ReliOn 7100REL User Manual

ESPAÑOL
ENGLISH
Automatic Blood Pressure Monitor
Model 7100REL
INSTRUCTION MANUAL
2
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Operating the Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Before Taking a Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Operating Instructions
Know Your Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Unit Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Display Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Heartbeat Symbol ( ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Battery Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Applying the Arm Cuff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Taking a Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Using the Memory function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Care and Maintenance
Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Error Indicators and Troubleshooting Tips . . . . . . . . . . . . . . . . . . . . . .20
FCC Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
TABLE OF CONTENTS
Thank you for purchasing the ReliOn® 7100REL Automatic Blood Pressure Monitor.
3
INTRODUCTION
Fill in for future reference.
DATE PURCHASED: _______________ SERIAL NUMBER: _________________
Staple your purchase receipt here
Your new digital blood pressure monitor uses the oscillometric method of blood pressure measurement. This means the monitor detects your blood’s movement through your brachial artery and converts the movements into a digital reading.
The 7100REL comes with the following components:
• Monitor • Standard Adult Arm Cuff • 4 “AAA” Batteries
• Instruction Manual printed in English and Spanish The ReliOn
®
7100REL Automatic Blood Pressure Monitor is intended
for home use.
SAVE THESE INSTRUCTIONS
Before Using the Unit
4
To assure the correct use of the product basic safety measures should always be followed including the warnings and cautions listed in this instruction manual.
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property.
OPERATING THE DEVICE
Contact your physician for specific information about your blood pressure. Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician or licensed healthcare provider.
The monitor is not intended to be a diagnostic device. If battery fluid should get in your eyes, immediately rinse with plenty
of clean water. Contact a physician immediately. Read all of the information in the instruction manual and any other
literature in the box before operating the unit. This device is intended for use in measuring blood pressure and pulse
rate in the adult population. Do not use this device on infants or persons who cannot express their intentions.
SAFETY INFORMATION
OPERATING THE DEVICE (continued)
Read carefully “Taking a Measurement” No.3 of the instruction manual if your systolic pressure is known to be higher.
Inflating to a higher pressure than necessary may result in bruising where the cuff is applied.
Operate the device only as intended. Do not use the device for any other purpose.
Dispose of the device, components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution.
Do not use a cellular phone near the device. It may result in an operational failure.
Do not inflate the arm cuff when it is not wrapped around your arm. Use only authorized parts and accessories. Parts and accessories not
approved for use with the device may damage the unit. Use only 1.5V “AAA” alkaline batteries with this device. Do not use
any other type of battery. This may damage the unit.
SAFETY INFORMATION
5
CARE AND MAINTENANCE
Do not subject the monitor to strong shocks, such as dropping the unit on the floor.
Do not submerge the device or any of the components in water. Store the device and the components in a clean, safe location. Changes or modification not approved by the manufacturer will void
the user warranty. Do not disassemble or attempt to repair the unit or components.
SAFETY INFORMATION
6
7
BEFORE TAKING A MEASUREMENT
To ensure a reliable reading follow these recommendations:
1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes before taking a measurement. Rest for at least 15 minutes before taking the measurement.
2. Stress raises blood pressure. Avoid taking measurements during stressful times.
3. Measurements should be taken in a quiet place.
4. Remove tight-fitting clothing from your arm.
5. Sit on a chair with your feet flat on the floor. Rest your arm on a table so that the cuff is at the same level as your heart.
6. Remain still and do not talk during the measurement.
7. Wait 2-3 minutes between measurements. The wait time allows the arteries to return to the condition prior to taking the blood pressure measurement. You may need to increase the wait time depending on your individual physiological characteristics.
8. Keep a record of your blood pressure and pulse readings for your physician. A single measurement does not provide an accurate indication of your true blood pressure. You need to take and record several readings over a period of time. Try to measure your blood pressure at about the same time each day for consistency.
8
KNOW YOUR UNIT
Main Unit:
Components:
Arm Cuff
Air Tube
Air Plug (Connects to Air Jack)
Operating Instructions
Air Jack
Battery Compartment
On/Off Start Button
Display
Instruction Manual
ESPAÑOL
ENGLISH
Automatic Blood Pressure Monitor
Model7100REL
INSTRUCTION MANUAL
Four “AAA” Alkaline
(LR03) Batteries
9
UNIT DISPLAY
Diastolic Blood Pressure
Systolic Blood Pressure
Pulse Display
Low Battery Indicator
Heartbeat Symbol
Deflation Symbol
Memory Symbol
The American Heart Association (AHA) recommends the following guideline for upper limit of normal for home blood pressure readings:
AHA Home Guideline for Upper Limit of Normal BP
Systolic Blood Pressure 135 mmHg Diastolic Blood Pressure 85 mmHg
This is a general guideline because blood pressure depends on age and morbidity. The AHA recommends a lower home blood pressure goal for certain patients, including diabetic patients, pregnant women, and patients with renal failure
1
.
WARNING
• The monitor is not intended to be a diagnostic device.
• Contact your physician for specific information about your blood pressure. Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician or licensed healthcare provider.
Heartbeat Symbol ( )
TAKING A MEASUREMENT
The Heartbeat Symbol flashes on the display during the measurement. The Heartbeat Symbol flashes at every heartbeat.
1
American Heart Association Scientific Statement 2004
DISPLAY SYMBOLS
10
11
1. Turn the main unit upside down.
2. Press the indicator on the battery cover and slide the cover off in the direction of the arrow.
3. Install 4 “AAA” size batteries so the + (positive) and - (negative) polarities match the polarities of the battery compartment as indicated.
4. Replace the battery cover. Slide the battery cover as indicated until it clicks into place.
BATTERY INSTALLATION
Battery Cover
12
BATTERY REPLACEMENT
When the Low Battery Indicator appears on the display screen turn the monitor off and remove all the batteries. Replace with four new batteries at the same time.
WARNING
If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Contact a physician immediately.
NOTE: The batteries supplied with the device may have a shorter life.
CAUTION
Dispose of the device, components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution.
BATTERY INSTALLATION
Low Battery Indicator
CAUTION
Read all of the information in the instruction manual and any other literature in the box before operating the unit.
CAUTION
This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express their intentions.
APPLYING THE CUFF ON THE LEFT ARM
1. Make sure the air plug is securely inserted in the main unit.
NOTE: If the cuff is not assembled, lay the cuff flat with the metal D
ring facing down and on the right side. Pass the left edge through the metal D ring to form a loop. The smooth cloth should be inside of the loop.
2. Remove tight-fitting clothing from your upper left arm.
APPLYING THE ARM CUFF
13
14
3. Apply the cuff to your left upper arm so the blue arrow is centered on the inside of your arm and aligned with your middle finger. The air tube runs down the inside of your arm. The bottom of the cuff should be approximately 1/2" above your elbow.
4. Wrap the cuff firmly in place around your arm using the closure strip.
APPLYING THE ARM CUFF
1/2 inch (1 - 2 cm)
Air Tube
Blue Arrow
15
APPLYING THE CUFF ON THE RIGHT ARM
When taking a measurement using the right arm use this instruction for Step 4 on page 14.
Apply the cuff to your right upper arm so the blue arrow and the air tube runs along the side of your arm. The bottom of the cuff should be approximately 1/2'' above your elbow.
NOTE: Be careful not to rest your arm on the air tube. This will restrict
the flow of air to the cuff.
APPLYING THE ARM CUFF
CAUTION
Operate the device only as intended. Do not use the device for any other purpose.
1. Sit on a chair with your feet flat on the floor. Place your left arm on a table so the cuff is level with your heart.
Remain still and do not move your arm until the entire measurement is complete.
2. Press the ON/OFF START button.
All symbols appear on the display.
CAUTION
Inflating to a higher pressure than necessary may result in bruising where the cuff is applied.
TAKING A MEASUREMENT
16