Important operating
and maintenance
instructions included.
• Read, understand and
follow these instructions
for safe installation and
operation.
WARNING
If the information in these instructions is not followed exactly, a
fi re may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• Do not overfi re - If heater or chimney con-
nector glows, you are overfi ring. Overfi ring
will void your warranty.
• Comply with all minimum clearances to
combustibles as specifi ed. Failure to
comply may cause house fi re.
CAUTION
• Keep children away.
• CAREFULLY SUPERVISE children in same room as
• Alert children and adults to hazards of high
• Do NOT operate with protective barriers removed or
• Keep clothing, furniture, draperies and other
Millennium Model
• Leave this manual with
party responsible for
use and operation.
HOT! DO NOT TOUCH.
SEVERE BURNS MAY RESULT.
CLOTHING IGNITION MAY RESULT.
Glass and other surfaces are hot
during operation and cool down.
appliance.
temperatures.
door open.
combustibles away.
WARNING
DO NOT
DISCARD
Installation and service of this appliance should
be performed by qualifi ed personnel. Hearth &
Home Technologies recommends NFI certifi ed
professionals, or technicians supervised by an
NFI certifi ed professional.
www.quadrafi re.com
7033-277C
Fire Risk.
For use with solid wood fuel only.
Other fuels may overfi re and generate
poisonous gases (i.e. carbon monoxide).
WARNING
March 2, 2007
3100 Wood Stove Series (ACC)
and Welcome to the Quadra-Fire Family!
Hearth & Home Technologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance,
you have our assurance of commitment to quality , durability, and performance.
This commitment begins with our research of the market,
including ‘Voice of the Customer’ contacts, ensuring we
make products that will satisfy your needs. Our Research
and Development facility then employs the world’s most
advanced technology to achieve the optimum operation
of our stoves, inserts and fi replaces. And yet we are old-
fashioned when it comes to craftsmanship. Each unit is
With warm regards,
R
meticulously fabricated and gold and nickel surfaces are
hand-fi nished for lasting beauty and enjoyment. Our pledge
to quality is completed as each model undergoes a quality
control inspection. From design, to fabrication, to shipping:
Our guarantee of quality is more than a word, it’s QuadraFire tradition, and we proudly back this tradition with a Limited Lifetime Warranty.
We wish you and your family many years of enjoyment in
the warmth and comfort of your hearth appliance. Thank
you for choosing Quadra-Fire.
___________________________
Alan Trusler
Senior
Vice President
Dealer Channel
t
___________________________
Dan Henry
Vice President
Advanced Technolgies
_________________________
Jason Olmstead
Vice President &
General Manager
SAMPLE OF SERIAL NUMBER / SAFETY LABEL
LOCATION: BACK OF APPLIANCE
___________________________
Steve Tate
Quadra-Fire
Brand Manager
Serial No.
Model
Name
Test Lab &
Report No.
Page 2
SAMPLE
7033-277C
Mfg. Date
March 2, 2007
R
3100 Wood Stove Series (ACC)
TABLE OF CONTENTS
Section 1: Listing and Code Approvals
A. Appliance Certifi cations ......................4
B. Mobile Home Approved ......................4
C. Glass Specifi cations ............................4
A. Fire Safety ...........................................25
B. Wood Selection & Storage ..................25
C. Burning Process ..................................25-26
D.
E. Air Controls .........................................26-27
F. Burn Rates & Operating Effi ciency .....27
G. Building A Fire .....................................28
Automatic Combustion Control (ACC)
....26
March 2, 2007
7033-277C
Page 3
3100 Wood Stove Series (ACC)
Listing and Code Approvals
1
R
A. Appliance Certifi cation
Model:
Laboratory:OMNI Test Laboratories, Inc.
Report No & Date:
Type:
Standard:UL1482 and ULC S627 and (UM)
The Quadra-Fire 3100 Series Wood Stove (ACC) meets the
U.S. Environmental Protection Agency’s 1990 particulate
emission standards.
3100 Millennium & Step Top (ACC)
Uni-Body
061-S-66-6
Wood Stove
84-HUD, Mobile Home Approved.
B. Mobile Home Approved
This appliance is approved for mobile home installations
when not installed in a sleeping room and when an outside
combustion air inlet is provided. The structural integrity of
the mobile home fl oor , ceiling, and walls must be maintained.
The appliance must be properly grounded to the frame of
the mobile home and use only listed double-wall connector
pipe. Outside Air Kit, part OAK-ACC must be installed in a
mobile home installation
this appliance, reserves the right to alter its products,
their specifi cations and/or price without notice.
1.1 grams per hour
79.51%
11,800 to 32,000
up to1,800 sq ft
6 inches
2 cubic feet
18 inches
Cord Wood
325 lbs
C. Glass Specifi cations
This stove is equipped with 5mm ceramic glass. Replace
glass only with 5mm ceramic glass. Please contact your
dealer for replacement glass.
NOTE: This installation must conform with local codes. In the
absence of local codes you must comply with the UL1482,
(UM) 84-HUD and NPFA211 in the U.S.A. and the ULC S627
and CAN/CSA-B365 Installation Codes in Canada.
Page 4
7033-277C
March 2, 2007
R
3100 Wood Stove Series (ACC)
2
A
. Design, Installation & Location Considerations
Consideration must be given to:
• Safety
• Convenience
• Traffi c fl ow
• Chimney and chimney connector required
It is a good idea to plan your installation on paper, using exact
measurements for clearances and fl oor protection, before
actually beginning the installation. If you are not using an
existing chimney, place the appliance where there will be a
clear passage for a factory-built listed chimney through the
ceiling and roof.
We recommend that a qualifi ed building inspector and your
insurance company representative review your plans before
and after installation
If this appliance is in an area where children may be near it
is recommended that you purchase a decorative barrier to go
in front of the appliance.
away while it is operating and do not let anyone operate
this appliance unless they are familiar with these operating
instructions.
Service / Maintenance Tip:
In order to replace the tube channel a clearance of 19
inches (483mm) is required on the right side of stove in
order to remove the tubes with the stove in place. If space
is not available, the stove will have to be disconnected from
the chimney to proceed with the tube replacement. See
page 35.
Getting Started
Remember to always keep children
CAUTION
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and
national codes and regulations.
• Consult insurance carrier, local building, fi re offi cials or
authorities having jurisdiction about restrictions, installation
inspection, and permits.
WARNING
B. Fire Safety
To provide reasonable fi re safety, the following should be
given serious consideration:
1. Install at least one smoke detector on each fl oor of
your home to ensure your safety. They should be
located away from the heating appliance and close
to the sleeping areas. Follow the smoke detector
manufacturer’s placement and installation instructions,
and be sure to maintain regularly.
2. A conveniently located Class A fire extinguisher
to contend with small fires resulting from burning
embers.
3. A practiced evacuation plan, consisting of at least two
escape routes.
4. A plan to deal with a chimney fi re as follows:
In the event of a chimney fi re:
a. Notify fi re department
b. Prepare occupants for immediate evacuation.
c. Close all openings into the stove.
d. While awaiting fi re department, watch for ignition
of adjacent combustibles from overheated stove
pipe, hot embers or sparks from the chimney.
WARNING
Fire Risk.
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be
voided by, the following actions:
• Installation and use of any damaged appliance.
• Modifi cation of the appliance.
• Installation other than as instructed by Hearth & Home
Technologies.
• Installation and/or use of any component part not approved
by Hearth & Home Technologies.
• Operating appliance without fully assembling all
components.
• Operating appliance without legs attached (if supplied with
unit).
• Do NOT Overfi re - If appliance or chimney connector glows,
you are overfi ring.
Any such action that may cause a fi re hazard.
Asphyxiation Risk.
March 2, 2007
• Do NOT connect this unit to a chimney fl ue
servicing another appliance.
• Do NOT connect to any air distribution duct or
system.
May allow fl ue gases to enter the house.
7033-277C
WARNING
Fire Risk.
• Do not operate appliance before reading and
understanding operating instructions.
• Failure to operate appliance properly may
cause a house fi re.
Page 5
3100 Wood Stove Series (ACC)
C. Negative Pressure
R
Draft is the pressure difference needed to vent appliances
successfully. Considerations for successful draft include:
• Preventing negative pressure
• Location of appliance and chimney
Negative pressure results from the imbalance of air avail-
able for the stove to operate properly . Causes for this imbalance include:
• Exhaust fans (kitchen, bath) etc.)
• Range hoods
• Combustion air requirements for furnaces, water
heaters and other combustion appliances
• Clothes dryers
• Location of return-air vents to furnace or air conditioning
• Imbalances of HVAC air handling system
• Upper level air leaks
• Recessed lighting
• Attic hatch opening
• Duct leaks
To minimize the affects of negative air pressure the following
must be considered:
• Install the outside air kit. Install the intake on the
side of the house towards prevailing winds during the
heating season.
• Ensure adequate outdoor air is supplied for combustion appliances and exhaust equipment.
• Ensure furnace and air conditioning return vents are
not located in the immediate vicinity of the appliance,
• Avoid installing the appliance near doors, walkways
or small isolated spaces.
• Recessed lighting should be of “sealed can” design;
attic hatches weather stripped or sealed; and attic
mounted duckwork and air handler joints and seams
taped or sealed.
WARNING
Asphyxiation Risk.
Windward
Location
Not
Recommended
Outside Termination Cap
Marginal
Location
Recommended
Location
• Negative pressure can cause spillage of combustion fumes, soot and carbon monoxide.
• Appliance needs to draft properly for safety.
Recommended
Location
Location NOT
Recommended
Leeward
Multi-level Roofs
Figure 6.1
Page 6
7033-277C
March 2, 2007
R
3100 Wood Stove Series (ACC)
D. Flue Draft Considerations
Location of the appliance and chimney will affect performance. As shown in Figure 6.1on page 6 the chimney
should:
• Be installed through the warm space enclosed by the
building envelope. This helps to produce more draft,
especially during lighting and die down of the fi re.
• Penetrate the highest part of the roof. This minimizes
the affects of wind turbulence and down drafts.
• Consider the appliance location in order to avoid
fl oor and ceiling attic joists and rafters.
Exterior conditions such as roof line, surrounding trees,
prevailing winds and nearby hills can influence stove
performance. Y our local dealer is the expert in your geographic
area and can usually make suggestions or discover solutions
that will easily correct your fl ue problem.
T
o be sure that your appliance burns properly, the chimney
draft (static pressure) should be approximately -.04 inch water
column (W.C.) during a low burn and -.10 inch W.C. during a
high burn, measured 6 inches (152mm) above the top of the
appliance after one hour of operation at each burn setting.
NOTE: These are guidelines only, and may vary somewhat
for individual installations.
E. Venting Systems
The venting system consists of a chimney connector (also
known as stove pipe) and a chimney. These get extremely
hot during use. Temperatures inside the chimney may
exceed 2000°F (1 100°C) in the event of a creosote fi re. To
protect against the possibility of a house fi re, the chimney
connector and chimney must be properly installed and maintained. An approved thimble must be used when a
connection is made through a combustible wall to a chimney .
A chimney support package must be used when a connection
is made through the ceiling to a prefabricated chimney.
These accessories are absolutely necessary to provide
safe clearances to combustible wall andceiling material.
Follow venting manufacturer’s clearances when installing
venting system.
F. Tools And Supplies Needed
Before beginning the installation be sure that the following
tools and building supplies are available.
Reciprocating saw
Pliers
Hammer
Phillips Head Screwdriver
Flat Blade Screwdriver
Plumb Line
Level
Tape Measure
Framing Material
Hi-Temp Caulking Material
Gloves
Framing Square
Electric Drill & Bits (1/4”)
Safety Glasses
1/2 in. - 3/4 in. length, #6 or
#8 self drilling screws (need 3
per pipe section connection)
G. Inspect Appliance & Components and
Pre-Use Check List
1.Place the appliance in a location near the fi nal
installation area and follow the procedures below:
2.Open the appliance and remove all the parts and
articles packed inside the Component Pack. Inspect
all the parts and glass for shipping damage. Contact
your dealer if any irregularities are noticed.
3.All safety warnings have been read and followed.
4.This Owner’s Manual has been read.
5.Floor protection requirements have been met.
6.Venting is properly installed.
7.The proper clearances from the appliance and chimney to combustible materials have been met.
8.The masonry chimney is inspected by a professional
and is clean, or the factory built metal chimney is
installed according to the manufacturer’s instructions and clearances.
9.The chimney meets the required minimum height.
10.
11.Plated surfaces have been wiped clean, if appli-
12.A power outlet is available nearby if installing
All labels have been removed from the glass door.
cable.
optional blower assembly.
March 2, 2007
WARNING
Asphyxiation Risk.
• Do NOT connect this unit to a chimney fl ue
servicing another appliance.
• Do NOT connect to any air distributon duct
or system.
May allow fl ue gases to enter the house.
7033-277C
WARNING
Fire Risk.
Inspect appliance and components for damage.
Damaged parts may impair safe operation.
• Do NOT install damaged components.
• Do NOT install incomplete components.
• Do NOT install substitute components.
Report damaged parts to dealer.
Page 7
3100 Wood Stove Series (ACC)
R
H. Typical Stove Systems
Stove system with masonry chimney
consists of:
• Stove
• Chimney Connector (stove pipe)
• Thimble
• Masonry Chimney
• Hearth Pad Floor Protection
Spark Arrestor Cap
1" (25mm) Clearance
With Firestop
Ceiling Joist
Combustible Wall
Thimble,
12" (305mm)
Of Brick
Floor
Protector
Concrete Cap
Fireclay Flue Liner
With Air Space
Rafter
Flashing
Eave
Sheathing
Outside Air Rear Vent
Outside Air
Termination Cap
Stove system with prefabricated
metal chimney consists of:
INSTALLATION: ALCOVE
factory-built Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor). Maximum depth of Alcove
shall be no more than 48 inches (1220mm) with a minimum height of 48 inches (1220mm) to top of unit, and the referenced clearances.
*In Canada must comply with CAN/ULC-S269 M87 for the 650
• Comply with all minimum clearances to
combustibles as specifi ed.
• Failure to comply may cause house fi re.
Six inch (6") (152mm) diameter listed Double Wall air insulated connector pipe with UL103 HT* listed
o
C Factory-built chimney.
SERVICE / MAINTENANCE TIP
In order to replace the tube channel assembly a clearance
of 19 inches (483mm) is required on the right side of stove in
order to remove the tubes with the stove in place. If space
is not available, the stove will have to be disconnected from
the chimney to proceed with the tube replacement.
7033-277C
Page 11
3100 Wood Stove Series (ACC)
Installation
4
A. Hearth Protection Requirements
FLOOR PROTECTION: Floor protector must be non-com-
bustible material, extending beneath heater and to the front,
sides and rear as indicated. The fl oor must be non-com-
bustible or otherwise adequately protected from radiant heat
given off by the unit and from sparks and falling embers. A
layer of thin brick or ceramic tile over a combustible fl oor is
not suffi cient.
For the Millennium Model In US installations, i
essary to install a fl oor protector of a minimum of 3/8 inch
(9.5mm) thick metal clad millboard or equivalent a minimum
of 16
inches (406mm) in front of glass and 8 inches (203mm)
to both sides of the fuel loading door. Open the door and
measure 8 inches (203mm) from the side edge of the opening in the face of the appliance. *See exception.
t is nec-
Millennium Model
R
In Canada, similar fl oor protection must be provided 18
inches (457mm) in front and 8 inches (203mm) from the
sides and rear of the stove. *See exception.
*EXCEPTION: Non-combustible fl oor protections must
extend beneath the fl ue pipe when installed with horizontal
venting and extend 2 inches (51mm) beyond each side.
See Figure 12.4.
WARNING
Fire Risk.
• Hearth pads must be installed exactly as
specified.
High temperatures or hot embers may ignite
concealed combustibles.
Figure 12.1
203mm
(8 in.)
4-7/8 in.
Fuel loading door
16" from glass
31-5/8 in.
minimum
203mm (8 in.)
3-1/8 in."
8 in.
USA
203mm
(8 in.)
39-5/8 in.
minimum
1260mm
(49-5/8 in.)
minimum
49-7/8 in.
Figure 12.3
49-7/8 in.
e
g
a
r
ve
co
.
l
n
a
i
n
8
o
/
i
t
5
p
-
o
1
3
l
t
p
o
co
a
n
o
i
a
r
ve
27-5/8 in.
e
g
8
/
5
-
9
3
USA required
Canada recommended
l
a
e
n
g
o
i
a
t
r
p
o
ve
co
.
n
i
a
6
r
1
ve
co
.
n
i
d
e
r
i
u
q
e
r
1
27-5/8 in.
.
n
i
e
g
.
n
i
8
/
7
-
5
8
/
3
-
11
USA
Figure 12.2
Page 12
457mm (18 in.)
1041mm (41 in.)
minimum
CANADA
7033-277C
Must extend 2 in. (51mm) beyond
each side of pipe (shaded area)
Figure 12.4
March 2, 2007
R
4
3100 Wood Stove Series (ACC)
Step-Top Uni-Body Model
For the Step T op Pedestal Model In US installations, i
t is
necessary to install a fl oor protector of a minimum of 3/8 inch
(9.5mm) thick metal clad millboard or equivalent a minimum of
16
inches (406mm) in front of glass and 8 inches (203mm)
to both sides of the fuel loading door. Open the door and
measure 8 inches (203mm) from the side edge of the opening in the face of the appliance. *See page 12 for Canadian
clearances and horizontal venting exception.
4-3/4 in.
Fuel loading door
16 in. from glass
3-1/4 in.
39-5/8 in.
minimum
8 in.
USA
31-5/8 in.
minimum
Figure 13.1
For the Step T op Leg Model In US installations, i
t is necessary to install a fl oor protector of a minimum thickness of
1-1/4 inch (32mm) or 1/2 inch of “k” value of 0.84 thick metal
clad millboard or equivalent a minimum of 16
inches (406mm)
in front of glass and 8 inches (203mm) to both sides of the
fuel loading door. Open the door and measure 8 inches
(203mm) from the side edge of the opening in the face of
the appliance. *See page 12 for Canadian clearances and
horizontal venting exception.
8 in.
49-7/
o
8 in.
9-7/
o
Figure 13.3
o
i
t
p
o
i
t
p
co
ve
co
l
a
n
1
3
l
a
e
n
g
a
r
ve
27-5/8 in.
e
g
a
r
.
n
i
8
/
5
-
.
n
i
8
/
5
-
9
3
q
e
r
l
a
e
n
g
o
i
a
t
r
p
o
ve
co
27-5/8 in.
.
n
e
i
g
a
6
r
1
ve
co
d
e
r
i
u
.
n
i
8
/
7
-
5
1
.
n
i
8
/
3
-
11
USA
USA required
Canada recommended
203mm (8 in.)
203mm
(8 in.)
203mm
(8 in.)
1254mm
(49-3/8 in.)
minimum
457mm (18 in.)
CANADA
1041mm (41 in.)
minimum
Figure 13.2
NOTE:
• Illustrations and photos refl ect typical installations and are FOR DESIGN PURPOSES ONLY.
Figure 13.4
Must extend 2 in. (51mm) beyond
each side of pipe (shaded area)
• Illustrations/diagrams are not drawn to scale.
• Actual installation may vary due to individual design preference
• Hearth & Home Technologies reserves the right to alter its products.
March 2, 2007
7033-277C
Page 13
3100 Wood Stove Series (ACC)
o
R
B. Outside Air Kit Installation
A source of air (oxygen) is necessary in order for combustion to take place. Whatever combustion air is consumed
by the fi re must be replaced. Air is replaced via air leak-
age around windows and under doors. In homes that have
tightly sealed doors and windows, an outside air source is
needed. An optional Outside Air Kit is avail
Included in OAK-ACC: Termination cap, (2) wire ties, flex
adapter, and fasteners
Included in SRV7033-041: Cover plate and sealing rope (see
Floor Installation Alternative below,
Figure 14.2)
Items Needed for Installation (not supplied)
• 4 inch fl ex aluminum pipe, or if using alternate material,
then it shall be made from durable, non-combustible,
heat resistant material up to 350oF. Cut the pipe to
the required length for your installation.
• Phillips head screw driver
• Silicone sealant
• Drills and saws necessary for cutting holes through
the wall or fl ooring in your home.
able.
WARNING
Fire Risk.
Asphyxiation Risk.
Do not draw outside combustion air from:
• Wall, fl oor or ceiling cavity
• Enclosed space such as an attic or garage
• Close proximity to exhaust vents or
chimneys
Fumes or odor may result
WARNING
Asphyxiation Risk.
Outside air inlet must be located to prevent blockage from:
• Leaves
• Snow or ice
• Other debris
Block may cause combustion air starvation
Smoke spillage may set off alarms or irritate sensi-
tive individuals.
1. Remove all materials from packing box.
2. Using a #2 Phillips screw driver attach the fl ex adapter
to the stove using 4 screws. Figure 14.1
3.
Remove circular” knock-out” in the base of the pedestal.
4.Floor & Rear Installation: Cut a 4 inch (102mm)
hole in outside wall or fl oor to accommodate outside
air piping. Use 4 inch (102mm) aluminum metal fl ex or
rigid piping to directly connect outside air to appliance
intake. Use the supplied termination cap with a rodent
screen. Seal between the wall (or fl oor) and the pipe
with silicone to prevent moisture penetration.
Flex Adapter
Wire Tie
Remove circular
“knock-out” in base
of pedestal.
Flex Line
Wire Tie
WARNING
Asphyxiation Risk.
Length of outside air supply duct shall NOT exceed
the length of the vertical height of the exhaust fl ue.
• Fire will not burn properly
• Smoke spillage occurs when door is opened due
to air starvation.
5. Floor Installation Alternative: In some instances you
may not be able to install the fl ex pipe as show in Figure
14.1. If that is the case, you will need to order SRV7033041 which includes a cover plate and sealing rope as
shown in Figure 14.2. The goal is to seal the pedestal
so no room air can leak into the pedestal.
Terminati
Cap
Rope to Seal
Pedestal
Cover
Plate
Figure 14.1 - Floor & Rear Installation
Page 14
7033-277C
Figure 14.2 - Floor Installation Alternative
March 2, 2007
Do not remove
.
R
C. Blower (Optional)
1. Remove the 3 bolts (1/4”-20 Phillips head) on the outer
skin at the bottom rear of appliance.
2. Align holes in mounting fl ange of blower with bolt holes in
appliance. Blower should be positioned at bottom of rear
outer skin as shown in Figure 15.1.
3. Re-insert and tighten bolts, securing blower onto outer
wall of appliance.
4.
Place the bracket containing the snap disc and magnet
under the bottom left rear corner as shown in Figure 15.1.
See page 29 for detailed operating instructions for the
blower and snap disc.
3100 Wood Stove Series (ACC)
CAUTION
Shock Risk.
• Do NOT remove grounding prong from plug.
• Plug directly into properly grounded 3 prong
receptacle.
• Route cord away from appliance.
•
Do NOT route cord under or in front of appliance.
Secure wires
with wire tie.
Snap Disc
Bracket
with Magnet
FAN
HIGH
MANUAL
AUTO
OFF
LOW
MANUAL: Over-rides the
Snap Disc
AUTO: Fan will turn ON/OFF
Automatically by the Snap Disc
Controls the Fan Speed
Figure 15.1
March 2, 2007
7033-277C
Page 15