display symbols ......................................................................................................9
Irregular heartbeat symbol......................................................................9
Movement error symbol .........................................................................9
Average value symbol ............................................................................9
Heartbeat symbol....................................................................................9
Using the AC adapter ............................................................................................10
To connect the AC adapter...................................................................11
To disconnect the AC adapter ..............................................................11
Battery installation ................................................................................................12
Setting the date and time .......................................................................................13
Applying the arm cuff ...........................................................................................15
Applying the cuff on the left arm .........................................................15
Applying the cuff on the right arm.......................................................16
Taking a measurement...........................................................................................17
Special conditions.................................................................................20
Using the memory function...................................................................................21
Averaging function...............................................................................21
To display the measurement values......................................................21
To delete all values stored in the memory............................................22
Care and maintenance.................................................................................................24
Error indicators......................................................................................................25
Troubleshooting tips..............................................................................................26
FCC statement .......................................................................................................27
Limited warranty ...................................................................................................28
Specifications ........................................................................................................29
2
INTRODUCTION
Thank you for purchasing the ReliOn® BP300 Automatic Blood Pressure Monitor, Model # 7400REL.
Your new blood pressure monitor uses the oscillometric method of blood pressure measurement. This means the monitor detects your blood’s movement through your brachial artery and converts the movements into a digital reading. An oscillometric monitor does not need a stethoscope so the monitor is simple to use. The ReliOn
®
BP300 Automatic Blood Pressure Monitor, Model # 7400REL comes
with the following components:
• Monitor • Wide Range Cuff • AC Adapter
• Instruction Manual printed in English and Spanish • Quick Start Guide
Please read this instruction manual thoroughly before using the unit. Please keep for future reference. For specific information about your own blood pressure, CONSULT YOUR DOCTOR.
Fill in for future reference.
DATE PURCHASED: __________________
SERIAL NUMBER: ____________________
• Staple your purchase receipt here
SAVE THESE INSTRUCTIONS
3
SAFETY INFORMATION
INTENDED USE
This monitor is designed to measure blood pressure and pulse rate of adults within the range of the designated arm cuff, following the directions provided in this instruction manual. The monitor is designed for home use. Read the Safety Information in this instruction manual before using this monitor.
To assure the correct use of the product, basic safety measures should always be followed including the warnings and cautions listed in this instruction manual.
OPERATING THE DEVICE
Contact your physician for specific information about your blood pressure. Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician or licensed healthcare provider.
DO NOT adjust medication based on measurement results from this blood pressure monitor. Take medication as prescribed by your physician. Only a physician is qualified to diagnose and treat High Blood Pressure.
The monitor is not intended to be a diagnostic device.
If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Contact a physician immediately.
Read all of the information in the instruction manual and any other literature in the box before operating the unit.
Do not use this device on infants or persons who cannot express their intentions.
Read the Special Conditions section of the instruction manual if your systolic pressure is known to be more than 220 mmHg. Inflating to a higher pressure than necessary may result in bruising where the cuff is applied.
SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property.
4
SAFETY INFORMATION
Operate the device only as intended. Do not use the device for any other purpose.
Dispose of the device, components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution.
Do not use a cellular phone near the device. It may result in an operational failure.
Use only authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit.
Use only 1.5V Alkaline batteries with this device. Other types of batteries may damage the unit.
Do not use in a location with moisture, or a location where water may splash on the unit.
RISK OF ELECTRICAL SHOCK
Do not plug or unplug the power cord into the electrical outlet with wet hands.
Do not overload power outlets. Plug the device into the appropriate voltage outlet.
CARE AND MAINTENANCE
Do not subject the monitor to strong shocks, such as dropping the unit on the floor.
Do not submerge the device or any of the components in water.
Store the device and the components in a clean, safe location.
Changes or modification not approved by the manufacturer will void the user warranty. Do not disassemble or attempt to repair the unit or components.
5
BEFORE TAKING A MEASUREMENT
To ensure a reliable reading follow these recommendations:
1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes before taking a measurement. Rest for at least 15 minutes before taking the measurement.
2. Stress raises blood pressure. Avoid taking measurements during stressful times.
3. Measurements should be taken in a quiet place.
4. Remove tight-fitting clothing from your left arm.
5. Sit on a chair with your feet flat on the floor. Rest your left arm on table so that the cuff is at the same level as your heart.
6. Remain still and do not talk during the measurement.
7. Wait 2-3 minutes between measurements. The wait time allows the arteries to return to the condition prior to taking the blood pressure measurement. You may need to increase the wait time depending on your individual physiological characteristics.
8. Keep a record of your blood pressure and pulse readings for your physician. A single measurement does not provide an accurate indication of your true blood pressure. You need to take and record several readings over a period of time. Try to measure your blood pressure at the same time each day for consistency.
6
KNOW YOUR UNIT
Main Unit:
Components:
SET button
Wide Range Cuff
AC Adapter
Air tube
Air plug
Quick Start Guide
Instruction Manual
ON/OFF button
Memory button
USER ID Selection Switch
Up/Down ( ) buttons
Air Jack
Display
AC Adapter Jack
Battery compartment
7
UNIT DISPLAY
Systolic blood pressure
Diastolic blood pressure
Memory symbol
Average value symbol
Heartbeat symbol
Irregular heartbeat symbol
USER ID symbol (A/B)
Blood pressure level indicator
Pulse display and Memory number
Deflation symbol
Battery low indicator
Date/Time Display
Movement error symbol
8
DISPLAY SYMBOLS
IRREGULAR HEARTBEAT SYMBOL ( )
When the monitor detects an irregular rhythm two or more times during the measurement, the Irregular Heartbeat Symbol ( ) will appear on the display with the measurement values.
An irregular heartbeat rhythm is defined as a rhythm that varies by 25% less or 25% more than the average rhythm detected while the monitor is measuring the systolic and diastolic blood pressure.
If the irregular heartbeat symbol ( ) displays with your measurement results, we recommend you consult your physician. Follow the directions of your doctor.
MOVEMENT ERROR SYMBOL ( )
The Movement Error Symbol ( ) is displayed if you move your body during the measurement. Please remove the arm cuff, and wait 2-3 minutes. Reapply the arm cuff and take another measurement.
AVERAGE VALUE SYMBOL ( )
The Average Value Symbol ( ) is displayed when you press the memory button. The most recent average reading appears on the display screen.
HEARTBEAT SYMBOL ( )
The Heartbeat symbol flashes on the display at every heartbeat during the measurement.
Normal Heartbeat
Irregular Heartbeat
Short Long
Blood
pressure
Pulse
Pulse
Blood
pressure
9
Loading...
+ 21 hidden pages