1. Remove face plate and driver assembly by removing 10-32 tamper resistant screws and place them in bag enclosed. Be careful not to lose any fasteners.
2. Secure the housing appropriately. a. For concrete pour and masonry construction refer to Figure 2 and 3. b. For drywall construction refer to Figure 4, 5, and 6.
3.Connect black fixture wire to black supply wire.
4. Connect white fixture wire to white supply wire and black fixture wire to black supply wire.
5. Secure face plate and driver assembly to housing using tamper proof fasteners removed during step1.
WARNING:
1. DO NOT pinch wires between LED faceplate, driver assembly, and housing. Consult a Qualified Electrician for all other options that require other wiring configurations.
WARNING:
2. This Product contains chemicals known to the State of California to cause cancer, birth defects and/or other repro-
ductive harm. Thoroughly wash hands after installing, handling, cleaning, or otherwise touching this product.
FIG. 1
IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information and instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials, and proper lamping. Do not install in areas subject to combustible vapors or gases. Before wiring to power supply and during servicing or relamping, turn off power at fuse or circuit breaker. All servicing or relamping must be performed
by qualified service personnel. Product must be grounded to avoid potential electric shock or other potential haz­ard. Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in compliance with the National Electrical Code and local codes. The use of accessory equipment not recommended
by the manufacturer or installed contrary to instructions may cause an unsafe condition. Do not block light emanating from product in whole or part, as this may cause an unsafe condition. Do not allow items such as drapes, curtains, screens or the like to come into contact with the product or to block light from the product, as this may cause an unsafe condition.
FACE PLATE AND LED ASSEMBLY
HOUSING
(2) 10-32 TAMPER RESISTANT SOCKET HEAD CAP SCREWS.
BLACK AND WHITE WIRE TO BE CONNECTED TO SUPPLY.
Part No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .93017297
InstructionSheet
701 Millennium Blvd., • Greenville, SC 29607
With representatives offices in principal cities throughout North America. Copyright 2008, 09/12 revision, All Rights Reserved - Printed in U.S.A.
Installation Instructions Recessed LED Aisle Light- SLLED2
For Concrete Installation (Housing Installation)
FIG. 2
FIG. 3
For Concrete Installation
1. Select a threaded hole in housing to be used for supply wire access. Insert plugs into threaded holes not being used.
2. Attach housing with conduit mounted to concrete form, housing flange face must be flush with concrete surface.
3. Run supply wires in accordance with local and national electrical codes.
CONCRETE
HOUSING
CONDUIT CONNECTION
GASKET TYPICAL
(For wet or drywall installation see figure 4)
For Masonry Installation
1. Select a threaded hole in housing to be used for supply wire access. Insert plugs into threaded holes not being used.
2. Remove one masonry brick from the wall at the desired location for the fixture.
3. Insert the fixture housing into the wall and secure in place with mortar. Front surface of housing must be flush with masonry surface.
NOTE: IT IS RECOMMENDED THAT THE ALUMINUM HOUSING BE COATED WITH AN ASPHALT PAINT CONTAING ALUMINUM PIGMENT.
NOTE: PRESCOLITE CONCRETE MOUNTING BOX P/N: SLD12CMB IS TO BE USED WITH SLLED1 OR
SLLED2 HOUSINGS ONLY.
Part No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .93017297
InstructionSheet
701 Millennium Blvd., • Greenville, SC 29607
With representatives offices in principal cities throughout North America. Copyright 2008, 09/12 revision, All Rights Reserved - Printed in U.S.A.
HOUSING
CONDUIT CONNECTION
DRY CONSTRUCTION
FACE OF HOUSING MUST BE FLUSH OR PROTRUDE SLIGHTLY FROM WALL FOR PROPER SEAL.
GASKET TYPICAL
SCREWS TO MOUNT HANGER BAR BRACKETS
FIG. 6
For W
et or Drywall Installation
1. Use the hanger bar bracket which is sold seperately as SLMB.
2. Remove screws from housing and use them to secure brackets to housing shown in FIG 4.
3. Slip bar hangers into brackets.
4. Hold housing in desired position and drive barbs into studs. If needed reinforce with nails or screws.
5. If desired brackets can be mounted directly to framing
members as shown in FIG 5.
6. Run supply wires in accordance with local and national electical codes.
Installation Instructions Recessed LED Aisle Light- SLLED2
For Wet or Drywall Installation (Housing Installation)
FIG. 4
FIG. 5
(For concrete installation see figure 2)
HANGER BARS
SUPPORT FRAME
3.87
(BY OTHERS)
CONDUIT (BY OTHERS)