Prochem C2 10075170, C3 10075210, CHPH 10075260, C2H 10075190, C3HP 10075220 Operating Instructions Manual

...
Page 1
Operating Instructions (ENG)
MODELS: C2 C2H 10075170 10075190 C3 C3HP CHPH 10075210 10075220 10075260
Read instructions before operating the machine.
T
Page 2
MACHINE DATA LOG/OVERVIEW
2
Name: __________________________________________________________________________________________________
Address: _______________________________________________________________________________________________
Phone Number: _________________________________________________________________________________________
MODEL _______________________________________ DATE OF PURCHASE __________________________ SERIAL NUMBER ______________________________ SALES REPRESENTATIVE # _____________________ DEALER NAME ________________________________ OPERATIONS GUIDE NUMBER ___________________
PUBLISHED
__________________________________________
YOUR DEALER
For the name and address of your dealer contact: Windsor Industries
CHEYENNE 86038850 03/08/07
Page 3
Machine Data Log/Overview.........................2
Table of Contents..........................................3
HOW TO USE THIS MANUAL
How to use this Manual.................................1-1
SAFETY
Important Safety Instructions........................2-1
Hazard Intensity Level. .................................2-2
Grounding Instructions..................................2-3
OPERATIONS
Technical Specifications. ..............................3-1
Controls.........................................................3-2
Machine Operation........................................3-3
Pre-Run Machine Inspection......................3-3
Equipment Set-up......................................3-3
Cleaning & Emptying Tanks.......................3-3
Shut Down and Storage.............................3-4
MAINTENANCE
Maintenance .................................................4-1
Daily Maintenance. ....................................4-1
Periodic Maintenance. ...............................4-1
Monthly Maintenance.................................4-1
Semi-Annually............................................4-1
Lubrication .................................................4-1
Storage. .....................................................4-1
Solution Pump Replacement. .......................4-2
Vacuum Motor Replacement ........................4-2
Vacuum Carbon Brush Replacement. ..........4-2
Pump Replacement Parts.............................4-3
Pressure Regulator.......................................4-4
Machine Troubleshooting..............................4-5
TABLE OF CONTENTS
GROUP PARTS LIST
Base Group...................................................5-1
Solution Tank Group................................... .5-3
Pump Group 100 PSI
No Heat 2 St Vac ......................................5-5
Pump Group 100 PSI
No Heat 3 St Vac.......................................5-7
Pump Group 100 PSI
With Heat 2 St Vac ....................................5-9
Pump Group 200 PSI
No Heat 3 St Vac..................................... 5-11
Pump Group 200 PSI
With Heat 7.2 3 St Vac. ........................... 5-13
Recovery Tank Group-2 St......................... 5-15
Recovery Tank Group-3 St......................... 5-17
Recovery Tank Group- 2 St With Heat....... 5-19
Recovery Tank Group-3 St With Heat........ 5-21
Vacuum Group-2 St.................................... 5-23
Vacuum Group-3 St.................................... 5-25
Vacuum Group-7.2-3 St.............................. 5-27
Heater Group…………………………………5-29
Tank & Lid Group........................................ 5-31
Label and Strap Group ............................... 5-33
Wiring Group 100-PSI 2 St Vac.................. 5-35
Wiring Group 100-PSI 3 St Vac.................. 5-36
Wiring Group 200 PSI 3 St Vac.................. 5-37
Wiring Group 200 PSI-7.2-3 St Vac............ 5-38
Wiring Group Heater................................... 5-39
Notes .......................................................... 5-40
Warranty...........................................……...5-41
CHEYENNE 86038850 03/08/07
3
Page 4
HOW TO USE THIS MANUAL
This manual contains the following sections:
- HOW TO USE THIS MANUAL
- SAFETY
- OPERATIONS
- MAINTENANCE
- PARTS LIST
The HOW TO USE THIS MANUAL section will tell you how to find important information for ordering correct repair parts.
Parts may be ordered from authorized dealers. When placing an order for parts, the machine model and machine serial number are important. Refer to the MACHINE DATA box which is filled out during the installation of your machine. The MACHINE DATA box is located on the inside of the front cover of this manual.
MODEL _____________________________________ DATE OF PURCHASE ________________________ SERIAL NUMBER ____________________________ SALES REPRESENTATIVE # ___________________ DEALER NAME ______________________________ OPERATIONS GUIDE NUMBER __________________
PUBLISHED ________________________________
The model and serial number of your machine is located on the inner wall of solution tank, above the pump.
1-1
CHEYENNE 86038850 03/08/07
The SAFETY section contains important information regarding hazard or unsafe practices of the machine. Levels of hazards is identified that could result in product or personal injury, or severe injury resulting in death.
The OPERATIONS section is to familiarize the operator with the operation and function of the machine.
The MAINTENANCE section contains preventive maintenance to keep the machine and its components in good working condition.
The PARTS LIST section contains assembled parts illustrations and corresponding parts list. The parts lists include a number of columns of information:
- REF – column refers to the reference number on the parts illustration.
- PART NO. – column lists the part number for the part.
- PRV NO. – reference number.
- QTY – column lists the quantity of the
part used in that area of the machine.
- DESCRIPTION – column is a brief description of the part.
- SERIAL NO. FROM – column indicates the first machine the part number is applicable to. When the machine design has changed, this column will indicate serial number of applicable machine. The main illustration shows the most current design of the machine. The boxed illustrations show older designs. If column has an asterisk (*), call manufacturer for serial number.
- NOTES – column for information not noted by the other columns.
NOTE: If a service or option kit is installed on your machine, be sure to keep the KIT INSTRUCTIONS which came with the kit. It contains replacement parts numbers needed for ordering future parts.
Page 5
IMPORTANT SAFETY INSTRUCTIONS
!
When using an electrical appliance, basic precaution
must always be followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE.
WARNING:
To reduce the risk of fire, electric shock, or injury:
Use only indoors. Do not use outdoors or expose to rain. Use only as described in this manual. Use only manufacturer’s recommended components and attachments.
If the machine is not working properly, has been dropped, damaged, left outdoors, or dropped into water, return it to an authorized service center.
Do not operate the machine with any openings blocked. Keep openings free of debris that may reduce airflow. This machine is not suitable for picking up hazardous dust. Machine can cause a fire when operating near flammable vapors or materials. Do not operate this machine near
flammable fluids, dust or vapors.
This machine is suitable for commercial use, for example in hotels, schools, hospitals, factories, shops and offices for more than normal housekeeping purposes.
Maintenance and repairs must be done by qualified personnel. During operation, attention shall be paid to other persons, especially children. When leaving unattended, secure against unintentional movement. The machine shall only be operated by instructed and authorized persons. When leaving unattended, switch off or lock the main power switch to prevent unauthorized use. Do not handle the plug or machine with wet hands. Do not unplug machine by pulling on cord. To unplug, grasp the plug, not Do not use with damaged cord or plug. Follow all instructions in this manual concerning grounding the ma chine. Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or
corners. Do not pull/run machine over cord. Keep cord away from heated surfaces. Connect to a properly grounded outlet. See Grounding Instructions.
the cord.
SAVE THESE INSTRUCTIONS
CHEYENNE 86038850 03/08/07
2-1
Page 6
HAZARD INTENSITY LEVEL
The following symbols are used throughout this guide as indicated in their descriptions:
HAZARD INTENSITY LEVEL
There are three levels of hazard intensity identified by signal words -WARNING and CAUTION and FOR SAFETY. The level of hazard intensity is determined by the following definitions:
! WARNING
WARNING - Hazards or unsafe practices which COULD result in severe personal injury or death.
! CAUTION
CAUTION - Hazards or unsafe practices which could result in minor personal injury or product or property
damage. FOR SAFETY: To Identify actions which must be followed for safe operation of equipment.
Report machine damage or faulty operation immediately. Do not use the machine if it is not in proper operating condition. Following is information that signals some potentially dangerous conditions to the operator or the equipment. Read this information carefully. Know when these conditions can exist. Locate all safety devices on the machine. Please take the necessary steps to train the machine operating personnel.
FOR SAFETY:
DO NOT OPERATE MACHINE: Unless Trained and Authorized. Unless Operation Guide is Read and understood. In Flammable or Explosive areas. In areas with possible falling objects.
WHEN SERVICING MACHINE: Avoid moving parts. Do not wear loose clothing; jackets, shirts, or sleeves when working on the machine. Use manufacturer approved replacement parts.
2-2
CHEYENNE 86038850 03/08/07
Page 7
GROUNDING INSTRUCTIONS
3
THIS PRODUCT IS FOR COMMERCIAL USE ONLY.
ELECTRICAL:
In the USA this machine operates on a standard 15 amp 115V, 60 hz, A.C. power circuit . The amp, hertz, and voltage are listed on the data label found on each machine. Using voltages above or below those indicated on the data label will cause serious damage to the motors.
EXTENSION CORDS:
If an extension cord is used, the wire size must be at least one size larger than the power cord on the machine, and must be limited to 50 feet (15.5m) in length.
GROUNDING INSTRUCTIONS:
This appliance must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and grounding plug. The plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
This appliance is for use on a nominal 120-volt circuit, and has a grounded plug that looks like the plug in “Fig. A”. A temporary adaptor that looks like the adaptor in “Fig . C” may be used to connect this plug to a 2-pole receptacle as shown in “Fig. B”, if a properly grounded outlet is not available. The temporary adaptor should be used only until a properly grounded outlet (Fig. A) can be installed by a qualified electrician. The green colored rigid ear, lug, or wire extending from the adaptor must be connected to a permanent ground such as a properly grounded outlet box cover. Whenever the adaptor is used, it must be held in place by a metal screw.
CHEYENNE 86038850 03/08/07
Improper connection of the equipment­grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
2-
Page 8
TECHNICAL SPECIFICATIONS
ITEM DIMENSION/CAPACITY
Electrical 115V 60Hz Electric Vacuum Motor DUAL 2 STAGE (C2, C2H) DUAL 3 STAGE (C3, C3HP, CHPH) Solution Pump 100PSI (C2, C3, C2H) 200PSI (C3HP, CHPH) Solution Capacity 16 gal. (60.6L) Recovery Capacity 16 gal. (60.6L) Dimensions – Weight (Empty) 98 lbs. (44.5kgs) Dimensions - Length 29 in. (73.6cm) Dimensions - Height 36 in. (91.4cm) Dimensions - Width 21 in. (53.3cm) Power Cable 25 ft. (7.6m)
3-1
10/29/01
CHEYENNE 86038850 03/08/07
Page 9
t
t
k
Vacuum Inle
Solution Outle
Heat Models
ONLY
Mounted next to valve control on manifold plate, located to rear of machine.
Solution and Vacuum
Tank Lid
CONTROLS
Water Pump
Vacuum
Cheyenne HP
ONLY
Water Pump
Vacuum #2
Vacuum #1
Vacuum Tank
Solution Tan
Heater
(Optional Accessory)
Base Assembly
Optional Equipment:
86000600 – PRV NO. 89226 Deluxe Professional Wand 86260790 – PRV NO. 39604 Hose Asm, 2” Vac/Sol 25ft
CHEYENNE 86038850 03/08/07
3-2
Page 10
MACHINE OPERATIONS
PRE-RUN INSPECTION
1. Check all fittings and connectors for proper assembly.
2. Check all hoses for leaks. Repair or replace any damaged hoses.
3. Check power cord(s) for any damage. If damaged, replace.
EQUIPMENT SET-UP
1. Plug power cord from machine into properly grounded wall outlet.
2. Turn vacuum motor switch on and off to make sure there is electrical power at machine.
3. Connect vac hose to machine. Slide the swivel cuff over the outlet on the tank.
4. Connect the hose to your machine and wand. Pull back the knurled collar on the quick
disconnect coupler and push onto the connection on the chassis. To avoid leaks, check to be that a positive connection was made.
5. Pour clean, hot water into the solution tank.
To avoid possible tank distortion, water temperature must not exceed 140 F (60C).
6. Add a non-foaming cleaning solution concentrate, for use in hot water extractors at the proportions noted on the container (See list below), into solution tank.
7. Turn pump and vacuum switch(s) to the on position.
8. Start cleaning.
WARNING
!
To prevent possible disease hazard, before attempting to clean bodily fluids spills, you must kill any viruses, germs or bacteria present in the bodily fluid. SUITABLE INCOMPATIBLE CHEMICALS CHEMICALS
Alkalis Aldehydes Clorox II Bleach* Aromatic Hydrocarbons Defoaming Agents Butyls Detergents Carbon Tetrachloride Hydroxides Clorox* Oxygen Bleaches Chlorinate d Bleaches Soaps Chlorinated Hydrocarbons
Sta-Puf Fabric
Softener* Lysol* Vinegar Methyls (MEK)
Perchlorethylene (perc)
Phenols Trichlorethylene
*Registered Trademark
D-Limonene
CLEANING & EMPTYING TANKS
WARNING
!
Always use defoamer if foaming occurs. Foam will suspend large particles which may damage vacuum as well as allow liquid into the vacuum motor without activating the float shutoff.
1. Before proceeding, make certain that the nozzle is functioning properly. a. To check, hold the wand about one foot
above the surface to be cleaned and open the wand valve. A full spray should be observed from the nozzle.
b. If the nozzle is not showing a full spray
pattern, adjust nozzle for proper pattern, clean, or replace nozzle.
2. Normally, chemical is applied on the push stroke while vacuuming is done on the pull stroke. For heavily soiled carpets the hand tool may be used in the scrubbing manner, applying chemical in both the push and pull stroke.
A
LWAYS FINISH UP AN AREA WITH A VACUUM PULL
STROKE
3. When cleaning, keep the working opening (wand mouth) flat on the surface being cleaned. Keep the wand moving when the valve is open.
4. The shutoff float inside the recovery tank will impede the vacuum flow when the tank is full. When this occurs, empty the recovery tank. Do this by opening the dump valve located at the back of the machine. NOTE: Dispose of waste in
a proper manner which would not violate any Local, State or Federal law.
.
5. Once the recovery tank has been emptied, you
may once again proceed with cleaning
CAUTION
!
Operating Vacuum after shutoff has activated could draw water directly into the vac motor. This will cause damage to the motor, therefore voiding your warranty.
CAUTION
!
A
LWAYS TEST CARPET FOR COLOR FASTNESS IN AN
INCONSPICUOUS PLACE
drying times, do not spray too much solution in any one area.
WARNING
!
Before making any adjustments or performing any maintenance to your machine, disconnect the power cord from the electrical source.
. Also, to avoid prolonged
3-3
CHEYENNE 86038850 03/08/07
Page 11
SHUT DOWN AND STORAGE
1. Turn Switch OFF. Empty recovery tank
completely and rinse several times to remove any dirt or debris that may be left behind.
2. Drain any unused cleaning solution fro m solution tank and rinse with clean water to remove any suds left behind by the cleaning chemicals.
NOTE: Dispose of waste in a proper manner which would not violate any Local, State or Federal law
3. Run a small amount of clean water through pump if chemicals were used. This will help insure the life of your pump.
4. Check the spray jet on the cleaning tool for full spray pattern and inspect vac head for any obstructions.
5. Remove as much moisture from system before storing in cold climates. Excess water may freeze during storage and crack internal components, causing damage to the unit.
MACHINE OPERATIONS
CHEYENNE 86038850 03/08/07
3-4
Page 12
MAINTENANCE
DAILY MAINTENANCE
Unplug power cord(s) before servicing or making any repairs.
1. Flush the entire system, including floor tool, hand tool, etc., with 1 to 3 gallons of clean, hot water.
2. Vacuum out the solution tank.
3. Rinse tank with fresh water. Periodically inspect the recovery tank and decontaminate if necessary, using a Hospital Grade Virucide or a 1-10 bleach to water solution. Wastewater should be disposed of properly.
4. Occasionally check filter screen at the bottom of the solution tank and rinse clean with hot water if necessary.
5. Inspect hoses for wear. Frayed or cracked hoses should be replaced to avoid vacuum or solution pressure loss.
6. Inspect power cord for wear or damage. This cable will lie on wet carpet. To prevent electrical shock replace cords that are frayed or have cracked insulation immediately.
7. Clean all dirt and obstructions from drain valve and gaskets to prevent possible leakage and premature wear.
8. Run clean water through solution pump whe n work is complete.
9. Empty both tanks and rinse, run vacuum (s) for at least one minute to dry motor(s).
10. Store with access covers removed to allow tanks to dry.
PERIODIC MAINTENANCE
1. Twice a month, flush a white vinegar solution
(one quart vinegar to two gallons water) or anti­browning solution (mixed as directed) through the extractor. This will prevent build-up of alkaline residue in the system.
2. If spray jet becomes clogged, remove the spray tip, wash it thoroughly, and blow dry. NOTE: D
NOT USE PINS THIS COULD DESTROY THE SPRAY PATTERN
3. Apply silicone lubricant to solution nipple.
4. Periodically inspect all hoses, electrical cable
and connections on your machine. Frayed or cracked hoses should be repaired or replaced to eliminate vacuum or solution pressure loss. If the cable insulation on the power cord is broken or frayed, repair or replace immediately. Don’t take chances with electrical fire or shock.
5. Clean outside of all tanks and check for damage.
, WIRE, ETC. TO CLEAN NOZZLE AS
O
.
4-1
CHEYENNE 86038850 03/08/07
MONTHLY MAINTENANCE
1. Check all bearings for noise and wear.
2. Check all gaskets for wear and leakage.
3. Check pump pressure; observe spray pattern and check gauge if necessary.
4. Check overall performance of machine.
SEMI-ANNUALLY
Check vacuum motor brushes.
1.
LUBRICATION
For hose fitting lubrication, use a light silicone lubricant which will not damage o-rings.
STORAGE
Thoroughly clean machine if it is to be stored. Protect this machine from freezing while in storage.
Page 13
2
Only qualified maintenance personnel are to perform the following repairs.
SOLUTION PUMP REPLACEMENT
1. Turn off all switches and unplug the machine.
2. Tip recovery tank to gain access to solution
tank.
3. Remove solution hoses from fittings on pump. Disconnect wires.
4. Remove the screws that fasten the pump to the frame.
5. Reverse process to install new replacement pump.
VACUUM MOTOR REPLACEMENT
1. Turn off all switches and unplug machine.
2. Tip recovery tank to expose vacuum (s).
3. Locate the proper vacuum motor wires and
disconnect.
4. Unfasten screws holding vacuum to vac plate. Remove the vacuum motor.
5. Reverse process to install vacuum motor replacement.
Vacuum Motor Carbon Brushes Replacement (Windsor)
End Cap
Carbon Brushes
WARNING: The green ground wire must be attached for safe operation. See wiring diagram.
MAINTENANCE
Vacuum Motor Carbon Brushes Replacement (Ametek)
End Cap
Carbon Brushes
Note: When replacing carbon brushes loosen wire terminal BEFORE removing screws on bracket.
If armature commutator is grooved, extremely pitted or not concentric, the motor will need to be replaced or sent to a qualified service center.
WARNING: The green ground wire must be attached for safe operation. See wiring diagram.
Wire
Terminal
Note: Place stop in groove.
Wire Terminal
If armature commutator is grooved, extremely pitted or not concentric, the motor will need to be replaced or sent to a qualified service center.
Important: These brushes wear quicker as the length shortens due to increased heat. Spring inside brush housing will dama ge motor if brushes are allowed to wear away completely.
3
[9.5mm]
8
Periodically check the length of the carbon brushes. Replace both carbon brushes when either is less than 3/8" (9.5mm) long.
CHEYENNE 86038850 03/08/07
Important: These brushes wear quicker as the length shortens due to increased heat. Spring inside brush housing will dama ge motor if brushes are allowed to wear away completely.
3/8 (9.5mm)
Periodically check the length of the carbon brushes. Replace both carbon brushes when either is less than 3/8" (9.5mm) long.
4-
Page 14
MAINTENANCE
PUMP REPLACEMENT PARTS FOR SHURFLO 100 PSI (250-64A)
86161980 – PRV NO. 250-67 Switch Asm
Pump Head Replacement
86251040
PUMP REPLACEMENT PARTS FOR FLOJET 100 PSI 86251110 – PRV NO. (65219)
PRV NO. 65187
Bypass Valve Asm
86258830
PRV NO. 84161
DIAPHRAGM
86235120
PRV NO. 29219
Diaphragm
86235100
PRV NO. 29206
86251090
PRV NO. 65204
PUMP HEAD
86258860
PRV NO. 84166
VALVE ASM
86247360
PRV NO. 53245
MOTOR
PUMP REPLACEMENT KITS 200 PSI PUMPTEC
CAM & BEARING KIT 86201170 PRV NO. 250-79G
4-3
PLUNGER & SEALS KIT 86201150 PRV NO. 250-79E
CHEYENNE 86038850 03/08/07
VALVE & O-RINGS KIT 86201160 PRV NO. 250-79F
Page 15
MAINTENANCE
4
PRESSURE REGULATOR
For best results with the pressure regulator, we recommend that you clean and lubricate the piston and u-cup with Superlube lubricant monthly or when pressure drop seems excessive.
1. Turn unit off before lubricating.
2. Remove cap, spring and spring retainer plate.
3. With fingertips remove piston and u-cup.
4. Wipe piston and u-cup clean of any film or scale.
5. Lubricate the piston and u-cup with Superlube.
6. Reassemble regulator.
7. With pump ON, re-adjust pressure regulator for normal operation.
LUBRICATE U-CUP WITH SUPERLUBE MONTHLY.
OUT
IN
U-CUP
PISTON
SPRING RETAINER PLATE
SPRING
(GOLD - 125 PSI)
CAP
(GREEN - 200 PSI)
CHEYENNE 86038850 03/08/07
4-
Page 16
TROUBLESHOOTING
PROBLEM CAUSE SOLUTION
Loss of Power
Electrical shock
Vac motor speed varies or doesn’t run
Loss of vacuum
Pump runs no solution
Pump runs, loss of pressure
Pump will not run Solution hose fitting hard
to connect Carpet not getting clean Severe soil conditions
Carpet too wet Over saturation
Carpet browning
Solution not flowing properly
Dead electrical circuit Check building circuit breaker or fuse box. Faulty power cord Replace
Equipment not grounding Follow grounding instructions exactly Receptacle not grounded Contact an electrician to check building’s wiring
Internal wiring problem Worn motor brushes Replace
Motor worn out Replace Faulty switch Replace Loose vacuum dome Center and seal dome over tank Crack in dome of poor joint Replace or repair using acrylic plastic cement only Lint or dirt clogging vacuum screen Loose cuffs on vacuum hose Vac motor seals leaking Replace Floor tool vac chamber clogged Vac motor, hose, or dome gasket Pump inlet screen plugged Clean inlet screen
Pump air locked Internal or external
solution line damaged and leaking Internal pump components wearing out Check BPR for particles or cuts in seals Unit not plugged in Connect unit to 3 prong grounded outlet Loose wiring See dealer
Corrosion on fittings.
Leaving carpet too wet Check for loss of vac pressure Too much chemical Check label for correct solution concentration Light carpet with no brown prevention Solution hose connection Check for positive connection Faulty pump Repair or replace Faulty floor tool valve Repair or replace Faulty pump switch Repair
Have a trained service technician check machine’s wiring
With power off clean screen Tighten cuffs turning counterclockwise
Wash out with hose. Pick lint out with a wire Replace
Press trigger to open valve on cleaning wand to relieve air
Replace
Replace, see pump kit components (Pg 4-3) Take piston from BPR and lubricate with Superlube.
If problem still exists change BPR.
Clean with steel wool. Soak in acetic acid (white vinegar). Lubricate lightly with silicone base lubricant. Make several passes at right angles to each other. Use a pre-spray. Check solution wand. Make several passes without spray
Go over carpet with browning prevent only
4-5
CHEYENNE 86038850 03/08/07
Page 17
6
THIS PAGE LEFT BLANK INTENTIONALLY
CHEYENNE 86038850 03/08/07
4-
Page 18
BASE GROUP PARTS
6
7 5
9
1
4
5
6
2
8
7
8
6
3
5-1
CHEYENNE 86038850 03/08/07
Page 19
BASE PARTS LIST
REF PART NO. PRV NO. QTY DESCRIPTION
1 86010710 87080 2 WASHER, .5 X 1.25 FLAT GR8 PLT 2 86103460 57196 2 NUT, 1/2 PUSH-ON DOME CAP 3 86202250 040-06 2 WHEEL 8” BLK CENTERED HUB 4 86010760 87142 2 WASHER, .344 X .69 X .066 FLAT PLT 5 86279130 87083 6 WASHER, 5/16 SPLIT LOCK PLTD 6 86006760 70305 4 SCR, 5/16-18 X 3/4 HHCS 7 86199430 040-03 2 CASTER SWIVEL 4” 8 86270830 57023 2 NUT, 5/16-18 HEX NYLOCK SS 9 86042310 56-502218 1 BASE ASM, CHEYENNE
SERIAL NO.
FROM
NOTES:
CHEYENNE 86038850 03/08/07
5-2
Page 20
SOLUTION TANK GROUP
19
1
17
16
15
14
13
12
18
11
3
2
4
5
6
5-3
7
10
9
CHEYENNE 86038850 03/08/07
Page 21
SOLUTION TANK PARTS LIST
REF PART NO. PRV NO. QTY DESCRIPTION
1 86064530 43-807527 1 SPLASH SHIELD 2 86005720 57106 2 NUT, 8-32 W/ STAR WASHER PLTD 3 86042400 56-502126 1 NIPPLE ASSEMBLY, QD MOUNT 4 86197370 31017 1 ELBOW, 1/4 FPT X 1/4 FPT 5 86161650 39598 1 HOSE, HP 42. 1/4MPT X 1/4MPT 6 86027130 75376 1 TANK SOLUTION 7 86240490 40094 2 HOSEBARB, 1/4MPT X 3/8 NYLON 8 - OPEN - -
9 86192840 290-08 1 STRAINER, 1/4 NPT 50 MESH 10 86197940 40027 1 HOSEBARB, 3/8MPT X 1/2 90D DL 11 86197940 70744 4 SCR, 1/4-20 X 1 PFH BLK SS 12 86199970 120-08 1 HANDLE, MACHINE BLACK 13 86279610 87190 4 WASHER, SEAL 5/8 OD NEOPRENE 14 86005810 57245 4 NUT, 1/4-20 HEX NYLOCK SS 15 86005580 56012 1 NIPPLE, 1/4 FPT QD 16 86020650 70051 2 SCR, 8-32 X 1/2 PPHMS NP 17 86161800 46-802531 1 LATCH, CONCEALED KEEPER 18 86161960 70222 3 SCR, #8 X 1/2 PPHST BLK 19 86279190 87095 3 WASHER, #10 FLAT PLTD
SERIAL NO.
FROM
NOTES:
CHEYENNE 86038850 03/08/07
5-4
Page 22
PUMP GROUP
O
)
100 PSI NO HEAT 2 ST VAC
22
23
21
20
24A
11
10
9
24B
13
1
2
3
4
7
8
3
15
16
14
13
TO SOLUTION TANK UPPER SPIN FITTING (86197630, PRV NO. 40042)
TO SOLUTION TANK (86197550, PRV N
. 40014
5-5
CHEYENNE 86038850 03/08/07
Page 23
PUMP PARTS LIST
100 PSI NO HEAT
2 ST VAC
REF PART NO. PRV NO. QTY DESCRIPTION
1 86042450 62966 1 PLATE, MANIFOLD
2 86272730 66017 2 PLUG, 1/4 BASS PIPE
3 86002750 70088 1 SCR, 10-32 X 1/2 PPHMS SS
4 86000950 70532 2 SCR, 10-32 X 1/2 PPHMS BLK
5 86199540 060-04A 1 CORD ASM, 14/3 SJT X 25’ BLK
6 86256240 73505 1 STRAIN RELIEF, 1/2 NPT TRUMPET
7 86199310 110-14 1 CAP PLUG 7/8”
8 86005670 57040 1 NUT, 1/2 NPT CONDUIT
9 86162060 84197 1 VALVE, BPR 125 PSI BRASS 1000132734 10 86072720 14454 1 BRKT, VALVE 11 86005700 57104 2 NUT, 10-32 W/STAR WASHER PLTD 12 86164130 82859 1 HOSE, 1/2 NYLOBRAID 20” 13 86222770 20042 6 CLAMP, 3/8 HOSE (D-SLOT) 14 86280970 39233 1 HOSE 3/8 RUBBER X 17” 15 86270990 57090 2 NUT, 10-32 NYLOCK SS 16 86278980 87014 2 WASHER, #8 INT. STAR 17 86001550 40043 2 HOSEBARB, 3/8MPT X 3/8 90D 18 86276240 70614 2 SCR, 10-32 X 1 1/8 PPHMS SS 19 - OPEN - - 20 86280800 39031 1 HOSE, 3/8 RUBBER X 24” 21 86197560 40015 1 HOSEBARB, 1/4FPT X 3/8 22 86246850 54182 1 MANIFOLD, ASM 23 86279530 87173 1 WASHER, .765 ID X 1.31 OD X .09 T
24A 86201430 250-64A 1 SHURFLO 100 PSI PUMP DEMAND 24B 86251110 65219 1 PUMP, 115V 100PSI BYPASS W/SW (FLOJET)
SERIAL NO.
FROM
NOTES:
CHEYENNE 86038850 03/08/07
5-6
Page 24
PUMP GROUP 100 PSI NO HEAT 3 ST VAC
21
22
1
2
3
4
16
17
15
23A 23B
16
19
12
11
20
10
12
5
6
4
9
8
7
TO SOLUTION TANK UPPER SPIN FITTING (86197630, PRV NO. 40042)
14
5-7
13
CHEYENNE 86038850 03/08/07
TO SOLUTION TANK (86197550, PRV NO.
40014)
12
Page 25
PUMP PARTS LIST
8
100 PSI NO HEAT
3 ST VAC
REF PART NO. PRV NO. QTY DESCRIPTION
1 86042450 62966 1 PLATE, MANIFOLD
2 86272730 66017 2 PLUG, 1/4 BASS PIPE
3 86002750 70088 1 SCR, 10-32 X 1/2 PPHMS SS
4 86006950 70532 4 SCR, 10-32 X 1/2 PPHMS BLK
5 86199540 060-04A 2 CORD ASM, 14/3 SJT X 25’ BLK
6 86256240 73505 2 STRAIN RELIEF, 1/2 NPT TRUMPET
7 86005670 57040 2 NUT, 1/2 NPT CONDUIT
8 86162060 84197 1 VALVE, BPR 125 PSI BRASS 1000132734
9 86072720 14454 1 BRKT, VALVE 10 86005700 57104 2 NUT, 10-32 W/STAR WASHER PLTD 11 86282720 82859 1 HOSE, 1/2 NYLOBRAID 20” 12 86222770 20042 6 CLAMP, 3/8 HOSE (D-SLOT) 13 86280970 39233 1 HOSE 3/8 RUBBER X 17” 14 86270990 57090 2 NUT, 10-32 NYLOCK SS 15 86278980 87014 2 WASHER, #8 INT. STAR 16 86001550 40043 2 HOSEBARB, 3/8MPT X 3/8 90D 17 86276240 70614 2 SCR, 10-32 X 1 1/8 PPHMS SS 18 - OPEN - - 19 86280800 39031 1 HOSE, 3/8 RUBBER X 24” 20 86197560 40015 1 HOSEBARB, 1/4FPT X 3/8 21 83246850 54182 1 MANIFOLD, ASM 22 86279530 87173 1 WASHER, .765 ID X 1.31 OD X .09 T
23A 86201430 250-64A 1 SHURFLO 100 PSI PUMP DEMAND 23B 86251110 65219 1 PUMP, 115V 100PSI BYPASS W/SW (FLOJET)
SERIAL NO.
FROM
NOTES:
CHEYENNE 86038850 03/08/07
5-
Page 26
PUMP GROUP 100 PSI WITH HEAT 2 ST VAC
25A 25B
18
21
14
22
12
11
23
10
1
9
3
2
4
5
6
8
7
5
18
16
19
17
13
14
15
TO SOLUTION TANK UPPER SPIN FITTING (86197630 ­PRV NO. 40042)
TO SOLUTION TANK (86197550 ­PRV NO. 40014)
14
5-9
CHEYENNE 86038850 03/08/07
Page 27
PUMP PARTS LIST
100 PSI WITH HEAT
2 ST VAC
REF PART NO. PRV NO. QTY DESCRIPTION
1 86042450 62966 1 PLATE, MANIFOLD
2 86005590 56014 2 NIPPLE, 1/4 CLOSE
3 86005580 56012 2 NIPPLE, 1/4 FPT QD
4 86161770 500452 1 LABEL, HEATER
5 86006950 70532 4 SCR, 10-32 X 1/2 PPHMS BLK
6 86199540 060-04A 1 CORD ASM, 14/3 SJT X 25’ BLK
7 86256240 73505 1 STRAIN RELIEF, 1/2 NPT TRUMPET
8 86199310 110-14 1 CAP PLUG 7/8”
9 86005670 57040 1 NUT, 1/2 NPT CONDUIT 10 86162060 84197 1 VALVE, BPR 125 PSI BRASS 1000132734 11 86072720 14454 1 BRKT, VALVE 12 86005700 57104 2 NUT, 10-32 W/STAR WASHER PLTD 13 86164130 82859 1 HOSE, 1/2 NYLOBRAID 20” 14 86222770 20042 6 CLAMP, 3/8 HOSE (D-SLOT) 15 86280970 39233 1 HOSE 3/8 RUBBER X 17” 16 86270990 57090 2 NUT, 10-32 NYLOCK SS 17 86278980 87014 2 WASHER, #8 INT. STAR 18 86001550 40043 2 HOSEBARB, 3/8MPT X 3/8 90D 19 86276240 70614 2 SCR, 10-32 X 1 1/8 PPHMS SS 20 - OPEN - - 21 86280800 39031 1 HOSE, 3/8 RUBBER X 24” 22 86157620 40015 1 HOSEBARB, 1/4FPT X 3/8 23 86248650 54182 1 MANIFOLD, ASM 24 86279530 87173 1 WASHER, .765 ID X 1.31 OD X .09 T
25A 86201430 250-64A 1 SHURFLO 100PSI PUMP DEMAND 25B 86251110 65219 1 PUMP, 115V 100PSI BYPASS W/SW (FLOJET)
SERIAL NO.
FROM
NOTES:
CHEYENNE 86038850 03/08/07
5-10
Page 28
PUMP GROUP 200 PSI NO HEAT 3 ST VAC
ITE M 1 0
1
2
23
24
12
13
11
25
14
SOLUTION TANK
18
17
28
13
3
5
4
6
7
9
8
15
4
20
18
5-11
19
27
22 21
CHEYENNE 86038850 03/08/07
16
(TO SOLUTION TANK STRAINER)
Page 29
PUMP PARTS LIST
2
200 PSI NO HEAT
REF PART NO. PRV NO. QTY DESCRIPTION
1 86042460 62967 1 PLATE, MANIFOLD HP
2 86272730 66017 2 PLUG, 1/4 BRASS PIPE
3 86006590 70088 1 SCR, 10-32 X 1/2 PPHMS SS
4 86006950 70532 2 SCR, 10-32 X 1/2 PPHMS BLK NP
5 86199540 060-04A 2 CORD ASM, 14/3 SJT X 25’ BLK
6 86256240 73505 2 STRAIN RELIEF, 1/2 NPT TRUMPET
7 86200970 190-07 1 PRESSURE GAUGE 1000 PSI
8 86197370 31017 1 ELBOW, 1/4FPT X 1/4FPT
9 86005670 57040 2 NUT, 1/2 NPT CONDUIT 10 86286040 84182 1 VALVE BPR 200 PSI 11 86005700 57104 2 NUT, 10-32 W/STAR WASHER PLTD
12 86072720 14454 1 BRKT, VALVE 13 86233150 20042 4 CLAMP, 3/8 HOSE (D-SLOT) 14 86282720 82859 1 HOSE, 1/2 NYLOBRAID X 20” 15 86161640 39597 1 HOSE, HP 15.0 1/4MPT X 1/4MPT 16 86280810 39032 1 HOSE, 3/8 RUBBER X 15” 17 86197220 40014 1 HOSEBARB, 1/4 MPT X 3/8 DL 18 86199640 030-16 2 ELBOW, 1/4 NPT STREET LONG 90D 19 86200150 151-38D 1 HOSE, PULSE 27.0 1/4 MPTX1/4MPT 20 86272730 66017 1 PLUG, 1/4 BRASS PIPE 21 86010650 87018 2 WASHER, #10 X 9/16 OD 22 86276240 70614 2 SCR, 10-32 X 1 1/8 PPHMS SS 23 86201130 250-79 1 PUMPTEC 200PSI PUMP & MOTOR 24 86197350 22014 1 COUPLER, 1/4F HEX 25 86246850 54182 1 MANIFOLD, ASM 26 86279530 87173 1 WASHER, .765ID X 1.31OD X .09T SS 27 86270990 57090 2 NUT, 10-32 HEX NYLOCK SS 28 86162070 84198 1 VALVE, BPR 200 PSI BRASS
SERIAL NO.
FROM
INCLUDES
NOTES:
62967
3 ST VAC
CHEYENNE 86038850 03/08/07
5-1
Page 30
PUMP GROUP 200 PSI WITH HEAT
7.2 3 ST VAC
ITEM 1 1
25
26
13
15
12
27
14
SOLUTION TANK
17
1
2
3
4
28
6
8
10
5
29
7
8
9
30
16
18
5-13
17
22
21
20
24 23
CHEYENNE 86038850 03/08/07
14
19
(TO SOLUTION TANK STRAINER)
Page 31
PUMP PARTS LIST
4
200 PSI WITH HEAT
7.2 3 ST VAC
REF PART NO. PRV NO. QTY DESCRIPTION
1 86042460 62967 1 PLATE, MANIFOLD HP
2 86005590 56014 2 NIPPLE, 1/4 CLOSE
3 86005580 56012 2 NIPPLE, 1/4 FPT QD
4 86161770 500452 1 LABEL HEATER
5 86199310 110-14 1 CAP PLUG 7/8”
6 86199530 060-04 1 CORD ASM, 12/ SJT X 25’ BLK
7 86200970 190-07 1 PRESSURE GAUGE 1000PSI
8 86006950 70532 4 SCR, 10-32 X 1/2 PPHMS BLK NP
9 86197370 31017 1 ELBOW, 1/4FPT X 1/4FPT 10 86005670 57040 1 NUT, 1/2 NPT CONDUIT 11 86286040 84182 1 VALVE, BPR 200 PSI INCLUDES 62967 12 86072720 14454 1 BRKT, VALVE 13 86005700 57104 2 NUT, 10-32 W/STAR WASHER PLTD 14 86233150 20042 4 CLAMP, 3/8 HOSE (D-SLOT) 15 86222770 82859 1 HOSE, 1/2 NYLOBRAID X 20” 16 86161640 39597 1 HOSE, HP 15.0 1/4MPT X 1/4MPT
17 86199640 030-16 2 18 86156850 40014 1 HOSEBARB, 1/4MPT X 3/8 DL
19 86280810 39032 1 HOSE, 3/8 RUBBER X 15” 20 86270990 57090 2 NUT, 10-32 HEX NYLOCK SS
21 86200150 151-38D 1 22 86272730 66017 1 PLUG, 1/4 BRASS PIPE
23 86010650 87018 2 WASHER, #10 X 9/16 OD 24 86276240 70614 2 SCR, 10-32 X 1 1/8 PPHMS SS 25 86201130 250-79 1 PUMPTEC 200PSI PUMP & MOTOR 26 86197350 22014 1 COUPLER, 1/4F HEX 27 86246850 54182 1 MANIFOLD, ASM 28 86279530 87173 1 WASHER, .765ID X 1.31OD X .09T 29 86256240 73505 1 STRAIN RELIEF, 1/2 NPT TRUMPET 30 86162070 84198 1 VALVE, BPR 200 PSI BRASS
ELBOW, 1/4 NPT STREET LONG 90D
HOSE, PULSE 27.0 1/4MPT X 1/4MPT
SERIAL NO.
FROM
NOTES:
CHEYENNE 86038850 03/08/07
5-1
Page 32
RECOVERY TANK-2 STAGE GROUP
10
13
9
11
8
12
2
1
11
3
4
5
6
5-15
7
CHEYENNE 86038850 03/08/07
Page 33
RECOVERY TANK-2 STAGE PARTS LIST
REF PART NO. PRV NO. QTY DESCRIPTION
1 86161910 48-941382 1 PLATE, SWITCH MODEL 2
2 86162010 32-900195 3 SWITCH, DPST, LIGHTED ROCKER
3 86043410 56-502173 1 ASSY, EXH DCT FLNG PRT405
4 86275210 70384 4 SCR, 1/4-20 X 1/2 PHTR BLK
5 86161470 11-800444 1 ELBOW, 2” 45D PVC SCH40
6 86161460 15-808123 1 DUMP VALVE, 2’
7 86237770 35256 1 GASKET, DUMP VALVE
8 86033320 78474 1 VAC STACK ASM, 6 GAL PORTABLE
9 86161510 43-807109 1 GASKET, VAC TANK 10 86161820 56-502156 1 LID, VACUUM TANK 11 86161960 70222 6 SCR, #8 X 1/2 PPHST BLK 12 86199840 090-12A 1 FLOAT CAGE ASSY COMPLETE 13 86242230 500009 1 LABEL, WARNING
SERIAL NO.
FROM
NOTES:
CHEYENNE 86038850 03/08/07
5-16
Page 34
RECOVERY TANK-3 STAGE GROUP
2
11
13
10
12
1
11
3
4
5
9
8
6
7
5-17
CHEYENNE 86038850 03/08/07
Page 35
RECOVERY TANK-3 STAGE PARTS LIST
REF PART NO. PART NO. QTY DESCRIPTION
1 86161920 48-941383 1 PLATE, SWITCH MODEL 2
2 86162010 32-900195 3 SWITCH, DPST, LIGHTED ROCKER
3 86042360 56-502143 1 BRKT, CORD WRAP NO HEATER
4 86275210 70384 4 SCR, 1/4-20 X 1/2 PHTR BLK
5 86161470 11-800444 1 ELBOW, 2” 45D PVC SCH40
6 86161460 15-808123 1 DUMP VALVE, 2’
7 86237770 35256 1 GASKET, DUMP VALVE
8 86033320 78474 1 VAC STACK ASM, 6 GAL PORTABLE
9 86161510 43-807109 1 GASKET, VAC TANK 10 86161820 56-502156 1 LID, VACUUM TANK 11 86161960 70222 6 SCR, #8 X 1/2 PPHST BLK 12 86199840 090-12A 1 FLOAT CAGE ASSY COMPLETE 13 86242230 500009 1 LABEL, WARNING
SERIAL NO.
FROM
NOTES:
CHEYENNE 86038850 03/08/07
5-18
Page 36
RECOVERY TANK- 2 STAGE WITH HEAT GROUP
10
9
13
11
8
12
2
1
11
3
4
5
6
7
5-19
CHEYENNE 86038850 03/08/07
Page 37
RECOVERY TANK-2 STAGE-WITH HEAT PARTS LIST
REF PART NO. PART NO. QTY DESCRIPTION
1 86161910 48-941382 1 PLATE, SWITCH MODEL 2
2 86162010 32-900195 3 SWITCH, DPST, LIGHTED ROCKER
3 86042340 50-501882 1 BRKT, HEATER MOUNT
4 86275210 70384 4 SCR, 1/4-20 X 1/2 PHTR BLK
5 86161470 11-800444 1 ELBOW, 2” 45D PVC SCH40
6 86161460 15-808123 1 DUMP VALVE, 2’
7 86237770 35256 1 GASKET, DUMP VALVE
8 86033320 78474 1 VAC STACK ASM, 6 GAL PORTABLE
9 86161510 43-807109 1 GASKET, VAC TANK 10 86161820 56-502156 1 LID, VACUUM TANK 11 86161960 70222 6 SCR, #8 X 1/2 PPHST BLK 12 86199840 090-12A 1 FLOAT CAGE ASSY COMPLETE 13 86242230 500009 1 LABEL, WARNING
SERIAL NO.
FROM
NOTES:
CHEYENNE 86038850 03/08/07
5-20
Page 38
RECOVERY TANK- 3 STAGE WITH HEAT GROUP
10
9
13
11
8
12
2
1
11
3
4
5
6
7
5-21
CHEYENNE 86038850 03/08/07
Page 39
RECOVERY TANK-3 STAGE-WITH HEAT PARTS LIST
REF PART NO. PRVNO. QTY DESCRIPTION
1 86161930 48-941384 1 PLATE, SWITCH HP
2 86162010 32-900195 3 SWITCH, DPST, LIGHTED ROCKER
3 86042340 50-501882 1 BRKT, HEATER MOUNT
4 86275210 70384 4 SCR, 1/4-20 X 1/2 PHTR BLK
5 86161470 11-800444 1 ELBOW, 2” 45D PVC SCH40
6 86161460 15-808123 1 DUMP VALVE, 2’
7 86237770 35256 1 GASKET, DUMP VALVE
8 86033320 78474 1 VAC STACK ASM, 6 GAL PORTABLE
9 86161510 43-807109 1 GASKET, VAC TANK 10 86161820 56-502156 1 LID, VACUUM TANK 11 86161960 70222 6 SCR, #8 X 1/2 PPHST BLK 12 86199840 090-12A 1 FLOAT CAGE ASSY COMPLETE 13 86242230 500009 1 LABEL, WARNING
SERIAL NO.
FROM
NOTES:
CHEYENNE 86038850 03/08/07
5-22
Page 40
VACUUM GROUP (2 STAGE)
11
6
12
8
10
9
1
6
3
2
7
4
2
3
4
6
5
5-23
CHEYENNE 86038850 03/08/07
Page 41
VACUUM GROUP-2 STAGE PARTS LIST
4
REF PART NO. PRV NO. QTY DESCRIPTION
1 86005810 57245 3 NUT, 1/4-20 HEX NYLOCK SS
2 86003760 35166 2 GASKET, VAC MTR
3 86201970 065-92 6 VAC SPACER 2 1/4 II STAGE
4 86202040 360-04A 2 VAC MOTOR, 120V 5.7 2ST TD
- 86202070 360-04B - BRUSHES, VAC FOR 116392-00 SERVICE ONLY
- 86135320 140687 - BRUSH SET, 120V VAC WINDSOR 1000121568 SERVICE ONLY 5 86007010 70663 3 SCR, 1/4-20 X 3 1/4 HHCS PLT 6 86010630 87013 9 WASHER, 1/4 ID X 5/8 OD SS 7 86005710 57105 3 NUT, 1/4-20 HEX W/ STAR WASHER 8 86042350 56-502084 1 BRKT, VAC MOUNT, DUAL 2 STG 9 86161520 43-807517 1 GASKET, VAC MTG.
10 86027140 75377 1 TANK, RECOVERY, CHEYENNE 11 86256480 70813 3 STUD, 1/4-20 X 3.5 SS 12 86273750 70011 3 SCR, 1/4-20 X 5/8 HHCS SS
SERIAL NO.
FROM
NOTES:
CHEYENNE 86038850 03/08/07
5-2
Page 42
VACUUM GROUP – 3 STAGE
11
6
10
9
8
6
3
12
2
7
4
1
2
3
4
6
5
5-25
CHEYENNE 86038850 03/08/07
Page 43
VACUUM GROUP-3 STAGE PARTS LIST
6
REF PART NO. PRV NO. QTY DESCRIPTION
1 86005810 57245 3 NUT, 1/4-20 HEX NYLOCK SS 2 86003760 35166 2 GASKET, VAC MTR 3 86201950 065-24E 6 VAC SPACER 3 1/8 4 86124130 53130 2 VAC MOTOR, 120V 5.7 3ST W/O TB *
- 86135320 140687 - BRUSH SET, 120V VAC WINDSOR
- 86135300 140676 - BRUSH SET, 120V 3ST VAC AMETEK 5 86216610 70062 3 SCR, 1/4-20 X 4 HHCS GR5 PLTD
6 86010630 87013 9 WASHER, 1/4 ID X 5/8 OD SS 7 86005710 57105 3 NUT, 1/4-20 HEX W/ STAR WASHER
8 86042320 56-502091 1 9 86161520 43-807517 1 GASKET, VAC MTG.
10 86027140 75377 1 TANK, RECOVERY, CHEYENNE 11 86256490 70814 3 STUD, 1/4-20 X 4.5 SS 12 86273750 70011 3 SCR, 1/4-20 X 5/8 HHCS SS
BRACKET, VACUUM MOUNT, 3 STAGE
SERIAL NO.
FROM
* SERVICE
SERVICE
NOTES:
ONLY ONLY
CHEYENNE 86038850 03/08/07
5-2
Page 44
VACUUM GROUP SINGLE 7.2 3-STAGE
9
3
10
1
2
3
4
8
7
6
5
5-27
CHEYENNE 86038850 03/08/07
Page 45
VACUUM GROUP-3 STAGE (7.2) PARTS LIST
REF PART NO. PRV NO. QTY DESCRIPTION
1 86005810 57245 3 NUT, 1/4-20 HEX NYLOCK SS 2 86201940 065-24C 3 VAC SPACER 2 1/2 3 86010630 87013 18 WASHER, 1/4 ID X 5/8 OD SS 4 86020710 70062 3 SCR, 1/4-20 X 4 HHCS GR5 PLTD 5 86202050 360-05A 1 VAC, 117507-13 110V 3 ST 7.2 6 86003760 35166 1 GASKET, VAC MTR 7 86042330 56-502092 1 BRACKET, VACUUM MOUNTING 7.2 8 86273750 70011 6 SCR, 1/4-20 X 5/8 HHCS SS 9 86161520 43-807517 1 GASKET, VAC MTG.
10 86027140 75377 1 TANK, RECOVERY CHEYENNE
SERIAL NO.
FROM
NOTES:
CHEYENNE 86038850 03/08/07
5-28
Page 46
HEATER GROUP
24
23
23
22
21
24
20
18
16
25
19
26
22
21
20
1
19
4
4
4
17
2
3
4
5-29
5
4
15
14
28
29
27
6
13
29
11
28
7
O
I
9
12
8
10
CHEYENNE 86038850 05/02/09
Page 47
HEATER GROUP Parts List
REF PART NO. PART NO. QTY DESCRIPTION
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29
86161750 48-941396 1 LABEL, HEATER WARNING PROCHEM 86241010 41504 1 HOUSING, CAP OUTLET END NU 86245650 50776 1 LABEL, FOR SAFETY 86006790 70351 5 SCR, 10-32 X 3/8 HHTR W/STAR 86005700 57104 1 NUT, 10-32 W/STAR WASHER PLTD 86241470 41513 1 INSULATION, HEATER 86201790 130-14C 86201800 130-14 1 HEATER ELEMENT 110V 86162010 32-900195 1 SWITCH, DPST, LGHTD RCKR GRN 86246490 51041 1 LIGHT, 115V NEON INDICATOR 86171080 41503 1 HOUSING, CAP SWITCH END NU 86233480 22046 1 CLIP, NEON LAMP 86006180 66095 1 PLUG, 1/8 MPT HEX BRASS 86201810 130-14I 1 THERMOSTAT W/SPADE LEADS 86264110 41514 1 INSULATION PAPER 86268800 88623 1 WIRE, 4” G/Y/14 76010 X 76010 86092890 41502 1 HOUSING ASM, HEATER PORT NU 86005670 57040 1 NUT, ½ NPT CONDUIT 86175890 11-800039 2 BUSH, ¼ x 1/8 BR 86180360 12-800040 2 ELL, 1/8P X 1/4T BR 86008920 80889 2 BOOT, RUBBER TERM. ISOLATOR 86183990 10-805393 2 HOS, 3/16 X 14-1/4(1/4FT) BS 86180340 12-800031 2 ELL, 1/4P X 1/4T BR 86002450 22015 2 COUPLER, ¼ QD 86256240 73505 1 STRAIN RELIEF, ½ NPT TRUMPET 86199530 060-04 1 CORD ASM, 12/ SJT X 25’ BLK 86326680 - 1 HEATER CART, CASE WELDED 86200870 300-06A 3 PAN HD SH MTL SCREW 6 X 3/16 B 86010650 87018 3 WASHER, #10 X 9/16 OD
1
THERMOSTAT RESET 302
SERIAL NO.
FROM
NOTES:
CHEYENNE 86038850 06/09/09
5-30
Page 48
TANK & LID PARTS
1
7
2
3
4
3
(86161800, PRV
NO. 46-802531)
Keeper)
6
5
5-31
CHEYENNE 86038850 03/08/07
Page 49
TANK & LID PARTS LIST
2
REF PART NO. PART NO. QTY DESCRIPTION
1 86027120 51363 1 LID, CHEYENNE 2 86161960 70222 4 SCR, #8 X 1/2 PPHST BLK 3 86006950 70532 12 SCR, 10-32 X 1/2 PPHMS BLK NP 4 86161570 46-802530 2 HINGE, SOUTHCO C6-34 5 86161590 46-802540 2 HINGE, SOL. VAC TANK 6 86005720 57106 2 NUT, 8-32 W/ STAR WASHER PLTD 7 86020650 70051 2 SCR, 8-32 X 1/2 PPHMS NP
SERIAL NO.
FROM
NOTES:
CHEYENNE 86038850 03/08/07
5-3
Page 50
LABEL & STRAP GROUP
3
1AB
2
5-33
CHEYENNE 86038850 03/08/07
Page 51
LABEL & STRAP PARTS LIST
4
REF
1A 86202160 320-05 1 VELCRO STRAP 1B 86202160 320-05 2 VELCRO STRAP
2 86243360 500531 2 3 86161780 500567 1
PART
NO.
PRV
NO.
QTY DESCRIPTION
LABEL, PROCHEM LOGO 6 X 1.75 LABEL, CHEYENNE MAIN
SERIAL
NO.
NOTES:
10075210, PRV NO. C3, AND 10075220, C3HP ONLY
CHEYENNE 86038850 03/08/07
5-3
Page 52
WIRE GROUP 100 PSI 2ST VAC
5-35
CHEYENNE 86038850 03/08/07
Page 53
WIRE GROUP
6
100 PSI
3 ST VAC
CHEYENNE 86038850 03/08/07
5-3
Page 54
WIRE GROUP 200 PSI 3 ST VAC
5-37
CHEYENNE 86038850 03/08/07
Page 55
WIRE GROUP
8
200 PSI
7.2 3 ST VAC
CHEYENNE 86038850 03/08/07
5-3
Page 56
WIRE GROUP - HEATER
INSULATION 86282790
PRV NO. 730129
86266030
PRV NO. 76031
86266250
PRV NO. 76064L
86267560
PRV NO. 880300
(130-14C)
86266030
PRV NO. 76031
86282790
PRV NO. 730129
WHITE WIRE 5"
BLACK WIRE 5"
GREEN WIRE 5"
86266250
PRV NO. 76064L
ON HTR CORE
SAFETY
SWITCH
86282790
PRV NO. 730129
1
2
4
5
86267560
PRV NO. 880300
86266250
PRV NO. 76064L
5"
LIGHT
5"
POWER SWITCH
86268800
PRV NO. 88623
ON HTR CANISTER
86282800
PRV NO. 730314
4"
H E A T E
R
E L E
M
E N T
THERMAL
SWITCH
(130-14
I)
5-39
5"
CHEYENNE 86038850 03/08/07
Loading...