Magnetic safety switches for monitoring the position of movable guards in
accordance with EN 60947-5-3
Approvals
PSEN 2.1p-21
Unit features
` The actuator PSEN 2,1-20 belongs
to the safety switch
` 2 reed contacts (1 N/C, 1 N/O)
` Assured operating distance: 8 mm
` Assured release distance: 26 mm
` Square design
` Works magnetically
` Switching voltage 24 VDC
` Series connection via PSEN i1 in-
terface
` LED to display switch status
Unit description
The safety switch meets the requirements of EN 60204-1 and IEC 60204-
1.
The safety switch only complies with
EN 60947-5-3 in conjunction with the
actuator PSEN 2,1-20 and its approved evaluation devices.
The safety switch should only be connected to the evaluation devices listed
under "Connections".
Function description
If the actuator is within the response
range, the magnets switch the reed
contacts on the safety switch. If the
actuator is outside the response range
(safety gate open), the reed contacts
on the safety switch will switch.
energisation contacts satisfy the
requirements of category 3 in accordance with EN 954-1 and the
requirements of a PDF with single-fault tolerance (PDF-S).
–Delay time ≥ 30 s: Delay-on de-
energisation contacts satisfy the
requirements of Category 1 in
accordance with EN 954-1 and
the requirements of a PDF with
designed reliability (PDF-D).
` In the following commissioning cas-
es, check the function that detects
shorts across contacts:
– On evaluation devices with DC
supply voltage: Overall cable resistance ≥ 15 Ohms per channel
– On evaluation devices with AC
supply voltage: Overall cable resistance ≥ 25 Ohms per channel
– For details of how to perform the
test for shorts across the contacts, please refer to the operating manual for the relevant
evaluation device.
Connections
NOTICE
The colour marking for the connection
lead only applies for the cable that Pilz
supplies as an accessory.
The safety switch is shown in an unoperated condition.
ohne Querschlusserkennung/without detection of shorts
across contacts/sans détection des courts-circuits entre les
canaux
PNOZ e3.1p
PNOZ e3vp 10 s
PNOZ e3vp 300 s
mit Querschlusserkennung/with detection of shorts across
contacts/avec détection des courts-circuits entre les canaux
PNOZ e3.1p
PNOZ e3vp 10 s
PNOZ e3vp 300 s
` Connection to PNOZmulti
Schutztür/safety gate/protecteur mobile
Schaltertyp 2/switchtype 2/type du capteure 2
I0, I1: Eingänge/inputs/entrées
T0, T1: Taktausgänge/test pulse outputs/sorties
impulsionelles
` Connection to PSS with and with-
out SafetyBUS p
braun/brown/marron
A1
weiß/white/blanc
S12
schwarz/black/noir
S24
braun/brown/marron
S11
weiß/white/blanc
S12
blau/blue/bleu
S23
schwarz/black/noir
S24
blau/blue/bleu
braun/brown/marron
T0
weiß/white/blanc
I0
blau/blue/
T1
schwarz/black/noir
I1
bleu
1
2
3
4
1
2
3
4
1
2
3
4
Schutztür/safety gate/protecteur mobile
Schaltertyp 3/switchtype 3/type du capteure 3
I0, I1: Eingänge/inputs/entrées
O16, O17: Taktausgänge/test pulse outputs/sorties
impulsionelles
CAUTION!
The safety switches may only be operated on a PSS in conjunction with
standard function block SB064 or
SB066.
This data sheet is only intended for use
during configuration. For installation
and operation, please refer to the operating instructions supplied with the
unit.
Dimensions
Safety switch
13
Actuator
13
6,5
19
19
8,5
8,5
4,5
4,5
22
22
36
6,8
M8x1
10,6
26
26
36
Technical details
Switching distances
Assured operating distance S
Min. operating distance S
Assured release distance S
Switching voltage24 V
Max. switching current for reed contacts10.00 mA
Max. breaking capacity for reed contacts0.3 W
Max. switch frequency1 Hz
ActuatorPSEN 2,1-20
Ambient temperature-25 - 70 °C
Vibration to EN 60947-5-2
Frequency10 - 55 Hz
Amplitude1.00 mm
Shock stress30 g , 11 ms
Connection typeM8
CableLiYY 4 x 0,25 mm
Protection typeIP65
Housing materialPBT