This product is warranted to be free from defects in material and/or
workmanship for a period of one (2) year from date of original installation
(with the exception of racks, pans, and covers). Any component which
proves to be faulty in material and/or workmanship will be replaced or
repaired (at the option of Prince Castle, Inc.) without cost to the customer
for parts or labor. This warranty covers on location service (i.e. trip
charges and/or mileage). Travel mileage is limited to 100 miles (200
kilometers -International) round trip (one trip warranty) from an
authorized service agency or its sub-service agency.
This warranty is subject to the following exceptions/conditions:
•
Use of any non-genuine Prince Castle parts voids this warranty.
•
All labor shall be performed during regular work hours. Overtime
premium will be charged to the buyer.
•
Damage caused by carelessness, neglect, and/or abuse (e.g.,
dropping, tampering or altering parts, equipment damaged in
shipment, by fire, flood or an act of God) is not covered under this
warranty.
Indicates information important to the proper operation of the unit.
Indicates information important to the operation of the unit. Failure to
Failure to observe may result in damage to the equipment and/or
observe may result in damage to the equipment.
severe bodily injury or death.
Installation
A. Remove the unit from the carton and inspect for signs of damage. If
there is damage to the unit:
•
notify the carrier within 24 hours of delivery
•
save carton and packaging materials for inspection purposes
•
contact your local dealer, or if purchased directly, the Prince Castle
Sales Department at 800-722-7853 or 1-630-462-8800 to arrange for a
replacement unit.
NOTE: When installing this unit, the ambient temperature at the mounting
site should not exceed 100°F.
B.
Place the bin on a counter and seal the base to the counter with foodapproved sealant.
C.
Plug the power cord into the bin and connect the plug into the proper
electrical outlet (15 amp, 120 Volt). All connections must be in
accordance with local electrical codes and any other applicable codes.
NOTE: The electrical receptacle should be a dedicated outlet. No other
equipment should be operating on the line (refrigerators, fryers, etc.).
D.
Install the racks, pans and pan covers into the cavities.
E.
Turn the power switch to ON. Allow 30 minutes for warm-up.n
Prince Castle reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to
corresponding changes, improvements, additions or replacements for previously purchased equipment.
Load pan covers (if used) onto pan racks and
insert racks into the unit.
Allow 30 minutes for heaters to
reach operating temperature.
The Temperature Display will
show temperature as unit warms
B
C
D
LED Timing Status
3
up to the operating temperature.
Power On/Off Switch
Press all PAN buttons (if applicable).
2
The PAN DISPLAYS will show the
assigned product name.
If no product is assigned, the
display will be dim and show “- - - -”.
Pressing the PAN button will not
activate the timer if “- - - -” is
displayed. Pressing PAN button
when product name is displayed
will start timing cycle.
To begin timing cycle, load product and press the PAN button.
4
A
BKFT (Breakfast) or REG
(Regular Menu) will be lit
depending on preprogrammed menu.
If no other pan is active for a
product, the LED for the first
pan loaded will turn GREEN.
LED Timers
RED (flashing) = Discard product
GREEN (steady) = Oldest product, use first
GREEN (flashing) = Cook more product
YELLOW (steady) = Newer product, use green first
YELLOW (flashing) = Cook more product
B
C
D
If only one pan is active for a
product, the LED will turn
GREEN.
The LED for the 2nd pan (3rd
pan, etc.) loaded will turn
YELLOW.
An LED timer can be stopped
(cancelled) at any time by
pressing and releasing the
corresponding PAN button.
When any of the timer LEDs flash, cook more product or remove
and discard product as indicated.
GREEN Flashing = Cook more
product
YELLOW Flashing = Cook
more product
RED Flashing = Discard
product
WARNING
Hot surfaces.
To shut down the unit, turn the power On/Off switch to OFF.
NOTE: To load preset times/menus:
A.
Turn power switch to OFF.
B.
Press and hold both the UP and DOWN Arrow buttons.
C.
Turn power switch ON.
D.
When the four right-most displays show PRESET LOADED, release the buttons.
A
B
C
D
Product, along with any remaining time, can be transferred
from one cavity to another as follows:
A. Press and release the
TRANSFER button on the
timer bar of the product to be
moved. Displays for all pans
available for transfer will be
brightly lit. All others will be
dimly lit.
B. Press and release the
PAN button of the
product to be moved.
NOTE: If product transfer is not completed within a pre-programmed
transfer time, the transfer will be cancelled. See your Manager.
D.
C.
Press and release the
TRANSFER button on the bar
where the product will be
moved. All available pan
locations on the bar will be
brightly lit.
Press and release the PAN button for the
new location. The new location will finish
timing the product. When the transferred
pan time expires, the location will revert
back to the original menu settings.
Before performing any maintenance, turn the power switch to the
OFF position and unplug the power cord from the electrical
receptacle.
WARNING
Cleaning
This unit is not watertight. Do not clean with a water jet/jet spray. Do not
immerse the unit in water.
1.
Turn the unit off and unplug the power cord from the electrical
receptacle.
2.
Remove the pan covers and pan racks. Wipe all parts and unit with a
damp cloth. DO NOT use a green Scotch Bright pad cleaner, ice or
water.
The bin heater temperature display and control have been incorporated into the
POSA Main time bar of the Universal JIB Series bin. This bin has four Main timer
bars on the front. Figure 1 shows the default bar positions POSA, POSB, and POSC.
Refer to the Timer Bar Positions below. The timer bar set for position POSA control
the bin heaters. The timer bars for positions POSB, POSC and POSD
do not have heater control.
POSD
Bar
Positions
Note: These instructions are only for the bar set to position POSA.
On the Main timer bar, press the Prince Castle Logo and the Down Arrow buttons together and release. The displays will show temperature
information for the uppermost heater as show in Table 1 below. The temperatures show are examples only.
Table 1
Set Temperature Actual Temperature Heater Location Heater Indicator
275S 276A AUPR H
Set Temperature: The current temperature goal for the displayed heater
Actual Temperature: The current actual temperature for the displayed heater.
Heater Location: This is the heater location within the bin shelf being displayed. Each heater extends to the entire width and depth of the shelf.
Heat Indicator: H will be shown when the bin controller has turned on the heater. H will flash when a fault condition exists for the displayed heater.
To display information for the other heaters in the bin, press the Up or Down Arrow buttons to scroll through each heater display. Table 2 show the
heater information that will be displayed. The temperatures and Heat Indicator displays show are examples only.
Figure 1
Heater fault indications will be displayed instead of an actual temperature in a heater error condition exists. These indications are:
Open Relay: Actual Temperature display alternates between OPEN and RELY
Shorted Relay: Actual Temperature display alternates between SHRT and RELY
High Temperature: Actual Temperature display shows HHHH
These fault indicators will be accompanied by the Heat Indicator display flashing H.
The Actual Temperature display will show LLL (low temperature) if the heater temperature is below 75°F, such as during warm-up.
To cancel the heater display and go back to normal timer displays,
press the Prince Castle Logo and the Up Arrow buttons together
and release. The displays will return to showing product names or
remaining time if a timer is running. Also, the heater display will
cancel itself after 20 seconds of no button presses
Changing Set Point Temperatures for Heaters:
Note: The upper and lower heaters in each shelf extend to the entire width and depth of the shelf.
The Heater temperatures are linked to the product time. There are two product types(Grilled and Fried). If you change the
temperature for one product within the product types, all the temperatures for the product type will change together.
1. Make sure that there are no timers active by cancelling the time or resetting the machine by turning the unit off then on.
2. Press and hold the Prince Castle Logo button and then press and hold the Menu/Enter button. Hold both for 6 seconds. The display will change.
3. Press the Up and Down Arrow buttons to scroll to “PRODTEMP”.
4. Press Menu/Enter to select this option. A product name will be displayed.
5. Press the Up and Down Arrow buttons to scroll to the desired Product that you would like to change the set point temperature for.
6. Press the Menu/Enter button to select this option.
7. Use the Up and Down Arrow buttons to scroll to the desired heater set point temperature.
8. Press the Menu/Enter button to save this selection.
9. Repeat steps 4 to 8 for changes to the temperature of another Product.
10. Press the Logo button when finished with heater set point temperature changes.
This program menu item is only available in the bar set for POSA.
Temperatures can be displayed in either degrees Fahrenheit (default)
or Celsius
1. On the Main timer bar, press and hold the Prince Castle Logo and
Menu/Enter buttons together of 6 seconds. The display will change to
program mode.
2. Use the Up and Down Arrow buttons to scroll to the DEGR F/C
display.
3. Press the Menu/Enter button. Either the F or C will begin flashing to
indicate the currently selected scale, F (Fahrenheit) or C (Celsius).
4. Use the Up and Down Arrow buttons to change the selected scale.
5. Press the Menu/Enter button to accept any changes. The flashing
will stop.
6. Press the Prince Castle Logo button when done. The bar will return
to normal operating mode.
This program menu item is only available in the bar set for POSA.
Note: Allow a sufficient amount of time for temperatures to stabilize before starting calibration.
Measuring temperature:
1. View the actual heater temperatures as described above.
2. Using stand-alone temperature meter (not supplied), take a temperature reading within the shelf near the center of the heater surface.
3. If the actual temperature displayed by the timer bar does not closely match the meter, the displayed temperature can be adjusted as follows.
Adjusting the temperature display:
1. On the Main timer bar, press and hold the Prince Castle Logo and Menu/Enter buttons together for 6 seconds. The display will change to program
mode.
2. Use the Up and Down Arrow buttons to scroll to the CAL HTRS display.
3. Press the Menu/Enter button. THe display will show SEL AUPR for shelf A, upper heater.
4. Use the Up and Down Arrow buttons to scroll to the heater to adjust. THe display will cycle through heaters AUPR, ALWR, BUPR, CUPR and CLWR>
See Figure 1 above for shelf and heater locations.
5. Press the Menu/Enter button. The display will show CAL AUPR (if AUPR was chosen) and the actual temperature number. This number may fluctuate
by a degree since it is the actual temperature reading.
6. Press and release the Up or Down Arrow buttons to increase or decrease the displayed temperature number. The number can be increased by up to
20 degrees, or decreased by up to 20 degrees. The display may not change instantly. For example, if the display shows 200 and the handheld meter
shows 205, press the Up Arrow button 5 times. THe display will increment for the number of button pushes until it shows 205. This number may fluctuate
by a degree since it is the actual temperature reading.
7. Press the Menu/Enter button. The display will go back to CAL HTRS again.
8. Repeat this process for the other heaters.
9. Press the Prince Castle Logo button when done. The bar will return to normal operating mode.
There are three menus available:
Breakfast = Menu 1
Fried =Menu 2
Grilled = Menu 3
Press and hold the MENU/ENTER button, then use the UP or
DOWN Arrow button to scroll through the 3 menus.
When scrolling, menu numbers
appear in this display.
2
When the desired menu is displayed, release the MENU/
ENTER button. The food products for the menu will be
displayed in the upper and lower PAN displays.
When timers for a different menu are still active,
those BKFT or REG LEDs will flash until they are
all cancelled.
Press and hold the PRINCE CASTLE LOGO button (on the
2
the MENU/ENTER button will show the menu choices. Use the
UP or DOWN Arrow button to scroll through the 3 menus.
Release the MENU/ENTER button when the desired menu is
displayed.
Press and hold the MENU/ENTER button. The display next to
When the MENU/ENTER button is released, all
displays will again show PROG.
3
LED will turn YELLOW and the display will change from
PROG to the assigned product choice.
A. Press the PAN button next to the display to be changed. The
B.
Press the UP or DOWN Arrow button to scroll to the desired product
choice.
C.
Press the MENU/ENTER button to save the selection. All displays
will show PROG.
4
A.
Repeat Steps 2 and 3 as required.
B.
Press the PRINCE CASTLE LOGO button to exit the
Program Mode and return to the Run Mode.
NOTE: Up to six items (one for each menu) may be programmed
for each PAN button. A pan may be set as “not used” by
assigning “ - - - -” as its product.
Changing the Hold and Cook-More Times
1
A.
The SET PRODUCT TIME menu is used to change the Hold and Cook-More times.
B.
Press and hold the PRINCE CASTLE LOGO button, then immediately press and hold the MENU/ENTER button until the
display shows one of the programming menus.
C.
Use the UP or DOWN Arrow button to scroll to the PROD TIME ENTR menu. (NOTE: Units with 6 or 8 Pan displays will
show SET PRODUCT TIME ENTR.)
Set Product Time menu. The display will show, for example,
EGGS TIME ENTR.
B. Use the UP or DOWN Arrow button to scroll through the list
of products. When the desired product is displayed, press
the MENU/ENTER button to select it.
Refer to the Product Menu Details on page 11 for a list of products and
their corresponding display names.
A. Press and release the MENU/ENTER button to enter the
NOTE: Holding the UP or DOWN Arrow button for longer than
2 seconds will cause the product list to automatically scroll up or down.
3
A. The display now shows the current Hold time.
B. Use the UP or DOWN Arrow button to scroll to the desired Hold time.
When the desired Hold time is displayed, press the MENU/ENTER
button to save the desired Hold time.
NOTE: Hold time cannot be reduced to less than the Cook-More
time plus one minute.
4
or DOWN Arrow button to scroll to the desired Cook-More time.
A. The display will now show current Cook-More time. Use the UP
B. When the desired Cook-More time is displayed, press the MENU/
ENTER button to save it.
NOTE: Cook-More time cannot be increased to more than the Hold
time minus one minute.
5
4
A. The display will show PROD TIME ENTR. Repeat Steps 2 –
for any other product.
B. Press and release the PRINCE CASTLE LOGO button at any
time to exit the Program Mode and return to the Run Mode.
NOTE: If the MENU/ENTER button has not been pressed to save
any changes, the program will revert to the original values.
Setting the Alternating Display Interval
A.
The Alternating Display Interval allows the timer bar displays to alternate between the product name and remaining Hold time. The default setting
is 5 seconds.
B.
Press and hold the PRINCE CASTLE LOGO button, then immediately press and hold the MENU/ENTER button until the display shows one of the
programming menus.
C.
Use the UP or DOWN Arrow button to scroll to the DISP ALT TIME menu. Press MENU/ENTER button.
D.
Use the UP and DOWN Arrow buttons to adjust the interval setting from 0 to 15 seconds. Press MENU/ENTER to save the change.
E.
Press and hold the PRINCE CASTLE LOGO button at any time to exit the Program Mode.
The EDIT PRODUCT NAME menu is used to change a default product name to one of your own choosing.
B.
Press and hold the PRINCE CASTLE LOGO button, then immediately press and hold the MENU/ENTER button until the display shows
one of four programming menus.
C.
Use the UP or DOWN Arrow button to scroll to the PROD NAME ENTR menu.
NOTE: The default names available for editing are listed on page 11.
PRINCE CASTLE LOGO Button
MENU/ENTER Button
2
Product Name menu.
A Press and release the MENU/ENTER button to enter the Edit
The display will read PROD XXXX ENTR.
B.
Use the UP or DOWN Arrow button to scroll through the list of
products.
C.
When the desired product is displayed, press the MENU/
ENTER button to select it. The first letter (in this case, the E )
will start blinking.
3
to scroll to the desired letter/number/symbol.
A. To change the blinking E, use the UP or DOWN Arrow button
B.
When the desired selection is displayed, press the PAN button
(to the left or right of the selected display) to move to the next
digit.
C.
Repeat for all digits.
NOTE: Holding the UP or DOWN Arrow button for longer than 2
seconds will cause the selected digit to automatically scroll up or down.
4
ENTER button to save the new name.
When all four digits have been changed, press the MENU/
5
– 4 for any other product.
A. The display will show PROD NAME ENTR. Repeat Steps 2
B. Press and release the PRINCE CASTLE LOGO button at any
time to exit the Program Mode and return to the Run Mode.
NOTE: If the MENU/ENTER button has not been pressed to save
any changes, the program will revert to the original names.
Press and hold the PRINCE CASTLE LOGO button, then immediately press and hold the MENU/ENTER button until the display shows
one of the programming menus.
C.
Use the UP or DOWN Arrow button to scroll to the Set Vol 0 ENTR menu.
PRINCE CASTLE LOGO Button
MENU/ENTER Button
2
A.
Press and release the MENU/ENTER button to enter the Set
Volume menu.
B.
The display shows SET VOL 0 ENTR. This shows that
the volume is currently turned off.
The volume may be set for Vol 0 (off) or for volume levels Vol 1
through Vol 3.
3
A.
To change the volume level, use the UP or DOWN Arrow
button to scroll to the desired level. When the desired
selection is displayed, press the MENU/ENTER button.
B.
Press and release the PRINCE CASTLE LOGO button at any
time to exit the Program Mode and return to the Run Mode.
NOTE: If the MENU/ENTER button has not been pressed to save
any changes, the program will revert to the original time.
making a change, press and hold the LOGO and the DOWN
To check the current position setting on the main timer bar without
buttons simultaneously. On the aux timer bar, press and hold the
LOGO button only.
One of the displays will show POS X to indicate the current
position setting, where X is the setting.
3
Use the UP or DOWN Arrow button to scroll to the desired
position. The right most display shows the position letter to be
selected. Press the MENU/ENTER button to store the new
position and return to normal Operating Mode.
NOTE: The position choices for 2 cavity bins are A and B. The
position choices for 4 cavity bins are A through F.
If the bin has a corresponding aux timer bar on the back, the aux
bar will automatically update itself to match the position selection
of its main bar.
NOTE: To cancel at any time with saving changes, press the
LOGO button.
Set Bar Position
To check the timer position on the main bar, press and hold the
1
PRINCE CASTLE LOGO button and the DOWN Arrow button.
The current timer bar position will be displayed in the far right
timer display as POS X.
NOTE: X = the setting.
To change the timer bar position, proceed to Step 2.
To check the timer position on the aux bar press and hold the
logo only.
2
PRINCE CASTLE LOGO button and the DOWN Arrow button for
approximately 6 seconds or until the display shows POSN # $ ENTR POS X.
The address number will blink on/off.
NOTE: X = current bar position setting. SET will not show on the
4 channel bar.
To change the main timer bar position, press and hold the
To check the bar address on the main timer bar, press and hold the LOGO
Position
Address Default
A
B
C
D
E
F
1
2
3
4
5
6
Timer Bar Positions on Bins
DHB4PT-20UJB & DHB4SS-20UJB
Four cavity bin with four 4-channel timer bars:
Timer Bar Position A, Address1
Timer Bar Position B, Address 2
Timer Bar Position C, Address 3
Timer Bar Position D, Address 4
DHB2PT-33UJB & DHB2SS-20UJB
Two cavity bin with two 8-channel timer bars:
Timer Bar Position A, Address 1
Timer Bar Position B, Address 2
Bar Address
button and the DOWN Arrow simultaneously. On the aux bar press and
hold the LOGO only button. The bar address is shown as BARy as on
other bars where y is the address.
The Timer Bar address is automatically set when the Bar Position is
selected as follows:
The address can be changed at power on as on other bars, but loading
presets will change the address back to the default in the list above.
Loading presets will not change the selected position.
Shorted relay. Circuit inoperable.
Open heater.
Unplugged ribbon cable between power and
main circuit boards.
Consult an authorized Service Technician.
Display flashes Opn and rEL.
Temperature is below 75°F.
Heater inoperable.
Probe inoperable.
Relay inoperable.
Consult an authorized Service Technician.
Display shows HHH for an extended period of
time and heater surface temperature is hot.
Temperature is above 300°F (abnormal
operation).
Consult an authorized Service Technician.
Display shows HHH for an extended period of
time and heater surface temperature is cool.
Probe is inoperable.
Special Programming Mode
1
A.
Press and hold the PRINCE CASTLE LOGO button then immediately press and hold the MENU/ENTER button. Hold both buttons for six
seconds. The displays will change to show the first menu — depending on model.
B.
Press and release the UP and DOWN buttons to scroll through the list of Special Modes.
PRINCE CASTLE LOGO Button
MENU/ENTER Button
2
Set Link Group
NOTE: Preset link group is set to GRP1 from factory.
A.
When the displays show SET LINK GRPx ENTR, the X indicates the currently assigned Link Group. Press and release the MENU/
ENTER button to set the Link Group Mode.
B.
The link group number (X) will flash. Press and release the UP or DOWN Arrow button to change the group number. The maximum
number allowed is 3, and the minimum is 0. When a Timer Bar is assigned to Link Group 0, it is isolated and not associated with any
other Timer Bar (linking is disabled).
C.
When the desired link group is displayed, press and release the MENU/ENTER button to save it. The program will revert to Set Link
Group Mode.