TABLE OF CONTENTS
Before using the Monitor
Introduction .............................................................................................................3
Safety information...................................................................................................4
Intended use............................................................................................4
General usage .........................................................................................4
General usage .........................................................................................5
Battery usage ..........................................................................................5
General precautions................................................................................6
Operating Instructions
Before taking a measurement..................................................................................7
Know your unit........................................................................................................8
Unit display .............................................................................................................9
Display symbols ....................................................................................................10
Irregular heartbeat symbol....................................................................10
Movement error symbol .......................................................................10
Average reading symbol.......................................................................10
Heartbeat symbol..................................................................................10
Blood pressure level indicator..............................................................10
Battery installation ................................................................................................12
Setting the date and time .......................................................................................13
Setting the positioning indicator............................................................................14
Setting the positioning indicator...........................................................14
Applying the wrist cuff..........................................................................................15
Applying the cuff on the left wrist .......................................................15
Applying the cuff on the right wrist .....................................................15
Taking a measurement...........................................................................................16
Using the memory function...................................................................................18
To view the measurement values stored in memory ............................18
To view the average reading ................................................................19
To delete all values in the memory ......................................................19
Care and Maintenance ................................................................................................20
Error indicators......................................................................................................21
Troubleshooting tips..............................................................................................22
FCC statement .......................................................................................................23
Limited warranty ...................................................................................................24
Specifications ........................................................................................................25
Guidance and manufacturer’s declaration.............................................................26
2
INTRODUCTION
Thank you for purchasing the ReliOnTM BP300W Wrist Blood Pressure Monitor, Model # 6021RELN2.
The monitor is compact and easy-to-use at home, at work, and during travel. Perfect for people who frequently monitor their own blood pressure. Your new digital blood pressure monitor uses the oscillometric method of blood pressure measurement. This means the monitor detects your blood’s movement through your brachial artery and converts the movements into a digital reading. An oscillometric monitor does not need a stethoscope so the monitor is simple to use. Clinical research has proven a direct relationship between blood pressure in the wrist and blood pressure in the arm. Changes in wrist blood pressure reflect changes in arm blood pressure because the arteries in the wrist and the arm are close to each other. Frequently measuring the blood pressure in your wrist will provide your physician with an accurate indication of changes in your blood pressure. The 6021RELN2 comes with the following components:
• Monitor • 2 “AAA” Alkaline Batteries
• Instruction Manual • Quick Start Guide Please read this instruction manual thoroughly before using the unit. Please keep
for future reference. For specific information about your own blood pressure, CONSULT YOUR DOCTOR.
Fill in for future reference.
DATE PURCHASED: __________________
SERIAL NUMBER: ____________________
• Staple your purchase receipt here
SAVE THESE INSTRUCTIONS
3
4
SAFETY INFORMATION
SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property.
GENERAL USAGE
The monitor is not intended to be a diagnostic device.
Note that PATIENT motion, trembling, shivering may affect the measurement value. Do not use the device on the injured wrist or the wrist under medical treatment.
Consult your physician before using the device on the wrist with an arterio-venous (A-V) shunt.
Do not use the device with other medical electrical (ME) equipment simultaneously.
INTENDED USE
This device is a digital monitor intended for use in measuring blood pressure and pulse rate in adult patient population. The device detects the appearance of irregular heartbeats during measurement and gives a warning signal with the readings.
To assure the correct use of the product, basic safety measures should always be followed including the warnings and cautions listed in this instruction manual.
DO NOT adjust medication based on measurement values from this blood pressure monitor. Take medication as prescribed by your physician. Only a physician is qualified to diagnose and treat High Blood Pressure.
Consult your physician before using the device for any of the following conditions: common arrhythmias such as atrial or ventricular premature beats or atrial fibrillation, arterial sclerosis, poor perfusion, diabetes, age, pregnancy, pre-eclampsia, renal diseases.
Do not use the device in the area of HF surgical equipment, MRI, or CT scanner, or in an oxygen rich environment.
Contains small parts that may cause a choking hazard if swallowed by infants and small children.
5
SAFETY INFORMATION
Consult your physician before using the device for any of the following conditions:
Always consult your physician. Self-diagnosis of measurement values and self-treatment are dangerous.
• If you have had a mastectomy.
• If you have a condition that may compromise circulation, you may get an inaccurate reading with this device.
• People with severe blood flow problems or blood disorders as cuff inflation can cause bruising.
Do not take measurements more than necessary. It may cause bruising due to blood flow interference.
Do not use this device on infants or persons who cannot express their intentions.
Do not use a cellular phone near the device. It may result in an operational failure.
BATTERY USAGE
GENERAL USAGE
Do not insert the batteries with their polarities incorrectly aligned. Use only 2 “AAA” Alkaline batteries with this device. Do not use other types of
batteries. Do not use new and used batteries together.
Do not use the device for any purpose other than measuring blood pressure.
Remove the batteries if the device will not be used for three months or more. If battery fluid should get in your eyes, immediately rinse with plenty of clean water.
Contact a physician immediately.
Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit.
Dispose of the device, components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution.
6
SAFETY INFORMATION
• Store the device and the components in a clean, safe location.
GENERAL PRECAUTIONS
• Do not submerge the device or any of the components in water.
• Do not use the device outside the specified environment. It may cause an inaccurate reading.
• Do not drop the monitor or subject device to strong shocks or vibrations.
7
To ensure a reliable reading follow these recommendations:
1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes before taking a measurement. Rest for at least 5 minutes before taking the measurement.
2. Stress raises blood pressure. Avoid taking measurements during stressful times.
3. The cuff can be applied to your left or right wrist.
4. Measurements should be taken in a quiet place.
5. Position the unit at heart level throughout the measurement.
6. Remain still and do not talk during the measurement.
7. Keep a record of your blood pressure and pulse readings for your physician. A single measurement does not provide an accurate indication of your true blood pressure. You need to take and record several readings over a period of time. Try to measure your blood pressure at the same time each day for consistency.
BEFORE TAKING A MEASUREMENT
8
2 “AAA” Alkaline Batteries
Instruction Manual
Main Unit:
Components:
Quick Start Guide
Display
Battery compartment
Start/Stop button
Wrist cuff
User selection switch
Memory button
6021RELN2
3200784-2A
Thank you for purchasing the ReliOnTM BP300W Wrist Blood Pressure Monitor, Model # 6021RELN2.
Date/Time setting ( ) button
TM
TM
BP300W Wrist
Up ( ) button
Blood Pressure Monitor
Quick Start Guide
KNOW YOUR UNIT
9
Positioning indicator symbol Pulse display and
Memory number
Movement error symbol
Heartbeat symbol (Flashes during measurement)
Irregular heartbeat symbol
User symbol (A or B)
Date/Time display
Deflation symbol
Battery symbol
(low/depleted)
Average reading symbol
Diastolic blood pressure
Systolic blood pressure
Blood pressure level indicator (
High/Normal
)
Memory symbol
UNIT DISPLAY
10
IRREGULAR HEARTBEAT SYMBOL ( )
When the monitor detects an irregular rhythm two or more times during the measurement, the Irregular Heartbeat Symbol will appear on the display with the measurement values.
An irregular heartbeat rhythm is defined as a rhythm that varies by 25% less or 25% more than the average rhythm detected while the monitor is measuring the systolic and diastolic blood pressure.
If the irregular heartbeat symbol displays with your measurement values, we recommend you consult your physician. Follow the directions of your doctor.
MOVEMENT ERROR SYMBOL ( )
The Movement Error Symbol is displayed if you move your body during the measurement. Please remove the wrist cuff, and wait 2-3 minutes. Re-apply the wrist cuff and take another measurement.
AVERAGE READING SYMBOL ( )
The Average Reading Symbol is displayed when you press and hold the Memory button for more than 3 seconds. The most recent average reading appears on the display screen.
Normal Heartbeat
Irregular Heartbeat
Short Long
Blood
pressure
Pulse
Pulse
Blood
pressure
HEARTBEAT SYMBOL ( )
The Heartbeat symbol flashes on the display at every heartbeat during the measurement.
BLOOD PRESSURE LEVEL INDICATOR ( )
If your Systolic Blood Pressure is 135 mmHg or above and/or the Diastolic Blood Pressure is 85 mmHg or above, the High blood pressure level indicator (
) will display when the measurement value is displayed.
If the measurements are within the standard range, the Normal blood pressure level indicator ( ) will display.
DISPLAY SYMBOLS